Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | ₹4.5 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹4.9 Cr+₹38.2 L (8.45%)Rejected-Finance | ₹4.9 Cr+₹38.2 L (8.45%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹5.3 Cr+₹76.1 L (16.8%)Rejected-Finance | ₹5.3 Cr+₹76.1 L (16.8%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹5.4 Cr+₹88.9 L (19.7%)Rejected-Finance | ₹5.4 Cr+₹88.9 L (19.7%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹5.7 Cr+₹1.1 Cr (25.4%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹5.7 Cr+₹1.1 Cr (25.4%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹5.3 Cr
EMD Value
₹5.9 L
Closing Date
6 Feb 2024, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone PIN-900386 C/O 56 APO
ADDITION / ALTERATION TO JCOs AND OR MD ACCN UNDER AOR OF GE (S) UDHAMPUR
2023_MES_630678_1
87929-A/E8
Open Tender
Civil Works
Item Rate
455 days
Udhampur
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (S) Udhampur
₹5.9 L
Yes
5 Apr 2024
1 Dec 2023
13 Feb 2024
1 Dec 2023
6 Feb 2024
25 Jan 2024
Amount
Demolition of cement concrete (re-inforced) in roof (other than ground floor) beam,staircase landing ,chajja and similar work,complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided,complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Glazed ceramic colured tiles (joint free) of size 350mm x 250mm x 7mm / 450mm x 350mm x 7mm (Glazed ceramic tiles) thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.
Non skid coloured ceramic tiles (Joint free) 7 to 8 mm thick (square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors, set and jointed in neat cement slurry and pointed with coloured cement to match over and including 15mm thick Screed bed or bedding in cement motar 1:4 for laying floor finished surfaces , complete all as specified and directed.
Non skid coloured ceramic tiles (Joint free) 7 to 8 mm thick (square or rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors, set and jointed in neat cement slurry and pointed with coloured cement to match over and including 15mm thick Screed bed or bedding in cement motar 1:4 for laying floor finished surfaces , complete all as specified and directed.
Non skid coloured ceramic tiles (Joint free) 7 to 8 mm thick (square or rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in vertical surface, skirting, dado fixed with neat cement slurry and pointed in coloured cement to match the surface over and including 10mm thick with cement plaster in cement motar (1:3) complete all as specified and directed.
25 mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in floor finished even and fair, complete all as specified and directed.
Machine cut, kota stone slab flooring, 18mm to 20mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 20mm thick screed layer in cement mortar 1:4 including cutting, rubbing, grinding and mirror finish, complete all as specified.
Machine cut kota stone flooring (kota stone), 18mm to 20mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab,as in in skirting, dados, risers to steps etc, laid over and including 15mm thick rendering in cement mortar 1:3 including cutting, rubbing, grinding and mirror finish, complete all as specified.
Taking down cement plaster any description on brick or stone or cement concrete wall including raking out joints, hacking for key, scrubbing down with water etc ,complete all as specified and directed.
Green marble work 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over and including 15mm thick screed as bedding layer in CM 1:4,complete all as specified and directed.
Making of moulding full round of kota / marble stone ,complete all as directed.
Rendering 15mm thick on fair faces of other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing of liquid water proofing compound in the proportion as mentioned in manufacturer's instructions . Note : Liquid Water proofing compound to be measured and paid for separately.
Rendering 10mm thick in cement mortar 1:6 on brick work or concrete surfaces and finishing the surface even & smooth without using extra cement,complete all as specified and directed.
Rendering 5mm thick in cement mortar in 1:3 on ceiling finishing even and smooth without using extra cement ,complete all as specified and directed.
Chipping /removing loose concrete up to reinforcement bars, without damaging the reinforcement, removing all the loose materials and to make all the exposed surfaces free from oil, dust and all impurities etc , complete all as specified and directed.
Removing corrosion of steel reinforcement by mechanical means like wire brushing, chipping to remove loose rust and then applying rust removal solution by using brush application, leaving the surface for at least 15 to 30 minutes, then removing loose materials by scrubbing or with brush and applying polymer bond to the old concrete surface before applying Polymer mortar , complete all as specified and directed. Make :- SIKA- SIKA Rust off 100 or SIKA S.B.R or Latex Power FOSROCK - Reebaklens RR or Nitobond AR
Application of Corrosion Inhibitor: Providing & applying One coat of Concrete Penetrating Corrosion Inhibitor (Surface applied) which works on Bipolar Inhibition Mechanism on entire concrete surface to be repaired by using brush or spray at 250 ml per Sq.mt./Coat or as per manufacturer’s specification and prior to application of first coat of anti corrosive coating to reinforcement , complete all as specified and directed. Make :- SIKA - Feroguard 903,FOSROCK - Auramix BCI
Providing and applying Polymer modified cement mortar of average thickness 15-20mm using Polymer in one or more layers in proportion 1:5:15 of Polymer Cement Quartz Sand as manufacturer’s specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc and by finishing the surface with 12mm thick (1:3) Cement sand plaster , complete all as specified and directed. . Make :- SIKA - Sika 122 WL,FOSROCK - Renderoc S2
Providing and applying Polymer modified cement mortar of average thickness 30-40mm using Polymer in two layers in proportion 1:5:15 of Polymer Cement Quartz Sand as manufacturer’s specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc and by finishing the surface with 12mm thick (1:3) Cement sand plaster , complete all as specified and directed. . Make :- SIKA - Sika 122 HS FOSROCK - Renderoc HS xtra
Shear Connectors: Make 10/12 mm dia holes using heavy duty electrically operated hammer drills in the concrete of RCC members to a depth of about 75 mm at 500 mm c/c or at suitable grid in zig-zag fashion, clean the holes using air jet and fix pre-fabricated 100 x 50 mm L-shape 8 mm dia rebar using Anti Corrosive protective coating so that 75 mm out of 100 mm is inserted inside the concrete and 25 mm remain outside along with 50 mm bend. The shear connectors are used to tie the additional reinforcement bars. FOSROCK - HILTI, Ficher
Bond Coat: Providing & applying One coat of structural grade epoxy bond coat by brush conforming to ASTM-C-882-87 to the prepared concrete surface to be repaired / strengthened. This is applied prior to the application of polymer repair mortar / epoxy mortar / Microconcrete to have monolithic action between old concrete surface and new concrete surface. Make :- SIKA - SIKADUR 32LP, HIBOND
Providing Micro concrete jacketing to walls/ columns or beams of thickness upto 75 mm using polymer modified cement premixed quartz sand aggregate packed in bags of standard manufacture, for high early strength of 40 N/mm sq.cm of approved brand. The dry product is to be mixed with 12.5% water by weight, along with washed and poured into rigid form work moulds & tamped properly, & cured for 3 days. Payment is to be made by weight premixed of micro concrete product consumed as per site register records. No extra payment shall be made for shuttering or any other material , complete all as specified and directed. . Make :- SIKA - Sika Rep microconcrete-4, FOSROCK - Rendero CRG.
Providing and applying priming cum bonding coat of polymer of approved make and quality as approved by engineer- in - charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc. Make :- SIKA - SIKALalex or SRB, FOSROCK- Nitobond EP
Anti corrosive coating to exposed reinforcemennt providing and applying two coats of anti corrosive protective coating(CBRI/CSIR Tecnology) for reinforcement bars by brush sprinkle so as to get rough surface complete. Note:- For items 17.00 to 26.00. (i) Work shall be executed only through authorised applicators of the same Manufacturer. (ii) Under mentioned Non Destructive tests should be conducted at site. (a) Rebound hammer test. (b) Ultra Sonic Pulse Velocity test. (c) Half cell potensial test. (d) Corbonation test. (iii) Site for application is at various locations and height varies up to 15m (iv) All Scaffolding work and safety measures such as provision of props and supports shall be of steel and extent of provision shall be entire to satisfaction of GE. (v) Mode of measurement for items: For the purpose of the measurement of these items the surface area of the patch of the concrete considered for repair shall be taken. (vi) Testing of cube strength of polymer modified cementious mortar shall be independently carried out as per manufacturers instructions and record shall be maintained. (vii) After obtaining approval of the make of the products the contractor shall give a letter from the same manufacturer regarding the details of the agency and the name of person to be deployed for carrying out repair & Supervision of the work. (viii)T & P shall be strictly as per manufacturer’s instructions. (ix) Necessary Jacks shall be erected to support various floors before exposing columns/ beams for repair & it shall also be ensured that no damage is made to existing structure during the repair process & all safety norms shall be followed.
Supply only liquid water proofing compound.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Square Metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt ), complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed.
Pressed steel frames of size 125mm x 60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, hinges, lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C-0 using 12.5mm graded crushed stone aggregate, complete all as specified and directed.
Pressed steel frames of size 105mm x 60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, hinges, lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C-0 using 12.5mm graded crushed stone aggregate, complete all as specified and directed.
Factory made, 2nd class hard wood (Sal/Hollock), 35 mm thick, plain framed, panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both sides. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
35 mm thick 2nd class hard wood (Sal/Hollock) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members of door shutters as specified in SSR- 2009 Part-I Section 8.24(a),complete all as specified and directed.
Factory made box type steel windows with double shutters (inside for wire mesh & out side for glass) including hinges, steel handle, tower bolt and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat of red oxide zinc crome primer, complete all as per specification & shown on drawing No. CEUZ/TD/1517/15 sheet 1/3 to 3/3 complete all as specified and diredcted.
Factory made box type steel ventilators top hug with double shutters (inside for wire mesh & out side for glass) including hinges, steel handle, tower bolt and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat of red oxide zinc crome primer, complete all as per specification & shown on drawing No. CEUZ/TD/1517/15 sheet 1/3 to 3/3 complete all as specified and diredcted.
Mild steel framed work such as grills, gratings, manhole cover frames etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed.
Sheet glass, 4mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm.in each pane, fixed to steel or metal frames complete all as specified and directed.
Figured Sheet glass, 4mm thick, figured glass and glazing with oil putty in square n exc 0.5 Sqm.in each pane, fixed to steel or metal frames complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm dia and fixed with Stainless steel wire staples complete all as specified and directed.
Rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; complete conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed.
Plain, solid, straight chowkats and frames of 2nd class hard wood, wrought, framed rebated on the soild, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as specified and directed.
18/19mm thick prelaminated particle board exterior grade prelaminated, one side with decorative choice lamination and other side balancing white lamination fixed with screws to frame work for kitchen cabinets and cup boards etc includimg 6mm thick wood beading all around, complete all as specified and directed.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed.
Walling of random rubble stone masonry, brought upto courses, well bonded, bedded and solidly hearted built in CM 1:6, complete all as specified and directed. Note:- PCC bond stones shall be measured and paid separately & volume of bond stones shall be deducted from stone masonry.
All as per item No. 44.00 here-in-above but except stone.
Precast concrete block (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in bond stones set in cement mortar 1:6, complete all as specified and directed.
Extra over stone walling of lime or sand stone for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm, complete all as specified & directed.
Flush pointing to random rubble masonry in CM (1:4), uncoursed or brought upto courses , complete all as specified & directed.
Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
All as per item No. 49.00 here-in-above but except brick.
Brick work with sub class 'B' bricks, straight or curved on to any radius, built in half brick in cement mortar 1:4 complete all as specified and directed.
Providing cement concrete 1:2:4, type B-0 using 12.5mm crushed stone aggregate as in steps, seismic and other similar bands, parapets and railings up to 60 cm in height, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles. complete including use of form work complete all as specified and directed.
Roughing surfaces of old concrete surfaces by picking up , sweeping,cleaning and washing down with water to remove dust etc including taking down tar felt and brushing neat cement slurry @ 3kg / Sqm including 20mm thick screed bed in CM (1:4) finished even and smooth mixed with liquid water proofing compound as per manufacturer's instruction, complete all as specified and directed. Note:- Liquid Water Proofing compound shall be measured and paid seperatly as supply only.
Priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) 3mm thick and weight not less than 3 Kg/Sqm reinforced with non woven spun bonded polyester reinforcement < -2 C cold flexibility. The layer of the membrane shall be laid using butane torch and sealing all joints properly. The minimum side lap and end lap shall be kept at 150mm lap joint respectively with center layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/ Sqm blinded with fine sand in dry condition @ 0.50 Kg/ Sqm including cutting grooves (50mm x 50mm) in parapet and inserting edges of membrane and mending grooves damage by cement mortar (1:4) and including two coats of aluminium paint over a coat of primer on top surface finished in all respect as per directed by Engr-in-Charge. Note:- Laying of the membrane shall be got done by authorized applicator of the membrane manufacturer.
PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection (50mm thick ) finished even and smooth , complete all as specified and directed.
300mm long aluminium, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed , complete all as specified and directed.
Continuous (piano) hinges 30mm width of flap (when open), mild steel, bright finish or elec- tro galvanised , complete all as specified and directed.
Mild steel pressed steel handle, oval type, stove enamelled black 150 mm long , complete all as specified and directed.
Hasp and staple alumnium anodised lncluding bolt to hinges plate 100mm and fixed with screws, complete all as specified and directed.
Aluminium anodized 150mm long barrel tower bolt of extruded section and fixed complete all as specified and directed.
Aluminium handles cast type anodized of size 150 mm complete all as specified and directed.
Second class hard wood small fittings such as brackets of any type, shaped door and window stops and the like including all necessary Labour; articles not exceeding 200 Cu. cm each , complete all as specified and directed.
Butt hinges 100 mm, medium weight, cold rolled mild steel, complete all as specified and directed.
Butt hinges 50 mm, medium weight, cold rolled mild steel, complete all as specified and directed.
Butt hinges 75 mm, medium weight, cold rolled mild steel, complete all as specified and directed.
Mild Steel 300mm, ordinary rat tail rod patttern springs including roller & roller plate , complete all as specified and directed.
Mild steel barrel tower bolts, stove enamelled black, with bright bolt 200mm long , complete all as specified and directed.
Harrison curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc fixed in repairs , complete all as specified and directed.
Solid PVC Door Frames of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawings complete all as specified and directed.
Vitreous China wash basin, white, flat back, size 450mm x 300mm excluding tap, chain, plug but including brackets, waste fitting 32mm dia ,brass chromimium plated for glazed ware sink, basin,with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed in repair , complete all as specified and directed.
Fancy type pillar taps single lever mixer 15mm dia bore, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, screwed for iron pipe and fixed in repair
Preparing new wooden surfaces and applying two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces of any description, not otherwise described over 10 cm width or girth, complete all as specified and directed.
Preparing new steel surfaces and applying two coats of synthetic enamel paint on steel surfaces over a coat to red oxide primer any description, not otherwise described over 10 cm width or girth complete all as specified and directed.
Preparation of new plastered or unplastered surface of ceiling and applying three coats of white wash,complete all as specified and directed.
Preparing new plastered surfaces and applying 3mm wall care putty on wall surface and smoothening the surface with sand papers / Mechanised sanding etc and applying two coats of oil bound distemper, complete all as specified and directed.
Preparing new plastered surfaces and appling two coats of weather proof exterior emulsion paint including preparation of new plastered surfaces of any description and applying 3mm thick layer of wall care putty on walls to give uniform surface , complete all as specified and directed.
Vitreous China squatting pan, Orissa pattern, of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl cement concrete bedding and connection to antisyphonage pipe etc including making good to floor , fixed in repair, complete all as specified and directed.
Supply only cast iron 'P' trap 100mm dia, complete all as specified and directed.
PVC valveless, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, fixed in repair, complete all as specified and directed.
Supply only flush pipe of PVC 32 mm dia for low level cistern , complete all as specified and directed.
PTMT grating doom 125mm dia fixed to floor trap ,fixed in repair, complete all as specified and directed.
Brass chromium plated tubular towel rail 20 mm dia, "D" type, 60 cms long between flanges with and including chromium plated brass brackets, brass screws fixed in repair, complete all as specified
PVC connection 15mm size with PTMT nuts of lengh 450mm , complete all as specified and directed.
Eye door viewer (magic eye) fixed in position for door shutters in repair , complete all as specified and directed.
Steel peg set colour coated of six as per sample held in GE office, complete all as specified and directed.
Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm including 32mm waste fittings brass chromium plated etc ,fixed in repair,complete all as specified and directed.
Stainless steel plate racks of size 600mm x 750mm x 250mm and thickness of SS strip of 1mm fixed on wall etc ,complete all as specified and directed.
PCC (1:3:6) Type C-1, using 20mm graded crushed stone aggregate as in surface channel & drain complete all as specified and directed.
Cement concrete 1:5:10 type E-2 using 40mm graded crushed stone aggregate as in filling under sunken floor, complete all as specified and directed.
Dismantling cast iron pipes & reinforced concrete drain pipes, jointed in cement mortar of dia 75/100mm ,complete all as specified and directed.
Cast iron 100mm bore Spun cast soil, waste pipes, in any length with or without ears with lead joints, laid in trenches or in floors complete all as specified and directed.
Cast iron 75 mm bore Spun cast soil, waste pipes, in any length with or without ears with lead joints, laid in trenches or in floors complete all as specified and directed.
Cast iron 100mm bore Spun cast soil, waste pipes, in any length with or without ears with lead joints, fixed to walls duly apply a coat of bitumenous black paint, complete all as specified and directed.
Cast iron 75 mm bore Spun cast soil, waste pipes, in any length with or without ears with lead joints, fixed to walls duly apply a coat of bitumenous black paint, complete all as specified and directed.
Cast iron 50 mm bore Spun cast soil, waste pipes, in any length with or without ears with lead joints, fixed to walls duly apply a coat of bitumenous black paint, complete all as specified and directed.
Cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore complete all as specified and directed.
Cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) for 75mm bore ,complete all as specified and directed.
Stack clamps made out of 50 mm X 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100/110 mm bore pipe ,complete all as specified and directed.
Stack clamps made out of 50 mm X 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore pipe ,complete all as specified and directed.
Cast iron branch pieces single, equal or unequal ordinary or inverted (spigot or socket type) or with parallel branches of 100mm dia ,complete all as specified and directed.
Cast iron branch pieces single, equal or unequal ordinary or inverted (spigot or socket type) or with parallel branches of 75mm dia ,complete all as specified and directed.
Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc including cleaning or removal to store(measured overall as fixed along the centre line over fittings and accessories),complete all as specified and directed.
110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
PVC (SWR) Bends any radius for 110mm bore complete all as specified and directed.
75 mm dia, cast iron vent cowl,complete all as specified and directed.
50 mm dia, cast iron vent cowl,complete all as specified and directed.
Cast iron work in lids for oval access doors for 75mm bore pipes and fittings including all necessary threading and nut/bolt required .
Cast iron work in lids for oval access doors for 100mm bore pipes and fittings including all necessary threading and nut/bolt required as directed .
Providing reinforced cement concrete type B-1 (1:2:4) (using 20mm graded crushed stone aggregate) as in chullah hoods, chajjas and similar articles, including use and waste of necessary form work complete all as specified and directed.
Providing TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending and binding with & including MS wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
Form work to flat rough finished surfaces of chullah hoods, chajjas, troughs and similar items including edges for flat rough finished surface, complete all as specified and directed.
Taking up or down 15mm dia bore steel tubing with connections for cleaning for refixing or removing to store yard ,complete all as specified and directed.
Taking up or down 20mm dia bore steel tubing with connections for cleaning for refixing or removing to store yard ,complete all as specified and directed.
GI tubing, medium grade of 15 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches complete all as specified and directed.
GI tubing, medium grade of 20 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor /trenches complete all as specified and directed.
Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed bore dia of pipe 15 mm fixed in repair ,complete all as specified and directed.
Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed bore dia of pipe 20 mm fixed in repair ,complete all as specified and directed.
Stop valves/ angle valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, screwed both ends for iron pipe or for unions chromium plated of size 15mm bore and fixed in repair complete, all as specified.
Stop valves/ angle valve with long shank and cup (concealed type), cast copper alloy, chromium plated, fancy type, screwed down, high pressure, screwed both ends for iron pipe or for unions chromium plated of size 15mm bore and fixed in repair complete, all as specified.
Fancy type bib tap cast copper alloy, screwed down, screwed for iron pipe of size 15mm bore chromium plated,fixed in repair complete, all as specified.
Shower rose brass chrominium plated 125mm with arm and without swivel joints to steel pipe of size 15mm bore fixed in repair. complete all as specified and directed.
Dismantling water tank of capacity exc 500 but not exc 1000 and remove to Store complete all as specified and directed.
Rotational moulded polyethylene water storage tank 1000 Ltrs capacity (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) complete and making connections with existing water supply line ,complete all as specified and directed.
Stainless steel soap dish size 160mmx160mmx90mm , fixed to plugs with chromium plated brass screws, fixed in repair complete all as specified and directed.
Brass CP mixer 15mm bore for mixing hot & cold water screwed down for iron pipe with wall flange,fixed in repair complete, all as specified.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
75mm thick PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in sub base floor, complete all as specified and directed.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 50 mm thick sand cushioning, joints of tiles filled with dry sand and compacted with mechanical vibrator,complete all as specified and directed.
Plain cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone agg) as in coping, benching, kneelers, apex stones, bed plated, kerb stones etc; including weathering, slightly rounded or chamfered angles and throating including necessary formwork and finishing the exposed surfaces, complete, all as specified and directed.
Demolition and breaking up drain pipes 150mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed.
Demolition and breaking up drain pipes 200mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed.
Brick work with sub-class 'B' bricks in one brick thick honey comb walling, built in cement mortar 1:6, complete all as specified and directed.
Excavation over areas n exc 1.5 m deep and getting out in any type of soil complete all as specified.
Excavation in trenches n.exc 1.50m wide & n.exc 1.50m deep for foundation etc or for shafts wells cesspits ,manhole pier holes etc n. exc 10 sqm on plan and n exc 1.5 m depth and getting out in any type of soil, complete all as specified and directed.
PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in any type of soil, complete all as specified.
Removing excavated material (soils) exceeding 250 m but n.exc. 500m and depositing where directed at a level not exceeding 1.5m above the starting point,complete all as specified and directed.
Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4) complete all as specified and as directed..
PCC 1:2:4 type B2 (using 40 mm graded crushed stone aggregate) as in surafce channel and drains, complete all as specified and directed.
Providing precast cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes, drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles plain face and set in cement mortar 1:6 complete all as specified.
MS TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete, all as specifed and directed.
Reinforced concrete pipes 200mm dia bore, class NP2,laid and jointed complete with coller, complete all as specifed and directed.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm dia bore pipes, complete all as specifed and directed. Note:- Thickness of bed below the barrel of pipes 15 cm and width of bed : Outer diameter of drain pipes (not of sockets/collars) plus 30 cm,
150mm bore, salt glazed stone ware drain pipes laid in trenches and jointed, complete all as specifed and directed.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes, complete all as specifed and directed. Note:- Thickness of bed below the barrel of pipes 15 cm and width of bed : Outer diameter of drain pipes (not of sockets/collars) plus 30 cm.
RCC M-25 (Design Mix) using 20mm graded crushed stone aggregate as in slabs, supported on walls, beams and columns in floor, roofs, landing, balconies, canopies, deck slabs and in shelves and the like etc. including necessary form work, complete all as specifed and directed.
PVC (SWR) 110mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specifed and directed.
Cast iron floor trap 75mm, with grating including jointing to waste pipe complete all as specified and directed.
PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in surface channels and drain complete all as specified and directed.
PVC (SWR) pipes single socketed 110mm dia bore,cut size required as in weep holes, complete all as specifed and directed.
Supply, laying ,jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes, 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 16 Sqmm, 4core including taking down of existing unservicable LT cable complete all as specified and directed.
Removing surplus spoil to not exceeding. 50m and deposited where directed at a level not exceeding 1.50m from the starting point, complete all as specified .
Dry sand for sand cushioning to under ground cable 8cm thick before laying the cable and 15cm thick after laying & streching the cable in trenches, including hand punning and consolidating complete all as specified and directed. Note : For payment purpose punned thickness 18cm shall be measured
Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels, complete all as specified and directed.
GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles, complete all as specified and directed.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed.
Taking down Old/ Unserviceable MCB DBs TPN / Main Switches by disconnection of electric connection including old unserviceable MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed.
Concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLSH insulated and unsheathed heavy duty copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white/ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/Putti or distemper / colour wash with same existing colour surfaces,One light / Exhaust Fan/Ceiling fan & One Bell/buzzer point controlled by one switch6/5 Amp one way single pole. all as specified and directed.
All as per Item No. 162 above here-in-before but for one light point control by two way switches with other Independent Board with 1.5 sqmm PVC insulated unsheathed FRLSH copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed FRLSH copper conductor single core cable (green color) as earth lead or & as directed.
All as per srl item No. 162 above here-in-before but for 3 pin 6/10 Amps socket outlet on independent board.
All as per srl item No. 162 above here-in-before but for 3 pin 6/10 Amps socket outlet on the same board.
All as per Srl item No. 162 above here-in-before but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly.
Modular switch 6/ 10 Amps single pole one way 230 V, 50 Hz, AC, complete all as specified and directed by Engr In charge.
Modular switch 6/ 10 Amps single pole two way 230 V, 50 Hz, AC, complete all as specified and directed by Engr In charge.
Modular switch 16 Amps single pole one way 230 V, 50 Hz, AC, complete all as specified and directed by Engr In charge.
Modular Bell push, flush type, 6/10 amp, 230 V, 50 Hz, AC, complete all as specified and directed.
Modular socket 3 Pin, 06 Amps, flush type 230 V, 50 Hz, AC, complete all as specified and directed.
Modular socket combined 2-in-1, 6 Pin 6/10 & 16 Amps 230 V, 50 Hz, AC , flush type with outer/inner cover complete all as specified and directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round block, complete all as specified and directed.
Call Bell, ding dong 230 volts single pole 50Hz complete all as directed.
White cover plate with frame, 1 module, complete all as specified and directed.
White cover plate with frame, 2 module, complete all as specified and directed.
White cover plate with frame, 3 module, complete all as specified and directed.
White cover plate with frame, 4 module, complete all as specified and directed.
White cover plate with frame, 6 module, complete all as specified and directed.
White cover plate with frame, 8 module, complete all as specified and directed.
Metal flush box 1/2 module, complete all as specified and directed.
Metal flush box 3 module, complete all as specified and directed.
Metal flush box 4 module, complete all as specified and directed.
Metal flush box 6/8 module, complete all as specified and directed.
Sheet metal enclosure, double door, type, for MCCB VTPN DB upto 100 Amps, 4 way vertical type 415 volts with 400 Amps rated busbar and neutral link for MCCB 100 Amps 16 KA , chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Sheet metal enclosure double door type for DBs (when MCB to be used) 12 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Renewal of MCCB Three Pole & Neutral capacity of 100 amps 415 volts rupturing capacity 16 KA complete all as specified and directed.
Renewal of MCB single pole 240 volt any rating from 05 to 32 amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable
Renewal of MCB single pole and neutral 240 volt any rating from 40 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable, complete all as specified and directed.
Sub main wiring with two run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 10 Sqmm, 1100 Volts grade and one run of 10 Sqmm FRLSH PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLSH PVC insulated and 25 mm PVC conduit shall be measured and paid as one unit length,complete all as specified and as directed Note:- Sub main wiring for (For VPTN DB to SPN DB).
Sub main wiring with two run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4 Sqmm, 1100 Volts grade and one run of 4 Sqmm FRLSH PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLSH PVC insulated and 25 mm PVC conduit shall be measured and paid as one unit length,complete all as specified and as directed Note:- Sub main wiring for (For Geyser).
Single pole and neutral enclosure surface mounted 240 volts with 2 pin and earth plug and socket with one single pole MCB 20 Amps with indicator, complete all as specified and directed.
Sub main wiring with two run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 2.5 Sqmm, 1100 Volts grade and one run of 2.5 Sqmm FRLSH PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLSH PVC insulated and 25 mm PVC conduit shall be measured and paid as one unit length,complete all as specified and as directed Note:- Sub main wiring for (For street light).
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Modular electronic step type fan regulator 120 watt 230 volts 50Hz 2 module C/S deluxe type complete all as specified and directed.
Exhaust fan, Plastic body, AC single phase 230/240 volts heavy duty of size 250mm sweep with blades, frame, louvers and all fixing arrangements as all as specified & directed.
Taking down ceiling fan/Exhaust fans (C/F of any size/make), cleaning its dust particles oiling,greasing,one coat of synthetic enamel white spray painting with blade ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge. Note :- (i) The spares like condensor, ball bearing, cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the ceiling fans functional without any cost to the dept.
Taking down Geyser from existing location, cleaning its dust particles, reassemble the same along with all fittings and hanging the same back to its original position including connecting with 2 Pin Earth plug and socket complete all as specified and as directed by Engr-in-Charge. Note:- (i) The spares for geyser like inlet/ outlet PVC Pipe, Anchor Fasteners, bajaj clanta plate etc if found defective/damage deemed to be replaced and make the Geysers functional without any cost to the dept.
Taking down existing prepaid meter & Display unit alongwith conduit pipe dia 25mm qty approx 09 RM, casing caping pipe size 20mm qty approx 2 RM & 6 core control cable (RJ-11) qty approx 11 RM from each qtr and refixing the same back to its original position including connecting the 6 core control cable (RJ-11) from prepaid meter to display unit complete all as specified and as directed.
LED tube light fitting 20W and wall mounted LED Batten with powdered coated aluminium housing & Integrated electronic driver with THD<10% making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one, complete all as specified and directed.
LED tube light fitting 10W and wall mounted LED Batten with powdered coated aluminium housing & Integrated electronic driver with THD<10% making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one, , complete all as specified and directed.
LED tube light fitting 5W Batten LED (Warm white/ white), housing made of extruded PC with lumen O/P should not be less than 100 lum/watt making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one, complete all as specified and directed.
LED building security light fitting 30 Watt, 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
Street light Bracket complete made of GI pipe of 40mm dia, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall, complete all as specified and directed.
Deduction to be made from BOQ for Sch 'A' Part - II (Schedule of credit) Amount of Rs. 13,28,642.00 during AOC. Note: Tenderers shall not quote for this schedule.
M/S VED PARKASH GUPTA
d d builders
M/S Inderjit Sharma and Co.
vijay builders
Mehar Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .