| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹21.3 L+₹51,150 (2.46%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹21.5 L+₹76,035 (3.66%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹23.6 L+₹2.8 L (13.6%)Rejected-Finance 01 MITHAPUR B AREA NAHARPAR BEHIND OF BHANA MILE MITHAPUR MITHAPUR MITHAPUR B AREA NAHARPAR PATNA BIHAR 800001 | PATNA | BIHAR | 800001 | L4 | Rejected-Finance Not become lowest bidder | |
| 5 | L5₹26.8 L+₹6.0 L (28.9%)Rejected-Finance | L5 | Rejected-Finance Not become lowest bidder |
Tender Value
Refer Docs
EMD Value
₹41,800
Closing Date
12 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Major Deepak Kumar
Garrison Engineer Jhansi
SPECIAL REPAIR / REPLACEMENT OF OVERHEAD LINES TO UNDER GROUND CABLE AT VARIOUS PLACES AND OTHER SANCTIONED WORK AT MIL STN NOWGONG AND JHANSI UNDER AGE E/M OF GE JHANSI
2021_MES_435499_3
GE/JHA/TOK/02 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE Jhansi
₹41,800
Yes
24 Jul 2021
25 May 2021
14 Jun 2021
25 May 2021
12 Jun 2021
29 May 2021
60 days
Amount
Material & Labour for Power Cables, Aluminum Stranded Conductor of 185 Sqmm 3.5 core XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provision of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings and testing on completion all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items.
All as per item No. 1.00 here-in-before but of size 70 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 50 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 35 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 25 sqmm, 4 core.
All as per item No. 1.00 here-in-before but of size 16 sqmm, 4 core.
All as per item No. 1.00 here-in-before but of size 10 sqmm, 4 core.
All as per item No. 1.00 here-in-before but of size 10 sqmm, 2 core.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in any type of soil for laying of cables / GI pipe complete all as specified and directed by Engineer-in-Charge.
Supply and spread M-sand in trenches for cushioning of cable complete all as specified and directed by Engineer-in-Charge. (Note: Punned down thickness only shall be measured for the purpose of payment)
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and lay in trenches, un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection in trenches complete all as specified and directed by Engineer-in-Charge.
Material & Labour for cutting of existing hard standing/Road up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below hard standing will be measured and paid under relevant items.
Material and labour for 80mm bore GI pipe light grade laid in trenches / floors or fixed to pole / walls etc with suitable clamps for protection of earth strip / cable complete all as specified and directed by Engineer-in-Charge.
Material and labour for 50mm bore GI pipe light grade laid in trenches / floors or fixed to pole / walls etc with suitable clamps for protection of earth strip / cable complete all as specified and directed by Engineer-in-Charge.
Material and labour for 40mm bore GI pipe light grade laid in trenches / floors or fixed to pole / walls etc with suitable clamps for protection of earth strip / cable complete all as specified and directed by Engineer-in-Charge.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
Design, fabricate, supply, installation, testing and commissioning of outdoor type cubicle panel board compartmentalized suitable for 3 phase 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards(02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1250mm x 1250mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring complete:- (Note: (i) The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
Dismantling/taking down cross arms of MS channel or angle sections etc. from pole/any description Complete all as specified and directed.
Dismantling/taking down of old insulators any type from pole of any size complete all as specified & directed.
Dismantling stay assembly complete. (demolition of concrete, etc. and excavation measured separately)
Dismantling / taking down of old ACSR conductor of any description / size from LT Poles of any size, complete all as specified & directed.
Design, Fabricate, supply, installation and testing of outdoor type cubicle panel board bus bar box with MCCB suitable for 3 phase 4 wire, 50 Hz supply system factory fabricated made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front openable door with locking arrangement complete with powder coat painting and suitable packing material for IP-54 degree of protection and including provision of 40mmx40mmx5mm angle iron base frame of suitable size for mounting the panel board at a height of 450mm above GL and grouted in PCC foundation. The size of panel board shall not be less than 500mm x 500mm x 300mm (outer dimensions) for accommodating and including provision of following switchgears complete:- (i) TPN Aluminium bus bar of 40 x 5 mm provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators suitable for connecting 2 or 3 outgoing cables including provision suitable glands. (ii) MCCB, 63 A, 4 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 No
Supply and fix Thermoplastic cable junction box IP 66/67 “weather proof”, for outdoor installation (with knockouts for cable entry) of size 205mm x 255mm x 112mm with provision of 63Amps rated four pole (3P+N) connector, one single pole MCB of 6 Amps rating mounted on DIN rail, stainless steel cable glands of suitable size for incoming and outgoing cables and PVC gland for copper control cable for light fitting including fixing on steel tubular poles / PCC poles with 20mm x 3mm MS clamps with fixing brackets (02 Nos), nuts, bolts, washers etc duly painted with two coats of aluminium paint over a coat of red oxide primer on steel clamps and brackets etc complete all as specified and directed by Engineer-in-Charge.
Making holes (02 Nos - one near cable junction box and another near street light bracket) on existing steel tubular poles of any type, thickness & height through drilling / gas welding work having smooth and champher edge of hole, for drawing street light control cable through inside of pole complete all as specified and directed by Engineer-in-Charge.
Supply and connect PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts grade, conforming to IS 694, three core, 1.5 sqmm for connecting from junction box to street light fitting complete all as specified and directed by Engineer-in-Charge.
Demolition of Concrete of any description and in any position provided for coping.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping / plinth on pole with necessary form work, finished even and smooth without using extra cement, complete all as specified and directed.
Supply & testing of Metal Top Deep Freezer, 300/320 Liters capacity with corrosion resistant body with high density PUF insulation with R-134a ecofriendly refrigerant, suitable for operation on 230V, 50 Hz, single phase AC supply complete all as specified and directed.
Supply, connect & testing of automatic voltage stabilizer for low and high voltage cut-off, single phase, AC, 50 HZ, 4 Amps rating, suitable for input voltage range 135V - 280V with 2-4 minutes constant delay for Deep Freezer / Water Cooler complete all as specified and directed by Engineer-in-Charge.
Supply & testing of Refrigerator 190 Liters capacity, single door, frost free, minimum 3 star rating, inverter compressor with ecofriendly refrigerant, suitable for working on 230V, 50Hz, AC single phase supply, stabilizer free operation with built-in protection against voltage fluctuation between 135V - 290V complete all as specified and directed by Engineer-in-Charge.
Supply, installation & testing of Electric Water Heater storage type, vertical, 25 Liters capacity, with minimum 3 Star rating, with heating element, PUF insulation, multifunction safety valve, adjustable knob for temp setting and corrosion resistant inner tank and outer body suitable for operating on 230V, 50 Hz, single phase AC supply including hot & cold water PVC connections and mounting on wall with suitable size & No. of anchor bolts complete all as specified and directed by Engineer-in-Charge.
Supply, installation & testing of Electric Water Heater storage type, vertical, 35 Liters capacity, with minimum 3 Star rating, with heating element, PUF insulation, multifunction safety valve, adjustable knob for temp setting and corrosion resistant inner tank and outer body suitable for operating on 230V, 50 Hz, single phase AC supply including hot & cold water PVC connections and mounting on wall with suitable size & No. of anchor bolts complete all as specified and directed by Engineer-in-Charge.
Supply, installation & testing of Electric Water Heater storage type, vertical / horizontal as per site suitability, 100 Liters capacity, with minimum 3 Star rated, with heating element, PUF insulation, multifunction safety valve, adjustable knob for temp setting and corrosion resistant inner tank and outer body suitable for operating on 230V, 50 Hz, single phase AC supply including hot & cold water PVC connections and mounting on wall / floor with suitable size & No. of anchor bolts complete all as specified and directed.
Supply, install and testing of evaporative desert cooler having nominal air flow capacity of 3000 Cum per hour with metallic body made out of minimum 23 SWG GI sheet along with front grill and three side shutters with cooling pads etc and body fitted with heavy duty fan motor, copper wound, 1/7 HP, 1360/1400 RPM, three speed control, single phase, 230V, 50Hz with 450mm fan blades and 18 Watt submersible pump complete with float valve, PVC distribution pipe, control switch complete suitable for desert cooler including connecting cord PVC insulated and PVC sheathed copper conductor cable 3 core, 1.5 sqmm confirming to IS:694 up to 2.50 meters long fitted with plug top 3 pin, 6 Amps ISI marked complete all as specified and directed by Engineer-in-Charge.
Material and labour for Point wiring with 2.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 2.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass / GI screws for mounting switches, sockets etc. for One 16 Amps socket point controlled by one 16 Amps switch complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
2 x 4 sqmm + 1 x 4 sqmm
2 x 6 sqmm + 1 x 6 sqmm
Notes for item No. 37.00 to 38.02: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables to avoid any damage to the structure.
Supply and fix switch piano flush type 16 Amps, one way, 240V, 50Hz complete all as specified and directed.
Supply and fix socket 16A & 6A, 6 pin, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.
Supply and fix modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.
Supply and fix MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge.
Material and labour for GI pipe, 'medium grade' with all fitting such as socket, elbow, bend, tee, reducer, union, nipple etc of size 15 mm bore and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
Material and labour for GI pipe, 'medium grade' with all fitting such as socket, elbow, bend, tee, reducer, union, nipple etc of size 25 mm bore and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
Supply and fix Bib tap, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15mm bore dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix angle valve, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15mm bore dia complete all as specified and directed by Engineer-in-Charge.
Material and labour for Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
Material and labour for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
Material and labour for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Material and labour for Galvanized iron strip 25 x 4mm buried in ground complete all as specified and directed.
Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 40mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply, installation, testing and commissioning of air cooled split type Air conditioner (Cooling and heating type) of 2.0 TR capacity comprising of one indoor and one outdoor unit, wall mounted type, comprise of copper pipe heat exchangers, having non CFC refrigerant, electric driven, 230 volts AC, single Phase, 50 Hz, having either Five Star rating or inverter technology with three star, with and including inlet / outlet copper pipe for refrigerant between indoor & outdoor unit and flexible copper wire of suitable size as recommended by manufacturer, complete all as specified and directed by Engineer-in-Charge. Note : The cost of making hole / opening for passing of inlet / outlet copper pipes and electrical cord and making good of surface as original by plastering / applying putty / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect.
Supply, installation, testing and commissioning of air cooled split type Air conditioner of 2.0 TR capacity comprising of one indoor and one outdoor unit, wall mounted type, comprise of copper pipe heat exchangers, having non CFC refrigerant, electric driven, 230 volts AC, single Phase, 50 Hz, having either Five Star rating or inverter technology with three star, with and including inlet / outlet copper pipe for refrigerant between indoor & outdoor unit and flexible copper wire of suitable size as recommended by manufacturer, complete all as specified and directed by Engineer-in-Charge. Note : The cost of making hole / opening for passing of inlet / outlet copper pipes and electrical cord and making good of surface as original by plastering / applying putty / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect.
Supply, connect & testing of automatic voltage stabilizer, wall mounted type for low and high voltage cut-off, single phase, AC, 50 HZ, 15 Amps rating, suitable for input voltage range 170V - 270V with 3 min ± 20 sec delay for Air Conditioner complete all as specified and directed by Engineer-in-Charge.
Supply and fix three layer rotational moulded polyethylene water storage tank of capacity 500 liters (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and as directed by Engineer-in-Charge.
M/S Kumar Contractors
ROHIT ENTERPRISES
ADARSH ENTERPRISES
M/s Ratan Mechanical Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .