Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹7.9 Cr |
Tender Value
₹9.1 Cr
EMD Value
₹18.1 L
Closing Date
25 Mar 2026, 3:00 pmClosed
Executive Engineer, BUILDING DIVISION VAISHALI, HAJIPUR
EE
Executive Engineer, Vaishali Building Division, Hajipur
Superintending Engineer, Building Circle Muzaffarpur
SE
Construction of Civil S.D.O. Residence /Type -D & Type-C at Quarter at Mahua Mandal Hajipur
124877
NIT 27/BCD/HAJIPUR/2025-26
Open Tender
CIVIL
Vaishali
• (a) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given. 16.1
Bid Security Amount in Rupees Total Bid Security Amount in Rupees Rs. 1810100.00 IFB
• 2 (i) Legal Status of Bidder 4.3(a)
(ii) Place of Registration.
(iii) write Principal place of Business
(iv) Power of attorney of signatory Bid 4.2(iv)
• Total value of civil engineering construction work, in Rupees, Performed in last five years. minimum annual financial turnover (in all classes of civil engineering construction works only) amount of construction work of at least the equal to the 50 % of estimated cost of works for which bid has been invited. The turn over will be indexed at the rate of 8% for a year
4.5(A) (a)
2020-21
2021-22
2022-23
2023-24
2024-25
• 4 Amout in Rupees related to Work Experience of Similar nature Satisfactory completed at least one similar work of value not less than 50% of estimated Cost 4.5(A) (b)
• 5 Minimum Quantities of work done as prime contractor in any one year during last five years, units shall be same as in Requirement column
Sl. No. Item 50%
1 Earth work 1470.11 CUM
2 Bricks Work 347.45 CUM
3 PCC/RCC Work 1035.19 CUM
4 Stone and Tile Flooring Work 1463.56 SQM
5 Plumbing Work Rs. 1437396.00
6 Electric Amount Rs. 51,93,249.50
• Electrical License The contractor or his identified sub-contractor should possess required valid electrical license for executing the building electrification works and should have executed similar electrical works for a minimum amount as indicated in Appendix in any one year 4.5A( d)
• (a) Amount of Existing commitments and ongoing works in Rupees Sec 2-1.4(A)
(b) Amount of Work for which Bid already submitted, in Rupees Sec 2-1.4(B)
• 8 Numbers and Maximum age of Equipments with bidder Type of Equipment Nos. Maxm. Age Sec 2-1.5
Concrete Mixer with Integral weigh Batching facility 2 5
Vibrator (Plate & Niddle) 4 5
Water Tanker 1 5
Steel shuttering 3000 sft 5
• 9 Name of the Personnel and Experince in years and Select from drop down list Personnel / Qualification 4.5(B) (b)
Site Engineer B.E. (Civil) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil + 7 year Exp. In Building construction or retired A.E. 1 No.
Site Supervisor Fresh Graduate in Civil or Diploma Civil + 02 Years Exp. or retired I.T.I Holder. 2 Nos.
• 10 Evidence of accesses to Financial Resources in Rupees Evidence of access to or availability of creadit facilities (10% of estimated cost), certified by bankers (for work under this bid). 4.2(i)
• 11 Proposed methodology and programme of construction Select from drop down list the proposed methodology and programme of construction, backed with equipment planning and deployment 4.3(l)
• 12 Litigation History. Select from drop down list. Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) 4.3(j)
• Affidavit Select from drop down list. Regarding statements made in the required attachments are true and correct. Sec-2, Affidavit
• Undertaking Select from drop down list. Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract. Sec-2, Undertaking
• Registration No.
• IT.& ST Registration & clearance Certificate
• Labour License
Character Certificate
NOC for Debar (If required)
CIVIL
PERCENTAGE
L1
1
15 documents required · 15 mandatory
₹10,000
Processing Fee: 5900
₹18.1 L
2 nd Pre-bid- at office of CE(North), BCD, PATNA 25-02-2026 03:30 pm
24 Jul 2026
12 Feb 2026
28 Mar 2026
12 Feb 2026
25 Mar 2026
12 Feb 2026
10 Mar 2026
Construction of Civil S.D.O. Residence /Type -D & Type-C at Quarter at Mahua Mandal Hajipur
Estimate Cost :- 8,01,16,757.00 (Civil Work) 1,03,86,499.00 (Electrical Work) 9,05,03,256.00 (Total) Last Date of Sale of BOQ:- 06.03.2026
Earnest Money :- 18,10,100.00 Date of Tender : 09.03.2026
Cost of B.O.Q :- 10,000.00 Time of Completion : 12 Months
Sl. No. Code Item Type-D Type-C SDO.Qtr Boundary wall Horticulture Internal Cam Sanitary Septic tank Desilt. RWH Quantity Unit Rate (Rs.) Amount (Rs.)
1 2.8.1 Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 843 217.62 M3 360.7
2 2.27.1 Extra for every additional lift of 1.5 m or part thereof in : Ali kinds of soil. 210 12 M3 49.4
3 2.26 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead 415 3 M3 123.9
4 2.28 Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 188 86 9.34 M3 287.3
5 Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared 287 100Sqm 357.2
6 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. Kl 107.2
7 4.1.3 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) 55 M3 3998.1
4.1.5 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 25 1 M3 3434
8 Extra for providing and mixing water prooding material in cement concrete work in the proportion recommended by the manufacturers. 219.6 50 Per Kg 57.16
9 Centring and shuttering including strutting, propping etc. and removal of form for.
10 5.9.1 Foundations, footings, bases of columns etc. for mass concrete. 66 M2 211.6
5.9.2 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. 99 M2 375.1
5.9.3 Suspended floors, roots, landings, balcnies and access platform. 1077 2 M2 437.5
5.9.4 Shelves (Cost in situ) 33 M2 437.5
5.9.5 Lintels, beams, plinth bams, griders, bressumers and contilevers. 1607 2.25 M2 404.7
5.9.6 Columns,Pillars, Piers, Abutments, Posts and Struts 978 M2 494.4
5.9.7 Stairs,(excluding landings) except spiral-staircaces. 175 M2 439.9
5.9.13 Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards 160 0.279 M2
5.9.19 Weather shade,Chajjas, corbels etc. including edges 214 M2 550.9
5.9.16.1 Under 20 cms wide 372 298 M
5.9.21 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 405 M2 518.9
11 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
5.22.7A Thermo-Mechanically Treated bars TMTC-500-8mm dia. 22115 478.23 Kg 94.5
5.22.7B Thermo-Mechanically Treated bars TMTC-500-10mm dia. 6000 35 Kg 92.6
5.22.7C Thermo-Mechanically Treated bars TMTC-500-12mm dia 11100 Kg 90.8
5.22.7D Thermo-Mechanically Treated bars TMT Fe-500-I6mrn dia. 33300 Kg 91.7
5.22.7E Thermo-Mechanically Treated bars TMT Fe-500-20mm dia. 22200 Kg 91.7
5.22.7F Thermo-Mechanically Treated bars TMT Fe-500-25rnm dia 22200 Kg 91.7
12 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
13 5.33.1.1 Concrete of M-25 grade with minimum cement content of 330 kg/cum M3
5.33.2.1 Concrete of M-25 grade with minimum cement content of 330 kg/cum 399 M3 5863.2
14 6.1.12C Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in : Cement mortar 1.:4 (1 cement: 4 coarse sand ) 90 M3 5116.3
15 6.1.14C Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement: 6 coarse sand ) 36 6 M3 4923
16 6.3C Extra tor Brick work in superstructure above plinth level upto floor V cum
250 mm thick Brick work in C.M (1:6) 249 M3 842.2
125 mm thick Brick work in C.M (1:4) 90 M3 842.2
17 9.21.1 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 107 M2 1775.3
18 9.96 Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
19 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ), transparent or dyed to required colour or shade, with necessary screws etc. complete:
9.97.4 150x10 mm Each
20 Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete. 57 Each
21 9.101.2 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.: Twin rubber stopper 57 Each 60.8
22 9.147D.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 129 M2 9471
23 10.15.2.1 Providing and fixing pressed steel door confirming IS code 4351 manufactured from commerical mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechnical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 293 M 432.6
24 Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 70 Each 165.4
25 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). 1818 Kg
26 9.48.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 2580 Kg 144.5
27 10.38.1 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows all complete with. 4.0 mm thick glass panes. 129 M2 876
28 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, 779 61.33 9.1975 M2 283.3
29 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such shades except white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete. 43 M2 862.4
30 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 202 M2 795
31 11.26.1 Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse sand 206 M2 1252.7
32 Kota stone slabs 20 mm thick in risers of steps skirting. Dado & pillars laid on 12 mm (average (thick cement mortar 1:3 (1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Details of cost for 10 sqm 27 M2 1334.9
33 Extra for Kota stone / sand stone in treads of steps and risers using single up to 1.05 metre.length 27 M2
34 11.20.4 Chequerred precast cement concrete tiles 22 mm thick with marbie chips of size 6 mm in footpath & coutyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning tec. Complete on 20 mm thick bed of cement mortar 1:4(1 cement:4 coarse sand) Ordinary cement without any pigments 254.05 M2 802.7
35 11.41.2 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete. Size of Tile 60x60 cm 567 M2 1638.6
36 11.46.2 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm. 98 M2 1191.8
37 8.9.1.2 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement complete Granite of any colour and shade 25
38 8.2.2.1 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm 24 M2
39 13.11.4 Cement plaster in course sand 12 mm cement plaster of mix: 1:6(1 cement: 6 coarse sand) 2791 16 M2 141.5
40 13.12.2 15 mm cement plaster on rough side of single or half brick wall of mix. 1:4(1 cement: 4 coarse sand ) 1603 M2 176.4
41 Extra for plastering exterior walls of height more than 10m form ground level for every additional height of 3 m or part there of 697 M2 44.4
42 13.24.2 6 mm cement plaster to ceiling of mix : 1:4(1 cement: 4 coarse sand) 1634 M2 125.6
43 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 6028 M2 105.4
44 13.77.2 Distempering with oil bound washa ble distemper of approved brand and manufacture to give an even shade. New work (two or more coats ) over and including priming coat with cement primer 4425 M2 102.3
45 13.81.1 Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and softwood) 241 M2
46 13.81.3 With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works 395 M2 34.6
47 13.93.1 Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade: 636 M2 84.5
48 13.116 Forming groove of uniform size from 12x12 mm and upto 25x15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. 744 M 47.1
49 13.17.1 CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement 160 0.375 M2 203.6
50 13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 1603 M2 137
51 12.33.2 Providing and laying brick tiles of class designation 100 over mumty root grouted with cement mortar 1:3 (1 cement:3 coarse sand) mixed with 2% if integral water proofing compound by weight of cement, over a 12 mm layer of cement mortar 1:3 (1 cement:3 fine sand) and finished neat. With F.P. brick tiles 107 M2 471.1
52 7.37.1.A Stone work ( machine cut edges veneer work) for wall lining upto 10 m height, backing filled with a grout of 12 mm thick cement mortar 1:3 (1 Cement : 3 coarse sand) and jointed with Cement mortar 1:2 (1 cement : 2 stone dust), including rubbing and polishing complete. (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) Dressing of sand stone in veneer work Dressing of sand stone in veneer work 150 M2
53 7.25.1 Providing and fixing gun metal cramps of required shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement: 2 fine sand) including making the necessary chases. 25x6 mm - 30 long 556 Each 117.7
54 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming tc IS 2645 in recommended proportions. (ii) 2nd course of 20 mm cement plaster 1:3 (1 cement:3 coarse sand)mixed with water proofing compound in recommended proportion, (iii) 3rd course of applying blown or/residual bitumen aplied hot at 1.7 kg. per sqm of area, (iv) 4th course of 400 micron thick PVC sheet.(Overlaps at joints of PVC shet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqni). 61 M2 480.6
55 22.20.1 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/ sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5 cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. 3 mm thick. 287 M2 472.5
56 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 287 M2 85.2
57 12.56X Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. 287 M2 1349.9
58 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 67 M2 436.6
59 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete 4 Each 189.4
60 2.35.1 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindone emulsifiable concentrate of 20% 78 Ltr. 200.9
61 2.37.1.1 Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termites' treatrnent(including the cost of chemical emulsion) Along external wall where the apron is not provided using chemical imulsion @ 7.5 liters / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With chlorpyriphos/Lindone E.C. 20% with 1% concentration 89 M 39.9
62 2.37.2.1 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.55 litres per linear metre including drilling and plugging holes etc With chlorpyriphos E.C. 20% with 1% concentration 89 M 49.1
63 2.37.3.1 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm diameter holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor. With Chlorpyriphos EC 20% with 1% concentration 287 M2 241.2
64 11.76 Derived Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I. 11 0.6 M3 3467
65 6.47A Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base.the drain duly.plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l, 114 M
66 Carriage of Materials
Coarse sand 573 30.91 M3 1639.6
Stone chips 729 18.12 M3 2052.6
Local sand 202 100 12.14 M3
Earth (1 Km Kutcha +2 km pucca) 270 M3 272.07
Manure (1 Km Kutcha +2 km pucca) 58 M3 272.07
67 Extra cost of Materials
Cement 11700 363 Each 11.7
68 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (overall area of door shutter to be measured) 107 M2 401.4
69 5.33A Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete
5.33A.1 All work upto plinth level 103 M3
5.33A.2 All works above plinth level upto floor V level
5.33A.2.1 Walls columns, pillars, posts cind struts 37 M3 5293.5
5.33A.2.2 Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc. 50 M3 5677.2
70 10.32.2 Steel work welded in built up sections/framed worK including cutting hoisting, rixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required. In gratings, frames, guard bar, ladders, railings, brackts. gates & similar works. 5078 KG 114.6
71 13.78.1 Applying one coat of cement primer of approved brand and manufacture on wall surface: Cement primer 1295 M2 38.6
72 13.79.1 Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade New work (three or more coats) 1295 M2 81.2
73 2.32 Clearing jungle including uprooting of rank vegetation ,grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 3380 100M2 697.4
74 Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of/and manure before and after flooding trench with water (encluding cost of imported earth,sludge or manure) 90 M3 44.7
75 Supplying and stacking of good earth at site including royalty but excluding carriage (earth measusred in stacks will be reduced by 20% for payment). 270 M3 143.5
76 23.4.3 Supplying and stacking a' site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment) Screened through sieve of l.S. designation 4.75 mm 58 M3 315.8
77 Mixing earth and sjudge or manure in porportion specified or directed. 328 M3 20.9
78 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately). 328 M3 30.1
79 23.10.3 Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more tili the grass forms a thick lawn free form weeds and fit for mowing including supplying good earth if needed. In rows 5 cm apart in either direction. 3380 100M2
80 23.14.1 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2;1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water,dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately): Holes 1.2 m dia, And 1.2 m deep. 150 Each 536.5
81 23.14.2 Holes 60 cm ciia. And 60 cm deep. 125 Each 69.3
82 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%). flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as drected, within a lead of 50 m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 68 M3 126.9
83 Trees 275 Each 200
84 Shrubs/Creeps 100 Each 100
85 6.18.4A Half brick masonry with bricks of class designation 100A in foundations and plinth in : Cement mortar 1:4 (1 cement: 4 coarse send) 68 M2
86 13.11.2 Cement plaster in course sand 12 mm cement plaster of mix: 1:6(1 cement: 6 coarse sand) 1:4(1 cement :4 coarse sand) 173 M2 152.9
87 P/N.S Compacting original ground supprting subgrade (Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction) 163 M3 74.3
88 3.18 RCD-21 Construction of subgrade and Earthen shoulder with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required to slope and compacted to meet requirement of table NO. 300-2) 89 M3 223.2
89 Providing designation 100 A one brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, 904 M2 444.8
90 16.42 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishingand tamping complete. 145 M3 4649
91 17.68.1 Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets,40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 29 Each
92 17.7.1 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 29 Each 2764.4
93 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings 29 Each 1500
4 17.10.1.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required : 13 Each 5231.5
95 17.28.2.1 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia 29 Each 104.4
96 17.32.4 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm 29 Each 1515.2
97 17.33 Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete 29 Each 713.3
98 17.73.2 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms 29 Each 424
99 17.70.1 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle t rap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 22 Each
100 17.70.2 Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms 17 Each
101 Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms 29 Each
102 18.22.2 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter 29 Each 190.1
103 17.35.1.2 Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 450 M 1036.5
104 17.37.1 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),including cost of cutting holes and making good the walls etc. For 100 mm dia pipe 8 Each 178.5
105 17.39.1.2 Providing and fixing plain bend of required degree. Sand cast iron S&S as per IS : 3989 65 Each 439.7
106 17.43.1.2 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 3989 10 Each 731.4
107 17.44.1.2 Providing and fixing single equal plain junction of required degree : Sand cast iron S&S as per IS - 3989 65 Each 707.3
108 17.49.1.2 Providing and fixing double equal plain invert branch of required degree: Sand cast iron S&S as per IS 3989 8 Each 760.8
109 17.56.1.2 Providing and fixing terminal guard : Sand cast iron S&S as per IS - 3989 8 Each 439.7
110 17.57.1.2 Providing and fixing collar : Sand cast iron S&S as per IS - 3989 8 Each 439.7
111 17.58.1 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm 850 Each 426.6
112 17.59.1 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 100 mm 8 Each
113 17.60.1.1 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Sand cast iron S&S as per IS: 3989 65 Each 1129.2
114 17.65.1 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 100 mm diameter pipe 750 M 46.1
115 18.58.2.1 Providing and fixing PTMT grating of approved quality and colour 150 mm nominal size square 100 mm diameter of the inner hinged round grating 60 Each 169.7
116 Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kg per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
12.78.1 75 mm diameter 35 M
117 Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete
118 Providing and fixing on wall face unplasticised -PVC molded fittings/accessories for unplasticised -PVC rain water pipes conforming to (S:4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
119 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc External work Exposed on walls
18.12.1 15 mm dia nominal bore 30 M 197.6
18.12.2 20 mm dia nominal bore 50 M 245.4
18.12.3 25 mm dia nominal bore 180 M 342
18.12.4 32 mm dia nominal bore 150 M 381.7
18.12.5 40 mm dia nominal bore 125 M 476.8
18.12.6 50 mm dia nominal bore 130 M 572.6
18.12.7 65 mm dia nominal bore 15 M 667.7
120 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
18.40.1 15 mm dia nominal bore 30 M 6.7
18.40.2 20 mm dia nominal bore 50 M 7.8
18.40.3 25 mm dia nominal bore 180 M 10
18.40.4 32 mm dia nominal bore 150 M 11.8
18.40.5 40 mm dia nominal bore 125 M 13.4
18.40.6 50 mm dia nominal bore 130 M 15.8
18.40.7 65 mm dia nominal bore 15 M
121 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
18.8.1 15 mm nominal outer dia Pipes 25 M 278.2
18.8.2 20 mm nominal outer dia Pipes 35 M 350.8
18.8.3 25 mm nominal outer dia Pipes 110 M 463.1
18.8.4 32 mm nominal outer dia Pipes 50 M
122 Providing and fixing brass stop cock of approved quality :
18.16.1 15 mm nominal bore 29 Each 303.8
18.16.2 20 mm nominal bore 29 Each 328
123 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
18.17.1 25 mm nominal bore 15 Each
18.17.2 32 mm nominal bore 13 Each 589.9
18.17.3 40 mm nominal bore 12 Each 707.3
18.17.4 50 mm nominal bore 5 Each 878.2
18.17.5 65 mm nominal bore 2 Each 1490.7
124 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
18.11.1 15 mm dia nominal bore 45 M
18.11.2 20 mm dia nominal bore 45 M 374
125 18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) :
18.19.2.2 Vertical 5 Each 777.9
126 Providing and fixing uplasticised PVC connection pipe with brass ions :
18.21.2.1 15 mm dia nominal bore 35 Each 85.2
127 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore 378 Each 434.2
128 18.50.1 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore 39 Each 715.1
129 18.52.1 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 111 Each
130 18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore 25 Each 500.4
131 24.1.1 Boring /drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS : 2800 (part I), including collecting samples form different strata, preparing and submitting strata chart / bore log, including hire & running Charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-Charge, upto 90 metre depth below ground level, all type of soil. 300 mm dia 150 15 M 486.8
132 24.2.1.1 Boring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS : 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer - in-Charge, beyond 90 metre & upto 150 metre depth below ground level. 300 mm dia 60 M 567.9
133 24.3.2 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150mm nominal size dia 150 M 660.1
134 24.4.1 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.100 mm nominal size dia 60 M 573.1
135 Gravel packing in tubewell construction in accordance with IS : 4097, including providing gravel fine / medium / coarse , in required grading & sizes as per actual requirement , all complete as per direction of Engineer - in-Charges. 12 Cum 1343.2
136 18.10.5 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 40 mm dia nominal bore 60 M
137 Development of tube well in accordance with IS : 2800 (part I ) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by 'V' notch method or any approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory,i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 72 Hour 916.8
138 24.13.2 Providing and fixing suitable size threated mild steel cap or spot welded plate to the top of bore well housing / Casting pipe, removable as per requirement, all complete for borewell of : 150 mm dia 3 Each 210.7
139 24.14.2 Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tube well as per IS : 2800 (part I ), including necessary bots & nuts of required size complete. 150 mm clamp 3 1 Each 1531.4
140 24.15.2 Providing and fixing Ball plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (Part I) 150 mm dia 3 1 Each 281.8
141 NS Rate Approved By S.E. B.C.D.MUZZAFARPUR Circle S/F/F 2 H.P. Cromption or any other apprioved make Motor and ISI make automatic starter mounted on a common wooden board etc. all complete job. 3 Each 25000
142 4.1.2 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) 9.34 M3 4420.8
143 6.1.12/1 Brick work with bricks of class designation 100A in foundations and plinth in : Cement mortar 1 .:4 (1 cement: 4 coarse sand ) 43.26 M3
144 5.1.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work puto plinth level 1:1:2 (1 cement:1 coarse sand:2 graded stone aggregate 20mm nominal size) M3 5961.9
145 O362 Supply of brick bats etc. M3 1181.24
146 0L01 Labour for filling of brick bats in soak pit. 9 Each 355.42
147 2.6.1 Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. AH Kinds of soil 13 cum
148 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work puto plinth level 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) 1 cum 4688.3
149 13.12.4 15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand) 8 M2
150 Neat cement punning 16 M2 40.5
151 19.19.4.1 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 560 mm internal dia 2 Each 1393.2
152 24.4.2 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 150 mm nominal size dia 15 M 673.5
153 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. M
154 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. M
155 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. M
156 19.30.1.1 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 4 Each 4266.8
Total Amount of SOR & DSR items for all works
Total Amount of Non schedule item 256121
Applying Correction factor @ 0.982 on Schedule items for All works
Executive Engineer, Vaishali Building Division, Hajipur.
BILL OF QUANTITY
Estimate for Provision to E/W & E/I in Construction of SDO Residence/Staff Residential Quarters C-type (G+3), D-type (G+3) Residential Quarters at Mahua, Distt-Vaishali.
Column1 Column2 Column3 Column4 Column5 Column6 Column7
SI No. Code No. Particular Qty. Unit Rate Amount
PART 'A' :-Proposed SDO RESIDENCE (GROUND FLOOR)
1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Batten Holder 21
Ceiling Fan point 10
Ex. Fan point 3
Call Bell point 1
Street Light point 8
1.3.1 Group - B p/pt. 947
2 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 140 per mtr 309
3 Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conducter SC cable in surface / recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq mm + 1 X 1.5 sq mm(for ckt) 158 per mtr 201
1.7.2 2 X 2.5 sq mm + 1 X 2.5 sq mm (For Computer + 2nos. 5/6A Switch & Socket) 150 per mtr 246
1.7.3 2 X 4 sq mm + 1 X 4 sq mm (for AC.) 70 per mtr 309
1.7.4 2 X 6 sq mm + 1 X 6 sq mm (for Light DB) 30 per mtr 422
1.7.12 4X 10 sq mm + 1 X 6 sq mm (for Power DB) 30 per mtr 925
4 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed PVC conduit as required
1.15.1 1x1.5 sq.mm (for inverter) 110 p.mtr 38
5 Supplying and fixing stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. As required. 10 each 358
6 Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections etc. As reqd. 13 each 414
7 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd. 10 each 531
8 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. 5 each 683
9 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. 8 each 632
10 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 3 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required. 2 each 1064
11 Supplying and fixing 2 pin, 5/6 amps ceiling rose on the existing junction box / wooden block including connection etc as required. 30 each 64
12 Supplying and fixing batten/angle holder including connection etc as required. 21 each 80
13 S/F electronic musical call bell suitable for single phase 230 volts complete bell as required. 1 each 351
14 S/F following way single pole & neutral, sheet-steel, MCB DB - 240 V on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar,interconnections, powder painted including earthing etc as required.(But without MCB/RCCB/Isolator)
2.8.7 12 way, Double door 1 each 2314
15 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.9.2 6 way ( 4 + 18 ), Double door, horizontal type 1 each 5132
15 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole 1 each 1198
16 S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
2.12.1 6 A to 32 A, Single pole 28 each 237
20 Earthing with copper earth plate 600 mm x 600mm x3mm G.I thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 mtr long etc. with charcoal /coke and salt as required. 1 per set 13721
21 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 20 meter 144
22 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 16 each 521
23 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
5.8.2 15 watt 6 each 1608
24 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
5.14.2 45 Watt 8 each 3382
25 Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 8 per set 1038
26 Supplying & fixing of following types lamp in the existing electrical fitting/fixtures etc. As reqd.
6.1.5 12 watt LED lamp 21 each 239
27 DSR SITC of 1200mm sweep, BEE 5 Star rated Ceiling Fan with BLDC motor suitable for 230V, 50 Hz ,single phase AC supply ,earthing etc complete as required. 10 each 2695
28 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
8.17.1 300 mm sweep 3 per mtr 2572
29 P/F following capacity rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc. as required.
2.4.2 125 A, 36 KA, FPMCCB 1 each 8676
30 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
31 Supplying and fixing following rating, 240/415 volts, ‘C’ curve, MCB suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
32 Supplying and fixing following rating, 240/415 volts, ‘C’ curve, MCB suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A, Double pole(1 SPARE) 2 each 1198
33 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.(15sq.ft extra for metering. unit for every qtr.) 8 Sq.ft 1809
34 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 p.mtr 6536
34 A/R Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd. 6 kg 871
35 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
7.9.1 2 X 16 sq. mm 6 Metre 518
7.9.2 4 X 16 sq. mm 6 Metre 1018
36 Supply of following sizes and core PVC/XLPE insulated, PVCsheathed (heavy duty) armoured electrical power cablewith aluminium conductor for working voltage upto 1.1 KV as required.
7.7.10 70 sq. mm, 3.5 core 110 Meter 748
37 Laying of one number additional pvc insulated and pvc sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioingi, protective covering and refilling the trench etc. as reqd.
7.1.2 Above 35 sq.mm and upto 95 sq.mm 95 p/mtr 326
SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM
63 DSR 17.1 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 14 KWP 54280
64 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
66 1.27.1 Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required. ( Make - Legrand/ Honeywell ) 20 each 234
67 39.13 Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
68 39.13.1 Copper Patch Cords of length 1m (3ft) 20 each 173
69 39.13.2 Copper Patch Cords of length 3m (10ft) 20 each 405
70 DSR39.23.1 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
71 39.23.1 6U Rack 1 each 6939
72 DSR 39.23 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
74 DSR 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 1 each 5278
75 NS Supply, Installation, Testing & Commissioning of Ethernet Managed Switch with fiber Module Along with AC Power Supply: 24 x 10/100/1000BASE-T ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing, Optional “standard mode” or “surveillance mode” management user interface etc as required. ( Make - D-Link/ Netgear/ Mortek/ HP) 1 each 20758
76 NS Supply installation testing & commissioning of Ethernet Unmanaged Switch Without fiber Module Along with AC Power Supply: 24x10/100/1000 Base T LAN switch including necessary connection of CAT 6 UTP cable etc as required. ( Make - D-Link/ Netgear/ TP-Link) 1 each 19070
77 Supplying and drawing UTP 4 pair CAT-6 PVC insulated and sheathed LAN cable through existing PVC conciuit including connection, testing etc. as required. ( D-Link )
78 1.58.1 1 run of cable 500 metre 52
79 NS Supplying and fixing of tooless RJ 45 information for CAT 6 U/UTP white colour Arteor Modules 1 along with built in crimping handfree min 5 times reconnection possible and shutter protection etc as required. ( Make - Legrand/ Honeywell/ Eqv. ) 20 each 545
STAFF RESIDENTIAL QUARTER
PART 'B' :-Proposed C-Type Residential Quarters (G+3)
80 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Button Holder 102
Street light 90 W 6
Down lighter 26
Ceiling Fan point 43
Ex. Fan point 19
Call Bell point 6
1.3.1 Group - A p/pt. 782
81 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 756 per mtr 309
82 Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conducter SC cable in surface / recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq mm + 1 X 1.5 sq mm(for ckt ) 673 per mtr 201
1.7.2 2 X 2.5 sq mm + 1 X 2.5 sq mm (For Computer + 2 nos. 5/6A switch & Socket) 420 per mtr 246
1.7.3 2 X 4 sq mm + 1 X 4 sq mm (for ac .pt.) 336 per mtr 309
1.7.4 2 X 6 sq mm + 1 X 6 sq mm (for Light DB) 112 per mtr 422
1.7.11. 2X 10 sq mm + 1 X 6 sq mm (for Power DB) 96 per mtr 551
1.7.6 2 X 16 sq. mm + 1 X 6 sq. mm earth wire (MS to Panel) 130 per mtr 775
83 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed PVC conduit as required
1.15.1 1x1.5 sq.mm (for inverter) 660 p.mtr 38
84 Supplying and fixing stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. As required. 43 each 358
85 Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections etc. As reqd. 47 each 414
86 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd. 54 each 531
87 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. 24 each 683
88 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. 24 each 632
89 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 3 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required. 6 each 1064
90 Supplying and fixing 2 pin, 5/6 amps ceiling rose on the existing junction box / wooden block including connection etc as required. 110 each 64
91 Supplying and fixing batten/angle holder including connection etc as required. 102 each 80
92 S/F electronic musical call bell suitable for single phase 230 volts complete bell as required. 6 each 351
93 S/F following way single pole & neutral, sheet-steel, MCB DB - 240 V on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar,interconnections, powder painted including earthing etc as required.(But without MCB/RCCB/Isolator)
2.8.6 8 way, Double door for building light 1 each 2591
2.8.7 12 way, Double door 1 each 2314
2.8.8 14 way, Double door 12 each 3201
94 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole 14 each 1198
95 S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
2.12.1 6 A to 32 A, Single pole 160 each 237
96 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
2.1.3 63 Amp, double pole (for every Qtr) 6 each 4463
97 P/F/F bus bar chamber with 4 strips of suitable size made of copper heavy duty complete with all accessoires including connection earthing the body etc.as reqd.
2.5.1 63 amps (for each Qtr.) 6 Each 3881
98 Providing and fixing following capacity double pole/ four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required.
2.6.2 63 A, double pole (for each Qtr.) 6 each 4418
99 Earthing with copper earth plate 600 mm x 600mm x3mm G.I thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 mtr long etc. with charcoal /coke and salt as required. 2 per set 13721
100 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 30 meter 144
101 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 67 each 521
102 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
5.8.2 15 watt 26 each 1608
103 Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 6 per set 1038
104 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
5.14.4 90 watt 6 each 5516
105 Supplying & fixing of following types lamp in the existing electrical fitting/fixtures etc. As reqd.
6.1.5 12 watt LED lamp 102 each 239
106 DSR SITC of 1200mm sweep, BEE 5 Star rated Ceiling Fan with BLDC motor suitable for 230V, 50 Hz ,single phase AC supply ,earthing etc complete as required. 43 each 2695
107 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
8.17.1 300 mm sweep 19 per mtr 2572
108 P/F following capacity rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc. as required.
2.4.7 400 A, 50 KA, FPMCCB 1 each 45651
109 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
110 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole (3 Spare) 9 each 1198
2.13.3 40 A to 63 A, double pole (One for Ground Floor + One for Building Light) 2 each 1198
111 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc. (18sq.ft extra for metering. unit for every qtr.) 24 Sq.ft 1809
112 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 p.mtr 6536
113 A/R Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd. 18 kg 871
114 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
7.9.1 2 X 16 sq. mm 10 Metre 518
7.9.3 4 X 25 sq. mm 2 Metre 1881
115 Supply of following sizes and core PVC/XLPE insulated, PVCsheathed (heavy duty) armoured electrical power cablewith aluminium conductor for working voltage upto 1.1 KV as required.
7.7.16 300 sq. mm, 3.5 core 180 per mtr 2764
116 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.5.1 Upto 120 sq. mm 170 metre 399
SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM
117 DSR Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 15 KWP 54280
PART 'C' :-Proposed D-Type Residential Quarters (G+3)
118 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Button Holder 109
Street light 90 W 6
Down lighter 20
Ceiling Fan point 43
Ex. Fan point 19
Call Bell point 6
1.3.2 Group - A p/pt. 782
119 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 742 per mtr 309
120 Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conducter SC cable in surface / recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq mm + 1 X 1.5 sq mm(for ckt ) 675 per mtr 201
1.7.2 2 X 2.5 sq mm + 1 X 2.5 sq mm (For Computer + 2 nos. 5/6A switch & Socket) 336 per mtr 246
1.7.3 2 X 4 sq mm + 1 X 4 sq mm (for ac .pt.) 336 per mtr 309
1.7.4 2 X 6 sq mm + 1 X 6 sq mm (for Light DB) 110 per mtr 422
1.7.11. 2X 10 sq mm + 1 X 6 sq mm (for Power DB) 100 per mtr 925
1.7.6 2 X 16 sq. mm + 1 X 6 sq. mm earth wire(ms to panel) 150 per mtr 775
121 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed PVC conduit as required
1.15.1 1x1.5 sq.mm (for inverter) 710 p.mtr 38
122 Supplying and fixing stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. As required. 43 each 358
123 Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections etc. As reqd. 53 each 414
124 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd. 53 each 531
125 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. 24 each 683
126 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. 24 each 632
127 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 3 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required. 6 each 1064
128 Supplying and fixing 2 pin, 5/6 amps ceiling rose on the existing junction box / wooden block including connection etc as required. 134 each 64
129 Supplying and fixing batten/angle holder including connection etc as required. 109 each 80
130 S/F electronic musical call bell suitable for single phase 230 volts complete bell as required. 6 each 351
131 S/F following way single pole & neutral, sheet-steel, MCB DB - 240 V on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar,interconnections, powder painted including earthing etc as required.(But without MCB/RCCB/Isolator)
2.8.6 8 way, Double door 1 Each 2591
2.8.7 12 way, Double door 1 each 2314
2.8.8 14 way, Double door 12 each 3201
132 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole 14 each 1198
133 S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
2.12.1 6 A to 32 A, Single pole 160 each 237
134 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
2.1.3 63 Amp, double pole (for every Qtr) 6 each 4463
135 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
2.5.1 63 A (for every Qtr) 6 each 3881
136 Providing and fixing following capacity double pole/ four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required.
2.6.2 63 A, double pole (for every Qtr) 6 each 4418
137 Earthing with copper earth plate 600 mm x 600mm x3mm G.I thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 mtr long etc. with charcoal /coke and salt as required. 2 per set 13721
138 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 30 meter 144
139 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 67 each 521
140 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
5.8.2 15 watt 20 each 1608
141 Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 6 per set 1038
142 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
5.14.4 90 watt 6 each 5516
143 Supplying & fixing of following types lamp in the existing electrical fitting/fixtures etc. As reqd.
6.1.5 12 watt LED lamp 109 each 239
144 DSR 9.2.3 SITC of 1200mm sweep, BEE 5 Star rated Ceiling Fan with BLDC motor suitable for 230V, 50 Hz ,single phase AC supply ,earthing etc complete as required. 43 each 2695
145 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
8.17.1 300 mm sweep 19 each 2572
146 P/F following capacity rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc. as required.
2.4.7 400 A, 50 KA, FPMCCB 1 each 45651
147 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
148 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole (3 Spare) 9 each 1198
2.13.3 40 A to 63 A, double pole (One for Ground Floor + One for Building Light) 2 each 1198
149 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc. (18 sq.ft extra for metering. unit for every qtr.) 24 Sq.ft 1809
150 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 p.mtr 6536
151 A/R Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd. 18 kg 871
152 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
7.9.1 2 X 16 sq. mm 10 Metre 518
7.9.3 4 X 25 sq. mm 2 Metre 1881
153 Supply of following sizes and core PVC/XLPE insulated, PVCsheathed (heavy duty) armoured electrical power cablewith aluminium conductor for working voltage upto 1.1 KV as required.
7.7.16 300 sq. mm, 3.5 core 180 per mtr 2764
154 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.5.1 Upto 120 sq. mm 170 metre 399
SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM
155 DSR 17.1 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 18 KWP 54280
PART-D (TRANSFORMER)
156 DSR Supplying, installation, testing and commissioning of following capacity (continuous loading) BEE 3 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, KNAN [K(K-Class insulating liquid) Natural Air Natural] copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better),Dielectric material shall be type -A, suitable for out door/indoor applications with Offload Tap Changer/ On Load Tap Changer (OLTC) ( below 500 KVA offload and above 500 KVA On Load Tap Changer) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sq.mm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS 1180 (Part-3) including first filling of filtered dehydrated Synthetic organic Ester oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with +12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 40 0C for oil and 45 0C for winding up to 200 KVA and 45 0C for oil and 50 0C for winding for above 200 KVA. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred for paint thickness for normal to medium corrosive
157 Supply, Installation, testing and commissioning of 2 Pole mounted DP providing I no 11kv,400A GOC in accordence with ie rules& local authority specifications and drawing and comprasing the following
158 N/S Supply, Installation, testing and commissioning of 2 Pole mounted DP providing I no 11kv,400A GOC in accordence with ie rules& local authority specifications and drawing and comprasing the following
159 N/S 2 nos. of 11 mtr long MS Pole complete with Pole, excavation, MS foundation and back filling complete as required.
160 N/S AB Switch Horn Gap, HT fuse set, Lighting Arrestor Set, Pole Stay wire 4 set, required channel complete etc as required 1 set 85000
161 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power H.T. cable with aluminium conductor for working voltage upto 11 KV as required.
7.8.3 120 sq. mm, 3 core 92 metre 1940
162 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.5.1 Upto 120 sq. mm 82 Metre 399
163 DSR supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:
164 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.(For Lightning Arrestor) 1 set 6884
165 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm). (For Lightning Arrestor) 30 metre 133
166 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 2 set 6323
167 Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. ( but without charcoal/ coke and salt ) as required. 2 set 12415
168 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 50 metre 1180
169 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) 50 metre 133
170 9.10 Providing and laying in position reinforced cement concrete 1: 2: 4 (1 : cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc. as required. (excluding reinforcement) 8 cum 8721
PART-E (FEEDER PANEL)
171 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
2.4.2 125A, 36 KA, FPMCCB 2 Each 8676
2.4.7 400 A, 50 KA, FPMCCB 2 Each 45651
2.4.20 800 A, 50 KA, FPMCCB 1 Each 38599
172 A/R SITC of ACB with microprocessor release with overload, short circuit neutral protection instantaneous ground fault protection (LSING) LES icU lew for Isec four total selectivity ambient temperature 50 dig, C in with breaking capacity of 50KA/60KA 800 A Capacity. 1 each 179604
173 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.4 40 A to 63 A, four pole (Spare) 2 each 2324
2.13.3 40 A to 63A , double pole( Spare) 2 each 1198
174 8.12 Supply and fixing fabricated Feeder pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator, with 40mm X 40mm X 5mm angle iron stand and complete in all respect etc and must be CPRI approved panel manufactures. (But without RYB LED lamp, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears, PCC work etc.) for 1 Outdoor Feeder Panel 25 Sq.ft 2261
175 A/R S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd. 32 kg 871
176 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 each 6536
177 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.17 400 sq. mm, 3.5 core (Double Run) 120 metre 3497
178 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.3 Above 95 sq. mm and upto 185 sq. mm 81 metre 336
179 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
7.9.2 4 X 16 sq. mm 4 metre 1018
7.9.1 2 x 16 sq.mm 4 metre 518
180 8.3 Providing and making steel pole collar with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 stone aggregate 20 mm ) of specified size and shapeincluding form work, plastering if required, curing etc. as required. (volume of pole/pipe not to be deducted) 1 cum 7501
181 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. 1 set 16675
182 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 29 metre 144
PART 'A' :-Proposed SDO RESIDENCE (GROUND FLOOR) Rs 1461295
PART 'B':--Proposed C-Type Residential Quarters (G+3) Rs 3190018
PART 'C':--Proposed D-Type Residential Quarters (G+3) Rs 3381286
PART 'D':--PART-D (TRANSFORMER) Rs 1447714
PART 'E':--PART-E (FEEDER PANEL) Rs 906186
Electrical Executive Engineer,
Electric Works Division, Muzaffarpur.
aoc.json
Purchase Order
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Check list farwarding.pdf
NIT • 1.76 MB
Letter no 7291 E-in-C bcd.pdf
NIT • 0.55 MB
Letter no 7292 E-in- C bcd.pdf
NIT • 0.64 MB
Nit No. 27 Year 2025-26.pdf
NIT • 7.34 MB
SBD NIT-27.docx
NIT • 0.27 MB
BOQ.xls
NIT • 0.21 MB
C2 corrigendum nit 27.pdf
Corrigendum • 0.30 MB
C1 corrigendum nit 27.pdf
Corrigendum • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .