| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST L1 | |
| 2 | L2₹28.3 L+₹4.3 L (17.7%)Rejected-Finance BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹28.9 L+₹4.9 L (20.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
21 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/O 56 APO PIN 913970
REPAIR AND MAINT OF DG SET AND SERVO STABILIZER AIR WATER HEATING PLANT AND SUMMER WINTER APLLIANCE AT MANASBAL UNDER GE 970 EWS
2022_MES_570821_1
GE 970 EWS-63/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 970 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹72,000
Yes
7 Mar 2023
23 Dec 2022
23 Jan 2023
23 Dec 2022
21 Jan 2023
7 Jan 2023
Amount
M&L for opening the unserviceable/burnt ceiling fan 1200/1400 mm sweep and cutting of old burnt copper winding and rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed (NOTE:- Taking down/dismantling of ceiling fan and refixing after repair shall deemed to be include in this unit rate.)
Supply and fixing in repair of ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed by engr-In-Charge. Make:- SKF/ NBC or Equivalent
Supply and fixing in repair of gun metal bushes of suitable size for ceiling fan incl necessary mechanical work, complete all as specified and directed.
Supply and fixing in repair of flexible cable, three core 0.5 Sqmm PVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. Make:- Plaza, Havells .
Supply and fixing in repair stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed.
Supply and fixing in repair capacitor of of 2.5 MFD for ceiling fan, complete all as specified and directed.
Supply and fixing in repair capacitor of 4 Mfd for exhaust fan, complete all as specified and directed.
Supply and fixing in repair of ceiling fan blade set of three, heavy duty suitable for 1200/1400mm sweep of as per existing make as direcetd.
Supply and fixing in repair of PVC canopy for ceiling fan 1200/1400mm sweep complete for existing various makes/model of fan, complete all as specified and directed by Engr-in-Charge.
M&L in repair for opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed as specified and directed. (NOTE:- Taking down/dismantling of exhaust fan and refixing after repair shall deemed to be include in this unit rate.)
All as per srl item No. 10 here-in-before, but 300mm sweep.
Supply and fixing in repair ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF/NBC or equivalent .
M&L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed.
M&L for servicing of geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed.
Supply and fixing in repair heating element for geyser of capacity 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells
Supply and fixing in repair Heating element for geyser of capacity 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells
Supply and fixing in repair thermostat for Geyser of capacity 25/35/50/100 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus
Supply and fixing in repair geyser syphon assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, as per existing complete all as specified and directed by engr-in-Charge.
All as per item Srl No. 18 above but for 35 Ltr capacity.
All as per item Srl No. 18 above but for 50 Ltr capacity.
Supply and fixing in repair rubber gasket for water heater storage type of any capacity and suitable as per the existing, complete all as specified and directed
Supply and Fixing in repair plug top 15/16 Amps for Geyser, complete all as specified and directed. Make:- Havells/ Anchor/Leader/Plaza
Supply and fixing in repair PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. Make:- Finolex/Polycab/L&T
S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified.
Supply and fixing in repair of safety valve for geyser of 25/35/50 litre capacity, as per existing make complete all as specified and directed
Supply and fixing in repair of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed.
Supply and fixing in repair heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/50 litre capacity, complete all as specified and directed.
Supply and fixing in repair copper inner tank of geyser capacity 15/25 litre and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed.
All as per item Srl No. 28 above but for 35 Ltr capacity.
All as per item Srl No. 28 above but for 50 Ltr capacity.
Supply & fixing in repair stop cock brass 15mm dia, complete all as specified and directed.
Supply and fixing in repair of GI anchor Bolt 100 mm long with nut & washers for geyser, complete all as specified and directed
Supply and fixing in repair of compressor of refrigerator of 165 to 200 ltr capacity as per the existing complete all as specified and directed.
Supply and fixing in repair of thermostat for refrigerator of 165 to 200 ltr capacity.
Supply and fixing in repair of thermal relay for refrigerator of 165 to 200 ltr capacity.
M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 165 to 335 ltr capacity all as specified and directed.
Supply and fixing in repair of compressor fo refrigerator of 210 to 335 ltr capacity as per the existing complete all as specified and directed.
Supply and fixing in repair of thermostat for refrigerator of 210 to 335 litre capacity.
Supply and fixing in repair of thermal relay for refrigerator of 210 to 335 litre capacity.
M&L charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 210 to 335 ltr capacity all as specified and directed.
Supply and fixing in repair of compressor fo deep freezer of 210 to 320 ltr capacity as per the existing complete all as specified and directed.
Supply and fixing in repair of thermostat for deep freezer of 210 to 335 litre capacity.
Supply and fixing in repair of thermal relay for deep freezer of 210 to 335 litre capacity.
M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for deep freezer of 210 to 400 ltr capacity all as specified and directed.
Taking out unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, replacement of knobs, LED's etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC complete all directed.
All as per item Srl No. 45 above but for capacity 1 to 2 KVA .
Repair of 1 KW/1.5/2KW heat piller including replacement of unserviceable parts i.e rod, blower motor, switches, wiring and other essential parts to make the heat piller fully functional complete all as specified and drected.
Supply only Kit, fuel filter (Primary, secondary & super bye pass) and ring complete for 180 Kva DG set.
Supply only Lubrication oil filter for 180 Kva DG set.
Supply only Air filter(Both inner/outer) suitable for 180 KVA DG set make Greaves Cotton testing and complete all as specified and directed.
All as per item No 1 above but DG set of 30 to 62.5 KVA capacity -ditto-
Supply only Kit, fuel filter (Primary, secondary & super bye pass) and ring complete for 180 Kva DG set.
Supply only Lubrication oil filter for 180 Kva DG set.
Supply only Air filter(Both inner/outer) suitable for 180 KVA DG set make Greaves Cotton testing and complete all as specified and directed.
S&F in replacement fan belt suitable for 30 to 180 KVA DG Set as per existing model and size complete all as specified and directed.
S&F in replacement V belt suitable for radiator of 30 to 180 KVA DG Set as per existing model and size mplete all as specified and directed.
Supply only replace of "O" Ring & washer set for 180 KVA DG Set complete all as specified and as directed.
Supply only set of hose for 180 KVA DG Set complete all as specified and as directed.
Supply only hose clip for 180 KVA DG Set complete all as specified and as directed.
Supply only thermostate for 180 KVA DG set complete all as specified and directed.
Supply only Piston assembly for 180 KVA DG complete all as specified and as directed
Supply only Piston Ring for 180 KVA Greaves complete all as specified and as directed
Supply only Engine liner for 180 KVA complete all as specified and as directed
M&L for repairing Engine liner for 180 KVA Greaves Engine by remetalling, regrinding, repolishing etc complete all as specified and as directed
Supply only CR bearing for 180 KVA DG suitable for Greaves Engine complete all as specified and as directed
Supply only main bearing for 180 KVA DG suitable for Greaves Engine complete all as specified and as directed
Supply only controller actuatar as per existing for 180 DG Set complete all as specified and as directed
Supply & filling Coolant concentrate Superkool xtra as required in the DG oil sump all as directed.
Supply & filling Engine Oil Premium Blue 15 W 40 grade API CI 4 PLUS / Kirloskar engine oil as required in the DG oil sump all as directed.
M & L for overhauling Turbo Charger assembly for 320 KVA DG Set including replacement of defective turbo kit and other defective parts, hydarulic pressure and testing including grinding , polishing & remettaling at work shop and cleaning of deposited material, applying of CRC and lubricants, and reassemble engine turbo assembly, testing etc complete all as specified and as directed.
M & L for overhauling Injector assembly for 180 KVA DG Set including replacement of defective injector sleeves, cups, fuel liner and other defective parts including replacing all o rings , hydarulic pressure and testing including grinding , polishing & remettaling at work shop and cleaning of deposited material, applying of CRC and lubricants, and reassemble engine injector assembly, testing etc complete all as specified and as directed.
M & L for overhauling Fuel pump assembly for 180 KVA DG Set including replacement of defective fuel pump kit, gear. bearing, washers, O rings, and other defective parts including hydarulic pressure and testing and cleaning of deposited material, applying of CRC and lubricants, and reassemble engine injector assembly, testing etc complete all as specified and as directed.
M & L for repairing(servicing) of radiator core assembly including dismantling, overhauling, cleaning and repairs, weldings to radiator assembly and replacement of other defective hose / inlet & outlets etc of DG set of 180 KVA Capacity and any make including any necessary welding of leaked/broken parts at site, changing of screws and nuts, bolts etc complete all as specified and as directed. Note: Quoted rate shall be inclusive of transportation cost upto workshop and return to site complete all as specified and as directed.
Calibration of PT pumps, replacemnt of PT pump kit, gasket set,washers,nuts,plungers,delivery valves,oil pump,o ring and set the oil pressure with testing suitable for 180 KVA SG set complete all as specified and as directed. Make- Greaves/Kirloskar/Ashok Leyland
Supply and fixing water pump assembly suitable for 180 KVA DG Set complete all as specified and as directed.
M & L for overhauling Turbo Charger assembly for 63 KVA DG Set including replacement of defective turbo kit and other defective parts, hydarulic pressure and testing including grinding , polishing & remettaling at work shop and cleaning of deposited material, applying of CRC and lubricants, and reassemble engine turbo assembly, testing etc complete all as specified and as directed.
M & L for overhauling Injector assembly for 30/35 KVA DG Set including replacement of defective injector sleeves, cups, fuel liner and other defective parts including replacing all o rings , hydarulic pressure and testing including grinding , polishing & remettaling at work shop and cleaning of deposited material, applying of CRC and lubricants, and reassemble engine injector assembly, testing etc complete all as specified and as directed.
M & L for overhauling Fuel pump assembly for 30/35 KVA DG Set including replacement of defective fuel pump kit, gear. bearing, washers, O rings, and other defective parts including hydarulic pressure and testing and cleaning of deposited material, applying of CRC and lubricants, and reassemble engine injector assembly, testing etc complete all as specified and as directed.
Supply only Piston assembly for 30/35 KVA Kirloskar complete all as specified and as directed Make Engine
Supply only Piston Ring for 30/35 KVA Kirloskar complete all as specified and as directed Make Engine
Supply only Engine liner for 30/35 KVA Kirloskar Engine complete all as specified and as directed
Supply only for repairing Engine liner for 30/35 KVA Kirloskar Engine by remetalling, regrinding, repolishing etc complete all as specified and as directed
Supply only set of hose clip for 30/35 KVA DG Set complete all as specified and as directed.
Supply only set of hose for30/35 KVA DG Set complete all as specified and as directed.
Supply only set of "O" Ring & Washer for 30/35 KVA DG Set complete all as specified and as directed.
M & L for replacing 04 Nos defective engine anti vibration pads by removing engine from foundation by using crane / hydra and reinstall after replacing defective pads for 63 KVA DG set complete all as specified and as directed
M & L for replacing 04 Nos defective engine anti vibration pads by removing engine from foundation by using crane / hydra and reinstall after replacing defective pads for 30/35 KVA DG Set complete all as specified and as directed.
Supply and fix in repair of AMF Controller for AMF Panel for 180 KVA DG Set Panel board as directed by Engr-in-charge including necessary cable leads, lugs etc complete all as specified and as directed
Supply and fix in replacement of Contactor for manins/DG outpur suitable for 180 KVA DG Set Panel board as directed by Engr-in-charge including necessary cable leads, lugs etc complete all as specified and as directed. Make : L&T/C&S/Siemens/ABB/Lengrand
Supply and fixing in repair control panel wiring for AMF Panel for 35/63 KVA DG Set as per existing all as directed by Engr-in-charge including necessary cable leads, lugs etc complete all as specified and as directed.
Material and labour for repairing to 12/24V self starter assembly by replacing worn out parts such as carbon coils, pinion, sletch megnetic,bearing, screws, nuts and bolts, washers, gasket, O rings, copper washer and other minor material and applying CRC and reassemble the same and re fix in DG set, testing etc complete including taking to workshop and return back after necessary repair works. Note: Quoted rate shall be inclusive of transportation cost upto workshop and return to site complete all as specified and as directed
Material and labour for repair including replacement of any spare of Field coil assembly of 24/12V Self starter Lucas Make installed of 180/63/35 KVA DG set as per existing including taking down damaged assembly, transport to workshop and return and refixing it after repair complete all as specified and as directed
Material and labour for repair including replacement of any spare of Armature coil assembly of 24/12V Self starter Lucas Make of 30/35/65/180 KVA DG set as per existing including taking down damaged assembly, transport to workshop and return and refixing it after repair complete all as specified and as directed
Supply and fix in replacement battery lead with approx 1mtr length terminals for 12 V 150 AH to 200 AH battery complete all as specified and as directed
Supply and fix in replacement battery 12V 150 AH for DG setcomplete all as specified and as directed. Make : Exide / Amco / Amaron / V Guard
Supply and fix in replacement of diesel fuel pipe ISI marked along with connectors of suitable length as per site complete all as specified and as directed
S & F Control and time delay electrical Relay of suitable capacity as per existing sample in AMF panels complete all as specified and as directed. Make: C&S/ Schnieder/ ABB/ L&T
S & F relay base for electrical Relays of suitable capacity as per existing sample in AMF panels all complete all as specified and as directed
S & fix in replacement CT of any capacity for DG Panels as per existing sample in AMF / Syncroniziation / DG panelscomplete all as specified and as directed
S & fix in repair LED indicating lamp for DG Panels as per existing sample in AMF / Syncroniziation / DG panels complete all as specified and as directed
Supply & fix in repair of 250A 4 Pole MCCB in 180 KVA AMF Panel Board complete all as specified and as directed ( Make :L&T /Siemens/ABB/Legrand)
Supply & fix in repair of 100A 4 Pole MCCB in 35/63 KVA DG Panel Board complete all as specified and as directed ( Make-L&T /Siemens/ABB/Legrand )
Supply & fix in repair of 32A 4 Pole MCCB in 35 KVA DG Panel Board complete all as specified and as directed ( Make-L&T /Siemens/ABB/Legrand )
Supply & fix in repair of Aotomatic voltage regulator for DG set capacity 30 to 180 KVA DG set complete all as specified and directed.
Dismantling old unsv conventional earth pit including electrode plate/pipe from position and material and labour for maintenace free modern marconite® conductive concrete based technology earthing system in same or different place where directed with copper earth electrode of suitable size including back fill compound and other accessories as required and recommended by OEM and connecting with copper strip of size 25x3 mm in position (connecting upto 7.5 mtr length max)complete all as specified and as directed and having following specifications :- a) Fixed Carbon 98.5 % b) Ash, Volatile and Water 1.5 % c) Sulphur Content 1.5 % Maximum d) Size Grading (Approx) - 10% below 0.10 mm, 5% above 3.15 mm, 85% between 0.10 mm and 3.15 mm (e) Thermal Stability Between (-) 10% and (+) 60% ambient temperature (f) Ultra Low Resistivity (g) Versatile - shall be suitable for all type of soil and climate (h) Consistent Performance (i) Chemically Inert (j) Non-corrosive (k) Maintenance free and life span.
Supply and installation of on load change over switch in sheet metal enclosure of capacity 4P 100 Amps, complete all as specified and as directed Make : Indoasian or equivallent in CG/ Havells
Supply and installation of on load change over switch in sheet metal enclosure of capacity 4P 200 Amps, complete all as specified and directed. Make :Indoasian or equivallent in CG/ Havells
Taking down carefully the existing defective 100/160/200 KVA servo voltage stablizer for inspection at site or factory, if required by disconnecting LT connection/underground cables and earth strips etc. from substation / locations using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the stablizer after repairs and testing, transportation to site and unloading including placing at given position and re-commissioning complete all as specified and as directed. Note :1. All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted. 2. Cost of rewinding, if required shall be measured and paid separately under relevant item
M&L for super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding the transformer of any capacity / any make complete all as specified and as directed.
Supply and filling of fresh transformer power oil of BDV not less than 60 KV for topping up of reduced level of stablizer due to evaporation/ leakage/losses due to dehydration in 100 to 200 KVA or for replacement complete including removing of old unservicable transformer oil all complete all as specified and as directed. Make should be power oil/castrol/pure lubes.
M & L for conducting oil filtration by stream line / Vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for distribution transformer & as BDV of oil 40 to 50 KV for 1 min incl routine testing after filtration for any capacity of transformers complete all as specified and as directed. (Note : The contractor shall change the filter assy before starting the filtration of power/ distribution transformer of any capacity in presence of Engr In charge)
Taking down or out existing cable of sizes 2/3.5/4 core 25 sqmm to 95 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal complete all as specified and as directed. Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule
Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16sqmm 4 core including necessary cable lugs, glands, insulation complete all as specified and as directed. MAKES : HAVELLS/FINOLEX / GLOSTER/ POLYCAB
Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 25 sqmm 4 core including necessary cable lugs, glands, insulation tape complete all as specified and as directed. MAKES :HAVELLS/FINOLEX / GLOSTER/ POLYCAB
Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 35 sqmm 3.5 core including necessary cable lugs, glands, insulation tape complete all as specified and as directed. MAKES : HAVELLS/FINOLEX / GLOSTER/ POLYCAB
Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape complete all as specified and as directed. MAKES : HAVELLS/FINOLEX / GLOSTER/ POLYCAB
Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 70 sqmm 3.5 core including necessary cable lugs, glands, insulation tape complete all as specified and as directed. MAKES : HAVELLS/FINOLEX / GLOSTER/ POLYCAB
Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 95 sqmm 3.5 core including necessary cable lugs, glands, insulation tape complete all as specified and as directed. MAKES : HAVELLS/FINOLEX / GLOSTER/ POLYCAB
Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr in wide and not exc. 1.5m in depth for taking out / laying of under ground cable in trenches or cable ducts complete all as specified and as directed. Note for excavation : Excavation and related eartrh work shall be carried out through labour manually and no mechanical means shall be permitted.
Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables complete all as specified and as directed
Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified and as directed
M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR Part -I complete all as specified and as directed. Note : punned thickness shall be measured for payment purpose
Supplying and laying unreinforced precast concrete cable cover, class LV, type 1 flat, size 300mmx 150mm x 40mm complete all as specified and as directed
Top Mind Industries Pvt Limited
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .