Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC H NO 257 1ST FLOOR KAMALA NEHRU NAGAR BATHINDA PB | BATHINDA | BATHINDA | PUNJAB | L1 | Accepted-AOC Accept | |
| 2 | L2₹48.1 L+₹1.4 L (3.03%)Rejected-Finance | L2 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | GAYATRI ENTERPRISES L2 | SUBHASH ARORA CONSTRUCTION CO L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer in charge. | 742 | Sqm | 100 ₹74,200 | 70 ₹51,940 Lowest |
| 2.00 | M&L for Vitrified ceramic tiles (dark shade) 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed by Engineer in charge | 410 | Sqm | 1,600 ₹6,56,000 Lowest | 1,990 ₹8,15,900 |
| 3.00 | M&L for Coloured Non-skid Ceramic tiles 7 to 8 mm thick exc. 0.06 sqm but n.exc 0.11sqm area of each tiles in floor/ steps etc set and jointed in neat cement slurry and pointed in coloured cement to match as in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed by Engineer in charge. | 24 | Sqm | 1,550 ₹37,200 Lowest | 1,600 ₹38,400 |
| 4.00 | M&L for Glazed Ceramic tiles 450x300x 8-10 mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing in cement mortar (1:3) complete all as specified and as directed by Engineer in charge. | 290 | Sqm | 1,500 ₹4,35,000 Lowest | 1,550 ₹4,49,500 |
| 5.00 | Dismantling of old stone slab in floors etc not exc 25mm complete all as specified and as directed by Engineer in charge. | 2.2 | X sqm | 500 ₹1,100 | 50 ₹110 Lowest |
| 6.00 | M&L Granite (of any type) 16 to 20 mm thick machine cut fixed on floor,skirting,dado slab,window cill etc, bedded & jointed with grey cement slurry & pointed with white cement with admixure of pigment to match the shade of granite stone including cutting, moulding & polishing over and including 20 mm thick screed in CM (1:3) complete all as specified and as directed by Engineer in charge. | 22 | Sqm | 7,000 ₹1,54,000 | 6,900 ₹1,51,800 Lowest |
| 7.00 | M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engineer in charge. | 25 | RM | 1,000 ₹25,000 | 200 ₹5,000 Lowest |
| 8.00 | Demolition of precast concrete block walling built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed by Engineer in charge. | 3 | Cum | 800 ₹2,400 | 500 ₹1,500 Lowest |
| 9.00 | M&L precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and as directed by Engineer in charge. | 3 | Cum | 11,500 ₹34,500 | 11,000 ₹33,000 Lowest |
| 10.00 | Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer in charge. | 110 | Sqm | 100 ₹11,000 | 50 ₹5,500 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Oct 2024, 6:00 pmClosed
GE Minniebay, Port Blair
GE, Minniebay, Junglighat (PO), Port Blair -744103
SPECIAL REPAIR TO P-165 (BLOCK C) INHS DHANVANTRI UNDER GE MINNIEBAY, PORT BLAIR
2024_MES_666101_2
8442/E8
Open Tender
Civil Works
Item Rate
180 days
GE Minniebay, Port Blair
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE Minniebay
₹90,000
23 Aug 2025
3 Oct 2024
31 Oct 2024
3 Oct 2024
29 Oct 2024
10 Oct 2024
Amount
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer in charge.
M&L for Vitrified ceramic tiles (dark shade) 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed by Engineer in charge
M&L for Coloured Non-skid Ceramic tiles 7 to 8 mm thick exc. 0.06 sqm but n.exc 0.11sqm area of each tiles in floor/ steps etc set and jointed in neat cement slurry and pointed in coloured cement to match as in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed by Engineer in charge.
M&L for Glazed Ceramic tiles 450x300x 8-10 mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing in cement mortar (1:3) complete all as specified and as directed by Engineer in charge.
Dismantling of old stone slab in floors etc not exc 25mm complete all as specified and as directed by Engineer in charge.
M&L Granite (of any type) 16 to 20 mm thick machine cut fixed on floor,skirting,dado slab,window cill etc, bedded & jointed with grey cement slurry & pointed with white cement with admixure of pigment to match the shade of granite stone including cutting, moulding & polishing over and including 20 mm thick screed in CM (1:3) complete all as specified and as directed by Engineer in charge.
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engineer in charge.
Demolition of precast concrete block walling built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed by Engineer in charge.
M&L precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and as directed by Engineer in charge.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer in charge.
M & L for rendering to concrete or block masonry surfaces or surfaces other than fair faces of brick surfaces, 10mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer in charge
M & L rendering 5mm thick in CM (1:3) on ceiling surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer in charge
M & L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 (Total 15 mm thick) on concrete or brick masonry surfaces including mixing water proofing compound as per manufacurers instructions and finishing the top surface even and fair complete all as specified and as directed by Engineer in charge. Note: Water proofing compound will be measured and paid separately.
Supply only Integral water proofing compound.
M & L Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed by Engineer in charge.
M&L preparing newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge. Make : Asian paints Tractor suprema
M&L preparing newly plastered surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge. Make : Asian paints tractor suprema
M & L for complete removal of existing treatment on wall & finishing the surface and applying two coats of oil bound distemper along with primer complete all as specified and as directed by Engineer in charge. Make : Asian Paints tractor suprema
M & L for complete removal of existing treatment on ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge. Make : Asian Paints tractor suprema
Taking up or down 20 mm bore tubing and connections and removing off the site complete all as specified and as directed by Engineer in charge.
Taking up or down 25 mm bore tubing and connections and removing off the site complete all as specified and as directed by Engineer in charge.
Supply and laying of CPVC pipes 20 mm dia outer bore SDR 11 &plain CPVC SDR 11with all special fittings on walls /ceilings or laying in floors complete all as specified and as directed by Engineer in charge.
Supply and laying of CPVC pipes 25mm dia outer bore SDR 11 &plain CPVC SDR 11 with all special fittings on walls /ceilings or laying in floors complete all as specified and as directed by Engineer in charge.
S&F 20 mm outer dia CPVC Male Brass Threaded Adaptor complete all as specified and as directed by Engineer in charge.
S&F 25 mm outer dia CPVC Male Brass Threaded Adaptor complete all as specified and as directed by Engineer in charge.
S&F 20 mm outer dia CPVC pipes brass Elbow complete all as specified and as directed by Engineer in charge.
S&F 20mm outer dia CPVC pipes brass Elbow (3/4 X1/2) complete all as specified and as directed by Engineer in charge.
S&F 20mm outer dia CPVC female brass adaptor (FTA/FBTA) complete all as specified and as directed by Engineer in charge.
S&F 25 mm outer dia CPVC female brass adaptor (FTA/FBTA) complete all as specified and as directed by Engineer in charge.
S&F 20 mm outer dia Brass Tee complete all as specified and as directed by Engineer in charge.
S&F 25 mm outer dia tank Adaptor complete all as specified and as directed by Engineer in charge.
S&F 20mm outer dia union complete all as specified and as directed by Engineer in charge.
S&F 25 mm outer dia union complete all as specified and as directed by Engineer in charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer in charge.
M&L Reinforced Cement Concrete 1:2:4 nominal mix for column ,pillars,posts,struts,piers,columns and stanchions etc including formwork complete all as specified and as directed by Engineer in charge.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required incl cranking and hooking ends and binding with MS wire (annealed) of dia not less than 0.90mm complete all as specified and as directed by Engineer in charge.
M&L for TMT bars , but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required incl cranking and hooking ends and binding with MS wire (annealed) of dia not less than 0.90mm complete all as specified and as directed by Engineer in charge.
S&F 25mm Ball brass valve high pressure of polyethylene float and fly nut complete screwed for iron pipe and fixed, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule etc and fixed complete all as specified and as directed by Engineer in charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer in charge.
S&F Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for preparation of old steel surfaces exc. 10cm width and girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer in charge.
Taking down chowkats or frames not exceeding 1.5 sq.m each with shutters without taking off shutters from the frames and removing off site etc complete all as specified and as directed by Engineer in Charge.
Taking down chowkats or frames exceeding 1.5 sq.m and not exceeding 4 sqm each with shutters without taking off shutters from the frames and removing off site etc complete all as specified and as directed by Engineer in Charge.
S&F solid Factory made PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube in opeing, complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick with single side prelam PVC sheet used instead of plain colour PVC sheet and stile & rails having one side feathered edge and on other side 10 mm 90 degree bent edge consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stilesand plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
S & F aluminium Section ( Powder coated not less than 50 microns) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed by Engineer in charge.
S&F aluminium section ( Powder coated not less than 50 microns) frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed by Engineer in charge.
S&F aluminium Section ( Powder coated not less than 50 microns) door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips,ruber neoprene packing,handles 2 Nos in each door ,hinges ,anodised aluminium snap beading screws complete all as specified and as directed by Engineer in charge.
Fixing only in repairs anodised aluminium window and ventilator shutters, side hung type with or without sash bars, aluminium sections weighing 0.55 kg/m and thickness of section not less than 1.6 mm including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed by Engineer in Charge.
Supply and fixing in repair stainless steel friction stay hinges 200 x19 x1.90 mm of standard size complete all as specified and as directed by Engineer in charge.
Supply only 4mm Plain sheet glass ordinary quality ,in square exc 0.5 sqm each complete all as specified and as directed by Engineer in charge.
Supply only aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer in charge.
S & F in repair aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer in charge.
Supply only Figured glass 4mm,pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and as directed by Engineer in charge.
S&F Aluminium anodised sliding door bolts 250 mm long with hasp and staple complete all as specified and as directed by Engineer in charge.
S & F 100mm length Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 including screws complete all as specified and as directed by Engineer in charge.
S & F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed by Engineer in charge.
S & F 18 to 20mm thick prelaminated MDF panels of interior grade type-II of approved shade for kitchen cabin/wardrobe/wall panelling fixing with necessary fitting like keku fitting,spring clip,hanger plate,modular hinge/clip,push fix or stud fitting as per manufacturers instructions complete all as specified and as directed by Engineer in charge.
S & F fancy type curtain Rod decorative type , stainless steel,chromium plated 25 mm dia with stops, rollers including brackets etc complete all as specified and as directed by Engineer in charge.
S&F stainless steel sink with drainage board made out of 1.00 mm thick sheet with plug, washers, Ms angle cantilever brackets for suitable size and connecting union to pipe of overall size 1140 mm x 500 mm and bowl size 510mm x 400 mm x 190 mm complete all as specified and as directed by Engineer in charge.
S&F Vitreous china wash hand basin, white flat back size 550x400 mm including brackets, 32mm dia PVC waste pipe etc with long screwed shanks and fly nuts complete all as specified and as directed by Engineer in Charge.
Supply only 32 mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer in charge.
Supply only 32 mm (Dia of discharge pipe) Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm- 45gms/40mm-60 gms) complete all as specified and as directed by Engineer in charge.
S & F Bib Taps with flange, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and as directed by Engineer in charge.
S&F stop valves cast copper alloy chromium plated with long shank and cup fancy type screwed down high pressure screwed both ends for pipe or union fixed for 15mm bore,including necessary cutting and making good wall or floor tiling to match existing(tiles to be paid supplied only rates) etc complete all as specified and as directed by Engineer in charge.
S & F two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and as directed by Engineer in charge.
S & F bib Taps, long boby with flange cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and as directed by Engineer in charge.
S&F stainless steel Towel ring square with round flangecomplete all as specified and as directed by Engineer in charge. make & Model No: Jaquar ACN-1121N
S&F brass chromium plated telescopic Hand shower(Health Faucet) (ABS Body) with 1 Meter long Easy Flex Tube in Chrome Finish& wall Hook complete all as specified and as directed by Engineer in charge.
S & F soap Dish,brass chromium plated of approximate size 160 x 160 x 90 mm with screws complete all as specified and as directed by Engineer in charge.
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long of approved quality complete all as specified and as directed by Engineer in charge.
S & F Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed by Engineer in charge.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white including Plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer in charge.
S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe of Make Slimline or Cera or equivalent make complete all as specified and as directed by Engineer in charge.
S&F in repairs PVC flexible connection with PTMT nuts, of 15mm dia and 600mm long with brass unions and rubber washers on either side, for connecting water supply line to WHB, flush tank ,Geyser etc, complete all as specified and as directed by Engineer in charge.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement with SS grating 100mm bore complete all as specified and as directed by Engineer in charge.
Demolition and breaking up drain pipes of size 75/100 mm dia (Salt glazed ware, AC or Reinforced concrete, PVC (SWR) set in cement mortar complete all as specified and as directed by Engineer in charge.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in down pipes complete all as specified and as directed by Engineer in charge.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed by Engineer in charge.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed by Engineer in charge.
M &L for Stack clamps for 100 mm dia bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed by Engineer in charge.
S&F 110mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed by Engineer in charge.
S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed by Engineer in charge.
Supply and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed by Engineer in charge.
Removing loose and broken concrete/ masonary surface by chiseling/ mechanically etc from the roof slab, coloumn, beam and similar structural members cutting edges, cleaning the dismantled portion with wire brush etc to make the reinforcement naked and remove dust, dirt and other foreign particle etc and removig to debries 50 Mtr from site complete all as specified and as directed by Engineer in charge.
M&L for providing and applying rust remover to the exposed corroded reinforcement as per manufacturer's instruction including removing of concrete all around reinforcement by manual methods such as hammering the rebar, using wire brushes, salt paper, chiseling, etc (if left uncleared) including applying two coats of anticorrosive primer over dry steel surfaces after allowing due time for removal of rust complete as directed by Engineer-In-Charge. Note : The circumferential area around rusted bars along the length shall be measured and paid under this quoted item.
M/L for applying one coat of epoxy bonding coat as per manufacturer's instruction to bind with old concrete / wall surfaces of soffit of slab, column, beam and similar structural members for new cement surface complete all as specified and directed by Engineer-in-Charge.
M&L for rendering the identified RCC surfaces with 15mm average thick cement mortar (1:3) on gunited surface by using POLYMER MODIFIED MORTAR in single layer of relevant proportion and weight of polymer, cement and filler material as per approved make, blended to a required consistency, applying, finishing and curing as per manufacturer's instructions including necessary scaffolding, formwork complete all as specified and as directed by Engr-in-Charge. NOTE FOR ITEM NO.84 to 86 : (i) The successful contractor shall execute the structural repair and rehabilitation work through the Manufacturer's authorised applicator only and the copy of the agreement/certification for the same shall be submitted to the Accepting officer for approval before the execution of the work. An amount of 2.5 % of the quoted amount subject to a minimum Rs.50,000/- shall be retained against security deposit against the structural repair work under the respective items and gurantee bond for the same shall be also submitted in Non Judicial stamp paper duly notarized along with the deposit amount. The work is to be executed of height (G+3) with necessary scaffolding and contractor shall quoted accordingly.
M & L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by Engineer in charge. Make : Asian paints Apex suprema
Complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces. all as directed by the Engineer-in-charge and as per manufacturers instructions complete all as specified and as directed by Engineer in charge. Make : Asian paints Apex suprema
Taking down carefully existing aluminium point wiring (light, fan , socket or power) complete fittings fixture such as switches Ceiling roses, pendents,regulators, sockets etc to be measured separately)unscrewing from Board/outlet boxes, fittings & fixtures such as switches, sockets, ceiling rose lamp holder tube/ceiling fitting, bulk head fittings, tube lights & regulator etc and making good disturbed surfaces of walls, floors etc complete all as specified and as directed by Engineer in charge.
Taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and as directed by Engineer in charge.
Taking down unserviceable main switches ,DBs and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and as directed by Engineer in charge.
M&L for point wiring with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit medium grade/ PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc) and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and as directed by Engr-in-Charge. (In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) GI metal flush box minimum 1.6 mm thickness and Modular cover plate with frame of any module complete. (b) Proper colour coding is to be followed as per IS Specification. (c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement. (d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment. (e) Cutting chasis in wall/floor beam to be concealed conduit and making good the disturbed surface is deemed to be included in the quoted rate. (f) Contractor shall submit proposed internal wiring drg with fittings, fixtures and sockets etc., complete for approval of GE before commencement of work.
One light point controlled by one one way switch complete all as specified and as directed by Engineer in charge.
One ceiling fan/exhaust fan point controlled by one switch complete all as specified and as directed by Engineer in charge.
One 3 pin socket outlet 5 Amps on the same board with other switches complete all as specified and as directed by Engineer in charge.
One 3 pin socket outlet 5 Amps independent complete all as specified and as directed by Engineer in charge.
All as per serial item No.95 above here-in-before but for 15/16 Amps socket out let independent with 4 sqmm copper conductor complete all as specified and as directed by Engineer in charge.
S&F Modular switch one way, 6 Amps, 1 module, 240 volts complete all as specified and as directed by Engineer in charge.
S&F Modular switch one way, 16 Amps, 1 module, 240 volts complete all as specified and as directed by Engineer in charge.
S&F Modular socket, 2/3 pin, 6 amps, 2 module complete all as specified and as directed by Engineer in charge.
S&F Modular socket, 2/3 pin, 6/16 amps, 2 module complete all as specified and as directed by Engineer in charge.
S&F Ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed by Engineer in charge.
M & L for submain wiring with four single core PVC insulated unsheathed multistranded copper conductor cable of size 10 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 10 Sqmm (FRLSH) as earth lead in and including concealed/fixed on wall & Ceiling with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification including taking down unserviceable submain wiring complete all as specified and as directed by Engineer in charge. Note : (i) Five run of cable with one run of PVC conduit/PVC casing and caping will be measured as one length.
M & L for submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable of size 6 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 6 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification including taking down unserviceable submain wiring complete all as specified and as directed by Engineer in charge. Note : (i) Three run of cable with one run of PVC conduit/PVC casing and caping will be measured as one length. (ii) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement. (iii) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment (iv) Contractor shall submit proposed submain wiring drawing complete for approval of GE before commencement of work.
All as per item No 103 here-in-before but with 4.0 sqmm cable complete all as specified and as directed by Engineer in charge.
All as per item No 103 here-in-before but with 2.5 sqmm cable complete all as specified and as directed by Engineer in charge.
All as per Item No 103 here-in-before but with 1.5 sqmm cable complete all as specified and as directed by Engineer in charge.
S&F in repair LED lights fitting 20W, 2000lm, CDL, surge protection of 2 KV, 4 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer in charge.
S&F in repair LED 20W inverter batten type (For stair case lighting) fitting 4 feet long aluminium extruded housing, charging time 10-12 Hrs with 04 Hrs backup,IP-20 ,rated voltage 230 V, 50 Hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer in charge.
S&F in repair LED lights fitting 10W, 2000lm, CDL, surge protection of 2 KV, 4 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer in charge.
S&F in repair LED luminaire 600mm X 600mm, 40 watt, 220V AC, 100 lm/watt, 6500K, IP 20, recessed type with high efficiency PMMA diffuser soft glare free light complere with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer in charge.
Note for item No 108 to 110 : (i) Driver efficiency more than 85% (Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.0 KV & above as per IEC standard (viii) working humidity 95%RH (ix) Life 50000 Hrs at 70% lumes (x) CRI more than 80 (xi) Working temp -10 degree to 50 degree C (xii) Heat Sink extruded aluminum (xiii) junction temperature 85 degree C (xiv) Body of fitting Extruded Aluminum (xv) impact code Min IK 03 or more ( xvi) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xvii) LM 80 report from LED manufacturer (xviii) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xviiii) IP-20 .(xx) Test certificates to be submitted before commencement of work/ claiming for payment .(xxi) Warranty certificate for minimum 2 years to be submitted from OEM.
S&F Ceiling fan 1200mm sweep with blades, suitable BLDC remote electronic regulator as per OEM design, down rods and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, 5 star rated, equipped with brushless direct current motor (BLDC) of wattage < 28W including provision of cable from ceiling rose/connector to fan including taking down old unserviceable ceiling fan and deposited to MES store yard complete all as specified and as directed by Engineer in charge.
S&F heavy duty exhaust fan metal body, AC, single phase, 230V, 450mm sweep complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of exhaust fan including making good disturbed surface with existing wall colour and provision of cable from ceiling rose/connector to fan complete all as specified and as directed by Engineer in charge.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 HZ, Copper winding of sweep 200mm and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of exhaust fan including making good disturbed surface with existing wall colour and provision of cable from ceiling rose/connector to fan complete all as specified and as directed by Engineer in charge.
S&F Air circulator wall fan heavy duty 450mm, single phase, 230V shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of air circulator fan including making good disturbed surface with existing wall colour and provision of cable from ceiling rose/connector to fan complete all as specified and as directed by Engineer in charge.
S&F Industrial plug & socket 63 Amps, 4 Pole, IK-08 inlcuding metal plug and blank plate complete all as specified and as directed by Engineer in charge.
S&F Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed by Engineer in charge.
S&F MCB DB's SPN 8 way, IP-54, IK-09 double door, sheet metal enclosure, 240V, 100 amps rated busbar including suitable size of copper ferrules for fixing of cable complete all as specified and as directed by Engineer in charge.
S&F MCB DB's SPN 4 way, IP-54, IK-09 double door, sheet metal enclosure, 240V, 100 amps rated busbar including suitable size of copper ferrules for fixing of cable complete all as specified and as directed by Engineer in charge.
S&F MCCB DB VTPN 4 way IP-54, IK-09 made of sheet steel phos phatised, powder painted with bus bar 200A, neutral link, earth bar and Din rail 415 Volts with double door, suitable for MCCB 4 Pole 100-160 Amps as incomer and MCB Single Pole as outgoing complete all as specified and as directed by Engineer in charge. Note for item srl No 117 to 119: (i) MCCB and MCB will be measured and paid separately. (ii) The cost for flushing of Distribution box in any type of wall and making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate
Supply & fixing MCCB 100-160 Amps, thermal adjustable, 25 KA , ICS = 100% ICU, AC 415 Volts, four pole including providing aluminium lugs for incoming and out going cables complete all as specified and as directed by Engineer in charge.
Supply & fixing MCB TP 'C' curve, 415 volts, 63 amps, with rupturing capacity 10 KA, including providing copper lugs for incoming and out going cables complete all as specified and as directed by Engineer in charge.
Supply & fixing MCB TPN 'C' curve, 415 volts, 40 to 100 amps, with rupturing capacity 10 KA, including providing copper lugs for incoming and out going cables complete all as specified and as directed by Engineer in charge.
Supply & fixing MCB SPN 'C' curve ,240 volts, 6 to 32 amps, with rupturing capacity 10 KA, including providing copper lugs for incoming and out going cables complete all as specified and as directed by Engineer in charge.
Supply & fixing MCB single pole 'C' 240 volts, 6 to 32 amps, with rupturing capacity 10 KA, including providing copper lugs for incoming and out going cables complete all as specified and as directed by Engineer in charge.
Supply, installing, testing and commissioning of LT feeder pillar box, factory made indoor type, fabricated out of 2.00 mm thick CRCA sheet, wall mounting, dust and vermine proof, cable alley at side entry suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-43 protection, with separate hinge door for each compartment for incoming and outgoing switchgears/ACB/MCCB etc with locking arrangement, including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect and including PCC work and provn of the following and including dismantling old LT panels complete all as specified and as directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core including taking down old unserviceable cable complete all as specified and as directed by Engineer in charge. Note : (i) The rates shall be inclusive of cable lugs at both ends of cable. (ii) Joint kit if required shall be measured and paid separately.
All as per item No 126 here-in-before but aluminium conductor of size 95 sq.mm x 3 1/2 core complete all as specified and as directed by Engineer in charge.
All as per item No 126 here-in-before but aluminium conductor of size 70 sq.mm x 3 1/2 core complete all as specified and as directed by Engineer in charge.
S&F Double wall corrugated HDPE pipe ISI marked of size inner dia 63mm including specials such as couplers, bends with smooth internal and corrugated external surface for non presuure under ground cable etc., including GI clamps complete all as specified and as directed by Engineer in charge.
S&F Double wall corrugated HDPE pipe ISI marked of size inner dia 50mm including specials such as couplers, bends with smooth internal and corrugated external surface for non presuure under ground cable etc., including GI clamps complete all as specified and as directed by Engineer in charge.
Supply and fixing cable jointing kit for 1.1 KV grade for cable termination, heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 - 185 sqmm complete all as specified and as directed by Engineer in charge.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth strip 32x6mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I complete all as specified and as directed by Engineer in charge Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit and test point complete. (iii) Cost of PVC insulated unsheathed copper cable of size 10 sqmm with suitable size of PVC conduit from test point to incomer DB of bldg shall be deemed to be included in the rate quoted for this item.
GAYATRI ENTERPRISES (BID ID -3142300)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .