Comprehensive External Development, Horticulture, Landscaping and other miscellaneous works for College of Veterinary and Animal Sciences and College of Fisheries Under Pkg-3 for RLBCAU, Datia, MP
NBCC/CPG/RLBCAU/Datia/Pkg-3/2021/300
NBCC/CPG/RLBCAU/Datia/Pkg-3/2021/300
Open Tender-Domestic
Civil Works General
Datia, Madhya Pradesh
₹59,000
Exempted
14 Sept 2021
14 Sept 2021
5 Oct 2021
5 Oct 2021
16 Nov 2021
ABSTRACT OF COST
AMOUNT(IN RS) AS AMOUNT(IN RS) Total of DSR Items
S.NO. DESCRIPTION
PER DSR-2018 NON DSR ITEM + Non DSR Items
HORTICULTURE AND LANDSCAPING
SAY (IN LACS) B 4794.92 lacs
GAURAV Digitally signed by GAURAV
RAVINDRA GAIKWAD
RAVINDRA Date: 2021.10.01 12:25:16
NBCC (INDIA) LTD
“Comprehensive External Development, horticulture, landscaping and other miscellaneous works for College of
Veterinary and Animal sciences and College of Fisheries under Pkg-3 for RLBCAU, Datia, MP “
ABSTRACT OF COST - External Development Works
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
SCHEDULE ITEMS:
Carriage of Materials
Removal- By mechnical transport including loading, unloading & stacking
1.1.4 Excavated rock
Earth work in excavation by mechanical means (Hydraulic excavator)/manual
means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on
2.6 plan) including getting out and disposal of excavated earth lead upto 50 m and lift
upto 1.5 m, as directed by Engineer-in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual
means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on
2.7 plan) including getting out and disposal of excavated earth lead upto 50 m and lift
upto 1.5 m, as directed by Engineer-incharge.
2.7.3 Hard rock (blasting prohibited) cum 383.50 1016.20 389712.70
Earth work in excavation by mechanical means (Hydraulic excavator) /manual
means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm
on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m,
2.8 including getting out the excavated soil and disposal of surplus excavated soil as
directed, within a lead of 50 m.
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm in depth,consolidating each
2.25 deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. cum 5472.63 219.65 1202063.18
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or
2.26 stacked materials.
2.26.1 All kinds of soil. Cum 638.70 90.40 57738.48
Supplying and filling in plinth with sand under floors, including watering, ramming,
2.27 consolidating and dressing complete. Cum 700.00 1953.05 1367135.00
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees
and saplings of girth up to 30 cm measured at a height of 1 m above ground level
2.31 and removal of rubbish up to a distance of 50 m outside the periphery of the area sqm 10058.10 12.55 126229.16
Providing and laying in position cement concrete of specified grade excluding
4.1 the cost of centering and shuttering - All work up to plinth level :
"1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20
mm nominal size).
1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone
4.1.8 aggregate 40 mm nominal size) cum 1572.09 5789.60 9101772.26
Providing and laying cement concrete in retaining walls, return walls,walls (any
thickness) including attached pilasters, columns, piers,abutments, pillars, posts,
struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor
4.2 blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding
the cost of centering,shuttering and finishing :
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate
Centering and shuttering including strutting, propping etc. and removal of form
4.3 work for :
4.3.1 Foundations, footings, bases for columns Sqm 1186.36 284.85 337934.65
Reinforced Cement Concrete
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Reinforced cement concrete work in walls (any thickness), including
attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars,
5.2 piers, abutments, posts and struts etc. above plinth level up to floor five level,
excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone
5.2.2 aggregate 20 mm nominal size) Cum 5.34 9306.00 49694.04
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and
Columns, Pillars, Piers, Abutments, Posts and Struts
Edges of slabs and breaks in floors and walls
Under 20 cms wide
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) :
4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild
steel wire, including centering and shuttering, roughening cleaning, fixing and
5.18 finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding
plastering of the jambs, sills and soffits.
Steel reinforcement for R.C.C. work including straightening, cutting, bending,
5.22 placing in position and binding all complete upto plinth level
Thermo-Mechanically Treated bars
Steel reinforcement for R.C.C. work including straightening, cutting, bending,
5.22A placing in position and binding all complete above plinth level 0.00
Thermo-Mechanically Treated bars of grade Fe-500 D or more.
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing and laying in position machine batched and machine mixed design mix
M-25 grade cement concrete for reinforced cement concretework, using cement
content as per approved design mix, including pumping of concrete to site of
laying but excluding the cost of centering, shuttering, finishing and reinforcement,
including admixtures in recommended proportions as per IS: 9103 to accelerate,
retard setting of concrete, improve workability without impairing strength and
5.33 durability as per direction of Engineer-in-charge.“(Note :- Cement content
considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design
mix is payable/recoverable separately).
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess / ess
uptoas per design
plinth level mix is payable/recoverable separately). Cum 868.26 7997.30 6943735.70
5.33.2 All works above plinth level upto floor five level Cum 168.82 9400.85 1587051.50
Add for using extra cement in the items of design mix over and above the
5.35 specified cement content therein. quintal 1724.18 673.30 1160890.39
Brick work with common burnt clay F.P.S ( non modular ) bricks of class
6.1 designation 7.5 in foundation & plinth in:
6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) Cum 172.50 6376.25 1099903.13
6.1.2 Cement mortar 1:6 (1 cement: 6 coarse sand) Cum 914.42 6157.45 5630495.43
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Brick work with common burnt clay F.P.S. (non modular) bricks of class
6.4 designation 7.5 in superstructure above plinth level up to floor V level in all
shapes and sizes in :
6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) Cum 82.80 7809.25 646605.90
6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 239.04 7590.45 1814421.17
Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm
thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in
white cement with an admixture of pigment to match the stone shade.
7.38.1 8mm thick (mirror polished and machine cut edge)
7.38.1.1 Granite stone of any colour and shade sqm 17.01 2537.40 43161.17
Random rubble masonry with hard stone in foundation and plinth including
levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded
stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Random rubble masonry with hard stone in superstructure above plinth level and
Derived upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement :
from 7.2.1 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills,
and 16.27 ceiling level and the like.
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills,
facias and similar locations of required size, approved shade, colour and texture
8.2 laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints
treated with white cement, mixed with matching pigment, epoxy touch ups,
including rubbing, curing, moulding and polishing to edges to give high gloss
finish etc. complete at all levels.
8.2.2 Granite of any colour and shade
Area of slab over 0.50 Sqm
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc.,
including machine polishing to edge to give high gloss finish etc. complete as per
8.3 design approved by Engineer-in-Charge.
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineer-
in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement
8.31 mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ sqm 82.28 1030.30 84773.08
3.3kg per sqm, including pointing in white cement mixed with pigment of matching
Wood and PVC Work
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass
panes 4 mm thick in doors, windows and clerestory window shutters. (Area of
9.12 opening for glass panes excluding portion inside rebate shall be measured). Sqm 1.44 214.05 308.23
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)
non-decorative type, core of block board construction with frame of 1st class hard
9.21 wood and well matched commercial 3 ply veneering with vertical grains or cross
bands and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges
with necessary screws
Extra for cutting rebate in flush door shutters (Total area of the shutter to be
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
9.48 flats, square or round bars etc. including priming coat with approved steel primer all
Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic
coating not less than grade AC 10 as per IS : 1868), transparent or dyed to
required colour or shade, with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating
not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required
9.97 colour or shade, with necessary screws etc. complete :
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less
than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with
9.100 necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to
9.101 required colour and shade, with necessary screws etc. complete.
9.101.1 Single rubber stopper each 3.00 33.95 101.85
9.101.2 Twin rubber stopper each 1.00 62.05 62.05
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain
in gloss / matt/ suede finish with high density protective surface layer and reverse
9.127 side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of
adhesive of approved quality.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and
3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete,
10.5 including applying a priming coat of approved steel primer.
10.5.2 Using flats 30x6mm for diagonal braces and central cross piece. sqm 2.31 4,278.15 9882.53
Supplying and fixing rolling shutters of approved make, made of required size
M.S. laths, interlocked together through their entire length and jointed together at
the end by end locks, mounted on specially designed pipe shaft with brackets,
side guides and arrangements for inside and outside locking with push and pull
10.6 operation complete, including the cost of providing and fixing necessary 27.5 cm
long wire springs manufactured from high tensile steel wire of adequate strength
conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling
10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover Sqm 15.75 2944.10 46369.58
10.7 Providing and fixing ball bearing for rolling shutters. each 10.00 419.85 4198.50
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead
10.9 of laths as per design approved by Engineer-in- charge, (area of grill to be measured). sqm 4.13 668.95 2762.76
Extra for providing and fixing steel beading of size 10 x 10 x 1.6 mm (box type), approved
shape and section with screws instead of glazing clips and metal sash putty, in steel
10.12 doors, windows, ventilators and composite units.
Providing and fixing pressed steel door frames conforming to IS: 4351,
manufactured from commercial mild steel sheet of 1.60 mm thickness, including
hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle
of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly
fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm
10.14 thick with mortar guards, lock strike-plate and shock absorbers as specified and
applying a coat of approved steel primer after pre-treatment of the surface as
directed by Engineer-in-charge:
10.14.3 Profile E
Fixing with adjustable lugs with split end tail to each jamb
Steel work in built up tubular (round, square or rectangular hollow tubes etc.)
trusses etc., including cutting, hoisting, fixing in position and applying a priming
10.16 coat of approved steel primer, including welding and bolted with special shaped 0.00
washers etc. complete.
10.16.2 Hot finished seamless type tubes Kg. 7767.06 157.50 1223311.95
Steel work welded in built up sections/ framed work, including cutting, hoisting,
10.25 fixing in position and applying a priming coat of approved steel primer using
structural steel etc. as required
In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing, polishing
and making curvature (wherever required) and fitting the same with necessary
stainless steel nuts and bolts complete, i/c fixing the railing
with necessary accessories & stainless steel dash fasteners , stainless
10.28 steel bolts etc., of required size, on the top of the floor or the side of waist slab Kg. 1100.00 575.45 632995.00
with suitable arrangement as per approval of Engineer-incharge, (for payment
purpose only weight of stainless steel members shall be considered excluding
fixing accessories such as nuts, bolts, fasteners etc.).
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S.
10.29 Flat 15x3 mm and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate) finished with a floating coat of neat cement, including cement
11.3 slurry, but excluding the cost of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone aggr. Sqm 9.60 498.35 4784.16
52 mm thick cement concrete flooring with concrete hardener topping, under layer
40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener
consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm
11.5 nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of Sqm 40.00 854.30 34172.00
cement or as per manufacturer's specifications. This includes cost of cement
slurry, but excluding the cost of nosing of steps etc. complete..
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed
with grey cement slurry mixed with pigment to match the shade of the slab,
11.26 including rubbing and polishing complete with base of cement mortar 1 : 4 (1
cement : 4 coarse sand) :
Providing and laying Polished Granite stone flooring in required design and patterns, in
linear as well as curvilinear portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement
11.56 mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing
with white cement slurry admixed with pigment of matching shade including rubbing ,
curing and polishing etc. all complete as specified and as directed by the Engineer-in-
Polished Granite stone slab jet Black, Cherry Red, Elite Brown,
Cat Eye or equivalent.
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing corrugated G.S. sheet roofing including vertical / curved
surface fixed with polymer coated J or L hooks, bolts and nuts 8
mm diameter with bitumen and G.I. limpet washers or with G.I. limpet
washers filled with white lead, including a coat of approved steel
12.1 primer and two coats of approved paint on overlapping of sheets
complete (up to any pitch in horizontal/ vertical or curved surfaces),
excluding the cost of purlins, rafters and trusses and including cutting
to size and shape wherever required.
12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m² Sqm 290.00 1234.25 357932.50
Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1
cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of
cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished
With common burnt clay F.P.S. (non modular) brick tiles of class designation 10
13.1 12mm cement plaster of mix :
15 mm cement plaster on the rough side of single or half brick wall of mix:
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat
13.16 6 mm cement plaster to ceiling of mix :
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1
13.11 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 Sqm 1726.98 399.30 689583.11
cement : 6 fine sand).
13.33 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :
13.33.2 Raised and cut pointing Sqm. 22037.40 520.75 11475976.05
Distempering with oil bound washable distemper of approved brand and
13.41 manufacture to give an even shade :
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
New work (two or more coats) over and including water
13.41.1 thinnable priming coat with cement primer Sqm 22158.90 153.45 3400283.21
Applying one coat of water thinnable cement primer of approved brand and
13.43 manufacture on wall surface :
13.43.1 Water thinnable cement primer Sqm. 22037.40 60.00 1322244.00
13.44 Finishing walls with water proofing cement paint of required shade
13.44.1 New work (two or more coats applied @ 3.84 Kg./10 Sqm) Sqm 109.64 91.25 10004.65
13.45 Finishing walls with textured exterior paint of required shade
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including
13.45.1 priming coat of exterior primer applied @ 2.20kg/10 sqm Sqm 1670.10 232.00 387463.20
Finishing walls with Acrylic Smooth exterior paint of required shade
New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming
13.46.1 coat of exterior primer applied @ 2.20 kg/10 sqm) Sqm 150.00 164.70 24705.00
Providing and fixing concertina coil fencing with punched tape
concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having
50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron
‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced
barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including
16.53 necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction metre 3498.00 290.80 1017218.40
of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm
thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and
weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Painting with synthetic enamel paint of approved brand and
13.61 manufacture to give an even shade :
13.61.1 Two or more coats on new work Sqm 2315.00 121.55 281388.25
13.62 Painting with synthetic enamel paint of approved brand and manufacture to give
or more : on new work
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic
Compound ) content less than 50 grams/ litre, of approved brand and
13.81 manufacture, including applying additional coats wherever required, to achieve
even shade and colour.
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing and laying in situ seven course water proofing treatment with APP (Atactic
Polypropylene) modified Polymeric memberane over roof consisting of first coat of
bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20
kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702,
3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0 mm
thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as
100 micron HMHDPE film sandwiched on both sides with polymeric mix and the
14.88 polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most Sqm 13.46 651.50 8769.19
layer shall be finished with brick tiles of class designation 10 grouted with cement mortar
1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight
of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand) and
finished neat (item of laying brick tiles shall be paid for separately).
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Preparation and consolidation of sub-grade with power road roller of 8 to 12 tonne
capacity after excavating earth to an average of 22.5cm depth, dressing to
16.1 camber and consolidating with road roller including making good the undulations Sqm 26145.25 156.75 4098267.94
etc. and re-rolling the sub-grade and disposal of surplus earth lead upto 50 mtr.
Extra for compaction of earth work in embankment under optimum moisture
16.2 conditions to give at least 95% of the maximum dry density Cum 7508.32 18.20 136651.42
16.3 Supplying and stacking at site:
Laying, spreading and compacting stone aggregate of specified sizes to WBM
specifications in uniform thickness, hand picking, rolling with 3 wheeled road /
vibratory roller 8-10 tonne capacity in stages to proper grade and camber,
16.4 applying and brooming requisite type of screening / binding material to fill up Cum 10127.48 767.25 7770309.03
interstices of coarse aggregate, watering and compacting to the required density .
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface
16.15 Supplying at site :
R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3
(1 cement : 1.5 coarsesand : 3 graded stone aggregate 12.5 mm nominal size) with
wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-incharge
16.15.1 (cost of earth works in excavation, concrete works in foundation to be paid separately). cum 120.54 26754.35 3224969.35
Fencing with R.C.C. post placed at required distance, embedded in
cement concrete blocks, every 15th post, last but one end post and corner post shall be
strutted on both sides and end post one side only, provided with horizontal lines and two
diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two
posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm
bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and
16.17 concrete to be paid for separately) :-
Payment to be made per metre cost of total length of barbed wire
16.17.1 With G.I. barbed wire metre 10000.00 12.00 120000.00
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing and applying tack coat using bitumen emulsion conforming to IS:8887,
16.31 using emulsion pressure distributer including preparing the surface & cleaning
with mechanical broom.
16.31.1 With rapid setting bitumen emulsion
16.31.1.2 On bituminous surface @ 0.25kg/sqm sqm 456.00 8.05 3670.80
Providing and laying seal coat over prepared surface of road with bitumen heated
in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade
VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size
(Passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 sqm of road
surface, including rolling and finishing with power road roller all complete.
Note : Seal coat items to be operated only with the prior approval of Chief
Engineer concerned.
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40
mm nominal size) in pavements, laid to required slope and camber in panels as
16.42 required including consolidation finishing and tamping complete. Cum 1292.21 6840.85 8839814.78
Providing and fixing in position pre-moulded joint filler in expansion per cm joints.
Providing and laying bituminous macadam using crushed stone aggregates of
specified grading premixed with bituminous binder, transported to site by tippers,
laid over a previously prepared surface with paver finisher equiped with electronic
sensor to the required grade, level and alignment and rolling with smooth
16.55 wheeled, vibratory and tandem rollers as per specifications to achieve the desired
compaction and density, complete as per specificatons and directions
of Engineer-in-Charge.
50 to 100 mm average compacted thickness with bitumen
of grade VG-30 @ 3.50% (percentage by weight of total
16.55.2 mix) prepared in Drum Type Hot Mix Plant of 60-90 TPH cum 319.05 7665.25 2445598.01
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing and laying semi- dense Bituminous concrete using crushed stone
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site by tippers, laying with paver finisher equiped
with electronic sensor to the required grade, level and alignment and rolling with
16.56 smooth wheeled, vibratory and tandem rollers to achieve the desired compaction
and density as per specification, complete and as per directions of Engineer-in-
25 mm compacted thickness with bitumen of grade VG-
30 @ 5% (percentage by weight of total mix) and lime
filler @ 2% (percentage by weight of Aggregate) prepared
in Drum Type Hot Mix Plant of 60-90 TPH capacity.
Providing and applying 2.5 mm thick road marking strips (retroreflective) of
specified shade/ colour using hot thermoplastic material by fully/ semi automatic
thermoplastic paint applicator machine fitted with profile shoe, glass beads
dispenser, propane tank heater and profile shoe heater, driven by experienced
16.62 operator on road surface including cost of material, labour, T&P, cleaning the road sqm 943.36 607.30 572902.53
surface of all dirt, seals, oil, grease and foreign material etc. complete as
per direction of Engineer-in-charge and accordance with applicable
specifications.
Providing and laying 60mm thick faciory made cement concrete interlocking paver
block of M -30 grade made by block making machine with strong vibratory
compaction, of approved size, design & shape, laid in required colour and pattern
over and including 50mm thick compacted bed of coarse sand, filling the joints
16.68 with line sand etc. all complete as per the direction of Engineer-in-charge. sqm 2190.75 859.35 1882621.01
Providing and laying at or near ground level factory made kerb stone of M-25
grade cement concrete in position to the required line, level and curvature, jointed
with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or
without grooves (thickness of joints except at sharp curve shall not to more than
16.69 5mm), including making drainage opening wherever required complete etc. as Cum 275.52 8376.15 2307796.85
perdirection of Engineer-in-charge (length of finished kerb edging shall be
measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer
dressed stones having no side less than 15 cm, with minimum depth of 20 cm
including preparing the bedding surface etc. all complete. (Payment for Stone to
16.73 be made separately). sqm 350.00 487.25 170537.50
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from
batching plant. The ready mixed concrete shall be laid and finished with screed
board vibrator , vacuum dewatering process and finally finished by floating,
brooming with wire brush etc. complete as per specifications and directions of
16.75 Engineer-incharge. (The panel shuttering work shall be paid for separately). Cum 2865.56 8663.05 24824489.56
(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less
cement used as per design mix is payable/ recoverable
Providing, laying, spreading and compacting graded stone aggregate (size range
53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including
premixing the material with water at OMC in for all leads & lifts, laying in uniform
layers with mechanical paverfinisher in sub- base / base course on well prepared
16.79 surface and compacting with vibratory roller of 8 to 10 tonne capacity to Cum 645.70 2641.40 1705551.98
achievethe desired density, complete as per specifications and directions of
Engineer-in-Charge.
Providing and laying factory made chamfered edge Cement Concrete paver
blocks In foot path, park & lawns driveway or light & traffic parking etc. of required
strength, thickness & size/ shape, made by table vibratory method using PU
mould, laid in required colour & pattern over 50mm thick compacted bed of course
sand, compacting and proper embedding/laying of inter locking paver blocks into
16.91 the sand bedding layer through vibratory compaction by using plate vibrator, filling
the joints with sand and cutting of paver blocks as per required size and pattern,
finishing and sweeping extra sand, all complete as per manufacturer's
specifications & direction of Engineerin- Charge
60mm thick Cement concrete paver block of M-35 grade with approved colour,
design & pattern.
80 mm thick C.C. paver block of M-30 grade with approved
16.91.2 color design and pattern. sqm 180.82 953.00 172321.46
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing and placing in position 100 mm thick factory made machine batched &
machine mixed Precast RCC Rectangular Covers on drains of footpath of various
sizes, of M-25 grade cement concrete for RCC work, including cost of centering,
shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum
100mm c/c on both ways , neat cement punning on finished surface, properly
encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted
16.93 over priming coat , reinforcement to be welded at edges with MS sheet and sqm 3640.32 2525.35 9193082.11
providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift,
handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing and laying non-pressure NP2 class (light duty) R.C.C.
pipes with collars jointed with stiff mixture of cement mortar in the
19.6 proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc. complete :
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of
19.19 required shape and approved quality
Circular shape 560 mm internal dia.
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/appropriate Z sections and other
sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at
junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene
21.1 gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as
per architectural drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/
pivots and making provision for fixing of fittings wherever required including the
cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium doors, windows, ventilator shutters &
partitions etc. with PVC/ neoprene gasket etc. complete as per architectural
thickness-Chage (Cost of aluminium snap
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Providing and fixing anodised aluminium grill (anodised transparent or dyed to
required shade according to IS: 1868 with minimum anodic coating of grade AC
15) of approved design/pattern, with approved standard section and fixed to the
existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to
centre, including cutting the grill to proper opening size for fixing and operation of
handles and fixing approved anodised aluminium standard section
around the opening, all complete as per requirement and direction of
Engineer-in-charge. (Only weight of grill to be measured for payment).
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing and mixing integral crystalline admixture for water proofing
treatment to RCC structures like basement raft, retaining walls,
reservior, sewage & water treatment plant, tunnels / subway and
bridge deck etc. at the time of transporting of concrete into the drum
of the ready-mix truck, using integral crystalline admixture @ 0.80%
(minimum) to the weight of cement content per cubic meter of
concrete) or higher as recommended by the manufacturer’s
specification in reinforced cement concrete at site of work. The
material shall meet the requirements as specified in ACI-212-3R-
2010 i.e. by reducing permeability of concrete by more than 90%,
compared with control concrete as per DIN 1048 and resistant to 16 bar
hydrostatic pressure. The crystalline admixture shall be capable
of self-healing of cracks up to a width of 0.50mm. The work shall be
carried out all complete as per specification and the direction of the
Engineer-in-charge. The product performance shall carry guarantee
for 10 years against any leakage.
Providing and applying integral crystalline slurry of hydrophilic in
nature for waterproofing treatment to the RCC structures like retaining
walls of the basement, water tanks, roof slabs, podiums, reservior,
sewage & water treatment plant, tunnels / subway and bridge deck
etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline
slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral
crystalline slurry : 1 part water) for horizontal surfaces and applying
the same from negative (internal) side with the help of synthetic fiber
22.23 brush. The material shall meet the requirements as specified in ACI-
212-3R-2010 i.e by reducing permeability of concrete by more than
90% compared with control concrete as per DIN 1048 and resistant
to 16 bar hydrostatic pressure on negative side. The crystalline slurry
shall be capable of self-healing of cracks up to a width of 0.50mm.
The work shall be carried out all complete as per specification and
the direction of the engineer-in-charge. The product performance shall
carry guarantee for 10 years against any leakage.
For vertical surface two coats @ 0.70 kg per sqm
For horizontal surface one coat @1.10 kg per sqm.
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing and applying crystalline mortar by mixing in the ratio of 4.5
: 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of
faulty construction joints, cracks, tie rod holes and spalled &
honeycombed surface of RCC underground structures like basement,
water tanks, bridge deck etc. to ensure water tightness. The crystallie
mortar shall conform to the EN 1504-3 having compressive strength
Class R4 > 45 MPa and adhesive bond strength Class R3 > 1.5
MPa. The work shall be carried out all complete as per specification
and the direction of the Engineer-In-Charge. The product performance
shall carry guarantee for 10 years against any leakage.
For sealing cracks and faulty construction joints, routed
out/making U-shape groove size 25x25mm and then
primed the area with integral crystalline slurry @0.05kg/
running metre and while the surface is tacky filled the
22.25.1 groove upto surface with crystalline mortar @1.50kg/ metre 174.80 525.70 91892.36
running metre. Once crystalline mortar is touch dry then
finally applied two coats of integral crystalline slurry
@0.05kg/running metre per coat.
For patching of tie rod holes, prepared tie rod hole surface
and then primed the area with integral crystalline slurry
@0.070kg/sqm and while the surface is tacky repair and
then filled the tie rod holes with crystalline each
22.25.2 [email protected] per hole. The crystalline mortar should 210.00 20.75 4357.50
be tightly rodded into tie rod holes or packed tightly (For
25x25x25 mm tie rod hole, use 0.040kg to fill the hole)
TOTAL OF SCHEDULE ITEMS 2339,30,457.72
NON- SCHEDULE ITEMS:
DESCRIPTION OF ITEM UNIT Quantity RATE (RS.) AMOUNT (RS.)
Providing fabricating and fixing of 6mm thick AHPL (High Pressure laminate)
sheets in standard size of 1200mm x 2400 mm (Sheets can be supplied in
customized length depending on requirement ).Sheets shall be manufactured
involving a series of mechanical process in a state-of-the art facility shall comprise
of 0.25 mm Aluminium skins on both sides sandwiching an LDPE ( Low Density
Poly Ethylene ) core having a density of 0.92 gm/cc giving the overall weight of
MR-1 HPL at 7.5kg/ sqm . Aluminum skins to have a desired lacquer in Lumiflon / PVDF sqm 737.87 5138.00 3791176.06
on one side. The supplied panels shall have a dexterity to be formed in convex
and concave shapes as also the ability to bend in 90 degrees under a mechanical
TOTAL OF NON-SCHEDULE ITEMS 37,91,176.06
NBCC (INDIA) LTD
“Comprehensive External Development, horticulture, landscaping and other miscellaneous works for College of
Veterinary and Animal sciences and College of Fisheries under Pkg-3 for RLBCAU, Datia, MP “
HORTICULTURE AND LANDSCAPING WORKS
Description of Item Unit Quantity Rate Amount
2.4 Supplying and stacking at site dump manure from approved
source, including carriage upto 5 km lead complete (manure
measured in stacks will be reduced by 8% for payment) :
2.4.1 Screened through sieve of I.S. designation 20 mm
2.6 Uprooting weeds from the trenched area after 10 to 15 days of
its flooding with water including disposal of uprooted vegetation.
2.8 Spreading of sludge, dump manure and/or good earth in
required thickness as per direction of officer-in-charge (cost of
sludge, dump manure and/ or good earth to be paid separately).
2.14 Digging holes in ordinary soil and refilling the same with the
excavated earth mixed with manure or sludge in the ratio of 2:1
by volume (2 parts of stacked volume of earth after reduction
by 20% : 1 part of stacked volume of manure after reduction by
8%) flooding with water, dressing including removal of rubbish
and surplus earth, if any, with all leads and lifts (cost of
manure, sludge or extra good earth if needed to be paid for
2.14.3 Holes 60 cm dia, and 60 cm deep
2.14.4 Holes 45 cm dia, and 45 cm deep
2.25 Supplying and stacking of well decayed cattle manure at site
including royalty and carriage upto 5 k.m. lead complete (Cattle
manure measured in stacks will reduced by 8% for Payment).
2.28 Preparation of mounds of various size and shape by available
excavated / supplied earth in layers not exceeding 20 cm in
depth, breaking clods, watering of each layer, dressing etc., lead
upto 50 meter and lift upto 1.5 m complete as per direction of cum 800.00 401.3 321040
Officer-in-charge.
2.33 Providing and fixing Neelgiri/Mexican grass turf with earthy
50mm to 60mm thickness of existing ground prepared with
proper level and ramming with required tools wooden
(Dhurmos) and than rolling the surface with light roller make
the surface smoothen and light, watering with sprinkler and
maintenance for 30 days or more till the grass establish properly
as per direction of officer incharge.
2.56 Anti termite treatment of lawn area through premise 30.50% I
P. one liter premise diluted in 499 liters water and applying
solution @ 1.00 litre solution per sqm lawn or bed area.(two
application) i/c cost of chemical)and as per direction of officer-in- sqm 35000.00 7.45 260750
13.61 Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade:
13.61.1 Two or more coats on new work
2.58 Providing and fixing of Tuflex Garden fencing Hexagonal net/or
equivalent of green colour having contents ( Weight grams/sqm.
510 (+/- 8%)) in width of 60 cm. with bamboo of 90 cm.
length. The bamboo should be painted with green colour paint of
approved brand and manufacture (two or more coats) and fixed
30 cm. below ground level and 60 cm. above ground level at a sqm 5652.00 199.45 1127291.4
distance of 1.50 mtrs. The net and bamboo should be binded
with 2 mm. G.I. Wire at three places properly as per direction of
Engineer-in-charge.
2.29 Providing Circular Cement Concrete pots of specified size, cast
with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse
sand: 4 graded stone aggregate 6 mm nominal size), reinforced
with 7 Nos ( 3 nos horizontal & 4 nos vertical “ U “ shape) M.S.
wires of 3.5 mm dia as per design, including required form
work, finishing with cement punning on exposed surface, curing
for specified period and stacking in required rows & height, all
complete as per direction of Officer-in-charge.
2.29.1 Top inside dia 35 cm, outer bottom dia 25 cm, total height 35
cm with wall thickness of 25.4 mm
2.29.2 Top inside dia 30 cm, outer bottom dia 20 cm, total height 30
cm with wall thickness of 25.4 mm
2.31 Filling of the following size empty pots with mixture of good
earth & manure in the ratio of 2:1 (Two part of Good earth &
one port of manure) and placing them on approprite place i/c
carriage of earth, manure and pots up to 50 mtr, as per
direction of officer incharge. (The cost of good earth, earthen
pots & manure will be paid seperately.)
2.31.6 Size of Empty Pots 25cm Top dia, 15cm Bottom Dia & 25cm
Perpendicular height.
2.31.7 Size of Empty Pots 35cm Top dia, 25cm Bottom Dia & 35cm
Perpendicular height.
2.40 Complete maintenance of the entire garden features having as
per yard stick in the garden area i.e. lawn trees, shrubs, herbs,
edge, flower beds, foliages, creepers etc. including
oeing,weeding, pruning, replacement of plants, gap filling,
watering, mowing of lawn, grass cutting by lawn mover
and brush cutter, removal of garden waste, applying insecticide,
pesticide & fertilizers(whenever required) top dressing of lawn
with good earth and manure and maintenance of other garden
related works as directed by office-in-charge (Cost of Good
Earth, Manure, Fertilizer, Insecticide, Pesticide will be provided
by the Department & lawn mover and brush cutter with fuel and
other T & P material/articles shall be provided by the
contractor.) and as per direction of officer in charge.
2.40.2 Permanent office accommodation.(1Mali for 1.25Acre) for 24 Per
months ater completion of work Sqm/
2.42 Complete maintenance of trees, jobs like making of basin at
regular interval,application of fertilizer etc, (excluding the cost
of material which shall be supplied by the department and other
T & P material/articles shall be provided by the contractor) as
per direction of officer in charge
2.42.1 Trees for 250 no/(up to 4 & up to 3 year Slow & Fast Per Plant/ Per
growing group) plant/
2.57 Plantation of Trees, Shrubs, and Hedge at site i/c watering and
removal of unsaverieable material’s as per direction of officer in
charge (excluding cost of plant & water)
2.57.1 Trees Plant
2.57.2 Shrubs Plant
2.57.3 Hedge Plant /Ground cover
3.36 Providing and displaying of Croton Petra Bangalore variety
having ht 45 cm & above, well developed with fresh and healthy
leaves in 20 cm size of Earthen pot/Plastic pot. & as per
direction of the officer-in-charge.
3.78 Providing and displaying of Rhapis palm specimen plant, having
ht. 1.50 m to 1.65 m with 40 to 50 lush green suckers, well
developed, fresh & healthy foliage leaves in 40 cm size of each 75 530.95 39821.25
Earthen Pot/Chali/Tray & as per direction of the officer-in-
5.11 Providing and Displaying Bismarckia Palm 115 to 180 cm ht.,
well developed 12 and above good color fresh and healthy
leaves in 40 cm Cement Pot as per direction of the officer-in-
5.12 Providing and Displaying Bougainvillea named variety, Sobhra,
Thima, Marry palmar, Cherry Blossom etc. well developed with
fresh & healthy bushy plant in full bloom 75 to 90 cm ht. in 40 Nos. 400 322.9 129160
cm Cement Pot as per direction of the officer-in-charge.
5.43 Providing and Displaying Travelers palm well developed with
fresh & healthy leaves foliage 210 to 240 cm ht specimen plant
in 40 cm Cement Pot as per direction of the officer-in-charge.
5.44 Providing and Displaying Washingtonia filifera palm well
developed 90 to 105 cm ht. having 5 to 6 straight fresh and
healthy leaves in 35 cm Cement Pot as per direction of the
officer-in-charge.
6.12 Providing and stacking of Duranta Golden, having ht.15 to 20
cm bushty shape with fresh and healthy leaves in 15 cm size of
Earthen Pot / Plastic Pot & as per direction of the officer-
6.17 Providing and stacking of Iresine herbstii, of height 20-30 cm.,
full of branches well developed in 15 cm size of Earthen Pot /
Plastic Pot & as per direction of the officer-in-charge..
6.29 Providing and stacking of Tradescantia, full of leaves in Earthen
Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-
6.31 Providing and stacking of Wedelia trilobata, full of leaves in 15
cm size of Poly bags & as per direction of the officer-in-charge.
6.7 Providing and stacking of Clerodendrum inerme having ht. 25
cm to 30 cm multi branched in 15 cm size of Earthen Pot /
Plastic Pot & as per direction of the officer-in-charge.
7.1 Providing and stacking of Acacia auriculiformis of ht 150-165 cm
in bag size of 25 cm as per direction of the officer-in-charge.
7.5 Providing and stacking of Azadirachta indica ( Neem ) of height
120-130cm in big polybag of size 25 cm as per direction of the
officer-in-charge.
7.7 Providing and stacking of Bauhinia blakeana (Kachnar) of height
120-150 cm. in big poly bags of size 25 cm as per direction of
the officer-in-charge
7.9 Providing and stacking of Bombax ceiba of height 150-165 cm.
in big poly bags of size 25 cm as per direction of the officer-in-
7.14 Providing and stacking of Callistemon lanceolatus of height 150-
165 cm. in big poly bags of size 25 cm as per direction of the
officer-in-charge.
7.16 Providing and stacking of Cassia fistula (Amaltash) of height
120-135 cm. in big poly bags of size 25 cm as per direction of
the officer-in-charge.
7.21 Providing and stacking of Chorisia speciosa of height 150-165
cm. in big poly bags of size 25 cm as per direction of the officer-
7.24 Providing and stacking of Delonix regia (Gulmohar) of height
150-165 cm. in big poly bags of size 25 cm as per direction of
the officer-in-charge.v
7.27 Providing and stacking of Ficus benjamina (green) of height 150-
165 cm., bushy with healthy branches and lush green foliage in
big size HDPE bags as per direction of the officer-incharge.
7.53 Providing and stacking of Mangifera indica (Mango-grafted ) of
height 60-75 cm. in big poly bag of size 25 cm as per direction
of the officer-in-charge.
7.59 Providing and stacking of Mimusops elengi (Maulsri) of height
180-195 cm., well developed with thick stem in big in big size
HDPE bag as per direction of the officer-in-charge.
7.60 Providing and stacking of Nauclea cadamba (Kadam) of height
150-165 cm. in big poly bag of size 25 cm as per direction of
the officer-in-charge.v
7.62 Providing and stacking of Peltophorum species of height 150-
165 cm. in big poly bags of size 25 cm as per direction of the
officer-in-charge.
7.71 Providing and stacking of Plumeria alba dwarf dwarf of height 90-
105 cm. with 3-4 branches and thick stem in big size HDPE bags
as per direction of the officer-in-charge.
7.72 Providing and stacking of Plumeria rubra of height 120-150 cm.
with 3-4 branches and thick stem in big size HDPE bags as per
direction of the officer-in-charge.
7.75 Providing and stacking of Polyalthia longifolia (Ashok) of height
180-195 cm. in gunny bag of size 30 cm as per direction of the
officer-in-charge.
7.79 Providing and stacking of Putranjiva roxburghii of height 90-105
cm. in big polybag of size 25 cm as per direction of the officer-in-
8.28 Providing and stacking of Ficus panda of height 90-105 cm. with
10-12 branches and healthy foliage, well formed in cement pots
of size 30 cm as per direction of the officer-in-charge.
8.33 Providing and stacking of Hamelia patens of height 90-105 cm.
bushy in big size HDPE bags as per direction of the officer-in-
8.46 Providing and stacking of Murraya exotica of height 45-60 cm. in
poly bags of size 15 cm as per direction of the officer-in-charge.
8.51 Providing and stacking of Nerium oleander (kaner) dwarf of
height 30-40 cm. in earthen pot of size 20 cm as per direction of
the officer-in-charge.
8.54 Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of
ht. 90-105 cm in Earthen pots of size 20 cm as per direction of
the officer-in-charge.
8.63 Providing and stacking of Tabernaemontana coronaria (Chandni
single) variegated of height 105-120 cm., multibranched, bushy
in big size HDPE bag as per direction of the officer-incharge.
2.1 Grassing with selection No. 1/ Doob grass including watering
and maintenance of the lawn for 30 days or more till the grass
forms a thick lawn, free from weeds and fit for mowing including
supplying good earth, if needed (the grass and good earth shall
be paid for separately)
2.10.1 In rows 5 cm apart in both directions
2.35 Supplying & Stacking of Selection No.1/doob grass at site fresh
& free from weeds having proper roots in green including per
loading, unloading, carriage and all taxes paid etc.and as per sqm
direction of officer in charge
7.4 Providing and stacking of Alstonia scholaris of height 150-165
cm. in bag of size 25 cm as per direction of the officer-in-
7.74 Providing and stacking of Polyalthia longifolia (Ashok) of height
150-165 cm. in earthen pots of size 25 cm as per direction of
the officer-in-charge.
5.41 Providing and Displaying Topiary of Casuarina fresh & healthy
having 5 to 6 specific shape and size ball well developed 195 to
210 cm ht. in 40 cm Cement Pot as per direction of the officer-in-
5.33 Providing and Displaying Golden Bottle brush Topiary well
developed with fresh & healthy foliage 5 to 6 big ball 115 to 180
cm ht in 40 cm Cement Pot as per direction of the officer-in-
8.76 Providing and stacking of Thuja compacta of height 75-90 cm.,
conical shaped, well formed with healthy foliage in earthen pots
of size 30 cm as per direction of the officer-in-charge.
4.88 Providing and stacking of plant Mogra of height 25 to 30 cm., 2
to 3 branch in earthen pots of size 20 cm Earthen Pot/Plastic Pot
and as per direction of the officer-in-charge.
8.7 Providing and stacking of Calliandra hybrida of height 105-120
cm., well branched, bushy in big size HDPE bag as per direction
of the officer-in-charge
8.4 Providing and stacking of Caesalpinia pulcherrima species of
height 45-60 cm. in earthen pot of size 20 cm as per direction of
the officer-in-charge.
5.3 Providing and Displaying Foxtail palm well developed with fresh
& healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot
as per direction of the officer-in-charge
7.41 Providing and stacking of Fishtail palm of ht. 270-300 cm
bottom girth 40- 50 cm well developed in big size HDPE bags as
per direction of the officer-in-charge.
3.22 Providing and displaying of Areca Palm having ht. 2.40 m to
2.70 m with 12 to 14 suckers, well developed, fresh and healthy
with lush green foliage in 35 cm size of Bucket type cement pots
& as per direction of the officer-in-charge
5.1 Providing and Displaying Acalypha Different colour well
developed, fresh & healthy with good foliage, multi branch 30 to
45 cm ht. in 20 cm size of Earthen Pot/ Plastic Pot bushy as per
direction of the officer-in-charge.
9.14 Providing and stacking of Vernonia elaegnifolia (curtain creeper)
plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots /
Plastic pots & as per direction of the officer-in-charge.
9.1 Providing and stacking of Passiflora caerulea (Rakhi bel) of
height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic
pots & as per direction of the officer-in-charge
9.7 Providing and stacking of Ipomoea purpurea (Morning glory) of
height30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic
pots & as per direction of the officer-in-charge.
Total DSR Horticulture and Landscaping-2018 147,54,555.20
“Comprehensive External Development, horticulture, landscaping and other miscellaneous works for
College of Veterinary and Animal sciences and College of Fisheries under Pkg-3 for RLBCAU, Datia, MP “
F Manual Irrigation Works
MR Description Units Qty RATE Amount
Pipes Work: Supply, laying & commissioning in position PVC pipe conforming to
IS:4985:2000 and suitable for the respective working pressures without all fittings and
1.00 accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail
pieces etc. jointing as per manufacturer's instruction
1.07 PVC fittings LS 469264.00
1.08 Earth work excavation and refilling 300x450mm Rm 8404 97.00 815183.15
2.00 DRIP & ACCESSORIES
Supply,Fixing & commissioning of flexible,kink resistant 16mm inline tubing with
pressure compensating, self flushing emitter and resistance to UV damage, algae
2.01 growth brown in colour with flow rate 2.3lph to 3.5 lph, pressure rating 0.58 to 4.1
bar wall thickness 1.2mm XFD with fittings.
Supply,Fixing & commissioning of flexible,kink resistant 16mm subsurface inline
tubing and copper shield technology protects the root intrusion and self flushing
2.04 emitter, brown in colour, UV damage and algae growth with flow rate of 3.4 lph
pressure rating 0.58 to 4.14 bar - WITH EARTH WORK - XFSDI with fittings.
Supply,Fixing & commissioning of Sub surface drip system operation Indicator,
2.05 Includes 16” of ¼” distribution tubing with connection fitting pre-installed
Supply,Fixing & commissioning of 2" Large Capacity Y Filters for submain filteration
2.06 ,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8
bar),Maximum Temperature Up to 140ºF (60ºC). Nos 17 3841.00 65297.00
Supply,Fixing & commissioning of 63mm/50mm/40mm dia self-closing flushing
Supply,Fixing & commissioning of 12- Gauge Galvanized Steal Rod Comes Pre -Bent
2.08 to Staple Distribution Tubing , XF Drip Line or XBS Tubing to Finished Grade.
Notched Sides. Corrosion -Resistant of TIE DOWN STAKE Nos 1900 28.00 53200.00
Supply,Fixing & commissioning of Gromatetake off Connects XF Series Drip Line
2.09 and Blank Tubing to PVC Mainlines at Low Pressures. 17mm GTO
Supply,Fixing & commissioning of 17mm End cap S Type for dripline closure at the
2.10 end of the dripline
3.00 SPRINKLERS & ACCESSORIES
Supply,Fixing & commissioning of Pop up spray head1804 Series Spray bodies, with Nos
Rotary nozzle having mutilple stream MPR spray having Co-moulded wiper seal.
3.01 Nozzle capable of covering 4.0-7.3m at 1.4 - 3.8 Bars pressure.
Supply,Fixing & commissioning of 5004 Series Rotor pop up sprinkler full/part circle
having radius of 6.7m - 12m @ 2.5 - 4.5 bar with discharge of 0.09 - 0.61 ltr./sec. The
sprinkler is gear driven rotary type with having 3/4" bottom inlet.
Supply,Fixing & commissioning of 1/2" Pop up Connecting Swing joint Assembly
having wall thickness of 2.3mm ,a working pressure of 5.5 kg/cm² at 43⁰C and a
surge pressure of 16.6 kg/cm². The fittings shall be made of UV resistant thermo
Supply,Fixing & commissioning of 3/4" Pop up Connecting Swing joint Assembly
having wall thickness of 2.3mm ,a working pressure of 5.5 kg/cm² at 43⁰C and a
3.29 surge pressure of 16.6 kg/cm². Flex pipe textured for wet conditions.The fittings shall
be made of UV resistant thermo plastic.
Supply,Fixing & commissioning of Imported HDPE service saddle of varying size
upto 63mm dia with pressure rating of PN 10 Nos 505 212.00 107060.00
4.00 VALVES & ACCESSORIES
Supply,Fixing & commissioning of PVC Ball Valve of size 63mm with pressure rating
Supply,Fixing & commissioning of PVC Ball Valve of size 50mm with pressure rating
Supply,Fixing & commissioning of PVC Ball Valve of size 40mm with pressure rating
Supply,Fixing & commissioning of a double acting air and vaccum release 1/2 " or
3/4" Air release valve. The working pressure shall be 5 bar. Nos 17 828.00 14076.00
Supply of a double acting air and vaccum release 2 " Air release valve .The working
pressure shall be 10 KSC . 10 1589.00 15890.00
Supply, Fixing & commissioning of 6"Round box with greenlid and corrugated
structure with unique shovel access slot and bolt hole knockout & Having
Dimensions @ Top Opening :6 1/8" Dia & Bottom Opening 8 5/8" Dia.
Supply, Fixing & commissioning of 10" Round Valve Box with greenlid and
corrugated structure with unique shovel access slot and bolt hole knockout & Having
Dimensions @ Top Opening 10" Dia & Bottom Opening 12 13/16" Dia.
Supply, Fixing & commissioning of 12" Rectangular Standard Valve Box with
greenlid and corrugated structure with unique shovel access slot and bolt hole
knockout & having Dimensions @ Top Opening:18 1/4" L X 13" W & bottom opening
Supply, Fixing & commissioning of 18'' Jumbo Rectangular Standard Valve Box with
greenlid and corrugated structure with unique shovel access slot and bolt hole
knockout & having Dimensions @ Top Opening:18 1/4" L X 13" W & bottom opening
Supply, Fixing & commissioning of 3/4th Quick coupling valve made up of solid
4.10 brass with locking cover corrosion resistant and stainless steel spring,
Supply, Fixing & commissioning of 3/4th Key threads into top of QCV to provide
water access. Nos 9 4768.00 42912.00
Supply, Fixing & commissioning of 3/4th Hose Swivel Made up of Solid Brass
Swivels up to 360 degrees to allows hose to be pulled in any direction & Also to
prevent Hose Damage.
5.00 FILTRATION UNIT Nos
5.01 Supply,Fixing & commissioning of 2.5" Disc Filter with capacity 50m3/Hr . Nos 4 14348.00 57392.00
6.00 PUMPING UNIT
Supply, Fixing & commissioning of Monobloc or openwell submersible pumpset of
having discharge and head of design flow with pressure gauge, UPVC sch 80 -
suction & delivery manifold and mounted on a
6.01 baseframe with proper supports. .
Duty of Pump : 3.00 LPS Each Pump
Pressure Head Range = 55 Mtr
No. of Pumps : 1 Working + 0 Standby Set 4 72,621 290484.00
Supply, Fixing & commissioning of control panel suitable for pumpset having panel
box made of CRCA sheet of 2 mm thickness and fixed along with following
6.02 accessories DOL starter,start / stop push buttons, Ammeter, Single phase preventer
, Voltmeter , Indicating lamps ), MCB Dry level guard sensor with control cable, etc.
Supply, Fixing & commissioning of 2" control Valve, Butterfly Valve in mainline for
6.03 bypass and flow diversion of approved quality with pressure rating of PN 10
Supply, Fixing & commissioning of 2" Non Return Valve to prevent back flow have
6.04 flap type or spring type with pressure rating of PN 10
Supply, Fixing & commissioning of 2" Pressure release valve with pressure setting
6.05 from 0 to 7 Bar.
7.00 Automation Equipments
Supply, Fixing & Commissioning of Direct burial 14 Awg x 2 Maxi cable with PVC
insulated UL standard 493 with impregnated polyethylene jacket and soft annealed
7.01 tin coated copper confirming to ASTM B-33 for two way communication between
decoder controller and decoders complete with suitable conduit pipe
Supply, Fixing & commissioning of ESPLXD Station Modular Controller UV
resistant basic 8 station and expandable upto 48stations,wall mount case, with LCD
display ,non volatile memory for 100years,10KV surge protection with removable
front panel and programmable under battery in office, and flow watch options to
shutdown system if any damage or excess flow or dry run
shutdown,cycle+soak,raindelay,station delay ,alarm light ,electronic diagnostic circuit
breaker ,program summary and review, wiring test,,4programm and 8start time per
program with adjustable delay between stations, slow closing valve, removable
battery, and sensor terminals ESPseries
Supply , Fixing & Commissioning of ESP-LXD Control ESP LXDSM75 Module for
adding the stations Nos 1 44147.00 44147.00
Supply, Fixing & Commissioning of Field Decoder support 1 station ,fully water proof
encapsulation, power draw 0.5mA at idle and 18mA at active ,working range 0 deg
7.04 to 50 degree centigrade as per specifications and with different station capacities as
given below Field Decoder 1 station
Supply, Fixing & commissioning of 2" Solenoid globe Valves with fabric reinforced
diaphragm and rugged PVC durable glass -filled nylon construction ,compatible with
and slow closing to prevent water hammer, pressure rating upto 10.4 KSC and
7.05 maximum flow of 150GPM ,max water temp. upto 42degree centigrade, with 24AC
solenoid, current rating 0.41A @60Hz,coil resistance 30ohm with provision to
attach PRS-Dial PGA
Supply, Fixing & commissioning of 1.5" Solenoid globe Valves with fabric reinforced
diaphragm and rugged PVC durable glass -filled nylon construction ,compatible with
and slow closing to prevent water hammer, pressure rating upto 10.4 KSC and
7.06 maximum flow of 150GPM ,max water temp. upto 42degree centigrade, with 24AC
solenoid, current rating 0.41A @60Hz,coil resistance 30ohm with provision to
attach PRS-Dial PGA
Supply, Fixing & commissioning of 1" Solenoid globe Valves with fabric reinforced
diaphragm and rugged PVC durable glass -filled nylon construction ,compatible with
and slow closing to prevent water hammer, pressure rating upto 10.4 KSC and
maximum flow of 150GPM ,max water temp. upto 42degree centigrade, with 24AC
solenoid, current rating 0.41A @60Hz,coil resistance 30ohm with provision to
attach PRS-Dial PGA Nos 1 5960.00 5960.00
Supply, Fixing & commissioning of 3" Solenoid globe Valves as central shut off
valve with fabric reinforced diaphragm and rugged PVC construction ,compatible
and slow closing to prevent water hammer, pressure rating upto 0,7 to 10 KSC and
7.08 maximum flow of 10 to 100 m3/h ,max water temp. upto 60°C with 24 VAC - 50 Hz,
coil resistance 30ohm with provision to attach PRS-Dial
Supply, Fixing & commissioning of PRS-DIAL to Maintain constant outlet pressure
Supply, Fixing & commissioning of Line Surge Protection device as required with
7.10 copper grounding rod, clamps, charcoal and all requisite accessories complete LSP
Supply, Fixing & commissioning of direct bury -on wire connector with strain relief
7.11 ,UL486 D certified ,with waterproof silicon sealant ,fits wire from 22ga to 6 ga as per
specifications complete DBRY Nos 306 232.00 70992.00
Supply, Fixing & commissioning of automatic rain shut off device ,latching hinge with
7.13 multiple rainfall settings 5mm to 20mm UL CUL listed and CE approved complete
Supply, Fixing & commissioning of Pump relay 24 AC PLA relay ,stabilizer 300watts
“Comprehensive External Development, horticulture, landscaping and other miscellaneous works for College of
Veterinary and Animal sciences and College of Fisheries under Pkg-3 for RLBCAU, Datia, MP “
SUMMARY OF COST EXTERNAL ELECTRICAL WORKS
S.NO NAME OF SUB-HEAD
CPWD DSR 2018 items Non Scheduled items
1 SUB HEAD-1: W I R I N G & SUBMAIN 3,85,181
2 SUB HEAD -II : DISTRIBUTION BOARD 74,016
SUB HEAD - III : LIGHTING FIXTURE &
4 SUB HEAD - IV :EARTHING WORK 15,46,612
SUB HEAD - V :MV/HV CABLE LAYING &
END TERMINATION WORK
6 SUB HEAD - VI :CIVIL WORK 17,08,000
7 SUB HEAD -VII :TWO POLE STRUCTURE 3,17,304
8 SUB HEAD - VIII :33KV HT PANEL 53,00,069
9 SUB HEAD -IX :TRANSFORMER WORK 111,70,899
10 SUB HEAD - X :DG SET WORK 266,49,208
SUB HEAD - XI :LT PANEL &
DISTRIBUTION PANEL WORK
SUB HEAD - XII :EXTERNAL LIGHTING
SUB HEAD - XIII :SUPPLY OF HT & MV
BOQ- Ext. Dev., Datia, MP
SUB HEAD - XIV:SAFETY EQUIPMENT
Sub-Head - XV- EXTERNAL VIDEO
SURVEILLANCE SYSTEM (IP CCTV)
Sub-Head - XVI- COMPREHENSIVE Annual
maintenance of HVAC system
Sub-Head - XVI- COMPREHENSIVE Annual
Maintenance of LV, IT, BMS system etc.
SUB HEAD-XVII : 200 KW GRID TIE SOLAR
Total Amount of Schedule & Non
Total Amount of Schedule & Non
BOQ- Ext. Dev., Datia, MP
“Comprehensive External Development, horticulture, landscaping and other miscellaneous works for College of Veterinary and Animal
sciences and College of Fisheries under Pkg-3 for RLBCAU, Datia, MP “
BILL OF QUNATITIES FOR ELECTRICAL WORKS (EXTERNAL ELECTRICAL)
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
1 SUB HEAD-1: W I R I N G & SUBMAIN
Wiring for light point/ fan point/ exhaust fan point/ call bell point with
1.5 sq.mm FRLS PVC insulated copper conductor single core cable in
1 1.1 surface / recessed medium class PVC conduit, with modular switch,
modular plate, suitable GI box and earthing the point with 1.5 sq.mm
FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group cpntrolled looped light point/ fan point/ exhaust fan
point/ call bell point ( without independent ) with 1.5 sq.mm FRLS PVC
2 1.55 insulated copper conductor single core cable in surface / recessed
medium class PVC conduit, and earthing the point with 1.5 sq.mm
FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated
copper conductor single core cable in surface/ recessed medium class
3 1.12 PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper Metre 300 200 60,000
conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated
copper conductor single core cable in surface/ recessed medium class
4 1.13 PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper Metre 100 308 30,800
conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FRLS PVC insulated copper conductor, single core
cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Circuit Wiring & Light Metre 50,100
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
2 X 6 sq. mm + 1 X 6 sq. mm earth wire (For Single Phase DB. From Metre 12,450
Sub Panel to DB)
4 X 6 sq. mm + 2 X 6 sq. mm earth wire (For Three Phase DB. From Metre 19,700
Sub Panel to DB)
4 X 10 sq. mm + 2 X 10 sq. mm earth wire (For Three Phase DB. From Metre 81,450
Sub Panel to DB)
Supplying and fixing two module stepped type electronic fan regulator
6 1.25 on the existing modular plate switch box including connections but 15 342
excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing
modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate Each 6,015
and cover in front on surface or in recess, including providing and fixing
3 pin 5/6 A modular socket outlet and 5/6 A modular switch,
connections etc. as required.
Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess, including providing and fixing
6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular
switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction
box/ wooden block including connections etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring
the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS
11 1.45 PVC insulated, copper conductor, single core cable, including providing 15 203 3,045
and fixing phenolic laminated sheet cover on the fan box etc. as
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Installation of exhaust fan in the existing opening, including making
good the damage, connection, testing, commissioning etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a exhaust Each 1,008
fan of all sizes.
Total of Sub-Head - I carried to summary sheet 3,85,181 0
14 2 SUB HEAD -II : DISTRIBUTION BOARD
Supplying and fixing following way, single pole and neutral, sheet steel,
MCB distribution board, 240 V, on surface/ recess, complete with
15 2.3 tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required.
(But without MCB/RCCB/Isolator)
15.1 2.3.2 8 way, Double door Each 3 1,760 5,280
Supplying and fixing following way, horizontal type three pole and
neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess,
16 2.4 complete with tinned copper bus bar, neutral bus bar, earth bar, din
bar, interconnections, powder painted including earthing etc. as
required. (But without MCB/RCCB/ Isolator).
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve,
miniature circuit breaker suitable for inductive load of following poles in
the existing MCB DB complete with connections, testing and
commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB Each
complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the
18 2.12 existing MCB DB complete with connections, testing and commissioning
etc. as required.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supplying and fixing following rating, four pole, 415 V, isolator in the
19 2.13 existing MCB DB complete with connections, testing and commissioning
etc. as required.
Supplying and fixing following rating, double pole, (single phase and
neutral), 240 V, residual current circuit breaker (RCCB), having a
sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along
21 2.17 with 16/25/32 A, 415 V “C” curve TP MCB complete with connections, 2 1,146 2,292
testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, Each
with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C”
22 2.18 curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with 2 1,232 2,464
chained metal cover for the socket out let and complete with
connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, Each
made of mild steel, at least 2 mm thick, and vitreous enameled white
on both sides, and with inscription in single red colour on front side as
Total of Sub-Head - II carried to summary sheet 74,016 0
24 SUB HEAD - III : LIGHTING FIXTURE & FAN
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Installation, testing and commissioning of pre-wired, fluorescent fitting
/ compact fluorescent fitting of all types, complete with all accessories
24.1 1.41 and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. 90 168 15,120
mm FRLS PVC insulated, copper conductor, single core cable and
earthing etc. as required.
25 NS-1 Supply of Light fixture as given below
Supply, Installation, Testing and Commissioning of 15W(Nominal) Each
Surface Mounted LED square Downlighter.
Supply, Installation, Testing and Commissioning of 20W(Nominal) Each
Wall/Surface mouted 4 ft. LED.
Supply, Installation, Testing and Commissioning of 10 W Bulk head Each
25.4 1.4 Supply of 10W Mirror Light. Each 5 828 4,140
Supply of 1200 mm sweep 3 blade energy saving Ceiling fan complete Each
25.5 1.5 with assembling of blades, down rod, shackle insulator, canopy etc. 20 2,192 43,840
Supplying of Plastic Body Ornamental Exhaust Fan Light duty 230V Each
A.C 50 cycles, 300 mm sweep, 1300 rpm, energy efficient,
25.6 1.6 complete erected in position with all accessories. Make- Havels- Venti 6 2,414 14,484
Air DS, or Equivalent to Orient- Ventilator DS, Cromptong & Greaves-
Ventilus 250 or equivalent as per specification.
25.7 1.7 Supply of 70W LED floolight luminaire for building highlighter. Each 6 8,967 53,802
Total of Sub-Head - III carried to summary sheet 15,120 1,91,476
26 Sub-Head - IV- EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including
accessories, and providing masonry enclosure with cover plate having
locking arrangement and watering pipe etc. with charcoal/ coke and
salt as required.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick
including accessories, and providing masonry enclosure with cover
plate having locking arrangement and watering pipe of 2.7 metre long
etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick
including accessories, and providing masonry enclosure with cover
plate having locking arrangement and watering pipe of 2.7 metre long
etc. (but without charcoal/ coke and salt ) as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level
26.4 5.7 for conductor earth electrode, including connection/ termination with Metre 2000 44 88,000
GI thimble etc. as required.(For Pole earthing).
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I.
26.5 5.10 pipe from earth electrode including connection with brass nut, bolt, Metre 600 1,224 7,34,400
spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe
26.6 5.11 from earth electrode including connection with G.I. nut, bolt, spring, Metre 400 483 1,93,200
washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG
26.7 5.12 dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including Metre 100 188 18,800
connection with G.I. thimble excavation and re-filling as required.
Total of Sub-Head - IV carried to summary sheet 15,46,612 0
Sub-Head - V - MV/HV CABLE LAYING & END TERMINATION
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Laying of one number PVC insulated and PVC sheathed / XLPE power
cable of 1.1 KV grade of following size direct in ground including
excavation, sand cushioning, protective covering and refilling the
trench etc as required.
27.2 7.1.2 Above 35 sq. mm and upto 95 sq. mm Metre 523 338 1,76,774
27.3 7.1.3 Above 95 sq. mm and upto 185 sq. mm Metre 280 352 98,560
27.4 7.1.4 Above 185 sq. mm and upto 400 sq. mm Metre 1558 396 6,16,968
Laying of one number additional PVC insulated and PVC sheathed /
XLPE power cable of 1.1 KV grade of following size direct in ground in
28 7.2 the same trench in one tier horizontal
formation including excavation, sand cushioning, protective
covering and refilling the trench etc as required.
28.2 7.2.2 Above 35 sq. mm and upto 95 sq. mm Metre 522.5 236 1,23,310
28.3 7.2.3 Above 95 sq. mm and upto 185 sq. mm Metre 280 251 70,280
28.4 7.2.4 Above 185 sq. mm and upto 400 sq. mm Metre 3117 294 9,16,398
Laying of one number PVC insulated and PVC sheathed / XLPE power
29 7.6 cable of 1.1 KV grade of following size in the existing masonry open
duct as required.
29.1 7.6.2 Above 35 sq. mm and upto 95 sq. mm Metre 20 38 760
29.2 7.6.3 Above 95 sq. mm and upto 185 sq. mm Metre 40 52 2,080
29.3 7.6.4 Above 185 sq. mm and upto 400 sq. mm Metre 800 96 76,800
30 8 H V CABLE LAYING
Laying of one number additional XLPE power cable of 33 KV
grade of following size direct in ground in the same trench in
31 8.6 one tier horizontal formation including excavation, sand cushioning,
protective covering and refilling the trench etc as
31.1 8.6.2 Above 120 sq. mm and upto 400 sq. mm Metre 2000 348 6,96,000
32 9 MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland
and aluminium lugs for following size of PVC insulated and PVC
sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
33 10 HV CABLE JOINTING & END TERMINATION
Supplying and making indoor cable end termination with heat
shrinkable jointing kit complete with all accessories including
lugs suitable for following size of 3 core, XLPE aluminium conductor
cable of 33 KV grade as required :
Supplying and making outdoor cable end termination with heat
shrinkable jointing kit complete with all accessories including lugs
suitable for following size of 3 core, XLPE aluminium conductor cable of
33 KV grade as required :
Total of Sub-Head - V carried to summary sheet 42,86,052 71,400
35 14 Sub-Head - VI - CIVIL WORK
Providing, laying and fixing following dia RCC pipe NP2 class (light
duty) in ground complete with RCC collars, jointing with cement mortar
1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and
refilling etc as required.
Total of Sub-Head - VI carried to summary sheet 17,08,000 0
36 NS-3 Sub-Head - VII - TWO POLE STRUCTURE:
Supply, erection and commissioning of 2 pole structure for terminating
33 KV O.H. supply from State Electricity Boards as per specifications.
The 2-pole structure shall comprise of:
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
MS tubular swaged pole 11 mtrs high (410 SP 24 as per latest IS), in
cement concrete foundation 1:3:6 (1 cement : 3 coarse sand : 6
graded aggregate 40mm nominal size) including excavation and
refilling etc. as required. The rate shall be inclusive of painting with 2
coats of aluminium paint (on red oxide). The portion of pole under the
ground shall be provided with 2 coats of bituminous paint.2 Nos.
Steel sections, channels angles, flats, clamps, GI nuts, bolts and
required hardware etc of different sizes for cross arms, bracings,
supports etc. for pole GOD etc. including anticlimbing barbed wires
(conforming to latest IS) having 4 points barbs spaced 75 ±12mm
apart. All steel structure shall be given 2 coats of red oxide primer and
2 finishing coats of aluminium paint as required as per drawings and
direction of Engineer-in-Charge. Lot-1
Supply,installation, testing and commissioning of 33 KV class
disc/pin/support insulators complete with clamps and fixing hard wares
etc. complete as required as per drawings and direction of Engineer-in-
Supply,installation, testing and commissioning of 33 KV station class
thyrite type lightning arrestors complete with mounting arrangement
(on all phases). 3 Nos.
Supply,installation, testing and commissioning of drop out - lock out
(DOLO) fuse, gang operating device (Air Break Switch) with pad locking
arrangement (operating rod to be supported properly), complete with
operating handle and locking arrangement. Set-1 Nos.
Supply,installation, testing and commissioning of GI stay set complete
with 20mm dia 1.8 M long stay rod with 450 x 450 x 7.5 mm anchor
plate with thimbles, stay clamps, 7/4.00 mm dia GI stay wire, turn
buckle (20mm x 600mm) strain insulator bow tightner in cement
concrete 1:3:6 foundation as excavation and refilling. Set-2 Nos.
Total of Sub-Head - VII carried to summary sheet Each 2 1,58,652 3,17,304
37 Sub-Head - VIII - 33KV HT PANEL
38 NS-4 33 KV HT PANEL :
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supply, delivery, erection, testing and commissioning of a HT panel
(Expandable Type), indoor duty, totally enclosed sheet steel clad,
floor mounting, vermin proof, fully interlocked vertical isolation,
extensible, horizontal draw out, air insulated, metal clad switchboard.
The switchboard would be complete with necessary PVC insulated
copper busbars, small wiring, labels, cable eyes, cable termination to
receive XLPE cables, foundation bolts and suitable for operation on 33
kV 3 phase, 50 cycle, earthed system. The panel shall be complete with
cable termination arrangement for incoming & outgoing XLPE, 33 kV
(E) cables. The panel shall comprise of the following:
a) Each Module shall be provided with inbuilt Earth Switch
b) Each Module shall have Front & Back Door Interlock
c) Panel shall be Floor Rolled trolley Design.
d) Short Circuit Rating shall be for 3 Seconds.
e) Panel shall be Scada Compatible.
f) Relays shall be Numeric Type.
g) Panel should be Internal Arc Typed Test for 31.5kA for 1 sec.
Panels shall be suitable for loss of service continuity LSC 2B. Safety
shutters complying with IEC-62271-200.
1.1 4 Panel Board (Indoor Type)- Expandable Type
Incoming (1 No.):
Each shall have the following:
33 kV, 31.5kA 3 Sec 1250A VCB with motorized spring charge closing
mechanism with inbuilt antipumping protection (without seperate
relay) and trip free features, Floor rolled VCB, internal arc type tested
design 31.5kA for 1 Sec. with inbuilt earth switch ,motor voltage 230V
AC and tripping/ closing coil voltage, 110 V DC and VCB complete with
4 NO + 4 NC auxiliary switch contact as spare complete with
i 230 V AC spring charge meter.
ii 110 V DC shunt trip coil.
Sets of three phase draw out type PT of ratio 33kV/√3 :110V/√3,
Class.0.5 per phase with control fuses.
Sets of 200-100/5-5A, class 0.5 accuracy, burden 7.5 VA current
transformer (cast resin) for metering, ISF<5 .
Sets of 200-100/5-5A, class 5P10 accuracy, burden 7.5 VA Current
Transformer for protection, ISF<5.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
vi. (0-500) digital Ammeter with selector switch and required CTs.
vii. (0-33kV) digital Voltmeter with selector switch and required CTs.
One (1) No. Multifunction meter with RS-485 Port suitable for
measurement of voltage, currents, power factor, frequency, Energy
(KWH, KVARH KVAH), Power (KW, KVA and KVAR), harmonics and
maximum demand indication
One (1) Set of Multifunctional protection relay with RS485
Communication Compatibility & protection. 50,51,50N,51N
x Mater Trip Relay - 86
xi U/V & O/V Relay - 27-59
xii Trip Circuit Supervison relay - 95
xiii Ground fault Relay - 63X
xiv Breaker control switch : (Trip-Neutral- Close)
xv Sets of phase & breaker ON/OFF indicating lamps.
xvi 5/15 A five pin socket +15A switch.
Sets of circuit breaker ON/OFF/Trip/ Spring charged/Trip circuit healthy
indicating lamps
xviii 100 W anticondensation space heater control by thermostat.
xix Mechanical ON/OFF/Trip indication.
33kV, 31.5kA 1250A rectangular electrolytic grade color coded and
sleeved Copper busbar. 31.5kA for 3 sec.
Outgoing : Three(3) Nos.
Each shall have the following:
33 kV, 31.5kA 3 Sec 1250A VCB with motorized spring charge closing
mechanism with inbuilt antipumping protection (without seperate
relay) and trip free features, Floor rolled VCB, internal arc type tested
design 31.5kA for 1 Sec. with inbuilt earth switch ,motor voltage 230V
AC and tripping/ closing coil voltage, 110 V DC and VCB complete with
4 NO + 4 NC auxiliary switch contact as spare complete with
i 230V AC spring charge meter.
ii 110 V DC shunt trip coil.
iii (0-500) digital Ammeter with selector switch and required CTs.
Sets of 100-50/5-5-1A, class 0.5 accuracy, 7.5 VA current transformer
(cast resin) for metering, ISF<5.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Sets of 100-50/5-5-1A, class 5P10 accuracy, 7.5 VA Current
Transformer for protection, ISF<5.
One (1) No. Multifunction meter with RS-485 Port suitable for
measurement of voltage, currents, power factor, frequency, Energy
(KWH, KVARH KVAH), Power (KW, KVA and KVAR), harmonics and
maximum demand indication.
One (1) Set of Multifunctional protection relay with RS485
Communication Compatibility & protection. 50,51,50N,51N.
viii Mater Trip Relay - 86
ix Trip Circuit Supervison relay - 95
x U/V & O/V Relay - 27-59
xi Sets of auxiliary relay-for WTI, OTI & Bucholtz Alarm & Trip - 63X
Breaker control switch : (Trip-Neutral- Close)
xii Set of phase and breaker ON/OFF indicating lamps.
xiii 5/15 A five pin socket +15A switch.
Sets of circuit breaker ON/OFF/Trip/ Spring charged/Trip circuit healthy
indicating lamps
xv 100 W anticondensation space heater control by thermostat.
xvi Mechanical ON/OFF/Trip indication.
Potential free contact to be provided for HT trouble in each breaker to
be used for annunciation in the control room.
The potential free contacts for transformer troubles annunciation &
trips for WTI should be provided for remote annunciation in the control
room. Required contactors / control relays with sufficient NO/NC
contacts shall be provided.
iii Each O/G feeder to be provided with 8 window annunciator.
All indication lamps shall be LED type and 110 Volt DC
iv All CT & PT shall be of cast resin type.
SITC of One (1) No. 7AH - (230VAC-110VDC) Power Pack of suitable
2 back-up rating for indications, annunciations and trip coil operations as
per specification and as required in each panel.
33 KV HT PANEL as described above. Set 1 38,16,410 38,16,410
39 4.2 Single Panel Board (Incoming cum Outgoing) For residential
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
33 kV, 31.5kA 3 Sec 630A VCB with motorized spring charge closing
mechanism with inbuilt antipumping protection (without seperate
relay) and trip free features, Floor rolled VCB, internal arc type tested
design 31.5kA for 1 Sec. with inbuilt earth switch ,motor voltage 230V
AC and tripping/ closing coil voltage, 110 V DC and VCB complete with
4 NO + 4 NC auxiliary switch contact as spare complete with
i 230 V AC spring charge meter.
ii 110 V DC shunt trip coil.
Sets of three phase draw out type PT of ratio 33kV/√3 :110V/√3,
Class.0.5 per phase with control fuses.
Sets of 100-50/5-5A, class 0.5 accuracy, burden 7.5 VA current
transformer (cast resin) for metering, ISF<5 .
Sets of 100-50/5-5A, class 5P10 accuracy, burden 7.5 VA Current
Transformer for protection, ISF<5.
vi. (0-500) digital Ammeter with selector switch and required CTs.
vii. (0-33kV) digital Voltmeter with selector switch and required CTs.
One (1) No. Multifunction meter with RS-485 Port suitable for
measurement of voltage, currents, power factor, frequency, Energy
(KWH, KVARH KVAH), Power (KW, KVA and KVAR), harmonics and
maximum demand indication
One (1) Set of Multifunctional protection relay with RS485
Communication Compatibility & protection. 50,51,50N,51N
x Mater Trip Relay - 86
xi U/V & O/V Relay - 27-59
xii Trip Circuit Supervison relay - 95
xiii Ground fault Relay - 63X
xiv Breaker control switch : (Trip-Neutral- Close)
xv Sets of phase & breaker ON/OFF indicating lamps.
xvi 5/15 A five pin socket +15A switch.
Sets of circuit breaker ON/OFF/Trip/ Spring charged/Trip circuit healthy
indicating lamps
xviii 100 W anticondensation space heater control by thermostat.
xix Mechanical ON/OFF/Trip indication.
SITC of One (1) No. 7AH - (230VAC-110VDC) Power Pack of suitable
2 back-up rating for indications, annunciations and trip coil operations as
per specification and as required in each panel.
33 KV SINGLE HT PANEL as described above. Set 1 10,42,192 10,42,192
40 4.3 HT Yard Works
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Formation of H.T Yard of size 18mts X 5 mts ground level raised from
the existing ground level for minimum height 300 mm provided with
necessary retaining wall , inside the yard filled with sand and top
provided with 150 mm layer of 40 mm & below stone aggregated in the
Supply and fixing MS rectangular pole made of 6 equal angles of
65X65X6 mm welded together/back to back and with 4 Nos 16 mm dia
MS rods equal of length including all materials, cutting , bending ,
welding, Al.painting etc complete and fixed in ground using CC 1:2:4
with all accessories for chain Link Fencing Lot 1 4,41,467 4,41,467
Providing G.I. chain link fencing 50mm size of 8 guage properly
stertched between rectangular poles and fixed wit suitable bolts and
nuts, the free end shall be welded to the pole and black pipe at top and
bottom as required including the cost of all materials and labour
Supply and erection of welded mesh fencing M.S gate for a height of
2400 mm and 1200 mm wide hinged with necessary AL. frame work
with painting the gate complete with accessories.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Total of Sub-Head - VIII carried to summary sheet 53,00,069
Sub-Head - IX - TRANSFORMER WORK
41 NS-5 33/0.433 KV, 1600 KVA Transformer (Plinth Mounted)
Supply, installation, testing and commissioning of 1600 kVA,
33000/433 volts Deta/Star, vector group Dyn11, outdoor mounting, oil
cooled, ONAN transformer with On Load Tap Changers, suitable for
incoming voltage variation of +5% to –15% in steps of 1.25% to give
a constant secondary voltage. The transformer shall be provided with
41.1 NS-5.1 fittings, accessories, protection, first filing of oil etc. including Buchholz Each 2 37,99,510 75,99,020
oil temperature alarm/trip protection in LV chamber complete as per
specifications and as required. The transformer shall be provided with
arrangement to terminate XLPE cable on HT side and to connect
Aluminium cable on LT side, complete as required.. The losses of the
Transformer should be as per latest IS 1180 Level 2 Losses.
Supply, installation, testing and commissioning of 315 kVA,
33000/433 volts Deta/Star, vector group Dyn11, outdoor mounting, oil
cooled, ONAN transformer with On Load Tap Changers, suitable for
incoming voltage variation of +5% to –15% in steps of 1.25% to give
a constant secondary voltage. The transformer shall be provided with
41.2 NS-5.2 fittings, accessories, protection, first filing of oil etc. including Buchholz Each 1 19,31,417 19,31,417
oil temperature alarm/trip protection in LV chamber complete as per
specifications and as required. The transformer shall be provided with
arrangement to terminate XLPE cable on HT side and to connect
Aluminium cable on LT side, complete as required.. The losses of the
Transformer should be as per latest IS 1180 Level 2 Losses.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supply, installation, testing and commissioning of 250 kVA,
33000/433 volts Deta/Star, vector group Dyn11, outdoor mounting, oil
cooled, ONAN transformer with On Load Tap Changers, suitable for
incoming voltage variation of +5% to –15% in steps of 1.25% to give
a constant secondary voltage. The transformer shall be provided with
fittings, accessories, protection, first filing of oil etc. including Buchholz
oil temperature alarm/trip protection in LV chamber complete as per
specifications and as required. The transformer shall be provided with
arrangement to terminate XLPE cable on HT side and to connect
Aluminium cable on LT side, complete as required.. The losses of the
Transformer should be as per latest IS 1180 Level 2 Losses. For
Total of Sub-Head - IX carried to summary sheet 0 111,70,899
42 NS-6 Sub-Head - X - DG SET WORK
Supplying, loading, installation, testing & commissioning of Diesel
Generating set having Prime Power Rating of 1010KVA, radiator cooled
type, with Acoustic Enclosure with Silent Type silencer, 415 Volts at
1500 RPM, 0.8 lagging power factor suitable for 50 Hz, 3 phase system
and as per latest CPCB-II, 990 Ltr inbuilt fuel tank. The DG Sets shall
be suitable for being overloaded upto 10% of the rated capacity for 1
hour in every 12 hours and consisting of the followings: The DG set
shall be suitable for above 0.85 loading factor with net output shall be
1010 kVA as per site conditions with Genset governing Class G3 as per
IS 8528. Silent Diesel Genset shall be provided with remote monitoring
system to monitor the genset operational parameters at
desktop/smartphones.
A. DIESEL ENGINE:
Diesel Engine 4 stroke water cooled, electric start, of suitable BHP at
1500 RPM suitable for above output of alternator at 40 Degree C, 50%
RH & at 1000 MSL and conforming to BS 5514, BS 649, IS 10000,
capable of taking 10% over loading for one hour after 12 hours of
continuous operation. The engine will be fitted complete with all the
required accessories.
Type: Radiator Cooled
Fuel injection :As per manufacturer
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Engine Starting : Battery starting.
Starting position : Universal. Auto/Manual
The Engines shall include:
• Flywheel with guard.
• Flexible connection.
• Bellow / expansion joints
• Electronic governor with electronic fuel injection system
• Fuel and lube oil filters and pumps
• Day Fuel tank with visual level indicators etc.
• Silencer as per latest amendments of MOEF/CPCB
• Safety controls
• Instrument panel
• Exhaust piping to let out the exhaust at mandatory height above the
canopy including support arrangement and insulation with cladding
inside the canopy etc.
Synchronous alternator rated at 1010 KVA, 415 volts at 1500 RPM, 3
phase 50 HZ, AC supply with 0.8 lagging power factor at 40 Degree C,
50% RH & at 1000 Meter MSL. The alternator shall be having SPDP
enclosure, brushless, continuous duty, self excited & self-regulated
through suitable AVR conforming to site condition and with Class-H
Type : Brushless.
Actual Power 1010 KVA at 40 deg C.
Frequency : 50 Cycles/sec.
Supply System: 3 phases & neutral
Connection : Star.
Rated rpm. : 1500 RPM
Casing protection : As per IP-23
Insulation : Class H.
Power Factor : 0.8.
Controller : The DG sets should be suitable for Auto ON/OFF or
equivalent including providing of Engine control panel.
C. ACCESSORIES:
The Diesel Engine shall be equipped with minimum following/ as
indicated in the specifications, devices/ accessories built-in type
including all standard fittings.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Fuel supply pump with manual venting pump.
Turbo charger with air filter (dry/oil bath type) and damper.
Charge air cooler.
Suction fuel filter
Lube oil filter.
Hour meter and RPM indicator.
Battery Starting Mechanism.
Instrument/Indication panel complete with the followings;
a) Starting Switch with key.
b) Lub. Oil Temp. gauge.
c) Lub. Oil Pressure Gauge.
d) Water Temp. gauge.
Control devices for safety and monitoring along with indicators.
Common base/foundation frame.
Anti vibration pads
24V DC Starting system comprising of starter motors: Voltage
regulator and arrangement for initial excitation complete with suitable
nos. of Maintenance free batteries as per manufacturer standards for
minimum 6 no. consecutive starts as required as per specifications.
The cost of initial charge of lubricants, coolant etc.
The DG sets shall include the cost of all accessories, fittings,
protections, instruments, safety controls, alarms, indications etc.
complete as per specifications, as required
Supplying, loading, installation, testing & commissioning of Diesel
Generating set having Prime Power Rating of 800 KVA, radiator cooled
type, with Acoustic Enclosure with Silent Type silencer, 415 Volts at
1500 RPM, 0.8 lagging power factor suitable for 50 Hz, 3 phase system
and as per latest CPCB-II, 990 Ltr inbuilt fuel tank. The DG Sets shall
be suitable for being overloaded upto 10% of the rated capacity for 1
hour in every 12 hours and consisting of the followings: The DG set
shall be suitable for above 0.85 loading factor with net output shall be
800 kVA as per site conditions with Genset governing Class G3 as per
IS 8528. Silent Diesel Genset shall be provided with remote monitoring
system to monitor the genset operational parameters at
desktop/smartphones.
A. DIESEL ENGINE:
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Diesel Engine 4 stroke water cooled, electric start, of suitable BHP at
1500 RPM suitable for above output of alternator at 40 Degree C, 50%
RH & at 1000 MSL and conforming to BS 5514, BS 649, IS 10000,
capable of taking 10% over loading for one hour after 12 hours of
continuous operation. The engine will be fitted complete with all the
required accessories.
Type: Radiator Cooled
Fuel injection :As per manufacturer
Engine Starting : Battery starting.
Starting position : Universal. Auto/Manual
The Engines shall include:
• Flywheel with guard.
• Flexible connection.
• Bellow / expansion joints
• Electronic governor with electronic fuel injection system
• Fuel and lube oil filters and pumps
• Day Fuel tank with visual level indicators etc.
• Silencer as per latest amendments of MOEF/CPCB
• Safety controls
• Instrument panel
• Exhaust piping to let out the exhaust at mandatory height above the
canopy including support arrangement and insulation with cladding
inside the canopy etc.
Synchronous alternator rated at 800 KVA, 415 volts at 1500 RPM, 3
phase 50 HZ, AC supply with 0.8 lagging power factor at 40 Degree C,
50% RH & at 1000 Meter MSL. The alternator shall be having SPDP
enclosure, brushless, continuous duty, self excited & self-regulated
through suitable AVR conforming to site condition and with Class-H
Type : Brushless.
Actual Power 800 KVA at 40 deg C.
Frequency : 50 Cycles/sec.
Supply System: 3 phases & neutral
Connection : Star.
Rated rpm. : 1500 RPM
Casing protection : As per IP-23
Insulation : Class H.
Power Factor : 0.8.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Controller : The DG sets should be suitable for Auto ON/OFF or
equivalent including providing of Engine control panel.
C. ACCESSORIES:
The Diesel Engine shall be equipped with minimum following/ as
indicated in the specifications, devices/ accessories built-in type
including all standard fittings.
Fuel supply pump with manual venting pump.
Turbo charger with air filter (dry/oil bath type) and damper.
Charge air cooler.
Suction fuel filter
Lube oil filter.
Hour meter and RPM indicator.
Battery Starting Mechanism.
Instrument/Indication panel complete with the followings;
a) Starting Switch with key.
b) Lub. Oil Temp. gauge.
c) Lub. Oil Pressure Gauge.
d) Water Temp. gauge.
Control devices for safety and monitoring along with indicators.
Common base/foundation frame.
Anti vibration pads
24V DC Starting system comprising of starter motors: Voltage
regulator and arrangement for initial excitation complete with suitable
nos. of Maintenance free batteries as per manufacturer standards for
minimum 6 no. consecutive starts as required as per specifications.
The cost of initial charge of lubricants, coolant etc.
The DG sets shall include the cost of all accessories, fittings,
protections, instruments, safety controls, alarms, indications etc.
complete as per specifications, as required
Supply, installation, testing & commissioning of 990 litres capacity day
oil storage tank fabricated from 6 mm thick MS plates. Tank shall
45 6.3 include 450 mm ID manhole cover, level indicator with duly calibrated 4 39,801 1,59,204
scale and flanged connection for inlet, outlet, overflow drain and probe
provision for level controller & breather. Set
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supply, installation, testing & commissioning of the following MS class
‘C’ pipes cut to required lengths and installed with all welded joints.
46 6.4 Providing the necessary fittings like elbows, tees and reducers, sockets,
hot dip galvanized supports and accessories including ceiling Hanger,
Hardware complete as per site requirement.
46.3 6.4.3 Providing 25 mm dia. ball valves Nos. 4 1,104 4,416
46.4 6.4.4 Providing 20 mm dia. ball valves Nos. 4 828 3,312
Supplying & fixing exhaust gas piping of suitable dia. Welded black MS,
B class pipe confirming to IS:3589 cut to required lengthsand installed
47 6.5 with necessary bends, supports and clamps, anti-vibration mountings,
insulation of exhaust system with mineral wool/rockwool, 50mm thick
wiremesh & aluminium clading etc, as required as per specification.
Providing and fixing in position following size of heavy duty stainless
steel flanged expansion bellows with G.I. nut bolt washers for DG fume
piping complete with GI nut bolt washers etc. complete as required.
Providing & fixing for MS support structure for exhaust fume pipes from
DG Sets (Exhaust pipe to be measured and paid for separately) along
horizontal and vertical runs upto the height (as per CPCB norms)
including cutting, welding etc. and applying two coats of red oxide and
49 6.7 two coats of synthetic enamelled paint of colour and shade as directed KG 4000 117 4,68,000
by engineer-in-charge. The design of the support structure shall be
done by the contractor and shall be as per CPCB norms approved , also
to get the approval from the client/ consultant before execution etc. as
Total of Sub-Head - X carried to summary sheet 0 266,49,208
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
50 NS.-7 Sub-Head - XI - LT PANEL & DISTRIBUTION PANEL WORK .
A. ALL LT PANELS SPECIFIC INCLUSIONS:
The outgoing feeders as indicated in SLD shall have suitable range of
followings (except capacitor feeders).
All ACB's shall be suitable for minimum 50 kA as specified in the items
(Icu=Ics=Icw for 1 sec.)
All MCCB's shall be suitable for unless otherwise specified in the item
(Icu=Ics= 1 sec=100%.)
Wiring with space heater, thermostat and control MCB's shall be
provided for all vertical sections of main LT panel.
All incoming as well as outgoing feeders shall have pad locking facility.
Suitable danger board shall be provided.
All MCCB’s shall be provided with front rotary handle and operating
mechanism for door interlock with Pad locking of MCCB’s handles in
“OFF” Position.
The Panel fabricator shall provide Al./ Copper Bus-bars link from
Breakers wherever more than two nos. of cables are terminated in the
All incoming and outgoing air circuit breakers shall be placed on middle
portion of the vertical in single tier formation.
All distribution sub panels shall be provided with class 1.0 accuracy
meters as well as CTs.
All hinged door shall be earthed through 2.5 sq mm tinned braided
Panels shall be Powder Coated with Siemens grey paint shade no. RAL-
All motor feeders MCCBs shall be of motor duty.
Supporting/Base rigid steel framework.
4P ACB’s / MCCB’s shall mean 4 pole ACB’s / MCCB’s with adequate
size of neutral link.
All MCCB above 250A shall be microprocessor base.
B BACK ACCESS PANELS WITH ACB's
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supply, installation, testing & commissioning of cubical type LT panel
suitable for 415V, 3 phase, 4 Wire 50 Hz AC supply system fabricated
in compartmentalized (preferably) design from CRCA sheet steel of 2
mm thick for frame work & covers, 3mm thick for gland, plates i/c
cleaning & finishing complete with 7 tank process for power coating in
approved shade, having 2000 Amp capacity extensible type TPN
aluminium alloy busbar of high conductivity, DMC/SMC bus bar of high
conductivity, DMC/SMC bus bar supports, with short circuit withstand
capacity of 31 MVA for 1 second, bottom base channel of MS secton not
less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in
transportable sections, entire panel shall have common copper earth
bar of size 25 mm x 5 mm at the rear with 2 nos. earth stud, solid
connections from main busbar to switch gears with required size of Al.
bus bars and control wiring with 2.5sqmm PVC insulated copper
conductor S/C cable, cable alleys, cable gland plates in two half, i/c
providing following switch gears.
(Note: The contractor may select the next higher fault rating of
ACB/MCCB if it is not readily available ,without any extra cost.)
51 7.1 MAIN LT Panel- FOR ACADEMIC BLOCK & ESSENTIAL SERVICES
A From 1600 KVA Transformer
2 Nos. of 2500 A, 4P electrically operated Drawout type ACB with
Ics=Ics=50KA having Mircroprocessor based releases for O/L, S/C &
E/F protection.
2 Nos. SPD Type 1
2 Sets - digital multifunction meter (showing harmonics along with all
other electrical parameters such as voltage, current, Hz, KW, KWHr,
PF.) with RS 485 port with matching cast resin CT's
2 Sets - 0-500V, digital Voltmeter with selector switch, 3 No. phase
indicating LED lamp to show the incoming power with control SP MCB.
2 Sets indicating LED lamps for ACB On/Off/ Trip with protective SP
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
2 Sets of CTs of the ratio 2000/5A, Class-1 for APFC Relay, Burden 15
2 Sets of CTs of the ratio 2000/5A with Class 1 Accuracy for Metering,
2 Nos. 2000/5A , 15 VA, Class-5P10 CT's for Protection
2 No. Under Voltage relay
2 Nos. Negative Phase protection Relay
2 Nos. over Voltage relay
2 Nos. Over Current Relay & earth fault relay
2 Nos. Over & under frequency relay
B From 1010 KVA D.G. Set
2 Nos. of 1600 A, 4P electrically operated Drawout type ACB with
Ics=Ics=50KA having Mircroprocessor based releases for O/L, S/C &
E/F protection.
2 Nos. SPD Type 1
2 Sets - digital multifunction meter (showing harmonics along with all
other electrical parameters such as voltage, current, Hz, KW, KWHr,
PF.) with RS 485 port with matching cast resin CT's
2 Sets - 0-500V, digital Voltmeter with selector switch, 3 No. phase
indicating LED lamp to show the incoming power with control SP MCB.
2 Sets indicating LED lamps for ACB On/Off/ Trip with protective SP
2 Sets of CTs of the ratio 1600/5A with Class 1 Accuracy for Metering,
2 Nos. 1600/5A , 15 VA, Class-5P10 CT's for Protection
2 No. Under Voltage relay
2 Nos. over Voltage relay
2 Nos. Over Current Relay & earth fault relay
2 Nos. Over & under frequency relay
C From 750 KVA D.G. Set
2 Nos. of 1250 A, 4P electrically operated Drawout type ACB with
Ics=Ics=50KA having Mircroprocessor based releases for O/L, S/C &
E/F protection.
2 Nos. SPD Type 1
2 Sets - digital multifunction meter (showing harmonics along with all
other electrical parameters such as voltage, current, Hz, KW, KWHr,
PF.) with RS 485 port with matching cast resin CT's
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
2 Sets - 0-500V, digital Voltmeter with selector switch, 3 No. phase
indicating LED lamp to show the incoming power with control SP MCB.
2 Sets indicating LED lamps for ACB On/Off/ Trip with protective SP
2 Sets of CTs of the ratio 1250/5A with Class 1 Accuracy for Metering,
2 Nos. 1250/5A , 15 VA, Class-5P10 CT's for Protection
2 No. Under Voltage relay
2 Nos. over Voltage relay
2 Nos. Over Current Relay & earth fault relay
2 Nos. Over & under frequency relay
TPN aluminium bus bars of minimum of 3000 Amps capacity with heat
shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section,
size supports & their spacing etc. for withstanding fault level of 31 MVA
E BUS COUPLER:-
2 No. of 2500 A, 4P electrically operated Drawout type ACB with
Ics=Ics=50KA having Mircroprocessor based releases for O/L, S/C &
E/F protection.
1 Set of Breaker ON-OFF indication Lamps as required.
Electrical through advance contacts in MCCB/ACB's (Incomer & bus
couplers) & mechanical (castel key) interlocking should be provided to
ensure that only one supply is available at a time on each section of
bus & to eliminate any possibility of accidentlly approaching two
supplies at one bus section.
F OUTGOINGS-Bus Section-1
i) 1 No. 1250A 4P ACB (50 KA)
ii) 2 Nos. 800A 4P ACB (50 KA)
iii) 2 Nos. 300A 4P MCCB (36 KA)
iv) 1 No. 250A 4P MCCB (25 KA)
v) 1 No. 100A 4P MCCB (25 KA)
vi) 1 No. 40A 4P MCCB (25 KA)
G OUTGOINGS-Bus Section-2
i) 1 No. 1250A 4P ACB (50 KA)
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
ii) 1 No. 800A 4P ACB (50 KA)
iii) 1 No. 630A 4P MCCB (36 KA)
iv) 2 Nos. 300A 4P MCCB (36 KA)
v) 1 No. 250A 4P MCCB (25 KA)
vi) 1 No. 100A 4P MCCB (25 KA)
vii) 2 Nos. 40A 4P MCCB (25 KA)
PLC FEEDER- FOR AMF FOR AUTO ON/OFF THE DG, LOAD
MANAGEMENT & E/M INTERLOCKING :
Hardware using PLCs for Monitoring of all Electrical Software and for
operations, controlling and interlocking Parameters of 2 Nos. I/C from
Transformer & 4 Nos. DG Set with Window based software &
Engineering & Software Development. Required Aux. Relays, Push
Buttons & Indication lamps, 1KVA UPS for Black start & maintenance
free Batteries, Power monitors, Programmable Logic controller,
Annunciator and status Fascia, MIMIC with LED circuit etc as required
completing the system.
The Switchboard with Logic control panel shall be complete with all
interconnections, risers, internal wiring, labels, control/circuit fuses etc.
complete as required.
Note: Incomer from LT Supply, D.G. set & Bus coupler shall be
electrically & mechanically interlocked.
Main LT Panel as described above Set 1 67,72,719 67,72,719
The outgoing feeders as indicated in SLD shall have suitable range of
followings (except capacitor feeders)
Three phase indicating lamps protected by 2 amps SP MCBs.
ii. All ACB's shall be suitable for minimum 25 kA ( Icu=Ics=Icw for 1 sec.)
415/110V suitable rating control transformer and shall be provided for
aux. control supply.
Wiring with space heater, thermostat and control MCB's shall be
provided for all vertical sections of main LT panel.
All breakers shall be interlocked as per schematic diagram through Mini
vi. All incoming as well as outgoing feeders shall have pad locking facility.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
vii. Suitable danger board shall be provided.
Incase of Fire, Fire pumps along with other ventilations and
viii pressurization fans designed shall become operational. Interlocking
with LT panel shall be carried out accordingly.
MAIN LT Panel 2- FOR HOSTEL BLOCKS(UG BOYS, UG GIRLS
A From 300 KVA Transformer
1 No. 630 A, 4P MCCB(36KA) having Mircroprocessor based releases
for O/L, S/C & E/F protection.
1 No. SPD Type 1
1 Set - digital multifunction meter (showing harmonics along with all
other electrical parameters such as voltage, current, Hz, KW, KWHr,
PF.) with RS 485 port with matching cast resin CT's
1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase
indicating LED lamp to show the incoming power with control SP MCB.
1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP
1 Set of CTs of the ratio 600/5A, Class-1 for APFC Relay, Burden 15 VA
1 Set of CTs of the ratio 600/5A with Class 1 Accuracy for Metering,
1 No. 600/5A , 15 VA, Class-5P10 CT's for Protection
1 No. Under Voltage relay
1 No. over Voltage relay
TPN aluminium bus bars of minimum of 800 Amps capacity with heat
shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section,
size supports & their spacing etc. for withstanding fault level of 31 MVA
i) 1 No. 250A 4P MCCB (25 KA)
ii) 3 Nos. 200A 4P MCCB (25 KA)
iii) 1 No. 63A 4P MCCB (25 KA)
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Main LT Panel 2 as described above Set 1 3,74,143 3,74,143
53 7.3 MAIN LT Panel 3- FOR RESIDENCE BLOCKS
A From 250 KVA Transformer
1 No. 500 A, 4P MCCB(36KA) having Mircroprocessor based releases
for O/L, S/C & E/F protection.
1 No. SPD Type 1
1 Set - digital multifunction meter (showing harmonics along with all
other electrical parameters such as voltage, current, Hz, KW, KWHr,
PF.) with RS 485 port with matching cast resin CT's
1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase
indicating LED lamp to show the incoming power with control SP MCB.
1 Set indicating LED lamps for MCCB On/Off/ Trip with protective SP
1 Set of CTs of the ratio 500/5A, Class-1 for APFC Relay, Burden 15 VA
1 Set of CTs of the ratio 500/5A with Class 1 Accuracy for Metering,
1 No. 500/5A , 15 VA, Class-5P10 CT's for Protection
1 No. Under Voltage relay
1 No. over Voltage relay
TPN aluminium bus bars of minimum of 600 Amps capacity with heat
shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section,
size supports & their spacing etc. for withstanding fault level of 31 MVA
i) 5 Nos. 160A 4P MCCB (25 KA)
ii) 7 Nos. 100A 4P MCCB (25 KA)
Main LT Panel 3 as described above Set 1 5,48,784 5,48,784
54 7.4 Capacitor Panel (550 kVAR)
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
1 No. 800A TP ACB (50 KA).
B METERING & INDICATION
i) 1 set of phase indicating lamps
1 No. 12 step-Microprocessor APFC controller/Relay(Dual source
purpose) shall continuously monitoring all three phases and LCD
displays for various Electrical Parameters like voltage, input current,
capacitive current, KVA demand, KW, Power Factor, self diagnostic
error code indication with printout facility of the above with RS 232/RS
485 port. Controller should mounted on the front side of the panel.
Capacitor bank having 3 phase MPP based mix dieelectric low loss ISI
marked power capacitor and provided with capacitor duty contactor.
1 Set of 1000A TPN Aluminium Bus Bar with colour coded PVC Sleeves
i) 2 Nos.of 250A TP MCCB (25 KA) each with
2 Nos. 100 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
ii) 5 Nos.of 125A TP MCCB (25 KA) each with
5 Nos. 50 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
iii) 3 Nos.of 80A TP MCCB (25 KA) each with
3 Nos. 25 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
iv) 1 No. of 32A TP MCCB (25 KA) each with
1 No. 15 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
v) 1 No. of 25A TP MCCB (25 KA) each with
1 No. 10 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
Capacitor Panel (550 kVAR) as described above Set 2 10,74,654 21,49,308
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
415/110V suitable rating control transformer and shall be provided for
aux. control supply.
Wiring with space heater, thermostat and control MCB's shall be
provided for all vertical sections of main LT panel.
iii All breakers shall be interlocked as per schematic diagram.
iv All incoming as well as outgoing feeders shall have pad locking facility.
v Suitable danger board shall be provided.
54 7.5 Capacitor Panel (170 kVAR)
1 No.250A TP MCCB (25 KA).
B METERING & INDICATION
i) 1 set of phase indicating lamps
1 No. 7 step-Microprocessor APFC controller/Relay(Dual source
purpose) shall continuously monitoring all three phases and LCD
displays for various Electrical Parameters like voltage, input current,
capacitive current, KVA demand, KW, Power Factor, self diagnostic
ii) error code indication with printout facility of the above with RS 232/RS
485 port. Controller should mounted on the front side of the panel.
Capacitor bank having 3 phase MPP based mix dieelectric low loss ISI
marked power capacitor and provided with capacitor duty contactor.
1 Set of 300A TPN Aluminium Bus Bar with colour coded PVC Sleeves
i) 1 No. of 125A TP MCCB (25 KA) each with
1 No. 50 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
ii) 4 Nos.of 80A TP MCCB (25 KA) each with
4 Nos. 25 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
iII) 2 Nos. of 25A TP MCCB (25 KA) each with
2 Nos. 10 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
Capacitor Panel (170 kVAR) as described above Set 1 4,73,914 4,73,914
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
55 7.6 Capacitor Panel 80 kVAR)
1 No.160A TP MCCB (25 KA).
B METERING & INDICATION
i) 1 set of phase indicating lamps
1 No. 6 step-Microprocessor APFC controller/Relay(Dual source
purpose) shall continuously monitoring all three phases and LCD
displays for various Electrical Parameters like voltage, input current,
capacitive current, KVA demand, KW, Power Factor, self diagnostic
ii) error code indication with printout facility of the above with RS 232/RS
485 port. Controller should mounted on the front side of the panel.
Capacitor bank having 3 phase MPP based mix dieelectric low loss ISI
marked power capacitor and provided with capacitor duty contactor.
1 Set of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
i) 2 Nos.of 80A TP MCCB (25 KA) each with
2 Nos. 25 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
ii) 2 Nos. of 25A TP MCCB (25 KA) each with
2 Nos. 10 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
iII) 2 Nos. of 25A TP MCCB (25 KA) each with
2 Nos. 5 KVAR MPP Heavu Duty capacitor Bank each with capacitor
duty contactor.
Capacitor Panel (80 kVAR) as described above Set 1 3,92,298 3,92,298
55 FRONT OPERATED PANEL
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supply, installation, testing and commissioning of front operated, front
access, totally enclosed, free standing, dust and vermin proof Panel
with IP65 ingress protection, fabricated from 2 mm thick CRCA sheets,
with hinged, gasketted and lockable doors including the cost of
interconnections, copper crimping lugs, brass glands, bonding to earth
and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz
system with 31 MVA rupturing capacity at 415 volts complete as per
specifications, as required and as below.
56 7.7 External lighting Feeder piller-1
1 No. 40A,4P MCCB (25kA) and ON/OFF indicating lamps.
1 No. 40A, 3 phase Timer Switch for automatic operation.
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps.
1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB.
iii) 1 No. (0-40A) Ammeter with ASS with 3 nos. 160/5A CT's.
1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves.
12 nos 16 Amp 4P MCB, 10 KA.
Sub External lighting Feeder piller-1 described as above Set 1 96,033 96,033
57 7.8 External lighting Feeder piller-2
1 No. 40A,4P MCCB (25kA) and ON/OFF indicating lamps.
1 No. 40A, 3 phase Timer Switch for automatic operation.
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps.
1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB.
iii) 1 No. (0-40A) Ammeter with ASS with 3 nos. 160/5A CT's.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves.
6 nos 16 Amp 4P MCB, 10 KA.
Sub External lighting Feeder piller-2 described as above Set 1 96,033 96,033
58 7.9 External lighting Feeder piller-3
1 No. 40A,4P MCCB (25kA) and ON/OFF indicating lamps.
1 No. 40A, 3 phase Timer Switch for automatic operation.
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps.
1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB.
iii) 1 No. (0-40A) Ammeter with ASS with 3 nos. 160/5A CT's.
1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves.
12 nos 16 Amp 4P MCB, 10 KA.
Sub External lighting Feeder piller-3 described as above Set 1 75,781 75,781
Total of Sub-Head - XI carried to summary sheet 0 109,79,013
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
59 NS - 8 Sub-Head - XII - EXTERNAL LIGHTING WORK
Supply, installation, Testing & commissioning of 7000 mm Decorative
poleMade of mild steel galvanized pole with mild steel galvanized
decorative double arm bracket. Pole & brackets are painted with PU
59.1 8.1 paint & pole iscomplete with service window containing 6-amp MCB, 4- Nos. 2 50,989 1,01,978
way connecter, pole is with embellishments at middle & bottom.
Supply, installation, Testing & commissioning of 5000 mm Decorative
poleMade of mild steel galvanized pole with mild steel galvanized
decorative single arm bracket. Pole & brackets are painted with PU
59.2 8.2 paint &pole is complete with service window containing 6-amp MCB, 4- Nos. 160 34,986 55,97,760
way connecter, pole is with embellishments at middle & bottom.
Supply, installation, Testing & commissioning of 3000 mm Decorative
poleMade of mild steel galvanized& are painted with PU paint & pole is
complete with service window containing 6-amp MCB, 4-way connecter,
59.3 8.3 pole is with embellishments at middle & bottom. Nos. 35 13,600 4,76,000
Supply, installation, Testing & commissioning of Modern 120-watt
decorative Hanging Street light made of die cast aluminum housing
59.4 8.4 with high powered LED, A UV stabilized PC/PMMA diffuser is provided Nos. 4 25,605 1,02,420
for glare free lighting with high visual comfort. Available in
Supply, installation, Testing & commissioning of Modern 90-watt
decorative Hanging Street light made of die cast aluminum housing
59.5 8.5 with high powered LED,A UV stabilized PC/PMMA diffuser is provided for Nos. 160 23,177 37,08,320
glare free lighting with high visual comfort. Available in 3000k/6000k.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supply, installation, Testing & commissioning of 40-watt decorative
post top light made of spun aluminum housing with power LED, A UV
59.6 8.6 stabilized PC/PMMA diffuser is provided for glare free lighting with high Nos. 35 8,222 2,87,770
visual comfort. Available in
Supply, installation, Testing & commissioning of Post Top Gate 21W
Post Top LED Light luminaries, made up of die cast aluminium body
duly powder coated , provided with polycarbonate diffusers duly
59.7 8.7 gasketed, integral driver, connectors all duly wired , connection & Nos. 6 9,492 56,952
wiring from junction box with 3# 2.5 sqmm copper wires, Mounted on
existing gate column.
Supply, installation, testing and commissioning of LED Bollard Light.
Luxmax, Klite, bajaj.
Supply of 80W LED floolight luminaire for building highlighte.
Supply, installation, testing & commissioning of 45W Standalone Solar
LED Street lighting with 3 M long tubular pole 4 mm thick, SA 0.5 mtr
long bracket. The average thickness of galvanization is 80 Microns or
more. The solar lighting system will be supplied along with Solar Gel
battery, TUV certified PV module of adequate capacity to provide 36
Hrs back up complete with all accessories & Metallic Battery box.
13 METER HIGH MAST : SUPPLY & INSTALATION
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supply, instalation, testing & commissioning of 13 Mtr High Mast
System hot dipgalvanised (singledip) and suitable for wind velocity as
per IS875 part3, with lowering and raising motorized unit, with
carriage assembly for 6 - 8 Luminaries and its control gear box,
lighting stand and avaition light and lightning arrestor. The mast shall
be in three finished sections.It shall also include accessories for 13 Mtr
high mast including head frame,steel wire rope 6mm dia,trailing
cable,double drum winch,galvanized lantern carriage arrangement
suitable for 12 luminaires symmetrically & its control gear boxes and
lighting finial with internal power tool.
59.11 8.11 Supply, instalation, testing & commissioning of foundation bolts Set 5 3,14,545 15,72,725
manufactured from special steel alongwith nuts,washers, anchor plates
& templates. 2 Nos.
Supply, instalation, testing & commissioning of control panel with
suitable control curcuit for automatic switching ON and OFFof the mast.
It shall also have suitable controls for operation of Power Tool. 1 No.
Supply, instalation, testing & commissioning of 2 X 400W non integral
flood light luminaire with pressure die cast aluminium housing & heat
resistant toughened flat glass(IP 65) complete with external single
control gear box.
Total of Sub-Head - XII carried to summary sheet 0 273,27,665
Sub-Head - XIII - SUPPLY OF HT & MV CABLE WORK
60 NS-9 Supply of HT cable
Supplying of following sizes of XLPE aluminium conductor, corss linked
polythylene, individual core screwed, flat steel strip armoured, PVC
sheathed cable of 33KV grade (earthed) comforming to IS: 7098 (Part
2),with uptodate ammendment complete as required.
3 C x 300 Sq.mm XLPE HT cable (Earthed) mtr 2000 3,775 75,50,000
61 NS-10 Supply of MV cable
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium
conductor/copper conductor power/ multicore control armoured cable
of 1.1 KV grade.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
61.6 10.6 3 ½ C - 70 sq mm Aluminium Metre 130 562 73,060
61.7 10.7 3 ½ C - 50 sq mm Aluminium Metre 65 418 27,170
61.8 10.8 3 ½ C - 35 sq mm Aluminium Metre 40 324 12,960
61.9 10.9 4 C - 16 sq mm Aluminium Metre 30 208 6,240
61.11 10.11 3 C - 10 sq mm Aluminium Metre 50 163 8,150
61.12 10.12 3 C - 6 sq mm Aluminium Metre 50 130 6,500
61.13 10.13 2C- 6 sq mm Aluminium Metre 50 112 5,600
Total of Sub-Head - XIII carried to summary sheet 0 195,79,920
62 NS-11 Sub-Head - XIV- SAFETY EQUIPMENT WORK
62.1 11.1 Providing and fixing NO SMOKING & DANGER ZONE signboards. Nos. 2 248 496
Providing and fixing of a set of 4 nos. fire bucket of 9 lit. capacity made
of 24 gauge MS sheet on fabricated angle iron frame(Comprising of
32x32x5mm angle iron duly primer & painted with P.O. red colour
complete in all respect. Nos. 4 690
Providing and fixing ISI marked CO2 4.5 Kg. Capacity as per latest IS.
Providing and fixing ISI marked Chemical foam type of 9 liters as per
latest IS (trolley marker). Nos. 2 8,277
Providing and fixing ISI marked Dry chemical powder type (5 Kg.) as
per latest IS. Nos. 2 3,449
Supply and fixing of approved shock treatment chart in position &
62.4 11.6 written in English and Hindi. The chart shall be framed using wooden 690
frame and glass having minimum 8 mm thickness. Nos. 1 690
63 11.7 Insulating Mats
Supply, installation, testing commissioning of Insulating Mats of size
1m x 2m x 2.5mmm for AC rms voltage grade up to 11 kV tested with
dielectric strength of 45 kV of B Class, fire retarded complete in all
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
64 11.8 FIRST AID BOX
Supplying of the first aid box containing the items approved by Indian
red Cross complete as required as given.
2 absorbent compress dressings (5 x 9 inches)
25 adhesive bandages (assorted sizes)
1 adhesive cloth tape (10 yards x 1 inch) 2,760
5 antibiotic ointment packets (approximately 1 gram)
5 antiseptic wipe packets
2 packets of aspirin (81 mg each)
Total of Sub-Head - XIV carried to summary sheet 0 77,340
Sub-Head - XV- EXTERNAL VIDEO SURVEILLANCE SYSTEM (IP
Supply, Installation, Testing and Commissioning of 5 MP IP Bullet CCTV
Camera along with all mounting accessories ,1/2.8'' 5 .1MP CMOS
Sensor with effective 2592(H) X 1944(V) pixels, Motorized varifocal
lens 6~50mm(F1.4) , Video Compression H.265, H.264,M-JPEG , Color:
0.08Lux)/F2.0, 0 Lux (IR On), IR Distance 120ft, High WDR 120dB , P
Iris , Dual Streaming , Frame rate Upto 30FPS, Sutter speed Auto /
65.1 12.1 Manual (1/15 ~ 1/60000), Slow Shutter(off, 2x~8x) ,3D DNR , Support Each 41 1,05,538 43,27,058
SD Card , Audio Input & Output , Alarm Input & output , Polygon
motion detection , Privacy masking, ONVIF Profile S , Ethernet port
10/100 Mbps, 12DC, PoE, Metal body, IP66 & IK 10 protection as per
detail tender specification , Certificate BIS, CE , FCC & RoHS. Make:
Arecont Vision/Wavesys/ Oncam/ Mobotix
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supply of 360 deg outdoor Dome IP Camera with 12.4 Megapixel CMOS
digital image sensor providing recording resolution 9MP, minimum 45
FPS @ 9MP, support four independent stream simulaneously, main
stream 45fps @ 9Mp, constant 25fps @ 9 MP when using High
WDR@100dB. H.264 & H.265 compression, constant 360 degee
recording along with simultaneous multiple angles of view using one
sensor,3D client side dewarping with no blind spots with IP67 & IK10
Vandal-resistant dome cover ,support Audio in/out,hardware alarm
input/output contacts, Colour based Compression for reducing the
bandwidth, Polygon motion detection minimum 10 regions, privasy
masking 4 regions ,support SD card Upto 512 GB ,support multi users
minimum 20 users ,support mobile application for 3D dewarping,
support onvif profile S&G. Working temprature -20 to + 55 °C.
Sunshield and Pole / Wall / Pendant Mount from the same make as
Camera. EN,FCC, CE and BIS certified. Arecont Vision/Wavesys/
Supply, installation, testing & commissioning of Video Management
Software for Viewing, Recording, Monitoring all the camera, capable of
65.3 12.3 Analytics and VMS on single server. Arecont Vision/Wavesys/ Oncam/ Each 72 8,071 5,81,112
Supply of Windows OS 10 Based Pro 64 Bit Grade Video Recorder with
Intel Core 2 Quad Processor, 128 GB DDR RAM,NVIDIA Quadro P4000
(4GB GDDR5),64 Channel Support with Minimum 32 Channel Client
Side Dewarping Support, 64TB RAID 5 enterprise grade SATA HDD with
48 TB Usable for 30 days storage 1080p, loaded with enterprise grade
65.4 12.4 64 bit Video Management software supporting maps with alerts on Each 2 4,78,026 9,56,052
maps, edge recording, advance event and action manager, video
content analytics support, 12 megapixel camera support with Live
stream on mobile, geotagging and compatibility to chromecast devices.
Supply, installation, testing & commissioning of 4 TB Video Survillance
Hard disk drive
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supply, installation, testing & commissioning of 8 Port Layer 2
65.6 12.6 Managed access PoE/PoE+ switch with 8x1G Base-T PoE+ and 4x1G Each 28 43,457 12,16,796
Supply, installation, testing & commissioning of 24 Port Layer 2
Managed access PoE/PoE+ switch with 24 10/100/1000 Base-T
PoE/POE+ Ports and additional 4 1G SFP ports with PoE budget of
Supply, installation, testing & commissioning of 24 Port Layer 3 Core
65.8 12.8 Switch with 24x1G SFP/24X1G T Combo Ports with 4x1G/10G SFP+ Each 1 2,79,366 2,79,366
Supply, Installation ,Testing and Commissioning of 32" LED colour Full
HD TV monitor for live view and replay of recorded View with mounting
stand & HDMI cable
Supply, installation, testing & commissioning of Intel Core i7
generation 7th or better, with min 8MB Cache, 1xSata HDD Bay
support, DVD R/W, Dedicated Graphics Card of 4GB minimum, 32GB
65.10 12.1 DDR 4 RAM, min 6 USB ports, with multimedia keyboard mouse and Each 4 1,24,162 4,96,648
HDMI monitor slots with capability of connecting minimum 2 monitors,
with minimum 1TB HDD running latest compatible Windows OS with
ANtivirus subscription for 3 years from Mcafee/Kaspersky/Norton.
Supply fitting, fixing and testing of 6 U Wall/Pole mount weather proof
65.11 12.11 rack for keeping switch & other items in the filed along with all Each 28 9,312 2,60,736
required acessories .
Supply fitting, fixing and testing of 24 U Rack fully loaded with wheels
for keeping Control room accessories.
Supply , Installation , Testing and Commisioning of 1KVA online UPS
65.13 12.13 with inbuilt battery for field equipments, 30mins backp on full load with Each 28 18,624 5,21,472
3 yrs warranty.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing
surface/ recessed Steel/ PVC conduit as required.
1.53.1 1 run of cable Metre 2240 49 1,09,760
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supplying and drawing following sizes of FRLS PVC insulated copper
65.15 DSR-1.17 conductor, single core cable in the existing surface/ recessed steel/
PVC conduit as required.
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supplying and fixing of following sizes of medium class PVC conduit
65.16 DSR-1.21 along with accessories in surface/recess including cutting the wall and
making good the same in case of recessed conduit as required.
Supplying and Laying of 6 Core Armoured OFC cable from Security
65.17 12.14 Room to required Junction Box (6U Rack), splicing & termination etc. Metre 2240 81 1,81,440
Supply , Installation , Testing and Commisioning of 12 Port LIU rack
mount fully loaded boxes for 6U rack as required.
65.19 12.16 Supply, Installation, Testing and Commisioning of RJ45 Connectors Each 400 348 1,39,200
Supply, Installation, Testing and Commisioning of 6Mtr Pole for
installation of camera.
Total of Sub-Head - XV carried to summary sheet 3,90,080 137,39,511
SUB HEAD-XVI : ANNUAL operation and maintenance of HVAC
Operation and Comprehensive AMC of Complete HVAC system including
4 numbers Water Cooled Screw Chilling machine of 1200 TR with
cooling tower, precision air conditions and ductable units installed and
run for Academic and Administrative buildings, including all AHU's,
FCU's, Chilled Water Pumps and Condenser Water Pumps including
HVAC Electrical panel & Switch gears, all valves, Consumables such as per
66.1 21.1 Filters, Compressor Oil etc. Operation and Comprehensive AMC of mont 12 5,65,883 67,90,594
Complete water softening system with plant for chilled water screw h
plant with piping and electrical panel and its valves with all accessories
required to complete and smooth running of systems including all
materials and accessories required complete in all respect as per
direction of Engineer-in-charge
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Total of Sub-Head - XVI carried to summary sheet 0 139,20,717
SUB HEAD-XVII : ANNUAL Operation and maintenance of LV, IT,
BMS etc. system
Comprehensive Annual operation and Maintenance For complete LV
works of the campus with Equipment Like IT & Security System, per
66.1 22.1 Automatic fire alarm, Building Management System, Audio visual mont 12 11,31,066 135,72,789
Total of Sub-Head - XVII carried to summary sheet 0 278,24,217
67 NS-23 SUB HEAD-XVIII : 200 KW GRID TIE SOLAR PV SYSTEM
Supply, Installation, testing & Commissioning of solar module,
necessary electrical cables to connect solar cells together and to the
DB's as well as inverters to have a complete operational circuit,
Conduits, cable trays, trucking, earthing system and complete Main
67.1 23.1 Junction Box according to the drawings and engineer's instruction and Set 1
approval. Price will include all materials needed to connect from
modules to inverter and have complete job ready for installing high
quality PV modules connected. Price shall include costs of repairing any
BOQ- Ext. Dev., Datia, MP
Amount Amount Non
Description Unit Total Qty Rate (Rs) Schedule Schedule
Items( Rs ) Items( Rs )
Supply, Installation, testing & Commissioning of Module mounting
Structure according to the detailed drawing and approval by the
Engineer-in charge. Contractor should submit shop drawing for proper
67.2 23.2 mounting structure. Rate shall include aluminium anodized/ HD KW 200
galvanized structure, supports, plates & screws, bracing and angles for
dividers etc to complete the structure. Rate shall include excavation,
concreting and fixing of structure.
Supply, Installation, testing & Commissioning of 200kW 1P grid tie
inverter with minimum 2 MPPT inputs. The inverter depending on the 72,264
system design and installation proposed. The inverter unit shall be
suitable for indoor and outdoor installations. Cable terminations to
inverter shall be of type DC plug and socket connectors. Technical
literature has to be provided as generated by the inverters
manufacturer software. Inverter shall allow an adjustable power factor
outdoor, minimum AC output power 200 kw, with all necessary
electrical cables, Conduits and trays and all other materials and
workmanship needed to connect with the main distribution panel
according according to the drawings and engineer's instruction and
approval complete in all respect to complete the work.
Supply, install, connect and operate 20KA DC SPD DC surge protector
for grid connected system . The Surge protector unit shall be suitable
for indoor and outdoor installations. The surcharge protector system
shall include all necessary electrical cables, Conduits and trays and all
other materials and workmanship needed to the system according to
the drawings and engineer's instruction and approval complete in all
respect to complete the work.
Total of Sub-Head - XVI carried to summary sheet 0 144,52,777
BOQ- Ext. Dev., Datia, MP
“Comprehensive External Development, horticulture, landscaping and other
miscellaneous works for College of Veterinary and Animal sciences and College of
Fisheries under Pkg-3 for RLBCAU, Datia, MP “
ABSTRACT OF COST (PHE WORK)
SL. NO. DESCRIPTION DSR 2018
1 EXTERNAL PHE WORKS
2 WTP- 110 KLD
6 OPERATION & MAINTENANCE FOR
STP, ETP & WTPS 80,22,414.00
GRAND TOTAL (SCH.+NON SCH.) 365,63,683.84
GRAND TOTAL (SCH.+NON SCH.) 365,63,683.84
“Comprehensive External Development, horticulture, landscaping and other miscellaneous works for College of
Veterinary and Animal sciences and College of Fisheries under Pkg-3 for RLBCAU, Datia, MP “
DSR 2018 Description UNIT RATE
2.6 Earth work in excation by mechanical means (hydraulic
excavator)/manual means over areas (exceeding 30cm in
depth, 1.5 in width as well as 10 sq.mt in plan) including
disposal of excavated earth lead upto 50m and lift upto 1.5 m
disposed earth to be levelled and neatly dressed.
2.7 Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth lead upto 50 m
and lift upto 1.5 m, as directed by Engineer-incharge.
2.7.3 Hard rock (blasting prohibited) cum 336.74 609.65 205293.541
2.10 Excavating trenches of required width for pipes, cables , etc.,
including excavation for sockets, and dressing of sides, ramming of
bottoms ,depth upto 1.5 m including getting out the excavated soil,
and then returning the soil as required, in layers not exceeding 20
cm in depth including consolidating each deposited layer by ramming
,watering ,etc. and disposing of surplus excavated soil as directed,
with in a lead of 50 m:
2.10.1 All kinds of soil
2.10.1.2 Pipes, cables etc, not exceeding 80 mm dia. metre 2968.00 223.00 661864
2.10.1.3 Pipes, cables etc, exceeding 80 mm dia.but not exceeding 300 mm metre 728.50 364.20 265319.7
2.25 Filling available excavted earth (excluding rock) in trenches, cum 425.73 219.65 93511.5945
plinth sides of foundations etc. in layet not exceeding 20 cm in
depth consolidation earth deposited layer by ramming and
watering lead upto 50m and lift upto 1.5m
2.27 Supplying and filling in plinth with sand under floors, including cum 15.69 1953.05 30643.3545
watering,ramming, consolidating and dressing complete.
2.26.1 Extra for every addition lift of 1.5 m or part thereof in cum 250.18 90.4 22616.272
excavation/ banking excavated or stacked materials. All kinds
2.26.2 Extra for every additional lift of 1.5 m or part thereof in cum 166.79 162.1 27036.659
excavation / banking excavated or stacked materials. Ordinary
23.8 Gravel packing in tube well construction in accordance with IS cum 10.6 1497.7 15875.62
4097, including providing graval fine/medium coarse, in
required grading & sizes as per actual requirement , all
complete as per direction of engineer-in charge.
23.13.2 Providing & fixing suitable size threaded mild steel cap or spot Each 5 210.75 1053.75
welded plate to the top of bore well housing/ casing pipe
,removable as per requirement,all complete for borewell of
23.15.2 Providing and fixing Bail plug/Bottom plug of required dia to each 5 280.95 1404.75
the bottom of pipe assembly of tubewell as per IS:2800 (Part-I)
18.12 Providing and fixing GI pipes complete with GI fittings
including trenching & refilling etc.
External works:
18.12.2 20 mm dia nominal bore Mtrs 40.00 283.8 11352
18.12.3 25 mm dia nominal bore Mtrs 60.00 364.55 21873
18.12.4 32 mm dia nominal bore Mtrs 75.00 424.7 31852.5
18.12.5 40 mm dia nominal bore Mtrs 163.00 483.15 78753.45
18.13 Making connection of GI distribution branch with GI main of
following sizes by providing & fixing tee, including cutting and
threading the pipe etc. complete.
18.72 Providing and laying S&S Centrifugally Cast (Spun) / Ductile
Iron Pipes conforming to IS : 8329
18.72.1 100 mm dia Ductile Iron Class K-7 pipes Mtrs 145.00 1114.10 161544.5
18.68 Providing and laying D.I. specials of class K-12 suitable for push-on
jointing as per IS : 9523
18.68.1 Upto 600mm diameter Quintal 6.00 17094.25 102565.5
18.70 Providing push-on-joints to Centrifugally (Spun) Cast Iron
Pipes or Ductile Iron Pipes including testing of joints and the
cost of rubber gasket :
Providing and fixing C.I. double acting air valve of approved quality
18.59 with bolts, nuts, rubber insertions etc. complete (The tail pieces,
tapers etc if required will be paid separately):
18.41 Providing & fitting sand of grading zone V or coarser grade
alround the GI pipes in external work:
18.41.9 100mm diameter pipe Mtr 145.00 275.60 39962
18.17 Providing and fixing gun metal gate valve with CI wheel of
approved quality (screwed end).
18.17.1 25mm nominal bore Each 3.00 497.15 1491.45
18.17.2 32mm nominal bore Each 6.00 581.25 3487.5
18.17.3 40mm nominal bore Each 17.00 678.40 11532.8
18.17.4 50mm nominal bore Each 8.00 869.20 6953.6
18.17.5 65mm nominal bore Each 6.00 1488.10 8928.6
18.17.6 80mm nominal bore Each 3.00 2217.90 6653.7
14 Providing, installation, testing and commissioning of
non-return valve of following sizes confirming to IS:
5312 complete with rubber gasket, GI bolts, nuts,
washers etc.as required
Providing and fixing C.I. Sluice valves (with cap) complete
with bolts, nuts, rubber insertions etc. ( the tail pieces if
required will be paid separately).
18.31.1 100 mm diameter
18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick
work incement mortar 1:4 (1 cement :4 coarse sand) for stop
cock, with C. I.surface box 100x100 x75 mm (inside) with
hinged cover fixed in cementconcrete slab 1:2:4 mix (1 cement
: 2 coarse sand : 4 graded stoneaggregate 20 mm nominal
size), i/c necessary excavation, foundationconcrete 1:5:10 ( 1
cement : 5 fine sand : 10 graded stone aggregate40mm
nominal size ) and inside plastering with cement mortar 1:3
(1cement : 3 coarse sand) 12mm thick, finished with a floating
coat ofneat cement complete as per standard design :
18.32.1 With common burnt clay F.P.S.(non modular) bricks of class Each 3.00 1582.45 4747.35
designation 7.5
18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick
work in cement mortar 1:4 (1 cement : 4 coarse sand) for
sluice valve,with C.I. surface box 100mm top diameter, 160
mm bottom diameter and 180 mm deep ( inside) with chained
lid and RCC top slab 1:2:4
mix (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size ) , i/c necessary excavation, foundation
concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone
aggregate 40 mm nominal size) and inside plastering with
cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,
finished with a floating coat of neat cement complete as per
standard design :
18.33.1 With common burnt clay F.P.S.(non modular) bricks of class Each 7.00 9288.40 65018.8
designation 7.5
18.34 Constructing masonry Chamber 90x90x100 cm inside, in brick
work in cement mortar 1:4 (1 cement : 4 coarse sand) for
sluice valve,with C.I. surface box 100 mm top diameter, 160
mm bottom diameter and 180 mm deep (inside) with chained
lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm
nominal size ), i/c necessary excavation, foundation concrete
1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40
mm nominal size ) and inside plastering with cement mortar
1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a
floating coat of neat cement
complete as per standard design :
18.34.1 With common burnt clay F.P.S.(non modular) bricks of class Each 3.00 16134.15 48402.45
designation 7.5
19.1 Providing, laying and jointing glazed stoneware pipes class SP-
1 with stiff mixture of cement mortar in the proportion of 1:1 (1
cement : 1 fine sand) including testing of joints etc. complete :
19.2 Providing and laying cement concrete 1:5:10 (1 cement: 5
coarse sand : 10 graded stone aggregate 40mm nominal size)
alround SW/RCC NP2 pipes including bed concrete as per
standard design.
19.2.1 100 mm dia SW/RCC NP2 pipe Mtr 50.00 817.00 40850
19.6 Providing and laying non-pressure NP2 class (light duty)
R.C.C. pipes with collars jointed with stiff mixture of cement
mortar in the proportion of 1:2 (1 cement : 2 fine sand)
including testing of joints etc. complete :
19.7 Constructing brick masonary manhole in cement mortar 1:4 (1
cement: 4 coarse sand) RCC top slab with 1:2:4 mix (1
cement: 2 coarse sand: 4 graded stone aggregate 20 mm
nominal size), fondation concrete 1:4:8 (1 cement: 4 coarse
sand: 8 graded stone aggregate 40 mm nominal size) inside
plastering 12 mm thick with cement mortar 1:3 (1 cement: 3
coarse sand) finished with floating coat of neat cement and
making channels in cement concrete 1:2:4 ( 1 cement: 2
coarse sand: 4 graded stone aggregated 20 mm nominal size)
finished with a floating coat of neat cement complete as per
standard design.
19.7.1 Inside size 90 x 80 cm and45cm deep including CI cover with
frame (light duty ) 455 x 610 mm internal dimensions total
weight of cover and frame to be not less than 38 kg) (weight of
the cover 23 kg and weight of frame 15 kg).
19.7.1.1 With common burnt clay F.P.S ( non modular ) bricks of class Each 5.00 10905.05 54525.25
designation 7.5
19.7.2 Inside size 120x90 cm and 90 cm deep including C.I. cover
with frame (medium duty) 500 mm internal diameter, total
weight of cover and frame to be not less than 116 kg (weight of
cover 58 kg and weight of frame 58 kg) :
19.7.2.1 With common burnt clay F.P.S ( non modular ) bricks of class Each 11.00 22939.65 252336.15
designation 7.5
19.8 Extra for depth for manholes :
19.8.1 Size 90x80 cm
19.8.1.1 With common burnt clay F.P.S. (non modular) Each 1.00 7503.00 7503
bricks of class designation 7.5
19.8.2 Size 120x90 cm
With common burnt clay F.P.S. (non modular) meter 5.50 8994.60 49470.3
bricks of class designation 7.5
19.9 Constructing brick masonry circular type manhole 0.91 m
internal dia at bottom and 0.56m dia at top in cement mortar
1:4 (1 cement: 4 coarse sand), inside cement plaster 12 mm
thick with cementmortar 1:3 (1 cement : 3 coarse sand)
finished with a floating coatof neat cement, foundation
concrete 1:3:6 mix (1 cement : 3 coarse
sand : 6 graded stone aggregate 40 mm nominal size), and
making necessary channel in cement concrete 1:2:4 (1 cement
: 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) finished with a floating coat of neat cement, all complete
as per standard design :
19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty,
HD-20 grade designation) 560 mm internal diameter
to I.S. 12592, total weight of cover and frame to be
not less than 182 kg., fixed in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) including centering, shuttering all complete.
(Excavation, foot rests and 12mm thick cement plaster at the
external surface shall be paid for separately) :
19.9.1.1 With common burnt clay F.P.S. (non modular) Each 49.00 11038.10 540866.9
bricks of class designation 7.5
19.10 Extra depth for circular type manhole 0.91m internal dia (at
bottom) beyond 0.91 m to 1.67 m
19.10.1.1 With common burnt clay F.P.S. (non modular) bricks of Each 2.00 6448.40 12896.8
class designation 7.5
19.11 Constructing brick masonry circular manhole 1.22 m internal
dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1
coarse sand) inside cement plaster 12 mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished with a floating
coat of neat cement foundation concrete 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 40 mm nominal size)
and making necessary channel in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) finished with a floating coat of neat cement, all
complete as per standard design
19.11.1 1.68 m deep with SFRC Cover and frame (heavy duty HD-
20 grade designation) 560 mm internal diameter conforming
to I.S. 12592, total weight of cover and frame to be not
less than 182 kg. fixed in cement concrete 1:2:4 (1 cement
: 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) including centering, shuttering all complete.
(Excavation, foot rests and 12 mm thick cement plaster at the
external surface shall be paid for separately) :
19.11.1.1 With common burnt clay F.P.S. (non modular) Each 32.00 21235.65 679540.8
bricks of class designation 7.5
19.12 Extra depth for circular type manhole 1.22 m internal dia (at
aoc.pdf