Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹82.2 L
EMD Value
₹1.5 L
Closing Date
20 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JABALPUR
HQ COMMANDER WORKS ENGINEER, SUPPLY MARG, P B NO. 54, JABALPUR - 482001
REPAIR AND MAINTENANCE OF CI/DI/GI PIPE LINE IN AREA OF AGE E/M (W/S) AND REPAIR AND MAINT OF WATER SUPPLY INSTALLATIONS, RELATED DISTRIBUTION SYSTEM AND ALLIED WORK OF AGE E/M (W) UNDER GE (W) JABALPUR
2025_MES_740773_1
81149/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
JABALPUR
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (WEST) JABALPUR
₹1.5 L
Yes
17 Dec 2025
21 Nov 2025
27 Dec 2025
21 Nov 2025
20 Dec 2025
13 Dec 2025
21 Nov 2025 - 12 Dec 2025
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm with excavated soil complete all as specified and directed.
Removing excavated material soils, not exc 50m and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
S & F in repair gate / globe valves cast copper alloy screwed both end down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed bore of following size:-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Repair to existing cast iron pipe line in position by cutting of existing cast iron pipe line in position of required sizes for insertion of new tees branches, repairs to existing lines etc complete of the following bores:-
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
M&L Rubber gasket tyton joints suitable for spigot and socket cast iron pipe and fittings of following size complete.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
Note:. Excavation will be measured and paid seprately.
80 mm bore.
100 mm bore.
150 mm bore
200 mm bore.
250 mm bore.
Note. Excavation/Earthwork will be measured and paid seprately.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
Note. Excavation will be measured and paid seprately.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
M&L Fittings for spigot socketed cast iron pipes 80 to 300 mm bore such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, single branch, `Y' junction, double branch, cross (all sockets or socket and spigot), collars, caps ,plugs and JP/D Joint complete all as specified and directed by Engr-in-charge..
S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410-W (Gde-E-250) quality-complete all as specified and directed.
80mm/100mm bore
150mm /200 mm bore
Roller assembly (PK-4)
Pump tube (PK-5)
Weighted suction line strainer 3/8'
3/8" white suction / discharge tube
Check valve duckbill only (PK-5)
Connecting nut 3/8"
Connecting nut 3/8" with adapter (PK-5)
GI fitting for Doser including gate valve of 15 mm dia
NRV suitable for decrin Dozer
UPVC pipe of 15 mm dia
(a) 80 mm dia
(b) 100 mm Dia
(c) 150 mm Dia
(d) 200 mm Dia
Material & labour for cleaning away all grass vegetation, scalping shrubs bushes under growth roots and trees upto zero level not exceeding 30 cm girth and removing rubbish upto distance of 50 mtr out the periphery of area under cleanness complete with tractor/JCB plants all as specified and directed.
(a) 63 Amps, 415 Volts
(b) 100 Amps, 415 Volts
(c) 160 Amps, 415 Volts
(d) 250 Amps, 415 Volts
(e) 400 Amps, 415 Volts
UPVC pipe of 15 mm dia
Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core including taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all asspecified & directed.
Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core including taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all asspecified & directed.
Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core including taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all asspecified & directed.
Excavation in trenches not exceeding 1.5m deep & not exceeding 1.5m wide or area not exceeding 10 Sqm on plan, in Soft and loose soil and getting out for foundation, trenches or laying of electric cable or pipes complete all as specified & directed.
Excavation in trenches exceeding 1.5m deep & not exceeding 3.0 m wide or area not exceeding 10 Sqm on plan, in Soft and loose soil and getting out for foundation, trenches or laying
of electric cable or pipes complete all as specified & directed.
M & L for Sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 6 sqmm drawn through suitable size of non-metallic PVC conduit with one run of 6 sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/recessed as required, including connecting up complete all as specified and directed. NOTE:- Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one unit.
M & L for Sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 10 sqmm drawn through suitable size of non-metallic PVC conduit with one run of 10 sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/recessed as required, including connecting up complete all as specified and directed. NOTE:- Three runs of 10 sqmm cable and one run of PVC conduit shall be measured as one unit.
S&F in repairs PVC Insulated and PVC sheathed Industrial 3 Core Flat Submersible cable 6 sqmm with bare bunched copper conductor for submersible pump motor with voltage grade 1100 volts as per IS 694/1990 including jointing connecting with submersible motor to starter including removing old submersible cable complete all as specified and directed.
S&F in repairs PVC Insulated and PVC sheathed Industrial 3 Core Flat Submersible cable 10 sqmm with bare bunched copper conductor for submersible pump motor with voltage grade 1100 volts as per IS 694/1990 including jointing, connecting with submersible motor to starter including removing old submersible cable complete all as specified and directed.
Cutting and threading 80mm (3" bore) both end MS / GI column pipe heave duty 3 Mtr long including new socket 80mm bore 100 mm long complete all as specified and directed.
S & F in repair, 15mm bore, float valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed (Minimum weight - 142 Gms).
M& L of repairing/ welding of pipe/ fitting of size 80 to 200mm including excavation in soft/dense soil & taking up pipe/fitting of size 80 to 200 mm dia GI/PVC cutting, rethreading/jointing the pipe and replacing unserviceable fitting returning and filling the excavated soil and testing the joint. Note:- Necessary Excavation upto 0.60 cum shall be included in the job complete all as specified and directed.
Supply / Fixing / Erecting in replacement of steel tubular poles complete with cast iron base plate, finial taper plug, bolts Nuts & screws complete all as specified type 410 SP-31 of 9 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint all as specified in IS and all as shown in drawing No CEJZ/TD/824/91, Sheet No1/2 dt 16.04.91 and writing pole no with yellow shade on black base using synthetic enamel paint having height of works exc 5 cm as directed by Engr-in-Charge :- Note:- PCC, Foundation wk and excavation, removal and returing filling will be paid and measured seperately.
M& L for providing cement concrete 1:4:8 Type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling for poles complete all as specified.
M& L for providing cement concrete PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate) as in pillars, plate forms, beds and coping around poles etc complete including necessary formwork and finishing the exposed surfaces even and smooth without using extra cement all as specified and
Material and labour in replacement control wiring / motor starter wiring of pump motor starter panel with PVC insulated copper contactor of sizes 2.5mm/4sqmm all as specified and directed.
S & F in replacement, air termination, single pointed Aluminium rod 12mm dia and 300 mm long with two Nos brass nut, bolt and washers to existing/new lightening conductor system complete all as specified and directed.
S & F in replacement, aluminium strip of size 32x6mm with and inclduling saddles and fixing etc and jointing of strips with suitable size of nut, bolt and washers for roof conductors and down conductors above ground complete all as specified and directed.
M & L for test point made by phosphorus bronze / gunmetal of size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm hex head screw complete with saddles and fixing screws for fitting the strips complete all as specified and directed.
M & L in replacement of gland packing of size 10/15/20 mm (Each roll 6 mtr length) complete all as specifed and directed
Supply and fixing of High intensity HIP reflective sign board made from hardened plastic aluminium combined sheet 2 mm thick (with high quality lamination), two sheets placed back to back aluminium pop riveted to stainless steel square pipe 40 x 40 mm of 16 gauge, frame of size 1300 x 840 mm. Frame supported with 25 mm and 50 mm round 2700mm long stainless steel pipe of 16 gauge welded to frame. Top end of legs closed with decorative stainless steel dome place. All stainless steel parts polished on plastic aluminium combined sheet, HIP blue reflective sheet shall be pasted on both side and with white fluorescent computer cut tape minimum 110mm height to be pasted on sign board and border of white HIP sheet shall be pasted and fixed in PCC (1:2:4) type B1 including dismantling existing old vintage damaged standing sign board, complete all as specified and directed by Engr-in-Charge.
Supply and laying well burnt sub class B bricks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
Per 1000 Nos
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.33 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.92 MB
Tend81149.pdf
Tender Documents • 2.29 MB
BOQ_829489.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .