| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC HOUSE NO 599 D SURYA NAGAR PHASE II SECTOR 91 FARIDABAD 121013 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121013 | L1 | Accepted-AOC L1 | |
| 2 | L2₹54.8 L+₹5.0 L (10.1%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹57.0 L+₹7.2 L (14.5%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-AOC L3 | |
| 4 | L4₹57.7 L+₹7.9 L (15.9%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹59.8 L+₹10.0 L (20.2%)Rejected-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
22 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A P SINGH, IDSE, SE
HQ CWE CHANDIMANDIR
CWE/CHM(U)-95/2020-21 REPAIR AND MAINT OF EXTERNAL ELECTRIC HT/ LT DISTRIBUTION NETWORK, REALIGING OF CERTAIN HT FEEDERS AND ALLIED WORKS AT HQ WC, PINE MARG, SEPTA AND OTHER VITAL ESTABLISHMENT AT CHANDIMANDIR MIL STATION
2021_MES_422301_1
CWE/CHM(U)-95/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE CHANDIMANDIR
Class C cat b(ii)
7 documents required · 7 mandatory
₹1,000
Yes
GE (U) CHANDIMADNIR
₹1.3 L
Yes
24 May 2021
15 Feb 2021
24 Mar 2021
15 Feb 2021
22 Mar 2021
8 Mar 2021
60 days
Amount
Excavation in trenches in hard/dense soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cable,poles etc. and getting out complete all as specified and directed.
All as per item No 01 here-in-before above but depth exc 1.5 mtr and not exc 3.0 mtr complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mm x 180mm x 40mm complete all as specified and directed.
S & F in replacement operating handle for outdoor type HT 11 KV GODO switches complete all as specified and directed.
Material & labour for sand filling with clean dry coarse sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge.
M & L GI tubes 80 mm bore light grade for cable protection on poles/walls/under road/culvert etc complete all as specified and directed.
M & L GI tubes 100 mm bore light grade for cable protection on poles/walls/under road/culvert etc complete all as specified and directed.
M & L PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in pole foundations etc complete all as specified and directed.
M & L PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts etc including provision of necessary form work complete all as specified.
M & L PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in pole / strut coping with and including necessay form work complete all as specified and directed.
Disconnecting and taking out existing defective HT cable of any size complete including joints/protection pipes etc from trenches/ducts/poles etc complete all as specified and directed.
Disconnecting and taking out existing defective LT cable of any size complete including joints/protection pipes etc from trenches/ducts/poles etc complete all as specified and directed.
Taking out old damaged HT/LT pole of any size & type and clearing the site complete all as specified and directed.
Taking down old rusted cross arms/anti climbing devices incl clamps, nuts/bolts etc complete all as specified and directed.
Taking down old unserviceable HT insulators of any size and type complete all as specified and directed.
Disconnecting and taking out feeder pillar box of any type and size complete all as specified and directed.
Taking down old burnt HT jumpers of any size/type complete all as specified and directed.
Taking down old unserviceable HT switches of any size/type complete all as specified and directed..
Taking out old unserviceable rubber mats of any size and type complete all as specified and directed.
Taking out old broken cable route indicator of any size/type complete all as specified and directed.
Taking down old unserviceable HT lightening arrestors of any size/type all as directed.
M & L in repairs GI strip 32x6 mm and connecting from earth test point to lightening arrestor installed on top of 11 mtr long poles four pole/ two pole structures all as directed.
M & L RCC 1:2:4 type B-1 using 20 mm graded stone aggregate and 8 mm dia TMT bars for making HT cable route indicator of size and shape with and including necessary form work incl wririting work , duly fixed in ground complete all as directed. Note :- 8 mm dia TMT bars shall be measured and paid separately.
M&L for MS TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia all as directed and specified.
Fixing only steel tubular swaged poles complete 11 metre long including painting with two coats of black bitumonous paint externally up to the planted depth and internally through out and remaining external portion with two coats of aluminium paint , over a coat of red oxide primer complete all as specified. (Poles obtained from item No 15 here-in-before) Note:- (a) Cost of loading/unloading and transportation of the pole to a site as direceted shall be deemed to be included in the unit rate quoted. (b) Excavation & earthwork, foundation concrete for errection of the pole will be meaured & paid for separately under respective item(s).
S & F gang operated air break switches with vertical isolation complete with drop out fuse unit assembly , triple pole, 12 insulator type, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for capacity 400 Amps, 11 KV complete with GI operating pipe of heavy duty grade of suitable length complete all as specified and directed.
All as per item No 28 here in before but of rating 200 Amps complete all as specified and directed.
S & F in repairs HT current transformer suitable 11 KV HT RMU having ratio 200-100/1 A, burden 4 VA, 50 Hz , Class 5P, accuracy level factor 10 complete making all connections and testing for proper working all as specified and directed.
M & L anti climbing devices, spikes type fabricated out of M.S. bars ( round,square and flat ) including nuts,bolts,Washers and clamps made to shape to suit the size of the pole complete all as specified and directed.
S & F in replacement MCCB 400 amps FP 415 volts 50 Hz with adjustable thermal and magnetic release , phase separators complete all as directed.
Disconnecting electric supply, taking out the existing HT 11 KV VCB of any type and any size, shifting to another site/sub stn within cantt area, installation work at new site as directed, making all electric connections and testing for proper working complete all as specified and directed. Note - All T&P , crane, vehicle for shifting shall be arranged by the contractor and unit rate quoted shall be deemed to include the cost of the same.
M & L for servicing of the outdoor type HT 11 KV 200 amps/400 amps capacity gang operated air break switch mounted on HT two pole/four pole structure by properly adjusting the mountings for ON/OFF operation by working from ground level, adjusting the length of operation rod ,lubricating the moving parts, tightening of all nuts/bolts, checking of all jumper connections for proper contact of male/female contacts, replacing worn out spares and testing for proper working complete all as specified and as directed. Note:- Spare parts will be measured and paid separately.
Supply only moving contact blade (male contact) suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified.
Supply only spring loaded fixed contacts (female contact jaw) suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and directed.
Supply only post insulators suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only tinned copper flexible wires woven connecting jumper suitable for 200 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only MS jumper carrier for 200 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only moving contact blade (male contact) suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified.
Supply only spring loaded fixed contacts (female contact jaw) suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and directed.
M & L for 40/50 mm graded crushed stone aggreegate at sub stns/under outdoor structures with and including spreading and leveling etc complete all as specified and directed.
Supply only tinned copper flexible wires woven connecting jumper suitable for 400 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
Supply only MS jumper carrier for 400 amps 11 KV outdoor GOAB switch complete all as specified and as directed.
S & F in repairs DC power pack with battery back up , input 230 volts AC and output 24 volt DC , capacity 100 watt 4 amps complete with operation indicators , terminal block, safety fuse etc and making connections with the existing circuits in HT VCB panels complete all as specified and directed.
Supply, laying jointing, testing and commissioning etc in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, 11000 volts grade cross sectional area 300 sqmm 3 core, 11 KV earthed, complete all as specified and directed.
All as per item No 46 here-in-before but 150 Sqmm 3 core complete all as specified and directed.
All as per item No 46 here-in-before but 185 Sqmm 3 core complete all as specified and directed.
All as per item No 46 here-in-before but 120 Sqmm 3 core complete all as specified and directed.
S & F HT heat shrinkable type outdoor end termination cable jointing kit sutable for 11 KV (Earthed) grade XLPE cable of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
All as per item No 50 here in before but of size 240 to 300 sqmm, 3 core complete all as specified and directed.
S & F HT heat shrinkable type indoor end termination cable jointing kit suitable for 11000 volt (Earthed) grade XLPE cable of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
All as per item No 52 here in before but of size 240 to 300 sqmm, 3 core complete all as specified.
S & F HT straight through heat shrinkable type cable jointing kit for 11 KV grade, XLPE cable of size 120 to 185 sqmm 3 core complete all as specified.
All as per item No 54 here in before but of size 240 to 300 sqmm, 3 core complete all as specified.
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 240 sqmm 3.5 core in trenches/ducts/through pipes/under culverts etc complete incl taking out the old burnt cable all as specified and as directed.
All as per item No 56 here in before but size 185 sqmm 3.5 core complete all as specified and directed.
All as per item No 56 here in before but size 300 sqmm 3.5 core complete all as specified and directed.
All as per item No 56 here in before but size 150 sqmm 3.5 core complete all as specified and directed.
All as per item No 56 here in before but size 120 sqmm 3.5 core complete all as specified and directed.
M & L cross arms,supports, clamps etc fabricated from structural steel section including nuts, bolts , washers, welding, bending ( cold or hot ) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M & L pin type insulator porcelain, vitreous white/brown including one galvanised MS spindle nut and two GI washers of size 150 mm height, 150 mm dia for 11000 volts complete all as directed.
M & L single disc porcelain, vitreous white/brown insulator 255 mm dia and 145 mm height assembly for tension with tension clamps for conductor working pressure 11000 volts complete all as specified and directed.
S & F steel tubular swaged poles complete with mild steel base plate, closed at top as specified, type 410 SP-55 (11 metre long) including painting with two coats of black bitumonous paint externally up to the planted depth and internally through out and remaining external portion with two coats of aluminium paint , over a coat of red oxide primer complete all as specified and directed. NOTE: Excavation & earthwork, foundation concrete will be meaured & paid for separately under respective item(s).
M & L in replacement danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT,25x 20 cm size complete all as specified and directed.
M & L for preparing the surfaces for repainting by removing dust/rust etc and painting of old steel tubular poles 11 Mtr long alonwith cross arms / clamps etc with two coat of aluminium paint over a coat of red oxide primer all as specified and directed. Note:- Poles alongwith cross arms fixed as two pole or four pole structures shall also be measured and paid under this item only.
S & F jumpers in red/yellow/blue colour for HT lines/connections made from aluminium conductor single core PVC insulated cable of suitable size complete including winding wires, aluminium tapes etc all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note :- Earth lead strip 32 x 6 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
Finding of fault to 11 KV UG cable with suitable fault locator equipment & pin point the fault in the faulty cable including necessary excavation and earth work for exposing the faulty portion of the UG cable complete all as specified and directed.
Material and labour for repairing/maintenance/servicing of HT 11 KV VCB along with CTs/PTs of capacity upto 1250 A of any make and type by drawing out breaker from panel and servicing/Inspecting/checking of automatic safety shutter operation for serviceability and adjusting for proper operation, checking of cross bar assembly, fixed contacts and current carrying parts of the breaker , cleaning/decarbonizing of all fixed and moving contacts, levers, springs, etc with soft emery paper , CRC solution and soft dry cloth to remove all carbon deposits and tightening all screws, nuts, bolts, spring etc and incl applying superior quality petrolium jelly on all contacts, checking of safety/tripping relays and wiring circuits, checking, setting and adjustment of rack in/rack out , spring charging system and operation of the breaker trolley, lubrication and greasing of breaker operating mechanism , all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear etc, checking of all end terminals, tightening of all earth connections, tightening all hardware, rack-in the breaker, put in position, engage the VCB with the supply system and testing for smooth functioning. Notes: (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape etc. and testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and filling for topping up insulating oil with dielectric strength not less tha 50 KV complete all as directed.
Supply and fixing in repairs tripping coil assembly 24 volts DC suitable for 11 KV HT VCB of any make and as per existing size/type complete all as specified and directed.
Supply and fixing in repairs closing coil assembly 24 volts DC suitable for 11 KV HT VCB of any make and as per existing size/type complete all as specified and directed.
Supply only Rack in Rack Out Handle as per existing size, type and suitable for 11 KV VCB of any make/type complete all as specified and directed.
Supply only Spring Charging Handle as per existing size, type and suitable for 11 KV VCB of any make/type complete all as specified and directed.
S & F in repairs HT 11 KV barrel fuses along with fuse element and metal parts suitable for up to 100 amps capacity complete all as direceted
Supply and fixing in repairs spring loaded tulip contact, suitable for 800 amps 11 KV HT VCB of any make/type complete all as directed.
Supply and fixing in repairs spring loaded tulip contact, suitable for 1250 amps 11 KV HT VCB of any make/type complete all as directed.
Laying only in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables with aluminium conductor, 11 KV grade and size 95 sqmm 3 core to 240 sqmm 3 core complete all as specified.Note - Serviceable cable obtained from item No 13 here in before shall be reused.
S & F danger notice board made from 3 mm thick MS sheet size 300 x 300 mm , painted with two coats of red synthetic enamelled paint over a coat of red oxide primer and writing work with white paint all as specified, necessary fixing arrangement with pole complete all as specified and directed.
M & L for sub class 'B' bricks for cable protection laid flat complete all as specified and directed.
M & L chequred rubber mat for electrical purpose ISI marked of size 1 mtr X 2 mtr and 19 mm thickness complete all as specified and directed.
S & F lightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed.
S & F in replacement MCCB 630 amps FP 415 volts 50 Hz with adjustable thermal and magnetic release, phase separators ccomplete all as specified and directed.
M/S BALWINDER SINGH
R D Bansal
Goblin Electric Co.
Raman Electric Trading Co
SHARMA ELECTRICAL ENGINEERS
kailu construction co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .