Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.5 LAccepted-AOC F 20 SHASTRI NAGAR DELHI52 | 1 | Accepted-AOC L1 | |
| 2 | 2₹2.7 L+₹13,664.50 (5.43%)Rejected-Finance | 2 | Rejected-Finance 2 | |
| 3 | 3₹2.7 L+₹17,845 (7.09%)Rejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | 3 | Rejected-Finance 3 |
Tender Value
₹2.6 L
EMD Value
₹5,199
Closing Date
22 Jan 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-II/CLZ
EEE-II/CLZ
Imp. Of existing electrical system at AMO office Ward 11 Timarpur under , civil line zone.
2024_MCD_181773_1
EEE-II/TC/2023-24/41.1
Open Tender
Electrical Works
Item Rate
45 days
EEE-II/CLZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹5,199
4 Apr 2024
15 Jan 2024
23 Jan 2024
15 Jan 2024
22 Jan 2024
15 Jan 2024
Amount
OD18810/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper (conductor single core cable etc as required. (Group-C)
OD18812/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. - (a) 3X 2.5 sq. mm
OD18813/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. - (b) 6 X 2.5 sq. mm
OD18814/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. - © 3 X 6 sq. mm
OD18815/2023-2024:Supplying and fixing of following sizes of steel conduit along with accessories in surface / recessed including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.-25 mm
OD18816/2023-2024:S&F metal box of 180mm x 100mm x 60mm deep (Nominal size) on surface or in recess with suitable size phenolic laminated sheet cover in the front I/c P&F 6 pin 5/6 & 15/16 amps. Socket outlet and 15/16 amps piano type switch, connection, painting etc as reqd
OD18817/2023-2024:Wiring for light/ power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
OD18836/2023-2024:Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.-a) 5/6 amp switch
OD18837/2023-2024:Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.-b) 3 pin 5/6 amp socket outlet
OD18838/2023-2024:Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required-c) 15/16 amp switch
OD18839/2023-2024:Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.-d) 6 pin 15/16 amp socket outlet
OD18840/2023-2024:Supply of 15" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters blades etc as reqd
OD18841/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)-a) 8 way,Double Door
OD18842/2023-2024:Extra for fixing the louvers/shutters complete with frame for a exhaust fan of all sizes
OD18843/2023-2024:Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
OD18844/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (a)Upto 35 sq. mm
OD18845/2023-2024:Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing as required.
OD18846/2023-2024:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
OD18847/2023-2024:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with Extruded Aluminium Batten prewired with high efficient LEDs with the following: (a) Total system wattage 20 watt +/- 5%, (b) Luminous efficacy lumens/watt >=95, (c) Power Factor >=0.95
OD18848/2023-2024:P & F of hot press moulded compound (SMC) fire retardent ( temperature resiistanceup to 200 C) IP -55 weather proof pole box of size inner dimenson 200X 1160X98 mm (NS) complete with the suitable arrangement for fixing of 02 nos of 6 to 32 amp single pole MCB & 63 amp double pole isolators MCB ( MCB and isolator excluded) with neutral link duly shorting on DIN channel with 02 nos of MS clamp with SS black plate of suitable size with danger monogramme properly printed on the cover etc. as required.
OD18849/2023-2024:Supply, Installation, Testing andCommissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan withBrush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2nos. canopies, shackle kit, safetyrope, copper winding, PowerFactor not less than 0.9, ServiceValue (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350RPM(tolerance as per IS : 374-2019), THD less than 10%, remoteor electronic regulator unit forspeed control and all remainingaccessories including safety pin,nut bolts, washers, temperaturerise=75 degree C (max.), insulationresistance more than 2 mega ohm,suitable for 230 V, 50 Hz, singlephase AC Supply, earthing etc.complete as required.
OD18911/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.-b) 63 amps
OD18912/2023-2024:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required.-a) single pole
OD18914/2023-2024:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
OD19158/2023-2024:Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling hole n cubicle panel, making connections, etc. as required.-100 AMP , 16 KA,TPMCCB
Lakshmi Traders
SRI BALAJI ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .