Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC D 154 ADARSH NAGAR JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹44.5 L+₹1.6 L (3.79%)Rejected-Finance 14 L N Y MARKET RANJHI JABALPUR MP 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹46.3 L+₹3.4 L (8.01%)Rejected-Finance 1890 NEW SHOBHAPUR COLONY VEHICLE FACTORY ROAD JABALPUR MP 482009 | JABALPUR | MADHYA PRADESH | 482009 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹46.6 L+₹3.8 L (8.76%)Rejected-Finance H NO 114 A 10 GHAZI NAGAR RADDI CHOWKI GOHALPUR JABALPUR MP | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹46.7 L+₹3.8 L (8.94%)Rejected-Finance PLOT NO 12 SAKAR GRAH NIRMAN SOCIETY TILHARI MANDLA ROAD JABALPUR MP 482001 | JABALPUR | JABALPUR | MP | 482001 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
1 Dec 2021, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
CERTAIN REPAIRS TO PLASTERING, FLOORING, CEILING AND MISC B/R WORKS AT 2TTR AND JCOS / ORS MARRIED ACCN UNDER GE (WEST) JABALPUR
2021_MES_486254_1
8388/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹96,000
11 Jan 2022
3 Nov 2021
3 Dec 2021
3 Nov 2021
1 Dec 2021
17 Nov 2021
4 Nov 2021 - 15 Nov 2021
Amount
Taking down cement plaster on brick/ stone masonary including raking out joints, hacking for scrubbing down with water etc. complete all as specified and as directed (Rates are in cluded for upto G+2 floors, and no extra payment to be made for scaffolding and any other arrangement ).
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilliate demolition complete all as specified and directed.
M&L for brick work with sub class ‘B’ brick, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls with old size bricks built in cement mortar 1:4 complete all as specified and as directed.
M & L for RCC (1:2:4) nominal Mix using 20mm graded aggregate in chajjas,parapet facia etc complete all as specified and as directed.
M & L for RCC (1:2:4) nominal Mix using 20mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m spancomplete all as specified and as directed.
M & L for RCC (1:2:4) nominal Mix using 20mm graded aggregate in slab supported on walls,beam and column in floors, roof, landing, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Fair finish form work to sides and soffits of floor or roof beams, beam hunching, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also splays between floors and beams etc. complete all as specified and directed.
Formwork to chajjas, troughs and similar items including edges fair finished complete all as specified and directed.
Fair finish form work to Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
S&F Mild steel TMT bars 6mm to 8mm dia and cut to length bent to shape required, including cranking, bending and binding as in stirrups, spacers and binders etc. with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete all as specified and directed.
M&L for 5mm thick cement plaster in cement mortar 1:3 as on ceiling, soffits of RCC shelves, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4) with WPC on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed (WPC shall be measured seperately) (Rates are in cluded for upto G+2 floors, and no extra payment to be made for scaffolding and any other arrangement ).
M&L for 15mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer complete all as specified.
Prepration of newly plastered surfaces and applying three coat of white wash on ceiling all as specified.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over one coat of cement primer etc complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of weather proof paint over priming coat complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured joint free tiles 7 to 8 mm thick area of each tile exceedeing 0.18 sqm but n.exc 0.38 sqm (600x600), in floors, set and jointed in neat cement slurry and pointed in white cement fixed over and including 15 mm thick screed bed in CM (1:6) complete etc all as specified and directed.
M&L for non skid ceramic coloured joint free tiles 7 to 8 mm thick area of each tile exceedeing 0.18 sqm but n.exc 0.38 sqm (600x600), as in vertical surfaces such as skirting / dado set and jointed in neat cement slurry and pointed in white cement fixed over and including 10 mm thick backing in CM (1:4) complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceedeing 0.11 sqm but n.exc 0.18 sqm, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceedeing 0.06 sqm but n.exc 0.11 sqm, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
Material and labour for Glazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 10mm thick rendering in CM 1:4 etc complete all as specified and directed.
M&L for Vitrified ceramic tiles 10mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqm fixed over and including 15mm thick screed bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile etc complete all as specified.
M&L machine cut kota stone slab flooring 20-25mm thick over and including cement Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M&L machine cut kota stone slab flooring 20-25mm thick as in riser of steps, skirting, dado and pillar laid over and including 10mm thick cement screed in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
Demolition of cement concrete in ground floor & paving n. exc 15 cm thick (below or above GL) unreinforced complete all as specified and all as directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in floor finishes 100 mm thick laid in panels & finished even and smooth without using extra cement complete all as specified and directed. Note- Glass dividing strips shall be measured & paid separately as supply only.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate, 75mm thick as in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed (Note :-reinforcement where provided shall be measured and paid seprately) complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid dry or laid dry and pointed complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded stone agg as in sub base finishing the surface even and rough to receive floor finishes complete all as specified and directed.
M&L for 60 mm M35 grade thick Machine pressed rubber moulded precast concrete interlocking paver block any shape and size with grey cement and pigment, confirming to IS 15658-2006 fixed over and including 50mm thick sand coushioning etc complete all as specified and as directed.
M&L for coloured rubber moulded cement concrete chequered tiles 300x300x22 mm thick with cement and coloured pigment, set and jointed in neat cement slurry and pointed in coloured cement to match as in floors fixed over and including 15mm thick screed bed to floor finishes in cm 1:6 complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F in repairs for Sheet glass ordinary quality 3 mm thick in square n exc 0.50 Sqm each pane glazing with oil putty, clip in metal frame or wooden beading in wooden frame complete all as specified (Rates in cluded for G+2 floors, and no extra payment to be made for the same).
Supply and fixing in repairs 3 mm thick, figured glass ,pin headed type and glazing with oil putty in square n exc 0.5 sq.m each pane etc complete all as specified and as directed.
Dismantling of timber scantlings unframed 40Sq Cm and over in section, in any position complete all as specified and directed.
M&L for Second class hard-wood in scantlings and clean sawn timber framed and fixed complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. conforming Fe-410W(GdeE-250) quality B complete all as specified and directed.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, wind ties etc. conforming Fe 410 -W (GdeE- 250) qualityA complete all as specified and directed.
S&F Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete tairs conforming Fe-410W(GdeE-250) quality B complete all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming Fe-410W(GdeE-250) quality B complete all as specified and directed.
S&F 1.25mm thick mild steel, plain, black sheet in hearths; covering to door shut ters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semi corrugated,etc) sheets in roof covering complete all as specified and directed.
M&L for 6mm thick non asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
Refixing only 6mm thick non asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering incl ridge complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strenth of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenth of 550 Mpa as in roof covering/cladding and ridge line cover ,fixed with self tapping screws all as specified and as directed.
Dismantling of wall and ceiling boards( fibre pulp insulation etc) any thickness including cover fillets all as specified and directed.
M&L for suspended false ceiling system using chicago metallic (E grid) exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length) with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as specified and directed of Make :- ARMSTRONG AND EVEREST or other equivalent as approved.
S&F in repairs 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack clamp complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches including stack clamp complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack clamp complete all as specified and directed.
S&F in reparis 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches including stack clamp complete all as specified and directed.
S&F in reparis 75mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
Rai Construction Co
M/S A K MUKHERJEE
HAFEEZ CONSTRUCTION
upadhyay Builders
Hemant Associate
MAYANK CONSTRUCTIONS
KRD ASSOCIATE
M/s Kehar Engineers
Baggay construction Company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .