Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹23.9 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹24.0 L+₹9,663.18 (0.40%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹24.4 L+₹45,900.07 (1.92%)Admitted-Finance | L3 | Admitted-Finance |
Tender Value
₹24.2 L
EMD Value
₹48,320
Closing Date
16 Nov 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Officer
Nagar Palika Mundawar
Repair work for the mini high-mast light installed in the Mundawar Municipality
2026_DLB_605656_1
npm/2115
Open Tender
Miscellaneous Works
Percentage
30 days
Nagar Palika Mundawar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Eo, MDRISL
₹48,320
Yes
26 Nov 2026
7 Nov 2026
17 Nov 2026
7 Nov 2026
16 Nov 2026
7 Nov 2026
60 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each .
Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff
@>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver
compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture
shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with
this BSR .High Power LED Flood Light Minimum lumen output 30000 lm | 120 | nos | 19,267 | ₹23,12,040 |
| 2 | Supplying and drawing FR PVC insulated & unsheathed flexible
copper conductor as per PWD specification for electrical Works with
ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire
should be made from 99.90 % purity copper, class 5 stranding in
acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less
chances of oxidization, insulation PVC type A/C/D , flame retardant
as per IS 10810-53, better amperage rating as per IS:3961 part 5, in
existing surface or recessed PVC/ MS conduit/casing capping
making connections with Copper Lugs of suitable size,
Ferrules,testing etc. as required. OEM Must have its own in house
NABL lab setup for all testing facilities for wires. For additional
technical parameters of product / work refer Annexure 'A' attached
with this BSR2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. | 170 | mtr | 190 | ₹32,300 |
| 3 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed
Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -
I of 1.1 KV with H4- Grade electrolytic aluminium conductor
confirming to IS 8130 of purity >99.6 %, round / flat strip armouring
of cables, Inner / outer sheath confirming to IS:5831 in existing RCC
/ Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable
tray(with cable tie) including testing etc. as required of following
size. OEM must have it's own in house NABL accrediated
Laboratory for testing procedure as per IS:10810.For additional
technical parameters of product / work refer Annexure 'A' attached
with this BS 16 x 4.0 Sq. mm | 300 | mtr | 238 | ₹71,400 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.26 MB
BOQ_1074004.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .