Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC 40 VISHNU VIHAR KHERAI SHAMSHABAD ROAD KHERAI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹36.9 L+₹11.5 L (45.4%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
25 Feb 2023, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
PROVN OF RIFLE RACK , EMERGENCY ALARM HOOTER SYSTEM IN DUTY ARMOUR REST ROOM AND PROVN OF VOLTAGE STABILISER FOR IPPS AND PROVN OF FLAME PROOF LED LIGHT AT CERTAIN SQN HANGER TESTING SITE AND PROVN OF BOLLARD LIGHT AT DOMESTIC AREA AND ALLIED WORK
2022_MES_572097_2
8875/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
As per tender docuemtns
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹47,000
Yes
6 Mar 2023
2 Feb 2023
27 Feb 2023
2 Feb 2023
25 Feb 2023
10 Feb 2023
Amount
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in hard /dense soil complete all as specified and as directed
Sand cushioning and cover (using local tibba sand), 80 mm thick before laying of cable and 150 mm thick after the cable is laid, complete all as specified and as directed by Engineer-in-Charge. (Note : 1. Approved local tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning and cover).
Jodhpur stone rough dressed slab, 40 cm to 50 cm thick, 25 cm to 35 cm wide of 80 cm long dry abuttting each other for protection to under groung cable , complete all as specified and as directed .
Removing surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed .
Returning, filling in approved soft/loose soil including spreading, leveling, watering and well ramming in layers each n.exc 25cm complete all as specified and as directed .
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 10 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc. complete all as specified. Notes :- (i) Sand cushioning, cable protection, GI pipe and excavation & earth work shall be measured & paid for separately (ii) Road cutting/ floor cutting/ cutting holes etc in walls required for laying/ fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 16 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc. complete all as specified. Notes :- (i) Sand cushioning, cable protection, GI pipe and excavation & earth work shall be measured & paid for separately (ii) Road cutting/ floor cutting/ cutting holes etc in walls required for laying/ fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 35 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc. complete all as specified. Notes :- (i) Sand cushioning, cable protection, GI pipe and excavation & earth work shall be measured & paid for separately (ii) Road cutting/ floor cutting/ cutting holes etc in walls required for laying/ fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 50 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc. complete all as specified. Notes :- (i) Sand cushioning, cable protection, GI pipe and excavation & earth work shall be measured & paid for separately (ii) Road cutting/ floor cutting/ cutting holes etc in walls required for laying/ fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
40 mm bore GI tube, light grade galvanised with clamp of 25 x3 flat iron for protection of cable , with all fitting lead in trenches /under road / with wall /in wall /pole /under floor where required complete all as specified and as directed
Drilling (Horizontally) of holes under road 110 mm dia , pavement , hard standing by trench less technology ( manually ) with out disturbing the top surface of road (maxium 10 mtr wide) for laying of cable/ GI pipes complete all as specified and as directed .
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to and including galvanized earth lead wire 4mm dia upto 7.5 metre by means of GI nuts, bolt, check nuts, washers thimbles, etc as shown in electrical plate No 03 SSR Part I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exc 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 15mm bore meter long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25mm x 3mm, bolts, nuts and washers 75mm thick RCC cover 1:2:4 type B-1 shall be provided on CI frame etc complete all as specified. Note - PCC chamber shall be constructed at least 1.5m away from the earth electrode. The pipe for watering shall be provided in slanting manner
Supply and fixing flush mounting factory made SPN DB 8 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 200 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and as directed .
MCB, Single Pole, 5 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles including complete, all as specified & directed.
MCB, SPN, 40 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
Single pole and neutral enclosure with a two pin and earth plug and socket , 20 Amps 230 Volts with & including one MCB SP ‘C’ Curve 10 kA 20 Amps complete all as specified and directed.
Sub main wiring with two run of 1.5 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volts grade conforming to IS 694 including 1.50 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour drawn through in 20 mm dia surface/recessed non etallic PVC rigid conduit complete all as specified. Note : Two run of 1.50 sqmm cable and one run of 1.50 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
MME automatic gong bell 12 inches industrial type complete all as specified and directed.
Metal flush mounting box 1/2 module complete all as specified and directed.
White colour plate with frame for modular swith of 1/2 module complete all as specified and directed.
Mdular Bell push flush type 6 amps 1 module ,single pole 240 V , ISI marked complete all as specified and as directed
S&F junction box made out of polycarbonate with IP55/IP protection of size not less 200 x 160x 98 mm 5 way having terminals for termination of cable with necessary nuts and bolt including 02 nos polycarbonate cable gland 01 Nos DIN rail mounting of MCB and 01 No , MCB SP 10 KA , 6 Amp in and including fixing clamp of FI 25 x 3 mm with ncessary nuts and bolt complete all as specified and as directed
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-290 Gde E-165 including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and also including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces, supply and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. Notes :- (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge. (ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only.
Excavation in post holes(or similar holes) each n. exc 0.5 cum getting out ,returning filling in and ramming earth or broken rubble mixed with around in layer n.exc.25 cm thick, watering and removing surplus soil to a distance n. exc 50 m and making good surface all complete all as specified and as directed .
Plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in lintel, cill, bed block coping ,bed plate, bond stone etc including weathering slightly rounded or chamfered angles and throating complete all as specified and as directed .
Supply, installation, commissioning and testing of servo voltage stabilizer (Conforming to BIS-9815:1994) for automatic operation , three phase, naturally oil cooled, copper wound, metalic body duly powder coated with lifting hooks 02 Nos, digital display type relay free smooth and silent operation outdoor type of capacity 50 KVA complete all as specified and directed in and including following specifications :- (i) Applicable standard - IS 9815:1994 (ii) Input voltage range 300-480 volts 3 phase, 50Hz 4 wire & earth (iii) Output voltage - 415(Plus/Minus)-01% VAC accuracy, 3 phase, 50 Hz 4 wire & earth (iv) Line regulation - Line to load regulation 1 % (v) Type of Load- Three Phase unbalanced type (vi) No distribution in wave form (vii) Correction range-8V/Sec for single phase and 13V/Sec for phase to phase (viii) Efficiency- Above 95% (ix) Response time not to be exceed 20 mili second (x) Noise level - <55 db at a distance of 1 mtr (xi) Monitoring and electronic circuit- Microprocessor controller and DSP base electronic card with inbuilt LCD display, input L/L and L/N voltage monitoring, output L/L and L/N voltage monitoring, Load current phase wise monitoring, input line indication (xii) Protection - Input 3 pole MCCB with shunt release coil for high/low voltage protection and overload and short circuit protection, output 4 pole change over switch for by pass, 10 sec on time delay, RF filter, spike booster reverse phase protection, single phasing protection, earth protection & netrual protection curcuit, spike & surge protection Note : 1. Amount for 1st filling of transformer oil upto level is deemed to be included in unit quoted rates Note : 2. Necessary addition/altn if required at site for mounting/Placement of stabilizer is deemed to be included in unit quoted rates, Cost of foundation/plateform with necessary earth work for mounting of stabilizer as per manufacturer's recommendations is deemed to be included in unit quoted rates
Supply, installation, commissioning and testing of servo voltage stabilizer (Conforming to BIS-9815:1994) for automatic operation , three phase, naturally oil cooled, copper wound, metalic body duly powder coated with lifting hooks 02 Nos, digital display type relay free smooth and silent operation outdoor type of capacity 15 KVA complete all as specified and directed in and including following specifications :-(i) Applicable standard - IS 9815:1994 (ii) Input voltage range 300-480 volts 3 phase, 50Hz 4 wire & earth (iii) Output voltage - 415(Plus/Minus)-01% VAC accuracy, 3 phase, 50 Hz 4 wire & earth (iv) Line regulation - Line to load regulation 1 % (v) Type of Load- Three Phase unbalanced type (vi) No distribution in wave form (vii) Correction range-8V/Sec for single phase and 13V/Sec for phase to phase (viii) Efficiency- Above 95% (ix) Response time not to be exceed 20 mili second (x) Noise level - <55 db at a distance of 1 mtr (xi) Monitoring and electronic circuit- Microprocessor controller and DSP base electronic card with inbuilt LCD display, input L/L and L/N voltage monitoring, output L/L and L/N voltage monitoring, Load current phase wise monitoring, input line indication (xii) Protection - Input 3 pole MCCB with shunt release coil for high/low voltage protection and overload and short circuit protection, output 4 pole change over switch for by pass, 10 sec on time delay, RF filter, spike booster reverse phase protection, single phasing protection, earth protection & netrual protection curcuit, spike & surge protection Note : 1. Amount for 1st filling of transformer oil upto level is deemed to be included in unit quoted rates Note : 2. Necessary addition/altn if required at site for mounting/Placement of stabilizer is deemed to be included in unit quoted rates, Cost of foundation/plateform with necessary earth work for mounting of stabilizer as per manufacturer's recommendations is deemed to be included in unit quoted rates
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Earth continuity conductor 32 x 6 mm GI strip fixed to wallor resses or chasses or burred or drawn in conduit pipe / 40 mm light grade complete all as specified and as directed .
Supply and fixing LED flood lights not less than 120 watts, nominal voltage 240 volts, 50 Hz, high efficiency long life LED module with SMD LED package mounted on MCPCB, lumen efficacy of LED shall not be less than 120 lumen/W, Colour temp (CCT) -5700K and viewing angle of 120 degree to ensure better uniformity, epoxy powder coated pressure die cast aluminium housing elegantly designed heat sink for efficient thermal management, high quality toughened glass IK 07 fixed to housing, having electronic driver, integral, isolated electronic driver with lower THD, output open/short circuit protection, over voltage protection, surge voltage protection with external SPD not less than 10 KV and other safety test as per IS 15885 Part-2/Sec 13, having adjustable MS cradle of thickness 5mm provided complete all as specified and directed,
Supply, fixing, connecting and testing LED bollard light decorative type with reflector not less than 10 watt , IP65, LED Bollard with soft 360 deg light distribution having fixing arrangements at bottom with necessary nuts, bolts, washers complete all as specified and directed,
Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size not less than 200 x 160 x 98 mm , 5 way having terminals for termination of cable with necessary nuts and bolts including -02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete all as specified and directed .
Supply, fixing and connecting elastomer insulated, flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size 1.5sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed
20mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete all as specified and directed.
Surface point wiring with multi stranded copper conductor cable, 1100 volts grade (ISI marked), FRLS, PVC insulated and unsheathed of size 1.5 sqmm, single core in and including new non metallic rigid PVC conduit of 20 mm dia, medium duty, ISI marked, including conduit fittings such as tees, bends etc terminating in old existing M.S sunken boxes covered with and including 3 mm thick bakelite laminated sheet top cover of approved make for mounting switches, sockets, regulators etc,with and including continuous 1.5 sqmm PVC insulated unsheathed single core copper conductor cable as earth continuity conductor connected to common earth and earth dolly, for one light point/fan point/ call bell point controlled by one, one way switch complete all as specified and as directed by Engineer-in-Charge.( Note : Unit rate quoted against this item shall be deemed to include for cutting chases for conduits and sinking for boxes and making good to existing specification of adjoining wall/floors etc.)
Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed
Flame proof, CIMFR certified LED lights not less than 60 watt, Flame Proof light in die cast aluminium housing with heat resistant toughened glass complete recommended for explosive storage complete with all fixing arrangments at site and as specified.
M/S BHATI TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .