Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical
BSNL ELECTRICAL DIVISION, MEYYANUR, SALEM 4
Replacement of Life Expired 6Nos.X7 TR conventional PAC units with 5 Nos.x7TR Microprocessor based HPAC for Media Gate Way Switch room at TE Meyyanur, Salem.(Sw Aux.works)
2023_BSNL_174192_1
No 22/EEE BSNL ED/SLM/2023-24/ dt 10.11.2023
Open Tender
Electrical Works
Item Rate
30 days
Meyyanur
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Accounts Officer (Cash), O/o GMT, BSNL , Salem
₹9,504
23 Nov 2023
10 Nov 2023
23 Nov 2023
10 Nov 2023
22 Nov 2023
10 Nov 2023
Amount
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 1.00mm (20Gauge)
Thickness 0.80 mm (22 gauge)
Providing fire proof canvas (Approx size 950 MM X 950 X 100 MM) and connecting 7 TR PAC unit mouth and supply air Duct inlet i/c S/F GI beading around the mouth and duct to arrest the leakage if any etc as required
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and laying following sizes of PVC insulated PVC sheathed armoured U/G cable of 1.1 KV grade, conforming to relevent IS on the wall/existing trench, existing cable trays i/c interconnections, end termination, gland earthing complete etc. as required
3 Core 1.5 Sqmm Copper conductor U/G Cable
Supplying and laying of 4cx16 sq.mm PVC insulated PVC Sheathed aluminium armoured UG cable on surface of wall i/c clamping etc. as reqd. (PAC Panel to PAC Unit)
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3 Core 1.5 Sqmm Copper conductor U/G Cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (28mm)
Supplying and laying 50 mm dia(1½ " dia) , 10 Kg/cm2 rigid PVC pipe on surface of wall for package drain with all accessories such as bend, elbow, union, tee, i/c making good the damages etc as required.
Providing MS frame work/extension to existing frame work/supports/ hangers/cable tray/ piping tray/roofing frame work etc fabricated with the following members i/c cutting, welding, drilling holes, threading the rods, required machine shop work, painting etc as required
75mm x 40mm ISMC channel STD
35x35x5mm MS angle
25 x 5 mm MS Flat
P/F 3mm chequered plate etc. as reqd
Providing signwriting name board made up of Acrylic sheet bearing make, Sl no. of PAC units, compressors, fan motors, Date of Installation, Estimate number, other required Technical information and fixing on suitable frame work with necessary accessories inside the plant room as given by Engineer in charge etc as required. Approximate Size (5'X3')
Dismantling of life expired 7TR PAC Unit (1 No indoor and 2 Nos outdoors) along with GI mouth connection, copper tubes, removing of unwanted ducts with Electrical cables and earth connection, cable/pipe trays . drain pipes ,shifting the dismantled items to the location (ground floor) as instructed by the Exchange-in-charge etc., as required
Yes Yes Electricals
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .