Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.7 L+₹89,495 (2.25%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹41.6 L+₹1.8 L (4.42%)Rejected-Finance NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance BEING L3 |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
9 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UDHAMPUR
GE AF UDHAMPUR
PROVN OF CERTAIN B/R AND E/M SERVICES AT AF STN UDHMPUR
2023_MES_573316_1
GE/AFU-62/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF Udhampur
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹86,000
Yes
20 Feb 2023
6 Jan 2023
11 Feb 2023
6 Jan 2023
9 Feb 2023
21 Jan 2023
6 Jan 2023 - 13 Jan 2023
Amount
SCH A PART-I (B/R WORKS)
Excavating in post holes (or similar holes) each n exc 0.5 cum getting out ,returning filling in and ramming earth or broken rubble mixed with earth around ,in layers not exceeding 25 cm, watering,and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
Surface excavation n.exec 30cm deep and averaging 15cm deep and getting out in hard and dense soil complete all as specified and directed
M&L for Hardcore of broken stone of gauge n exc 63mm deposited, spreaded & levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
M&L PCC 1:5:10 type E-2 (40mm graded aggregate) in foundation, sub base, filling and mass concrete complete all as speified and directed.
M&L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation filling and mass concreting complete all as specified and directed.
S&F rolled mild steel in framed work (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410-W (Gde-E-250) Quality-B complete all as specified and directed.
S & F steel work in tubular post medium weight/angle, joist,T sec etc fixed independently without connecting plates etc (cut tobordinary lengths i.e. with in 20 mm of the length indicated) complete all as specified and directed.
M& L steel workin tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St -240 complete all as specified and directed.
S & F MS screw bolts 11 to 15 mm dia of neck (machine made) with hexagnal or square heads at one end and scewed the other, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm and and not exc 10 cm long complete all as specified and directed.
S&F 0.80 mm thick mild steel plain black sheet in wall cladding, steel gates and similar works, cut to size, holes punched including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up, mitred angles etc as required, complete all as specified and directed.
M & L Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description over 10cm width or girth, applying two coats of synthetic enamel paint over one coat of red oxide complete all as specified and directed.
M&L for removing excavated material exc 250m but n.exc 500m and depositing where directed at a level n exc 1.5m above the starting point in soils.
Returning filling in incl spreading, levelling watering and well ramming in layers in layers 25 cm thick complete all as specified and directed.
M & L for 50 mm PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in floors finished even & smooth without using extra cement complete all as specified and directed.
M & L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for emedding MS pipes as in foundation filling and mass concrete complete all as specified and directed.
Cutting holes in brick walls built in Cement mortar for exceeding half brick wall but n.exc one brick wall for inserting holdfasts or similar works making good dismantling portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 a complete all as specified and directed.
Cutting chases, pinning in , making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing steps cills shelves lintels or similar worksetc and making good in cement concrete 1:2:4 type B-1 complete all as specified and as directed
M & L for PCC 75 mm thick PCC 1:4:8 as in sub base of floors complete all as specified and directed.
M & L for 40 mm thick PCC 1:2:4 as in floors finished even and smooth w/out using extra cement complete all as specified and directed
M & L for welded steel fabric complete to wooden or steel memebers complete all as specified and directed.
Demolition Brickwork or stone/ boulder masonry, laid dry complete all as specified and as directed.
Demolition of Cement Concrete(Unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and directed.
M&L for cement concrete type C2 1:3:6 (40mm graded aggregate) in walls or retaining walls, any thickness, size or shape including pillasters, buttresses, columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm long but n exc 30cm long complete all as specified and directed.
M&L for Mild TMT steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips c complete all as specified and directed.
All as per above item No 1.28 but 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L Mild steel plates 410-W (Gde-e-250) quality -A, plain or chequered, 5 mm thick or over in thickness in available sizes square cut or notched (ordinary or counter sunk) forming holes without any attachment complete all as specified and directed.
M&L Reinforced cement concrete (nominal mix) type B-1 (20mm graded stone aggregates) in columns, pillars, piers, posts and struts complete all as specified and directed.
M & L cement concrete in lintels upto 1.5 m clear span type B1 1:2:4, cills,steps, seismic and other bands, plinth courses,string courses, parapetss and railings upto 60 cm in height, copings, kneelers, apex stones, bed platers, kerbs , water troughs and the like incl werathering, slightly rounded or chamfered angles and trhroating etc complete all as specified and directed.
Cutting openings through brick walls for doors, windows and other openings or enlarging existing openings, converting window into door openings etc or cutting out defective brick work for under-pinning incl providing, fixing and removing shoring, cleaning and stacking bricks, remoiving surplus serviceable bricks , hard core etc to store amnd rubbish not exc 50 m complete all as specified and directed.
Forming jambs etc to openings ( to above item) incl cutting, toothing and properly bonding in old work in cement mortar 1:4 also facing, jointing and pointing to match existing work complete all as specified and directed.
M&L for preparation of newely plastered of surface wall and applying two coat of cement base paint over a coat of Alkali resistant primer complete all as specified and directed
M&L for preparation of newely plastered of surface wall and applying two coat of Oil Bond Distemper over a coat of primer complete all as specified and directed
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete incl one shop coat of zinc chromate primer paint incl preparation of surfaces at contractor's workshop before fabrication, complete all as specified and directed.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
S&F Butt hinges of size 125mm, heavy weight, cold rolled mild steel, and fixed, complete all as specified and directed.
S&F Mild steel sliding door bolts 200mm, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and directed.
S&F Mild steel barrel tower bolts 200mm in length, stove enamelled black,with bright bolt, complete all as specified and directed.
S&F for large and heavy gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafter; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165. complete all as specified and directed.
S&F 1.60 mm thick mild steel plain black sheet in wall cladding, steel gates and similar works, cut to size, holes punched including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up, mitred angles etc as required, complete all as specified and directed.
S&F collapsible steel gate, top hung,consisting of channel pickets,pivoted flat bars,top and bottom runners,brass handles etc,as specified, erected in postion and securing runners with hold fasts and brackets complete all as specified and directed .
M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors shutter with door frame with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket, etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,complete all as specified and directed.
S&F anodized, powder coated aluminium doors shutters, (thickness of powder coating not less than 50 micron) aluminium section weighing exc 0.55 Kg/m including necessary joining cleats, glazing clips rubber neoprene packing, handle 2 Nos in each door, fixed with floor hinges/ spring (measured separately), 4 lever brass mortice lock vertical type (1 No ), anodised aluminium snap beading screws etc complete all as specified and directed.
S&F 5.5mm thick sheet tinted sheet glass fixed to doors and windows complete all as specified and directed.
S&F 100 mm size of Butt hinges, extruded powder coated aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed.
S&F 150mm size of Extruded powder coated aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
S&F 150 mm size of powder coated aluminium, barrel tower bolts of extruded section and fixed, complete all as specified and directed.
S&F for door closer hydraulically regulated, aluminium (extruded section body), designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg, complete all as specified and directed.
S&F mild steel 04 - levers Mortice lock, vertical type, size 100 mm, complete all as specified and directed.
S&F rubber beading of required size for fixing of glass/ACP sheets etc as in aluminium doors/windows/partitions complete all as specified and directed.
S&F Alum snap beading powder coated of required shape and size for fixing of glass/ACP sheets etc as in aluminium doors/windows/partitions complete all as specified and directed.
S&F Aluminium composite panel (ACP sheet) 3-5 mm thick both side laminated fixed in bottom side of partition complete all as specified and directed.
S&F drilling hole in glass of thickness exc 4 mm but n exc 8 mm thick, any type,any dia of hole all as specified and directed.
M&L Veneered decorative plywood of 9 mm thickness, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work complete all as specified and directed.
M&L for applying three coats of white wash on walls incl preparation of newly plastered or unplastered surfaces complete all as specified and directed.
M&L Mild steel work as in Stairs (Framed) incl stringers, treades,, landing, balusters, hand rail etc, in cudding cleats, brakcets etc complete all as specified and directed.
S&F Plates(Plain or Chequered) channels,square cut or notched(ordinary and counter sunk) with riveted ,bolted or welded attatchment in ladder steps work conforming to Fe 410-W (Gde-E-250 quality-A) complete all as spfd
S&F18/19 mm thick termite proof,chemically well pressed,block boards/plywood,grade 1 quality,exterior grade,commercial type,fixed with screws to timber frame work,including 1mm thick PVC moulding all around including edging,complete all as specified and directed.
S&F 0.9 mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
S&F 100 mm Brass handles, cast type, polished bright complete all as specified.
S&F 30mm (width of flaps) Continous (Piano) hinges of mild steel,bright finish complete,all as specified .
S & Fanodised aluminium snap grid frame work for false ceiling size 605 x 605 mm complete all as specified and directed.
S & F hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs/ truss by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S & F 4 mm Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling flat or sloping complete all as specified and directed.
M & L 2 coats of synthetic enamel paint on wooden surfaces exc 10 cm width or girth over a coat of pink primer incl preparation of surfaces complete all as specified and directed.
S & F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC Frame complete all as specified and directed.
SCH A PART-II (E/M WORKS)
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 4.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Supply and fixing of Sheet metal enclosures with socket plug top and MCBs single pole and netural enclosure with a two pin and earth plug and socket complete one single pole 32 Amps Flush mounted complete all as specified and directed.
M&L for Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC conduits, with new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified.
S & F Switch piano flush type 6 AMP, SP one way complete all as speciifed and as directed
Supply and fixing LED lights fitting 1x20W LED 6500K, 220V,AC LED lighting fixture with extruded polycarbonate environmental friendly energy box type four feet with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
S&F Recess mounting type LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 34 watt to 36 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, surge protection device min 2 KV, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, THD less than 10%, life 50,000 burning hours minimum IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified. (Make Havells/Bajaj/CG or Equivalent.)
Supply and fixing of steel body exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete including making suitable size hole in wall and making good surface all as specified and as directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply and fixing of wall mounted fan 400MM motor ,mounting Accossires kit blade ,guard set guard ring 1350RPM complete all as specified and as directed
Supply and fixing of Pedistal fan 400MM motor fan blade ,guard set guard ring 1180 RPM complete all as specified and as directed
M&L for Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete including flexible steel conduit for connection at switch, DB etc all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
S& F 15 Amps switch socket combinatin complete all as specifeid and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid metallic ERW Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT/SOCKET CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete including flexible steel conduit for connection at switch DB etc all as specified and as directed.
Supply and fixing of flame proof rotary type switch with termination box in LM6 16A single pole 250 V Complete all as specified and as direcetd.
Supply and fixing LED light fitting 2X40Watt flame proof street light, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fixing of Flame proof Exaust fan flame proof , CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant driver, holders, connector etc. Complete louver and cutting of wall for suitable fixing of flame proof E/Fan including civ work plasetr etc with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 4 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed pvc conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 4 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified.
Suply and fixing of Switch socket combination 5 in 1, 16 Amp flush type universal type, conforming to IS-3854 complete all as specified and as directed.
Supply and fixing of ceiling rose 3phase /PVC/polycarbonate,isolated body complete all as specifid and as directed.
Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated, 0.8 Bar pressure rating, SS tank complete with all accessories such as safety valve, thermostate, NRV, connection piece Hot and cold ss 304 pipe with fastiners etc complete all as specifeid and as directd
Cutting of existing steel tubing pipeany size for alternations or addition and necessary done in position without taking down cmoplete making good condition complete all as specified and as directed
S&F of tubes 15 MM 'medium grade', galvanised, with all fitting (such as tee, bend, elbow, union etc) laid in walls and making good connection complete all as specified & directed .
Supply & fixing gunmetal gate valve, brass ball valve, with iron wheel head screwed both ends for iron pipe and fixed 15 mm dia complete all as sepecified and as directed .
M&L Bib Taps 15 mm cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through PVC conduit ISI Marked and connected to main tower/ shelter/buliding up to 60 mtr height cuitable size clips ,streep etc and making good disturbed surface and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 4.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Supply and fixing of Integral LED aviation light luminaire in yellow die-cast aluminium alloy housing with red coloured polycarbonate dome of cat part No BGAV 302 LED of make Bajaj or equivalent C&S/CG/Philips including necessary electric connection with suitable size of PVC copper cable as per manufacture's requirement up to tower/building height 60 mtr , complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED flood light 100watt 230 V AC, 100 lm/watt, CRI 80, pf>0.90 outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all including clamp etc & directed by engineer-in-charge.
Supply and install HOT and COLD Type invetor split AC Copper wound wall mounted indoor/outdoor complete with cordless remote control unit of capicity of 1.5Ton 3 Star ,cooling capicity 5200 watt heating capicity 5600 Watt,R-32 , refrigrant,low indoor noice less than 48 dB, dust filter Air Purifier stablizer free operation, Cu connecting pipe length upto 5 Mtr/ connecting cable upto 5 mtr all including outdoor unit mounting bracket making holes in wall and making good complete all as specified and as directed.
M&L for MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 8 way SPN with 200 Amp rated bus bar 203 volt AC supply complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP32 Amps of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning of capacity of 32 Amps complete all as specified and as directed.
Supply and fixing of refrigerator, electric driven (single phase), capacity 360 Litres Intelligent invertor Compressor Double door 5 star rating, bilt in stablizer ,top mount freezer compatmant features ice twister assambly complete all as specified and as directed. Make - Voltas, Samsung, Blue star or its equivalent as specified make.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140 V to 280 VAC with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140 V to 280 VAC with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with capacity 12 A, ABC body/4 Amp ABS body and of capacity 01 KVA. Make :- V guard or equivalent as approved by GE.
Supply and fix of Deep freezer 230 Volt 50HZ capacity 400 Litres with high density PUH insulation, double door, heavy duty caster wheel, hard top, anti corrosive pre coated body, convertible cooling mode & freeze mode (<-18 degree C) complete all as specified and as directed by Engineer -in- charge. Make - Voltas, Samsung, Blue star or its equivalent as specified make.
M&L for Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5. sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through PVC surface conduit and connected to main board and making good disturbed surface complete clip screw gutty etc all as specified and as directed. Note: Two runs each of one RM of 2.5 sqmm main cable and one RM of 2.5. sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L for Sheet metal enclosures for DBs SPN 2 way (when MCBs to be used) flush mounted including necessary fitting to the SPN complete all as specified and directed by Engr-in-Charge.
Supply and fixing of MCCB Enclosure for Capacity of 100 Amps MCCB 4 pole including fixing the enclosure on the wall with the help of fastner/nut/bolts/washer and cutting chasing to wall, making good the disturbed surfaces to match with the existing specifications, complete all as specified and as directed.Make : Indoasian cat part No 811985 or equivalent Havells/Siemens/Legrand as approved by GE.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, thermal magnetic load, ICS 100 of ICU, 0.8 ln to 1 ln, 125 Amps with breaking capacity 16 KA as per IEC 60947-2 including all accessories all as specified and directed by Engr-in-Charge.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, thermal magnetic load, ICS 100 of ICU, 0.8 ln to 1 ln, 160 Amps with breaking capacity 36 KA as per IEC 60947-2 including all accessories all as specified and directed by Engr-in-Charge.
M&L for MCCB three pole 415 Volts 50 Hz 160 Amps rating with rupturing capacity not less than 16 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc complete all as specified and as directed.
S&F GI tube, 'medium grade' galvanised with all fitting laid in ground to junction box for electric cable of 25 mm dia complete all as specifed and directed by Engr-in-Charge.
M & L for PCC 1:4:8 type D2 (Using 40 mm graded stone aggregate) in foundations, filling and mass concret, complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (Using 12.50 mm graded stone aggregate) as in copings etc complete all as specified and directed by Engr-in-Charge
Mild steel powder coated perforated sheets of size 30 cm width as cable duct trays and similar work cut to size holes punched including round headed screqs clout nails or rixet revets and fixed to wood or steel framing with olain 40 mm lap joints with revetted seams including bending or turning up mitered angles etc as required of 3.15 mm thick sheet complete as specified and directed.
Perforated angle of size 40x40x4 mm powder coated for holding cable trays with complete nuts and bolts and washers to match with the colour with cable tray complete all as specifed and directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 10Sqmm 4.0 core laid on walls/floors/trenches or in air with saddles and gutties complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 25 Sqmm 3.5 core laid on walls/floors/trenches or in air with saddles and gutties complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 50 Sqmm 3.5 core laid on walls/floors/trenches or in air with saddles and gutties complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 95 Sqmm 3.5 core laid on walls/floors/trenches or in air with saddles and gutties complete all as specified and directed.
M & L for Weather proof outdoor bus bar chamber, made out of 2.0 mm thick CRCA sheet comprising 4 Nos aluminium strips each of 200 Amps, 60 cm long duly insulated mounted on insulators including one no incoming MCCB 100 amps 25 KA 415 volts and one out going MCCB 63 Amp, 16 KA 415 volts complete with all accessories, 4 No's mounting legs made out of 25 mm x 25 mm x 6mm angle iron grouted in PCC block of size 30 cm x30cm x 90 cm (30 CM depth below ground level and 60 cm above ground level) in cement concrete 1:3:6, type C-2 (Using 40 mm grade crushed stone aggregate), and connections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work returning filling and removal of surplus soils complete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick as earth electrode burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using GI strip 32x6 mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers incl jointing of earth electrode and earth wire by means of welding,all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil , removing surplus excavated material all as required at site and specified in EP No 5 of SSR 2009 part- I directedby Engineer-in-charge
M&L for 80 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed.
Supply and fixing off load change over switch 514 Volt, 50 HZ in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and directed by Engr-in-Charge.
Supply and fixing of MCB SPN 32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' charactersticks and current carrying capacity in the MCB complete with testing and commissioning as specified and as directed.
Shifting of existing AC with complete wiring and switches for operator and management PC cabin and UPS equipment cabin complete all as specifed and directed
Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion.
M&L of LT panel in door type cubical floor mounted type made out 2.0mm thick CRCA Sheet duly powder coated complete bus bar 400 Amps rating made of Aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 Wire 415 volts 50HZ Power suply system suitable for and including the following (a) MCCB 415 Volts 200Amps 4 Pole with Reputing CAP for over load short circuit protation : 01 Nos incoming (b) MCCB 415 Volts 63Amps 4 Pole with Reputing fixed type based for over load short circuit protation : 04 Nos OUTGOING (c) All acessories prewired with suitable size copper conductor cable/strip and suitable foundation as per manufactors remcomendation (d) Indicator set RYB 01 Set 3 pcs Led type Note : including site clearance /earthwork with pcc sub base and brickwork of platform with external platform complete all as specified and as directed .
M&L VTPN Vertical three phase distribution board, VTPN, 4 way 440 volts having IP-54 isolated busbar assembly IK 09 Mechnical impact strength door earthing protection, double door with provision for fixing of MCCBs as incomer up to 200 Amps and MCBs as outgoing complete all as specified and as directed
Suppy and fixing of GI tube light grade of bore 80 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building height complete all as specified and directed by Engr in charge
Supply and fixing of Earth continuity conductor GI strip 4mm laid fixed to wall by Hole fastner size 25 mm to 45mm along with Procelain /DMC insulator up to 15 mtr building height complete all as specified and as directed by Engr-in-Charge
Supply and fixing of Earth continuity conductor GI strip 32x6mm laid fixed to wall by Hole fastner size 25 mm to 45mm along with Procelain /DMC insulator up to 15 mtr building height complete all as specified and as directed by Engr-in-Charge
Maintaince free safe earthing syatem(set of three electrode to be used as grid for equipment earthing ) each pit complte with 01 Number UL 467 APPROVED/CPRI tested copper bonded (Copper cladded earth rod with 250 microns of copper cladding) earth rod 17.2 m dia. 3000 mm long electrode buried in ground to bore holes 120 mm dia. verically to a depth not less than 3.5 mtr deep below ground level with top edge of earth electrode at a depth not less than 500 mm below normal ground level, provision of copper bus bar of size 200mm x 25mmx 6mm for inter connection with copper earth lead strip 32mm x 3mm and further connected to test point terminal block all as directed. Each earth pit shall include minimum 50 Kg (two bags of 25 Kg each) NABL lab certified back fill compund for filling bore holes with mother soil mixed in 1:3 ratio (one part of back fill compund and three parts of mother soil), so as to achieve earth resistance below 1 Ohm including excavation of polypit chamber with polyplastic pit cover (cost f polypit chamber with polyplastic pit cover shall be deemed to be included in the rate quoted) complete all as specified and as directed by Engr-in-Charge Note :- Earth pit shall be atleast 3 mtr from other earth pit.
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out, , complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge
Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed by Engineer-in-Charge
Dry sand cushioning to under ground cable all as per clause 19.75 of SSR Part - I laid before and after laying of cable, complete all as specified and directed by engr-in-charge.
Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable in repair , complete all as specified and directed by Engineer-in-Charge
JOGINDER SINGH
CITY TOP ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .