Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹32.8 L+₹3.2 L (10.9%)Rejected-AOC 51 212D 3E K V NAGAR NEAR ADARSH NAGAR KHERIA MOD AGRA UP 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹35.5 L+₹5.9 L (19.8%)Rejected-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹37.4 L+₹7.8 L (26.5%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L4 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
12 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Bharatpur
Provn of certain sanctioned work Part-3 under GE Bharatpur
2020_MES_370096_1
8960/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE Bharatpur
Class D category a(I)
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹80,000
Yes
14 Oct 2020
18 Aug 2020
14 Sept 2020
18 Aug 2020
12 Sept 2020
30 Aug 2020
60 days
Amount
Surface excavation n. exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out complete all as specified and as directed by Enginer in Charge
M&L for precast cement concrete 1:2:4 type B-1 (20 graded stone aggregate) kerb stone including form work set in CM 1:6 complete all as specified and as directed by Enginer in Charge
Supply and laying sand filling including spreading ,levelling in layers nexc 25 cm thick and well ramming and watering required complete all as specified and as directed by Enginer in Charge
M&L for broken stone or boulders in hardcore of gauge exc 63 mm but n exc 100 mm deposited spread and levelled in layers n. exc 15 cm thick watered and rolled/rammed to a true surface complete all as specified and as directed by Enginer in Charge
M&L 100 mm thick PCC 1:4:8 type D-2 using 40mm graded aggregate as in sub base of flooring complete all as specified and as directed by Enginer in Charge
M&L 75 mm thick PCC 1:2:4 type B-2 (40 mm graded stone aggregate) as in flooring laid in panels finished even and smooth without using extra cement complete all as specified and as directed by Enginer in Charge
Removing excavated material exc 250 mtr but n exc 500 mtr depositing where directed in soft / loose soil complete all as specified and as directed by Enginer in Charge
Cutting holes of superfacial area exc 150 sqcm but nexc 400 sqcm in brick or stone walls built in cement mortar complete all as specified and as directed by Enginer in Charge
S&F rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections,ms pipe) including distance pieces, cleats etc. conforming to Fe-410W Gde E-250 quality 'A' all as specified complete all as specified and as directed by Enginer in Charge
S&F rolled mild steel Hollow section square or rectangular of wall thickness 3.25 to 4.25 mm thick, work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections,ms pipe) including distance pieces, cleats etc. conforming to Fe-410W Gde E-250 quality 'A' complete all as specified and as directed by Enginer in Charge
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410W Gde E-250 quality 'A' complete all as specified and as directed by Enginer in Charge
S&F for expanded metal of mesh size 20 mm x 50 mm nexc 4 Kg per Sqm, cut to length, bent to shape required and tying with and including annealed ms wire not less than 0.9 mm dia or fixing with galvanised steel staples to steel members complete all as specified
Painting to new or previously untreated steel surfaces of any description over 10 cm in width or girth with two coats of synthetic enamel paint over a coat of zinc chrome primer including preparation of surfaces complete all as specified and as directed by Enginer in Charge
M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, bed plates, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork all as directed by Engineer-in-charge.
Taking down cement plaster from stone wall surfaces etc including raking out joints hacking for kery scrubbing down with water etc complete all as specified and as directed by Enginer in Charge
Rendering 15 mm thick in CM (1:4) on brick masonry surfaces or concrete surface finished fair & even without using extra cement complete all as specified and as directed by Enginer in Charge
M&L for preparation of newly plastered surface of walls and applying two coats of cement base paint of approved shade/tint over one coat of primer complete all as specified and as directed by Enginer in Charge
M&L 75 mm thick PCC 1:4:8 type D-2 using 40mm graded aggregate as sub base of floors etc. complete all as specified and as directed by Enginer in Charge
M&L for 25 mm thick rough dressed sand stone flooring laid dry and pointed in CM 1:3 complete all as specified and as directed by Enginer in Charge
M&L for Stone kerb (Sand Stone) of roughly squared stones of size 15cm x 30cm and not less than 45cm in length, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush complete all as specified and as directed by Engineer-in-Charge
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes etc not exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed by Enginer in Charge
Returning filling in incl spreading, levelling, watering & well ramming in layers not exc 25cm thick for soft/loose soil complete all as specified and as directed by Enginer in Charge
Removal of surplus spoil upto a distance n. exc 50 M complete all as specified and as directed by Enginer in Charge
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and as directed by Enginer in Charge
M&L for 40mm thick PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in damp proof course on horizontal surface using water proofing compound including necessary formwork complete all as specified and as directed by Enginer in Charge Note : - Supply only water proofing compound shall be measured and paid for separately.
Supply only Integral water proofing compound complete all as specified and as directed by Enginer in Charge
M&L for brick masonary with sub class "B' bricks,straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed by Enginer in Charge
M&L for brick masonary with sub class "B' bricks,straight or curved on plan any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed by Enginer in Charge
M&L for 10 mm rendering in CM 1:6 on fair faces of brick work finished even and smooth without using extra cement complete all as specified and as directed by Enginer in Charge
M & L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces with water proofing compound of walls, finished even and smooth without using extra cement complete all as specified and as directed by Enginer in Charge Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L rendering 5 mm thick in cement motar 1:3 on ceiling of concrete surfaces complete all as specified and as directed by Enginer in Charge
M&L for preparation of newly plastered surfaces of wall & applying three coats of white wash on ceiling on new plastered surfaces complete all as specified and as directed by Enginer in Charge
M&L for preparation of newly plastered surfaces of wall & applying three coats of white wash on wall on new plastered surfaces complete all as specified and as directed by Enginer in Charge
M&L for hardcore gauge n.exc 63mm, deposited, spread and levelled in layrs n.exc 15cm thick, watered and rammed to a true surface of broken stone or boulders complete all as specified and as directed by Enginer in Charge
M&L for PCC (1:2:4) typeB-0 (using 20mm graded stone aggregate), 25mm thick, as in Sub base all as directed by Engineer-in-charge.
M&L 50 mm thick PCC(1:3:6) type C1 as in plinth protection finished fair and even complete all as specified and as directed by Enginer in Charge.
S&F colour glazed tiles on verticle surfaces jointed in neat cement and pointed with coloured cement 300x200x6 mm over incl 10 mm th rendring in cm 1:4 complete all as specified and as directed by Enginer in Charge.
S&F non skid ceramic tiles colored 300x300x7mm thick in floor set and jointed in neat cement slurry and pointed in white or coloure cement over incl 15mm thick screed bed in CM 1:6 complete all as specified and as directed by Enginer in Charge
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed by Enginer in Charge
Formwork to flat surfaces of chajjas, chullah hoods, troughs and similar items including edges for rough finished surfaces complete all as specified and as directed by Enginer in Charge
Formwork to edges of concrete flats, roofs, floors etc and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces complete all as specified and as directed by Enginer in Charge
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed by Enginer in Charge
M & L for TMT bars 6 to 8 mm dia, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Enginer in Charge
M & L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for reinforcement cement concrete type A-1 (1:1.5:3) using 20 mm graded stone aggregate in slab supported on walls beams and columns in floors,roofs landings,balconies, canopies,deck slabs and in shelves and the like complete all as specified and as directed by Enginer in Charge
M&L 40 to 50mm thick sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4, complete all as specified and as directed by Enginer in Charge
S&F Rotational moulded polyethylene water storage tanks of 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in repair in position all as specified in SSR Part I complete all as specified and as directed by Enginer in Charge Make : SYNTEX/POLYCON/ROTEX
S&F steel tubing medium grade 25 mm bore with all fittings fixed complete to wall and or laid in floor complete all as specified and as directed by Enginer in Charge
S&F steel tubing medium grade 20mm bore with all fittings fixed complete to wall and or laid in floor complete all as specified and as directed by Enginer in Charge
S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floor complete all as specified and as directed by Enginer in Charge
S &F stop valves 25 mm bore cast copper allow with crutch or butter fly handle screwed down, screwed iron pipes.chromium plated fancy type complete all as specified and as directed by Enginer in Charge
S&F stop valves15 mm bore fancy type chromium plated with long shank and cup screwed down high presure, concealed type with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed by Enginer in Charge
S&F in bib tap cast copper alloy chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of 15 mm bore complete all as specified and as directed by Enginer in Charge
S&F ball valves brass high pressure with polythelene float and fly nut complete, screwed , iron pipes 20 mm dia complete all as specified and as directed by Enginer in Charge
S&F mild steel flat iron hold fast and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed by Enginer in Charge
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification and drawing. Make : Rajshree Doors or equivalent.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside complete all as specified and as directed by Enginer in Charge
S&F butt hinges 100mm long medium weight, colled rolled mild steel. complete all as specified and as directed by Enginer in Charge
S&F anodised, barrel tower bolts of extruded section and fixed 200 mm long complete all as specified and as directed by Enginer in Charge
S&F aluminium alloy handles 125mm size fabricated type anodized ISI marked.
S&F sliding bolt 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed
S&F steel ventilator with top hung shutter with glazing bars including hinges steel peg stay etc complete all as specified and as directed by Enginer in Charge
M&L two coats of synthetic enamel paint over a coats of red oxide primer over steel surfaces complete all as specified and as directed by Enginer in Charge
S&F in wash hand basin vitreous china white flat black size 550x400 mm excluding taps, waste chain and plug and porclean stopper but including bracket complete all as specified and as directed by Enginer in Charge
S&F Vitreous China Squatting pan, Orissa pattern, size 580 x 440mm white with integral foot rests connection to trap and to flushing pipe, anti-syphonage pipe etc.complete including making good to floor
S&F in 15mm dia chromium plated fancy type pillar tap cast copper alloy with capstan head etc complete all as specified and as directed by Enginer in Charge
S &F stop valves 15 mm bore chromium plated fancy type with crutch or butter fly handle screwed down, screwed iron pipes complete all as specified and as directed by Enginer in Charge
S&F in bib tap cast copper alloy chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of 15 mm bore complete all as specified and as directed by Enginer in Charge.
S&F 10 litres Vitreous china valveless, syphonic action type, flushing cistern, low level,white, with inlet, ball vaive, float and handle including brackets complete all as specified and as directed by Enginer in Charge Make PARRYWARE/CERA/HINDWARE
S&F flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and as directed by Enginer in Charge
S&F waste coupling of PTMT (half or full threaded) suitable for urinals (Minimum weight 32mm-45gms) complete all as specified and as directed by Enginer in Charge
S&F 32mm dia low density polyethylene pipes for wash basin waste pipe connection etc. complete all as specified and as directed by Enginer in Charge
S&F PVC connection 15mm size with PTMT nuts 450mm long. complete all as specified and as directed by Enginer in Charge
S&F Grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and as directed by Enginer in Charge
S&F Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by Enginer in Charge
S&F in 15mm bore dia of pipe stop valves, cast copper alloy, screwed down,high pressure, with crutch or butterfly handlle, screwed both ends for iron pipe or for union and fixed complete all as specified and as directed by Enginer in Charge
S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Enginer in Charge
S&F PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Enginer in Charge
S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Enginer in Charge
S&F PVC (SWR) bends any radius 110 mm bore complete all as specified and as directed by Enginer in Charge
S&F PVC (SWR) bends any radius 75 mm bore complete all as specified and as directed by Enginer in Charge
PVC (SWR), junction single, (Single T) equal or unequal 110 mm bore complete all as specified and as directed by Enginer in Charge
S&F 150x150mm Salt-glazed stoneware gully traps, square or round mouthed, type `P' all as complete all as specified and as directed by Enginer in Charge
PVC (SWR) nahani trap plain with grating including jointing with solvent cement complete all as specified and as directed by Enginer in Charge
S&F PVC (SWR) vent cowl complete all as specified and as directed by Enginer in Charge
S&F 110mm PVC (SWR) `P' trap complete all as specified and as directed by Enginer in Charge
M&L PCC(1:2:4) type B1 (using 20mm graded stone aggregates) in benching to manhole complete all as specified and as directed by Enginer in Charge
M & L for precast RCC 1:2:4 type B-1(using 20mm graded stone aggregate) for manhole cover including placing and set in CM 1:6 all as specified includung demolition of old RCC manhole cover. complete all as specified and as directed by Enginer in Charge
M&L for PCC 1:3:6 type C1 using 20mm graded stone aggragate as in bed blocks, coping etc including weathering slightly rounded or chamfered angles and throating making grovves for fixing of man hole cover including necessary form work complete all as specified and as directed by Enginer in Charge
M&L Slat-glazed stoneware drain pipes 150 mm dia laid in trenches and jointed complete all as specified and as directed by Enginer in Charge
M&L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC(1:4:8) type D2 complete all as specified and as directed by Enginer in Charge (using 40 mm graded stone aggregate)
Cutting into existing manholes for connecting new drains 150mm bore dia pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed by Enginer in Charge
Dismantling framed trusses nexc 10 m span complete all as specified and as directed by Enginer in Charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Enginer in Charge
Erection and fixing only of roof trusses (framed) complete all as specified and as directed by Enginer in Charge
Labour only for Fabrication, Erection and fixing (old obtained material used) for compound girders and stanctions, lattice girders, areial masts etc incl all stiffners, lattice bars etc comlete
Ditto all above item no 97 as in jack rafters, purlins etc connected to common rafters and running rails including fixing cleats etc complete all as specified and as directed by Enginer in Charge
M&L for MS work as in gusset plates, brackets each nexc 10 Kg conforming to Fe-290 complete all as specified and as directed by Enginer in Charge
Ditto all as above item no 99 but fabrication and fixing only complete all as specified and as directed by Enginer in Charge
M&L for mild steel work as in wind ties for roof covering including securing bolts etc. including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 Gde E-165 all as specified and directed by Engineer-in-Charge.
Pre painted galvatume alumimnium zinc coating GI based corrugated steel sheet 0.50 mm th, sheeting of anay colour having strength of 550 mpa as in roof covering etc,
Pre painted galvatume alumimnium zinc coating GI based plain steel sheet 0.50 mm th, sheeting of anay colour having strength of 550 mpa as in roof covering etc,
M&L for preparation of old untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
Demolition of stone masonary built in cement mortar incl pillars etc complete all as specified and as directed by Enginer in Charge
Dismantling asbestos cement (corrugated or semi corrugated) sheets in roof coverings complete all as specified and as directed by Enginer in Charge
Dismantling timber scantlings 40 Sqcm and over in section from unframed work complete all as specified and as directed by Enginer in Charge
Dismantling timber scantlings as in fillets, rails, posts, rafters, purlins, etc under 40 Sqcm in section from unframed work complete all as specified and as directed by Enginer in Charge
Dismantling post or struts (wood, steel or RCC ) any section, including taking out embedded portion in concrete, brick work, masonary etc and making good disturbed ground complete all as specified and as directed by Enginer in Charge
M&L for cutting chases, pinning in, making good to facing where required and pointing in CM 1:3 to end or edges for concealed water tubing exc 10 cm but nexc 20 cm girth complete all as specified and as directed by Enginer in Charge
Ditto all above item no 101 but fixing only complete all as specified and as directed by Enginer in Charge
Ditto all above item no 101 but fixing only complete all as specified and as directed by Enginer in Charge
Labour only for closing bolt holes or other similar holes in old aesbostos sheet by sealing with one bitumen and one plain G.I. washer on either side and including supply and fixing 8 mm dia bolt and nut, bolt nexc 25 mm in length complete all as specified and as directed by Enginer in Charge
M&L for 2mm thick fiber glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof, wall etc complete all as specified and as directed by Enginer in Charge
Ditto all above item no 114 but fixing only complete all as specified and as directed by Enginer in Charge
Fixing only thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc fixed with ‘L’ hooks complete all as specified and as directed by Enginer in Charge
S&F asbestos cement two pieces adjustable serrated ridge, 6 mm thick for corrugated or semi-corrugated sheets with 'L' or 'J' hooks complete all as specified and as directed by Enginer in Charge
S&F asbestos cement two pieces adjustable Plain wing ridge, 6 mm thick for corrugated or semi-corrugated sheets complete all as specified and as directed by Enginer in Charge
Fixing only two pieces adjustable serrated ridge for asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc fixed with ‘L’ hooks complete all as specified.
Removing building materials etc.(other than spoil payeable in earth work) to a distance exc 2 Km, including loading, unloading and stacking at the destination complete all as specified and as directed by Enginer in Charge
Dismantling ceiling frame work of any description and arrange ment with complete supporting members complete all as specified and as directed by Enginer in Charge
S&F GI snap grid frame work of size 600 x 600 mm for false ceiling including necessary notching. The snap grid shall consist of GI Main Tee and Cross Tee of size 35 x 25 x 0.7 mm, Main Tee suspended from the soffit @ 1200mm c/c with level clips, Cross Tee inserted/fixed into the slots of main T @ 600 mm to form a grid. The snap grid (main/cross tee section) shall be supported at ends all along the wall with GI angle of size 25 x 25 x 0.7 mm fixed to wall with suitable arrangement, fixed in grid support with 2.50 mm dia plain mild steel wire galvanised class 3 fixed in detached works etc to support snap grid, made of GI as per specification complete all as specified and as directed by Engineer-in-Charge.
S&F10 mm thick hollow section polycorbonate sheet fixed or laid/inserted to steel/timber/GI/Aluminium ceiling frame work with screws incl covering edge by Aluminium channel section 20 mm depth, complete all as directed by Engr-in-Charge
S&F in gypsum board not less than 6-7mm thick of size (595x595mm) both side PVC coated with one side decorated pattern complete all as specified and as directed by Enginer in Charge
Ditto above Item No 124 but fixing only complete all as specified and as directed by Enginer in Charge
M&L in repair POP moulding of any pattern as approved on site n exc. 10 cm girth finish even & Smooth with necessary rubbing with sand paper and final c finish with two coat oil bound distemper complete all as specified and as directed by Enginer in Charge
M&L for Complete removal of existing treatment,washing, rubbing down and stopping of distemperd and painted surface of old surface by Electric Rotary grinder including brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorscent salts and trading oil and greasy spots of Wall Surface removing of nails, making good holes , cracks etc , cleaning of floors , glasses, joinery of drops and splashes incl all arrangement necessary for execution of work,complete all as specified and as directed by Engineer-in-Charge.
M&L for including sand paper gentle rubbing to obtain smooth surfaces and applying Two coats of oil bound distempering white or tinted (copolymer based resin glue to be added for longer durability and better finish) using hand roller over one coat of water based white pigmented akali resistant priming paint , over 1mm thick wall care putty on Wall Surface including all necessary arrangement for execution of work, complete all as specified and as directed by Engineer-in-Charge.
Excavating over areas n.exc 1.5m deep and getting out of any type of soil complete all as specified and as directed by Enginer in Charge
Excavating over areas exc 1.5m but n.exc 3.0 m deep and getting out of soft disintegrated rock complete all as specified and as directed by Enginer in Charge
M&L for PCC M-15 type B2 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete. complete all as specified and as directed by Enginer in Charge
M&L for PCC 1:3:6 type C2 using 20 mm graded crushed stone aggregate in in surface channels and drains. complete all as specified and as directed by Enginer in Charge
M & L for reinforced cement concrete Design Mix M-30 as in foundations including rafts, footings, foundations beams, plinth beams, bases for columns etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M & L for reinforced cement concrete Design Mix M-30 as in walls of water tank etc complete all as specified and directed.
M & L for reinforced cement concrete Design Mix M-30 as in roof beams, cantilevers, bressummers and lintels over 1.5m span complete all as specified and directed.
M & L for reinforced cement concrete Design Mix M-30 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of formwork to flat faces of walls,retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses,etc.; vertical or to batter complete all as specified and as directed by Enginer in Charge
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and directed.
M & L for 10mm thick rendering in CM 1:3 with water proofing compond over 12mm thick rendering on other than fair faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed. Note:- WPC paid separately under item No 26.00
Supply only liquid water proofing compound complete all as specified and as directed by Enginer in Charge
M&L for preparation of newly plastered surfaces of wall & applying two coats of apex paint over one priming coat of approved shade/tint complete all as specified.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified.
M&L 40 mm th PCC 1:2:4 type B0 ( Using 12.5 mm graded stone agg.) as floors finishing cement concrete surface even and smooth using extra cement complete all as specified and as directed by Enginer in Charge
S&F anodised aluminium frame for ladder with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Enginer in Charge
M&L 100 mm bore cast iron pipes with spigot and socket ends centrifugallycast. Class B,in any length,laid in trenches complete all as specified and as directed by Enginer in Charge
M&L Nitobond (Forsoc) coating over concrete surface as complete all as specified and as directed by Enginer in Charge
S&F PVC coated rung size 265 x 165 x 25mm complete all as specified and as directed by Enginer in Charge
M&L applying waterbar as in joint of RCC concrete surface as complete all as specified and as directed by Enginer in Charge
S&F 100 mm bore cast iron vent pipe with CI bend with one end fixed mosquitoproof wire mesh fitted with 40x3 FI clamp all as directed by Engr-In-Charge
Surface preparation: Clean the surface thoroughly to make it free from dirt, dust, etc. and remove loose damaged concrete from the surface complete all as specified and as directed by Enginer in Charge
Providing skim coat to maintain profile of structural memebers by using latex B2 modified air cured mortar system prior to fibre wrapping (1 cement :3 part graded cleaned prepacked river sand 5 to 10% latex mortar by weight of cement 0.5 w/o ratio.) upto 10mm thickness including levelling,profiling,etc. complete.
Waerproofing Treatment : Carrying out waterproofing treatment on underground water tank as per standard practice & details given below ensuring safety in all respect. Supply & application of two coats of SE EC/UV two compound cementatious coating of entire prepared surface (consumption will be 1.5 to 2 kg/m2) using soft bristle brushes & rollers and as per OEM recommendations, carrying out suitable treatment for existing adjoining structures as per standard practice (as mentioned in SLA), carrying out all related works without any damage to the existing installations etc. complete as per site requirement & to the satisfaction of Engineer-in-charge.
Excavation in trenches in hard/dense soil not exceeding 1.5 meters wide and not exc. 1.5 meters deep and getting out excavated soil/bricks/sand complete for poles stays, cables etc complete all as specified and as directed by Engr-in-Charge.
Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified and as directed by Engr-in-Charge.
M&L of 20mm GI water tubing IS-1239 marked, medium grade, including all necessary pipe fittings such as sockets, all kind of reducers, Tees, bends, nipple any length, unions etc laid in trenches, on wall, under floor, under road on same or new route including making good of the existing old structure of any soze and type such as roads, PCC, RCC, stone wall, brick masonry etc complete all as specified and as directed by Engr-in-Charge.
S&F gun metal gate valve 20mm dia with iron wheel head, screwed both ends for jointing iron pipes, non rising, forged brass spindle class-1, ISI marked complete all as specified and as directed by Engr-in-Charge.
cutting existing steel tubing 40mm/50mm GI pipe for altraction or additins by provding and fixing tee including cutting and making fusion joint etc complete all as specified and as directed by Engr-in-Charge.
M &L connection of MS clamp /saddle including MS clamp piece made out of MS flat iron suitable for install ferrule and clamping branch connection comptete with GI socket welded on it FI strip suitable positioned at the centre of pipe including drilling as per site requirenment complete with MS nuts bolts washer and runbber packing for complete of size 100/80 mm pipe complete all as specified and as directed by Engr-in-Charge.
Supply & spread unwashed dry Machine sand for sand cushioning and covering the under ground cable in trenches complete all as specified and as directed by Engr-in-Charge.. (Note :- Punning thickness shall be measured.)
M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as specified and as directed by Engr-in-Charge.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 10 sqmm 2 core, 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole complete all as specified and as directed by Engr-in-Charge.
M&L concealed point wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in PVC conduit pipe with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the concealed surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards/ existing sunken box for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly complete all as specified and directed for the following :- Note : Chases cutting of item and making good to facing as original are deemed to be including with uniy rate (a) One light point controlled by one way switch.
(b) One fan point controlled by one way switch.
(c) One 3 pin 6 Amp socket point outlet on the same board with other switches
(d) One 3 pin 6 Amp socket point outlet on the independent board
All as per item No 164 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and as directed by Engr-in-charge
S&F socket outlet 2 in 1, 5 pin 5 Amps multi purpose flush type 230 volt complete all as specified and as directed by Engr-in-charge
S&F switch piano flush button single pole one way 6 Amps 230 volt grade complete all as specified and as directed by Engr-in-charge
S&F switch socket combinatin 2 in 1, 3 pin 5 and 15 Amp flush type multi purpose 230 volt complete all as specified and as directed by Engr-in-charge
S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board complete all as specified and as directed by Engr-in-charge
Distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 /415 volt of the following DB :-. (a) 4 way SPN with 200 Amp rated busbar 240 volts (double door)
(b) 8 way SPN with 200 amps rated busbar 240 volts (double door type).
(c) 4 way TPN with busbar 415 volts (double door)
Supply & fix 12 way VTPN Distribution Board (with provision for MCCB as incomer & WiNtrip MCB as outgoing) Make:C&S CSDBMCCB100DD12IP43 or equivalent complete all as specified and as directed by Engr-in-charge make in Indoasian/havells/L&T.
Supply and fix MCCB 415 volts 160 Amps 04 pole 36 KA (ICU= 50% ICS) complete all as specified and as directed by Engr-in-charge Make L&T/C&S/Indoasian/Havells
S&F MCB 240 volts 10 KA, rupturing capacity fixed in DB's of the undermentioned type and rating. complete all as specified and as directed by Engr-in-charge (a) MCB SP 240 volts 10-32 Amps
(b) MCB SPN isolator 240 volts, 40 Amps
(b) MCB TPN 63 Amps 415 volt
S&F Linear LED T8 tubular lamp of 20 watt with extruded aluminium body, PC diffuser and inbuilt driver with Batten suitable for LED T8 lamps , complete with all accessories internally pre-wired and including connecting to ceiling rose with three core flexible copper conductor cable of size 1Sqmm complete all as specified and as directed by Engr-in-charge Cat Part No:LTT8-20+DMLN1LT8-16, Make Crompton or equivalent in Bajaj/Havells/Philips/Crompton.
M&L batten holder insulated with back plate including suitable size of PVC round block complete all as specified and as directed by Engr-in-charge
Supply & fix exhaust fans AC single phase 230/ 240 V of size 200 mm sweep of with and including suitable size louvers complete all as specified and as directed by Engr-in-charge. Make: Havells Model: Ventil Air - DX White or equivalent makes in CG/Khaitan
S&F ceiling fan (White) of 1200 mm sweep copper wound with super energy efficient BLDC motor including remote, connecting wire PVC insulated twisted flexible 0.5 sqmm copper conducter canopy set, down rod, Shackle Kit, including all standard accessories complete all as specified and as directed by Engr-in-charge. Make: Havells model: Efficiencia Neo/ Crompton Energion HS-48 or equivalent in Bajaj / Panasonic / Orient.
Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than1.5 Mtr below the ground level connected to connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge ( Note:- Up to 7.5 Mtr length of pipe of 15mm dia and GI wire shall be deemed to be included in unit rate quoted by tenderer)
S&L pipe galvanised light class complete including fittings 40mm dia complete all as specified and as directed by Engr-in-charge
Material and labour for cutting suitable holes in existing masonary wall and fixing suitable size hume pipe for fixing of exhaust fan 200 mm dia and making good disturbed surfaces with cement mortar (1:4) and finished to match eisting surface complete all as specified and as directed by Engineer-in-Charge.
Supply, fixing and fabrication and testing desert cooler in GI body sheet with and including cooler fan motor size/sweep 450mm (fan blade only) 230 Volts, Single phase 50 Hz, 1400 RPM, heavy duty single sheet, totally enclosed. The overall dimesnions of the desert cooler shall not be less than 690mmx690mm x 1020mm with and including following accessories each complete all as specified and as directed by Engr-in-charge (a) Air grill of suitable size made out of 0.5mm PGI sheet including GSS arrangement with a knob for easy and smooth movement. (b) Front & Side panel made out of 1mm thick PGI sheet of suitable size and shape. (c) Water tank height shold not less than 11 inch made out of 2mm thick PGI sheet. (d) Submersible pump electric driven single phase 230 volts, 50 Hz of suitable discharge and head but motor capacity not less than 18 watt. Make : Khaitan/Crompton or equivalent make.(e) Service cord of 3 Core copper wire 1.5 Sqmm with plug top 5 Amp length not less than 2 metres. (d) Electronic fan dimmer 1000 watts AC 230 Volt for controlling the fan speed.(e) Complete electric wiring of desert coolers as required to operate fan and pump along with 5 Amp switches .(h) Make of PGI sheet. Tata/Jindal/National
M&L for fixing and grouting of MS Stand (adjustment type) suitable for desert cooler of above said size made out of angle iron section of size 40 x 40 x 5 mm with suitable size of fasteners on ground floor in windows of rooms, complete with two coats of synthetic enammled black paint over a coat of red oxide primer all as specified and directed by Engr in Charge.
Supply and install inverter type split units indoor/outdoor with insulated copper tubing, ecofriendly refrigerent, dual rotor copper bound invertor compressor ,copper condensor with anti corrosive fins complete with cordless remote control unit and dust filter for batter indoor air quality with 5 star rating and of capacity 1.5 TR with outdoor unit stand . Make: LG Model No LS-Q18MNZA, BLUESTAR 1C518DATU, CARRIER: 18K 5 STAR ESTER NEO HYBRIDJET INVERTER R32 1015
Supply and fixing voltage stabilizer suitable for split type AC, 1.5 Ton capacity, Rated Amps-12 Amps, voltage variation range between 130 to 300 volts. Make: V Guard/ Microtek/BLUE BIRD
Supply, install and commissioning Deep freezer, electric driven, 230V (Single phase), 50Hz, frost free, up to 400 Litre storage capacity having double door, minimum 5 star rating. Make : Bluestar : CHF400HGW /Voltas Classic 405 DDCF/Godrej: GCHW 410R2 DXB
Supply and fixing voltage stabilizer suitable for deep freezer capacity-400 ltrs, Rated Amps-6 Amps, voltage variation range between 100 to 300 volts all as specified and directed by Engr in Charge.. Make: V Guard/ Microtek
S&F sheet metal enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 volts. Make- L&T, Havells, Legrand complete all as per specified by Engr-in-charge.
M&L for wiring for circuit/submain wiring alongwith earth wire of size 2x4.0 sq. mm + 1x4.0 sq. mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC casing caping. all as specified and directed by Engr in Charge.
2. M&L submain wiring complete with 6 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit/sleeves with all PVC accessories concealed in wall, floor/ceiling etc all as specified and directed by Engr in Charge. Note : Chases cutting and making good as orignal will be measured and paid separatly
M&L submain wiring complete with 10 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 10 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit with all PVC accessories cocealed in wall, floor/ceiling etc all as specified and directed by Engr in Charge. Note : Chases cutting and making good as orignal will be measured and paid separatly
Cutting chases,pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing steps cills,sunshades,shelves lintel etc.and cutting chases for concealed water tubing or concealed conduit wiring etc,and making good cutting not exc 10 cm girth on stone concrete block or slab walls all as specified and directed by Engr in Charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .