Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAdmitted-Finance | ₹1.5 L | L1 | Admitted-Finance |
| 2 | L2₹1.7 LAdmitted-Finance | ₹1.7 L | L2 | Admitted-Finance |
| 3 | L3₹1.9 LAdmitted-Finance MEERUT UTTAR PRADESH 250110 INDIA UDYAM UP 56 0008622 | MEERUT | UTTAR PRADESH | 250110 | ₹1.9 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not fullfil PQR |
| Sl No | Description | Qty | Unit | SHIVAM INDUSTRIES L1 | M/SNITYA INTERPRISES L2 | Hi-tech power transmission L3 |
|---|---|---|---|---|---|---|
| 1.00Details of Work/Supply. | ||||||
| 1.01 | Complete dismantling work of all accessories of damaged 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) including Bushings, Oil pipeline from conservator tank to main tank, oil pipeline to OLTC and conservator tank and all earthing strips at 132KV S/S SARILA under ETD Hamirpur. | 1 | Job | 2,500 ₹2,500 | 1,500 ₹1,500 | 3,000 ₹3,000 |
| 1.02 | Safe shifting and loading work of 01 no. damaged 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) and 02 nos. Transformer oil filled oil drums with the help of Hydra/Crane arranged by contractor at his own cost in Loader arranged by contractor at his own cost at 132KV S/S Sarila under ETD Hamirpur. | 1 | Job | 2,000 ₹2,000 | 5,000 ₹5,000 | 20,000 ₹20,000 |
| 1.03 | Safe Carriage of 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) and 02 nos. Transformer oil filled oil drums by Loader arranged by contractor at his own cost from 132KV S/S Sarila to workshop designated by the contractor.( Approx. Distance- 150 Km one way). | 1 | Job | 22,000 ₹22,000 | 7,000 ₹7,000 | 20,000 ₹20,000 |
| 1.04 | Safe Unloading work of 01 no. 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) and 02 nos. Trasformer oil filled oil drums with the help of Hydra/Crane means, arranged by contractor at his own cost at appropriate place at workshop designated by contractor. | 1 | Job | 2,000 ₹2,000 | 2,000 ₹2,000 | 2,000 ₹2,000 |
| 1.05 | Complete Drain-out of Transformer oil from the damaged 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) to empty drums provided by the department free of cost as per actual requirement at 132KV S/S Sarila under ETD Hamirpur | 1 | Job | 2,000 ₹2,000 | 5,000 ₹5,000 | 3,000 ₹3,000 |
| 1.06 | Complete Repairing work of Copper windings of R, Y and B phase of damaged 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) by opening of Top cover of station ransformer including proper fitting of top cover and windings of above phases to complete the job if any including all other associated works satisfactorily at workshop, designated by contractor. | 1 | Job | 15,000 ₹15,000 | 10,000 ₹10,000 | 3,000 ₹3,000 |
| 1.07 | Replacement of burnt & damaged H.T Coils with new, complete with inulation/varnishing after vacuum ipregnation. Difference of conductor value of new HV/LV leg coil complete with insulation, varnishing and baking of coil assembly etc. and burns/damaged HV/LV leg coil to be retained by the contractor. | 200 | Kg | 200 ₹40,000 | 200 ₹40,000 | 450 ₹90,000 |
| 1.08 | Winding work of the above fresh conductor around the T/F core assembly in main tank of 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make). | 200 | Kg | 120 ₹24,000 | 350 ₹70,000 | 85 ₹17,000 |
| 1.09 | Re-strengthening work of major & minor insulation between coils, core & transformer body and improving of megger values as per department standards and technical specifications & standard norms of 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make). | 2 | Job | 5,000 ₹10,000 | 3,000 ₹6,000 | 3,000 ₹6,000 |
Updated dates
Tender Value
₹2.4 L
EMD Value
₹3,000
Closing Date
10 Feb 2026, 3:00 pmClosed
SE ETC Banda
SE ETC Office, 220 KV S/S Tindwari Road, Banda
WORK FOR REPAIRING OF DAMAGED 250 KVA (33/0.4 KV) STATION TRANSFORMER ALONGWITH OTHER ASSOCIATED WORKS AT 132 KV SUB STATION SARILA UNDER ETD HAMIRPUR.
2025_UPTCL_1103132_1
T-55/ETC(B)/2025-26
Open Tender
Electrical Works
60 days
Banda
As per tender document.
2 documents required · 2 mandatory
₹590
As per NIT
₹3,000
10 Apr 2026
31 Dec 2025
11 Feb 2026
31 Dec 2025
10 Feb 2026
31 Dec 2025
Details of Work/Supply.
Complete dismantling work of all accessories of damaged 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) including Bushings, Oil pipeline from conservator tank to main tank, oil pipeline to OLTC and conservator tank and all earthing strips at 132KV S/S SARILA under ETD Hamirpur.
Safe shifting and loading work of 01 no. damaged 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) and 02 nos. Transformer oil filled oil drums with the help of Hydra/Crane arranged by contractor at his own cost in Loader arranged by contractor at his own cost at 132KV S/S Sarila under ETD Hamirpur.
Safe Carriage of 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) and 02 nos. Transformer oil filled oil drums by Loader arranged by contractor at his own cost from 132KV S/S Sarila to workshop designated by the contractor.( Approx. Distance- 150 Km one way).
Safe Unloading work of 01 no. 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) and 02 nos. Trasformer oil filled oil drums with the help of Hydra/Crane means, arranged by contractor at his own cost at appropriate place at workshop designated by contractor.
Complete Drain-out of Transformer oil from the damaged 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) to empty drums provided by the department free of cost as per actual requirement at 132KV S/S Sarila under ETD Hamirpur
Complete Repairing work of Copper windings of R, Y and B phase of damaged 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) by opening of Top cover of station ransformer including proper fitting of top cover and windings of above phases to complete the job if any including all other associated works satisfactorily at workshop, designated by contractor.
Replacement of burnt & damaged H.T Coils with new, complete with inulation/varnishing after vacuum ipregnation. Difference of conductor value of new HV/LV leg coil complete with insulation, varnishing and baking of coil assembly etc. and burns/damaged HV/LV leg coil to be retained by the contractor.
Winding work of the above fresh conductor around the T/F core assembly in main tank of 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make).
Re-strengthening work of major & minor insulation between coils, core & transformer body and improving of megger values as per department standards and technical specifications & standard norms of 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make).
Painting work of the Transformer inside with Zinc Chromate Paint & outside with two coats of Smoke Grey colour synthetic enamel paint.
Safe shifting and loading work of 01 no. damaged 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) and 02 nos. Transformer oil filled oil drums with the help of Hydra/Crane arranged by contractor at his own cost in Loader arranged by contractor at his own cost at 132KV S/S Sarila under ETD Hamirpur.
Safe Carriage of 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) and 02 nos. Transformer oil filled oil drums by Loader arranged by contractor at his own cost from 132KV S/S Sarila to workshop designated by the contractor.( Approx. Distance- 150 Km one way).
Safe Unloading work of 01 no. 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) and 02 nos. Trasformer oil filled oil drums with the help of Hydra/Crane means, arranged by contractor at his own cost at appropriate place at workshop designated by contractor.
Complete Erection work of all acessories of Repaired 250KVA, 33/0.415KV Station Transformer (Associated Electricals Pvt. Ltd./2015 Make) by erecting conservator tank, HV, LV and Neutral bushings, connecting oil pipelines etc. to complete the job including earthing body of transformer and all other associated works satisfactorily at 132KV S/S Sarila under ETD Hamirpur.
Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_2034271.pdf
techsummary_2034271.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
TenderDocumentT55.pdf
Tender Documents • 0.86 MB
BOQ_2034271.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid