Supply installation testing and commissioning of Signalling material in connection with :- Provision of S&T work for Extension of Line 4 and 7 at Bangrod station.
SnT_RTM_26_13_Signal
SnT_RTM_26_13_Signal
Open
9 Months
Ratlam, Madhya Pradesh
₹0
₹1.2 L
25 May 2026
25 May 2026
2 Jun 2026
Item Breakup - NS-NS Schedule
Disconnect Terminal Block, Screw less type, as Numbers per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. (i)Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two output) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3)
Disconnect Terminal Block, Screw less type, as Numbers per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. (ii)Supply of End plate for above item (I) 2.5mm/0.091 in thick as per site requirement. RATLAM DIVISION-S AND T/WESTERN RLY
Disconnect Terminal Block, Screw less type, as Numbers per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. (iii)Supply of End Stopper for above item (I) 10mm/0.0394 in width as per site requirement.
Disconnect Terminal Block, Screw less type, as Metre per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. (iv)Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness unslotted type as per site requirement.
Key Lock Relay working on 24V DC, AC Numbers Immunized with different ward combinations (Three ward plates to be supplied with each relay).
Relay QSPA1, 24VDC, Slow to pick up, 8F/4B Numbers along with plug board, retaining clip and connectors. Conforming to BRS: 933A, IRS:S60, IRS:S34 & IRS:S23.
Track relay QTA2, AC immunized, 9 Ohm, Numbers 4F/2B, along with plug board, retaining clip and connectors conforming to BRS:939A, BRS:966, IRS:S34 & IRS:S23.
Single core multi-strand wire 0.5 sq.mm. (16 Kilometre conductor each dia. 0.2mm), as per IRS 76/89 (Amd3).
Colour Light Signal Complete. This includes: - Numbers (1). Post Tubular 140 mm Dia, as per IRS: S- 6/81 or Latest & RDSO Drg. No. SA-24625 (Advance). (2). CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M with latest assembly). ( 3 ) . Pinnacle.(4). Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder.(5). Signal Front Staging Complete Assembly for CLS Unit.(6). Signal back staging as per extent WR PracticeNote: Height of the Post shall be 5.5 Mtr. Long.
Offset brackets for Main Signal, made of Numbers tubular steel, outer diameter 140 mm, thickness of pipe 4.5 mm. horizontal length of pipe 545 mm & vertical length of pipe 324 mm with fixing arrangement on Main Signal p o s t as per Drawing No SW/554/G/R
Non Metallic (FRP) colour light signal housing Numbers multi unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Ver. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.
Non Metallic (FRP) colour light signal housing Numbers multi unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Ver. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.
Position Light Shunt Signal Unit Complete with Set Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990, Base, Hood, Cover etc as per Drg. No. SA- 23840 suitable for LED Signal Lighting Unit(Supply of LED Unit is not covered in this item). RATLAM DIVISION-S AND T/WESTERN RLY
Calling ON Signal Unit with Brackets & Fixing Numbers accessories. Calling On Signal Unit shall conform to RDSO Drg no 24351(Adv) Alt1 suitable to LED Signal Lighting Unit.
Track Lead Junction Boxes as per C.Rly Drg. Numbers No.RST 11509 made from fiber glass along with terminal blocks.
Choke Coil for Single Rail Track Circuit on 25 Numbers KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments.
Adjustable Track Feed Resistance disc type 30 Numbers ohms as per RDSO Drg. No. SA 20166/M (Adv) with latest amendments (with Phenolic moulded base).
Track feed battery chargers, 110V AC input, 2 Numbers to 6 V DC Output; as per Specn.No. IRS:89/2025 Ver 2.0 date 14.06.2026 with latest amendments. Charger shall be suitable for charging 80 AH battery.
Channel Pins MS (Galvanized) single groove, 7 Numbers 10000.00 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M.
GI wire 8 SWG (4mm dia) suitable for track Kg circuit rail bonding.
Supply of High frequency Digital Axle Counter Set Multi section (iv)Double Rail contact assembly with track side EJB for MSDAC. Make Eldyne .Each set shall consist of track side Electronic unit, Double rail contact with cable and mounting accessories. This item shall be procured from RDSO approved firm and inspected by RDSO
Apparatus Case Single NE Rly Type as per Drg. Numbers No.W. Rly/SW/47/68 Alt-A, fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377Note: This item includes the supply & fixing of 2 Nos E Type Lock fitted on both doors, along with two Keys.
Apparatus Case half NE Rly Type as per Drg. Numbers No. W. Rly/SW/47/68 Alt-A fitted two nos E Type lock of (ward No will be specified by Engineerin Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377. Note: This item includes the supply & fixing of 2 Nos E Type Lock fitted on both doors, along with two Keys.
ARA Terminal blocks with links made of PBT Numbers Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.
Cartridge fuse block made of PBT as per RDSO Numbers Drg No SA- 23748 Alt 4 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. This also includes supply of equivalent no of ND type Fuses of 2A capacity as per specification IRS S-78/92.
Round head type non detoriating type low Numbers voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. RATLAM DIVISION-S AND T/WESTERN RLY
Maintenance Free Earth Electrode of length Set 3m, including supply of 3 bags of Earth enhancement material for earthling (20KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197 ver 2.0 or latest & as per latest RDSO earthing TAN.
Medium Class G.I. Pipes to IS : 1239 (Pt.I)-2004 Metre or latest ; 100mm dia. ( int. dia) 3.65 m m + / - 10% thick with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes.
Double Walled Corrugated (DWC) HDPE Pipe Numbers with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring2) Spacers3) Tees4) Bend,5) End-cap(The total quantity of above items is equal to no. of pipes supplied.)DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified.
Supply of multi lamp LED Numeric Route Numbers indicatorswith ECRs. Double digit type from 0 to 19 white LEDand as per the instruction of engineering in-charge.
Supply of Universal Hand cuff lock as per Numbers Instruction ofEngineer In charge.
Supply of Drill bits 7.2 mm as theinstruction of Engineering incharge.
Supply of Split DWC Pipe Confirming to Running RDSO/SPN/204/2011 ver 1.0 or latest, Non Metre Metallic, anti-rodent & non-flame propagating type in 2 Meter length of size 200 mm outer dia and 175 mm inner dia. Split DWC pipe shall be marked at every 1mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange
Supply of Web detector (Tx/Rx Coil) for Numbers ELDYNE make digital axle counter as per instructions of engineering incharge. Total 4747576.30 Item- 2 B Execution Items S No. Item Description of Item Unit Qty Rate Amount No
Circuit diagrams in the relay racks/IDF rack tag blocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder resin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways. RATLAM DIVISION-S AND T/WESTERN RLY
Charging of Lead Acid Batteries with Numbers contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of W.Rly & instruction of Engineer- incharge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge.(i)2V 80AH
Excavation and Casting of foundation for main Numbers signal post as per CSTE/3122 (WR) with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.
Erection of CLS Post with base and signal unit Numbers on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates / boards if any with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In- Charge at site. The Item includes cutting of Signal post if required by Site In charge. (i)2/3/4 aspect signal unit mounted on offset bracket with junction type route indicator 1/2/3 on multilamp lamp route indicators mounted on signal post
Erection of CLS Post with base and signal unit Numbers on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates / boards if any with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In- Charge at site. The Item includes cutting of Signal post if required by Site In charge. (ii)2/3/4 aspect signal unit mounted mounted directly on signal post
Excavation and Casting of foundation for Numbers Shunt Signal as per Drg. No. CSTE/6090 with Contractor's own materials including Cement and Anchor Bolts of Standard Size. The required scaffolding, Ferma etc for Casting of foundation will have to be brought by the Contractor at his own cost.
Erection of Position Light Shunt signal with Numbers Base, Post, Signal unit and fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site.
Fixing of Junction type Route Indication 1- Numbers Way/2-Way/3- Way on the top of the signal post.
Fixing of Calling-on Signal/ASign/ AG-Sign unit Numbers on signal post. The item includes fixing of Co- On signal /'A' sign/ 'AG' sign unit on signal post with bracket, hood etc. Item includes supply bracket & fixing materials etc. by the contactor. The item also includes termination of cables & wiring inside Co- On signal /'A' sign/ 'AG' sign unit as per standard practice. RATLAM DIVISION-S AND T/WESTERN RLY
Fabrication and fixing of Signal Number Plate( Numbers CSTE Drg No CSTE/6186) , 'A' Marker (Drg No. CSTE/6180), 'AG' Marker (Drg No. CSTE/6181), 'P' Marker (Drg No. CSTE/6182), Arrow Marker (Drg No. CSTE/6183), 'G' Marker (Drg No. CSTE/6184), 'C' Marker (Drg No. CSTE/6185). marker disk on signals as per standard practice All material required for this work shall be supplied by Contractor.
Supply & Fixing of Protective screen of Numbers expanded metal 12 SWG of Size 1200 X 1500 mm on Signaling as per standard practice for protecting against voltage in AC Traction area as per instruction of Engineer In Charge.
Installation of DC track circuits covering points Numbers zones also. The item includes provision of continuity bonds of seven strand PVC jacketed wire/ GI wire 8 SWG on rail joints after drilling bond-hole of 7.0/7.1/7.2mm dia (double bond with sleeves and rail clips are to be provided at each rail joint), insertion of insulated block joint, fixing of Track lead Junction box on MS angle two numbers of size 40X40X5 mm 1200 mm length for track feed/ jumper / track relay ends of track CCTs (as per double TLJB arrangements) and also for fixing jumper cables as per insulation diagram WR Drg No. CSTE/6055 and standard practice, making rail connections through suitable insulated sleeves from Track lead Junction box at TF, jumper & TR end with seven strand PVC jacketed wire /GI wire 8 SWG , rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on bootleg terminals etcTF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of H o o k s . Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins etc. The item also includes supply of MS angles / trestles, GI wire 8 SWG / seven strand PVC jacketed wire, hooks, rail clips e t c . (Supply of insulation material for block joint & Boot leg is covered in Schedule separately or will be supplied by Railways).
Fixing and wiring of DC track circuit Per Track equipments i.e. track feed charger, resistance, Circuit track relay, battery, etc., in the Apparatus Case and battery box as per standard practice. Termination of tail cable on M 6 / Screw less terminals WAGO or FINOLEX or similar approved make teminals/ fuse blocks / HRC fuse. Item includes testing /commissioning of track circuit. Complete wiring material will be supplied by contractor(Supply of Track feed battery charger, track feed battery, resistances & 'B' type choke & Track relays will be supplied by Railways / covered in Schedule separately).
Erection, Fitting and Rail connection of Track Numbers Lead Junction Box on two supports (M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm lengthThis will include drilling of holes for track lead/side connections on rail. The work shall be done as per Drg. No. S&T/Const./JHS/T 115 & instructions of Rly engineer at site. RATLAM DIVISION-S AND T/WESTERN RLY
Installation of track device (double rail Numbers contact) including digging of trench, track crossing, laying of antirodent, anti-oxidant & nonflame propagating type Double Walled Corrugated (DWC) pipe as per IS- 14930 part- I or II or latest and all other accessories as per site requirement to be for laying of transmitter and receiver cableThe item also includes installation of EJB / Track side Electronics including foundation & earthing as per OEM's guidelines and Technical requirement & specificationNOTE: Installation/ programming/ configuration/ commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorized representative of OEM.
Fixing of Electrical Point Machine on the Numbers extended sleepers at points as per std. practice and as per RDSO Drg No. SA 91 51-52 or 9710 or 9161 as per section of rails u s e d . Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle.The item also includes :(i)Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers(ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be Provided by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on WR and the instruction of Railway Engineer at site.(v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine. Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-incharge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard l a y o u t . Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately.
Excavation and Casting of Apparatus Case Numbers foundation w i t h contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(i)Single Case as per Drg No SK 748 or CSTE/5074
Excavation and Casting of Apparatus Case Numbers foundation w i t h contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(ii)Half Case as per Drg No SK 747or CSTE/5074 or SS Location RATLAM DIVISION-S AND T/WESTERN RLY
Installation of Apparatus Cases with miniature Numbers 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. (i)Single Case
Installation of Apparatus Cases with miniature Numbers 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. (ii)Half Case
Digging of cable trench 0.3 Mtrs. Deep and 0.3 cum Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.
Horizontal direction drilling/boring without Metre damage of surface road using Auger Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. this include insertion of different dia DWC pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Pipe will be supplied by railway. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damaged due to rough handling & pressure on cable"
Placing of DWC/RCC/GI pipes along with collars Metre in trenches at places of track and road crossings, platform cuttings etc.
Fixing of GI pipes for crossing the culverts, Metre bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
Laying of S&T Cables of various cores/ pairs/ Metre quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
Supply and installation of RCC cable route Numbers marker engraved and painted on both side along the route every 50 M and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker.
Cement concrete work for miscellaneous items cum in the ratio 1 : 3 : 6 . Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor) RATLAM DIVISION-S AND T/WESTERN RLY
Providing brick masonry in ratio 1:6 cement cum and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.
Removal of Rail (13 mtrs.) in the way of cable Numbers route. In case of panel (39 Mtrs. Each) will be considered as three rails for payment purpose.
Removal of PRC Sleeper in the way of cable Numbers route.
Transferring of Signaling/Telecom cables from Set existing Location box to New Location box . The work include breaking/ Dismantling of Existing foundation of locations, excavating and removing / segregating coils of 2C/6C/12C/19C/24C/30C/Quad cables which may be about 10 mtrs. in length. These cables are to be disconnected and removed from the existing location one by one as per the instruction and under the supervision of Railway staff present at site. The cable is then to be inserted and terminated in new location box. The item includes neatly dressing of cable, making wiring tree etc.The material required to dressing /lacing will be arranged by contactor. The work is required to be done systematically and with due precaution during the block or disconnection within the time that may be allowed. The excavation work to be done carefully without damaging the cable to avoid undue failure. (Termination charges will be given separately). Note: Proportionate payment will be made if cable of other length. One No unit = One cable of 10 m length)
Shifting of Exposed cables. The item includes Kilometre Removal of exposed cable from existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe covered separately.
Earthwork in filling in embankment, guide cum bunds, around buried type abutments, bridge gaps, trolley refuges, rain bunds if provided, platforms etc. with earth excavated from outside railway boundary entirely arranged by the contractor at his own cost as per RDSO's latest guidelines and specifications and special condition of contract including all leads, royalty, lifts, ascents, descents, crossing of nallahs or any other obstructions. The rates shall include all dressing of bank to final profile, demarcation and setting out of profile, site clearance, removing of shrubs, roots of vegetations growth, heavy grass, benching of existing slope of old bank, all handling/re- handling. Taxes, Octroi and royalty etc. as a complete job. Cut trees shall be property of railways and to be deposited in the railway godown unless specified otherwise in the Special conditions of contract RATLAM DIVISION-S AND T/WESTERN RLY
Dismantling / Releasing of existing Signaling Numbers Gears. One Signalling gear will be all parts of one signal (consisting of CLS unit, Signal post along with base) or lever frame (5 levers set), or one point (consisting of all parts of a mechanical point, point machine, ground connections etc.) or one track circuits (consisting of battery box & other parts of DC Track circuit / AFTC /DAC) or one Block instruments etc. This includes the cost of transportation of release materials to store depot or as decided by consignee in charge. This work to be done by contactors with his own vehicle and labour(Rate to be considered when total gear to be dismantled at a station is more than 10)"
Installation Electrode for Maintenance free earth spec of RDSO/SPN/197/ ver 2.0 or latest & as per RDSO latest TAN.
Supply & Fixing of KLCR boxes in field and/or Numbers inl ocation boxes and in SM office asper site requirement. The KLCR boxes will beof appropriate size as per instructions ofEngineer incharge and it should be made ofhylam /wooden (teak wood) of high quality asper the requirement. Item includes supply ofany minor bracket nuts, bolts & holes drillingMS angles, MS plates etc. It also includes fixingof KLCR relays in the boxes where required.
Supply of Fiber glass reinforced plastic Numbers Platesof size-530x960x10 mm as per instructionof Engineer-incharge.
Supply, commerciallyavailable Compact water resistanceLaminated Sheet 10 mm thick for keepingS&T equipments as per the Instruction ofEngineerincharge. This item includes supplyand fabrication/ fixing of allmaterials like laminated sheet, Nuts and bolts,fixing arrangements along with fabrication oftables for keeping equipments like reset box,Block panel and fabrication of Key box and/ orany type of box/ table box for keepingequipments etc. can also be got fabricatedunder this item as per the design givenby engineer in charge.
Supply, Fabrication & fixing of hylam sheet Sqm ofsize 10mm thick (other dimension i.e. lengthand breadth will be decided by Engg- incharge)for A/case NE typebyproviding allfixtures including fixing of PVCcoatedStringRods at the back side for cablesupportwithcontractor own materials. Theitem includes fixing of M6 terminals or screwless /fuse blocks /HRC fuses ND typeon eachstrip. Two extra holes on both sidesof M6 terminals or screw less/ fuse blocks /HRCfuse and two extra holes for fixing the sheet.Note: (i) The complete hylam sheet to becovered with either M6terminals orscrew less/fuse blocks /ND type HRCfuses asper instructions of engineer at site. (ii)Hylam sheet to be of grade P2. (iii) M6terminals or screwless, HRC fuses willbesupplied by Railway. The above item alsoincludes fixing of Q series (GPR) relays. RATLAM DIVISION-S AND T/WESTERN RLY
Termination of cable cores on ARAterminal/ Numbers fuse blocks,8 way terminals block/Screwless connectors in the apparatus cases/cable termination rack at both ends.Bothends of a cable core terminated shallbe countedas one terminal. This includes allassociated works of pulling out the cable fromunderground. The item includes dressing ofcables, making wiring tree etc. The work shallbe done as perLocation/Cable termination plans and as perthe instruction of Engineer-incharge.
Earthing and soldering of cable armour inside Numbers appartus cases and other locations.
Installation, fixing and wiring of LED Numbers signallighting unit inside all types of Signal units. Italso includes complete wiring in signal unitand location boxes/ hutas per approveddrawing and as per instruction of Engineer incharge. Note: LED Signal Unit will be suppliedby Railways. Total 1495430.14
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_1.pdf
ATTACHMENT
GCCACS.pdf
ATTACHMENT
GCCApril2022ACSNo_11.pdf
ATTACHMENT
ACS-2toGCC-2022.pdf
ATTACHMENT
GCCApril2022ACSNo_3_1.pdf
ATTACHMENT
GCCApril2022ACSNo_4.pdf
ATTACHMENT
GCCApril2022ACSNo_5.pdf
ATTACHMENT
GCCApril2022ACSNo_6.pdf
ATTACHMENT
TenderdocumentBOD.pdf
ATTACHMENT
AppendixBOD.pdf
ATTACHMENT
GCCApril2022ACSNo_7.pdf
ATTACHMENT
approvedESPBOD090326.pdf Approveed ESP Bangrod
ATTACHMENT
GCCApril2022ACSNo_8.pdf
ATTACHMENT
GCCApril2022ACSNo_9.pdf
ATTACHMENT
GCCApril2022ACSNo_10.pdf
ATTACHMENT
approvedESPBOD090326.pdf
ATTACHMENT
Download all tender documents and submit your bid