Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹47.8 L+₹6.0 L (14.5%)Rejected-Finance H NO 411 SECTOR 4 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU | J K | 180015 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹48.8 L+₹7.1 L (16.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Mehar Enterprises L2 | M/s Koul & Sons L1 | SHANTI ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Note: Taking down carefully old FTL fitting recessed mounted light fittings/ceiling complete with all accessories and making necessary electric connection, complete all as spd & directed by Engr-in charge. | 522 | Sqm | 48 ₹25,056 | 22 ₹11,484 Lowest | 48 ₹25,056 |
| 2.00 | M&L for 9mm Pre-laminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws/nails to timber frame work in wall portion complete all as specified and directed. | 232 | Sqm | 1,020 ₹2,36,640 | 885 ₹2,05,320 Lowest | 1,500 ₹3,48,000 |
| 3.00 | Providing & fixing false ceiling with semi perforated 12mm thick micro tegular edged GRG at all heights with GRG false ceiling tiles of size 595X 595 mm of approved texture design and patterns having moisture content less than 2% humidity resistance of 99% NRCO.50 to 0.75 as per IS 8225:1987,Noncombustible as per BS476(part4)-1970 and light reflectance of 85%(min) to be laid in true horizontal level suspended on inter locking metal T-grid of hot dipped galvanised iron sec of 0.33 mm thick (galvanised @ 120 grams per sqm incl both sides) comprising of main -T runners of size 15x 32 mm of length 3000mm ,cross-T of size 15X32 mm of length 600 mm to form grid module of size 600 x600 mm suspended from ceiling using galvanized mild steel items (galvanizing @80mm per sqm ) i'e 50mm long 8 mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85 x 25 x 2 mm ,Galvanised iron perimeter wall angle of size 24 x 24x 0.40 mm of length 3000 mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws.The work shall be carried out as per specifications, drawing and as per directions of the Engr-in-Charge. | 220 | Sqm | 1,440 ₹3,16,800 | 1,390 ₹3,05,800 Lowest | 1,650 ₹3,63,000 |
| 4.00 | Dismantling of timber scantling in fillets, posts, rafters, purlins etc under 40Sq. Cm in section in framed work complete all as specified and directed. | 482 | RM | 16 ₹7,712 Lowest | 29 ₹13,978 | 29 ₹13,978 |
| 5.00 | M&L for 2nd class hard wood timber scantling plain fillets square, rectangular in section area exc 13 Sqcm and not exc 25sqcm secured with nails complete all as specified and directed. | 482 | RM | 178 ₹85,796 | 99 ₹47,718 Lowest | 270 ₹1,30,140 |
| 6.00 | M&L for 2nd class soft wood fillets sectional area exc 3 sqcm and n exc 6 sqcm rectangular or triangular in section but bullnosed, splayed, chamfered or rounded on one edge of face, secured with nails or brads, complete all as specified and as directed. | 232 | RM | 110 ₹25,520 | 89 ₹20,648 Lowest | 120 ₹27,840 |
| 7.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. | 275 | Sqm | 53 ₹14,575 | 25 ₹6,875 Lowest | 80 ₹22,000 |
| 8.00 | M&L for coloured Non Skid Ceramic joint free tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed. | 239.5 | Sqm | 1,390 ₹3,32,905 | 1,300 ₹3,11,350 Lowest | 1,590 ₹3,80,805 |
| 9.00 | Demolition of cement concrete (un-reinforced) in ground floors & paving n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. | 6.15 | Cum | 890 ₹5,473.5 | 850 ₹5,227.5 Lowest | 850 ₹5,227.5 Lowest |
| 10.00 | M&L for cement concrete 75mm thick type D - 2 using 40mm graded stone aggregate as in sub base to receive floor finish etc complete all as specified and as directed. | 20 | Sqm | 390 ₹7,800 | 370 ₹7,400 Lowest | 370 ₹7,400 Lowest |
Tender Value
₹44.0 L
EMD Value
₹87,960
Closing Date
26 Jun 2025, 6:00 pmClosed
GE 860 EWS, Karu
GE 860 EWS, Karu
PROVN OF BATHROOM CUM TOILETS AT SHESHARTHANG AND PROVN OF 02 JCOs ORs TOILET AT TANGTSE AND SPECIAL REPAIR TO BLDG NO T88 T89 AT TANGTSE AND BLDG NO. T740 AT KARU AREA UNDER GE 860 EWS
2025_MES_710530_1
8173/2025-26/E8
Open Tender
Civil Works
Item Rate
270 days
Karu and Shesharthang
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE 860 EWS, Karu
₹87,960
Yes
7 Aug 2025
29 May 2025
30 Jun 2025
29 May 2025
26 Jun 2025
12 Jun 2025
Amount
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. Note: Taking down carefully old FTL fitting recessed mounted light fittings/ceiling complete with all accessories and making necessary electric connection, complete all as spd & directed by Engr-in charge.
M&L for 9mm Pre-laminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws/nails to timber frame work in wall portion complete all as specified and directed.
Providing & fixing false ceiling with semi perforated 12mm thick micro tegular edged GRG at all heights with GRG false ceiling tiles of size 595X 595 mm of approved texture design and patterns having moisture content less than 2% humidity resistance of 99% NRCO.50 to 0.75 as per IS 8225:1987,Noncombustible as per BS476(part4)-1970 and light reflectance of 85%(min) to be laid in true horizontal level suspended on inter locking metal T-grid of hot dipped galvanised iron sec of 0.33 mm thick (galvanised @ 120 grams per sqm incl both sides) comprising of main -T runners of size 15x 32 mm of length 3000mm ,cross-T of size 15X32 mm of length 600 mm to form grid module of size 600 x600 mm suspended from ceiling using galvanized mild steel items (galvanizing @80mm per sqm ) i'e 50mm long 8 mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85 x 25 x 2 mm ,Galvanised iron perimeter wall angle of size 24 x 24x 0.40 mm of length 3000 mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws.The work shall be carried out as per specifications, drawing and as per directions of the Engr-in-Charge.
Dismantling of timber scantling in fillets, posts, rafters, purlins etc under 40Sq. Cm in section in framed work complete all as specified and directed.
M&L for 2nd class hard wood timber scantling plain fillets square, rectangular in section area exc 13 Sqcm and not exc 25sqcm secured with nails complete all as specified and directed.
M&L for 2nd class soft wood fillets sectional area exc 3 sqcm and n exc 6 sqcm rectangular or triangular in section but bullnosed, splayed, chamfered or rounded on one edge of face, secured with nails or brads, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for coloured Non Skid Ceramic joint free tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors & paving n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for cement concrete 75mm thick type D - 2 using 40mm graded stone aggregate as in sub base to receive floor finish etc complete all as specified and as directed.
M&L Screed bed or bedding layer 20 mm thick in cement mortar 1:4 on floors for laying floor finish complete all as specified and as directed.
S&F coloured chequered cement concrete tiles 30 cm x 30cm x 25 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and as directed.
M&L for providing cement concrete 1:2:4, type B-1 using 20 mm graded crushed stone aggregate for fixing edges of chequered tiles and rounded or chamfered edges, coping complete all as specified and directed.
Taking down of chowkats with shutter (without taking of shutter from frame) exc 1.5 Sqm but not exc 4 sqm each complete all as specified and directed.
S&F 2nd class hard wood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F plain 2nd class hardwood 35mm thich framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
Taking down of chowkats with shutter (without taking of shutter from frame) n exc 1.5 Sqm each complete all as specified and directed.
S&F 30mm thick 2nd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) completed all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty and glazing pins in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 100mm size, butt hinges, cold rolled steel or stainless steel with screw, medium weight , ISI marked complete all as specified and directed.
S&F 125mm long Aluminium, anodised, barrel tower bolt, Mild steel or stainless steel having dia/shoot not less than 10 mm with screws complete all as specified and directed.
S&F 125mm size, extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
S&F 250mm long, Mild steel or stainless steel, sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S&F 75mm size, butt hinges, cold rolled steel or stainless steel with screw, medium weight , ISI marked complete all as specified and directed.
S&F 100mm long Aluminium, anodised, barrel tower bolt, Mild steel or stainless steel having dia/shoot not less than 10 mm with screws complete all as specified and directed.
S&F 100 mm size, extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
M&L for 0.63mm thick CGI sheets fixed to wall/roof with two corrogations side lap, fixed with L- type or J type or cranked hook bolts and washers with grade of zinc coating 275 complete all as specified and directed.
M&L for 0.63mm thick CGI sheets fixed to wall/roof with two corrogations side lap, fixed with L- type or J type or cranked hook bolts and washers but except sheeting complete all as specified and directed.
M&L 0.63 mm thick plain galvanised mild steel sheeting, in ridges, hips, valley gutter, drip and straight flashings fixed with L- type or J type or cranked hook bolts and washers with grade of zinc coating 275 complete all as specified and directed.
M&L for two coat of synthetic enamel paint over a coat of red oxide on new steel surfaces of any description, not otherwise described over 10cm width or girth incl preparing new zinc or galvanised surfaces to receive painting by coating with mordant solution incl washing and cleaning etc completed all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) 75 mm thick as in plinth protection/PCC Path complete all as specified and directed.
M&L for preparing old painted steel and iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint all as specified & directed by the Engr-in-Charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m depth for foundation and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete (PCC) type D2 1:4:8 (40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for reinforced cement concrete (RCC) Type B1 1:2:4 using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for reinforced cement concrete Type B1 1:2:4 using 20mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge.
M&L for reinforced cement concrete (RCC) nominal Mix Type B1 1:2:4 using 20mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge.
M&L Steel sheet form work to sides of concrete foundations,footings, bases of columns raft and beams sides and soffits(if any) of foundations and plinth beams and similar work,vertical or to batter,for rough finished flat surfaces of concretecomplete all as specified and directed by Engr-in-Charge.
M&L for Steel sheet Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engr-in-Charge.
M&L for Steel sheet formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of concrete complete all as specified and directed by Engr-in-Charge.
M&L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(annealed ) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M&L mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, cut to length, bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(annealed ) not less than 0.9mm dia or securing with clip complete all as specified and directed by Engr-in-Charge.
M&L Precast cement concrete block masonry type C1 1:3:6 (using 20mm graded crushed stone aggregate) with solid blocks, exc. 10cm in width and, setting in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface in broken stone or boulders complete all as specified and directed.
M&L for Cement Concrete type -D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) -100mm thick as in Sub base complete all as specified and directed by Engr-in-Charge.
M&L machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cemnt slurry mixed with pigment to match the shade of the slab including 20 mm thick screed bed cm 1:6, rubbing and polishing complete all as specified and directed by Engr in Charge.
M&L for Glazed ceramic tiles 450X 300X 7mm thick mm thick coloured/shaded as in vertical surfaces such as skirting dados etc set and jointed in neat cement slurry over 15 mm th backing coat in CM 1:4 and pointed in coloured cement to match the surface complete all as specified and directed by Engr-in-Charge.
M&L for Rendering 15mm thick in CM (1:4) using finished even and smooth surface without using extra cement complete all as specified and directed by Engr-in-Charge. Note: (WPC shall be measured and paid separately)
M&L for preparation of new plastered surfaces and apply two coats of cement base paint over a coat of primer complete all as specified and directed by Engr-in-Charge.
M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed.
S&F Vitreous china ( EWC)pedestal pan and trap , including connection to drain ( or outgoing pipe ) and to flushing pipe antisyphonage pipe, with seat cover etc complete including concrete and making good to floor. complete all as specified and directed by Engr-in-Charge.
S&F vitreous china water closet (Squatt Pan) Orrisa pattern 580x440 mm size pan white with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to 'flushing cistern/pipe' complete all as specified and directed including 100mm CI/PVC 'P' trap.complete all as specified and directed by Engr-in-Charge.
S&F PVC low level white flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle etc with flush pipe of polyethylene of low density 32 mm dia of suitable length and making all connection complete all as specified and directed by Engr-in-Charge.
S&F tubular towel rail 20 mm dia,D type, 60 mm long between flanges complete all as specified and directed by Engr-in-Charge.
S&F Viterous China WHB table top Rectangular/Oval shape of size 650x450x150 mm with CP Waste coupling 32mm and PVC waste pipe 750mm long complete all as specified and directed by Engr-in-Charge.
S&F 1000 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engr-in-Charge.
S&F 20 mm bore PPR , globe or gate valves, (brass insert) fixed complete all as specified and directed by Engr-in-Charge.
S&F floor trap of PVC 100 mm out let dia with grating and jointed to waste pipe complete all as specified and directed by Engr-in-Charge.
M&L for PVC (SWR) 110 mm gully trap setting joining with solvent cement complete all as specified and directed.
S&F 3 layer PP-R Polypropyene ransom copolymer outer dia of pipe 20 mm concealed pipes SDR 7.4 (PN-16) UV stabilzed and anti microbial fusionwelded having thermal stavility for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed by Engr-in-Charge.
S&F 3 layer PP-R Polypropyene ransom copolymer outer dia of pipe 25 mm concealed pipes SDR 7.4 (PN-16) UV stabilzed and anti microbial fusionwelded having thermal stavility for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed by Engr-in-Charge.
S&F 15 mm bore Angle cock, cast copper alloy, screwed down, high pressure, with capston head handle, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S&F PVC connection 15mm size with PTMT nuts of length 450 fixed complete all as specified and directed.
S&F bib taps,15mm bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-Charge.
Supply and fix 15mm bore pillar taps CP brass chromium plated fancy type screwed down high pressure with chromium plated screwed shanks and fly nuts complete screwed for iron pipe in repairs all as specified and directed.
Plain cement concrete 1:3:6 Type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and hunching against the sides of pipes after they are laid and tested for 150 mm bore SGSW pipe complete all as specified and directed by Engr-in-Charge.
S&F 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed by Engr-in-Charge.
S&F 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed by Engr-in-Charge.
S&F 150mm dia, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engr-in-Charge.
S&F Viterous China wash urinal, half stall type, white complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with and incl 60mm long brass screws, pointing around urinal back in cement incl 32mm dia PTMT waste coupling, 32mm dia PVC waste pipe and urinal spreader complete all as specified and directed by Engr-in-Charge.
S&F aluminium anodised powder coated windows / ventilator with side hung shutters / sliding shutters and frame made with aluminium section with and including glass/particle board 12mm thick (as specified below) Aluminium sections shall be of size as given below:- Frame : 44.5x44.5x1.60mm thickTop/bottom rail; 90x44.5mmx1.60mm thickside style/rails of shutter-44.5x44.5mmx1.60mm thick Glass : 5mm thick plain glass with rubber gasket with aluminium beading . Aluminium fitting such as peg stay, aluminium hinges, aluminium handle 100mm long, aluminium tower bolt 100mm long and making good of wall surface with matching to existing surface, complete all as specified and as directed by Engr-in-Charge.
M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed by Engr-in-Charge.
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed by Engr-in-Charge.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
M&L for Fe 410-W (Gde-E-250 qanlity-A) roof trusses(framed) ,trussed,purlins,crane gantries ,rail and fastening and heavy bracket framing (Beam,tee ,angle,channel or flat sections) including distance pieces, cleats etc directed by Engr-in-Charge.
S&F 150mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr-in-Charge.
S&F 150mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge.
Excavating over areas, n.exc 1.5 m deep and getting out in hard/dense soil complete all as specified and as directed by Engr -in-charge.
Excavating over areas, n.exc 1.5 m deep and getting out in hard/dense soil for each additional 1.5 m or part thereof in depth beyond the first 1.5 m complete all as specified and as directed by Engr -in-charge.
M&L for walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and as directed by Engr -in-charge.
M&L for walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted, laid dry complete all as specified and as directed by Engr -in-charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; for rough finish and flat surfaces not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed by Engr -in-charge.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, rough finished surfaces of concrete complete all as specified and as directed by Engr -in-charge.
M&L for reinforced cement concrete Type B1 1:2:4 using 20mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and as directed.
S&F cone cap cowl 80 mm dia, over vent pipe complete all as specified and as directed by Engr -in-charge.
S&F grid false ceiling GI system powder coated prelude (main runner section 32x24x0.30x3600mm, cross tee 25x24x0.30x1200mm, wall angle 24x24x0.40x3000mm and including providing and fixing PVC pre-laminated in frontside and aluminium foil backed gypsum tile board of size 595 x 595 x 8-9mm fixed in ceiling frame work with necessary fastening GI wire and cleats complete all as specified and directed by Engr-in-Charge.
S&F in repair for SDC Laminated flooring 8mm thick of any coloured, manufactured by Direct Pressure Laminated (DPL) wherein the empty Abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength laid over 1mm thick foam base, complete including removal of existing flooring, all as directed by the Engr-in-Charge.
M&L for preparation of old painted surfaces of wood or wood based material and applying one coat of synthetic enamel paint on surface of any description over 10cm width or girth complete all as specified and directed by Engr-in-Charge.
S&F in repair 100mm size, butt hinges, cold rolled steel with screw, medium weight , ISI marked complete all as specified and directed by Engr-in-Charge.
S&F 200mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engr-in-Charge.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty and glazing pins in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge.
M&L for Coloured Non Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 all as specified and directed by Engr-in-Charge.
S&F in repair Vitreous China wash basin, white, pedestal type flat back, size 580x450irun include waste pipe, chain and plug and porcelain stopper but including brackets complete all as specified and directed by Engr-in-Charge.
S&F in repairs 15 mm bore stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs 32 mm dia bore waste fittings brass chromium plated fixed to wash hand basin, sinks with long screwed shanks and fly nuts flange and bedded in red lead cement and other end fixed complete all as specified and directed.
S&F in repair 3 layer PP-R Polypropyene ransom copolymer outer dia of pipe 16 mm concealed pipes SDR 7.4 (PN-16) UV stabilzed and anti microbial fusionwelded having thermal stavility for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed by Engr-in-Charge.
S&F floor trap of PVC 75 mm out let dia with grating and jointed to waste pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engr-in-Charge.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge.
M&L preparation of steel Surfaces new untreated surface apply one coat of red oxide,zink chrome and two coat of synthetic enamel (ordinary tint) paint any description, over 10cm in width or girth,not otherwise described complete all as specified and directed by Engr-in-Charge.
Demolition of Cement Concrete (Unreinforced) in ground floors and pavings n exc. 15cm thickness (below or above ground level), complete all as specified and directed by Engr-in-Charge.
S&F in repair aluminium anodised glazed door complete with shutter size of style top rail and lock rail 83x45x1.60mm thick and bottom rail 114x44x1.60mm thick and door frame size 63x38x1.60 mm including aluminium mongry fitting, hinges, tower bolt, handle, lock etc all necessary fittings and glazing with 5mm thick tinted glass/12mm thick pre laminated particle board complete including rubber lining at sides for air locking with complete all as speicified and as directed by Engr in Charge.
M&L for 15 mm Screed bed or bedding layer of cement mortar 1:6 laying floor finishes complete all as specified and directed by Engr-in-Charge.
Material & labour 15mm thick rendering in CM 1:6 on fair faces of brick wall or concrete surfaces finished even and fair complete all as specified and directed by Engr-in-Charge.
Rendering 5mm thick in CM (1:3) finished even and smooth without using extra cement on ceilings complete all as specified and directed by Engr-in-Charge.
M&L three coats of white wash on ceilings on newly plastered prepared surface complete all as specified and directed.
M&L for three coats of white wash on newly plastered prepared surface complete all as specified and directed.
Supply only water proofing compound for external plaster complete all as specified and directed.
S&F rotantional moulded polythylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top ) hoisted and fixed in posplinition complete with ball valve of high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball and screwd for iron pipe 20mm bore omplete all as specified and directed.
S&F 20 mm bore Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S&F 15 mm bore Angle cock, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S&F for Steel windows/ventilators with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings, tube light fittings etc complete and removing all retrieved materials such as fitting & fixture from the site and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-standard) PVC insulated and unsheathed electric cable 1100 volts in and including PVC casing and capping of 25 mm and above (as per conductor run )with all fittings/ accessories and including PVC insulated and unsheathed electric cable 1100 volts1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly including 50 mm deep box made of 2nd class hard board of required size and shape etc covered with 3 mm thick plastic laminated sheet ( Make Hylum) for one light point,bell,exhaust point, bulk head, independent controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge.
Description all as per item Srl No. 122.00 here in before but for one 3 pin socket outlet 5 Amp on same board
Description all as per item Srl No. 122.00 here in before but for one 3 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
Description all as per item Srl No. 122.00 here in before but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor (Multi-stranded) insulated and unsheathed electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 1.5 Sqmm copper stranded conductor as continuous earth wire connected to common dolly complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement switch piano flush button single pole one way 5 Amps complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement socket outlet 2 in 1, 5 Amp, flush type complete all as spe cified and as directed by Engr-in-charge.
Supply and fixing in replacement switch, socket combination 2 in 1, 5 Amp, flush type complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement switch socket combination multi purpose 2 in 1, 3 pin 5A/16A, 5 in 1 flush type complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement angular lamp holder, PVC/Polycaronate type with back plate suitable for 12 watt LED bulb for batten fittings complete all as specified and directed by the Engineer-in-Charge.
Supplying and fixing in replacement LED 12 Watt complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement LED batten lights fitting 1x 20W, 220V,AC decorative type including LED tube light connecting up with three core flexible copper conductor cable of suitable size including ceiling rose complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing new energy saving LED Bulk head fitting 10 watt made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK07 as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Eng-In-Charge.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling 6500K including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed by Eng-In-Charge.
M&L for sub main wiring with 2 run of 4 Sqmm FR, PVC insulated, unsheathed and stranded copper conductor cable with and incl 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn drawn through & PVC casing and capping of 25 mm and above incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : 1. The cost of concealed conduit & accessories is deemed to be included in quoted rates. 2. The two run of 4 Sqmm wire and one run of 4 Sqmm wire will be measured as one unit.
Supply and fixing in replacement sheet Metal enclosure single shutter type for DB’s 240 Volts Single Pole and Neutral 8 way with 200 Amps rated bus bar complete including wooden board of required size duly painted with matching colour paint all as specified and as directed by the Engr-in-charge.
Supply and fixing in replacement MCB single pole and neutral 32 to 40 Amps , 240 volt, 10 KA, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement MCB single pole 6 to 32 Amps, 240 volts, 10 KA complete all as specified and as directed by the Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to CBDB’s as specified or indicated including testing on completion .
M&L for point wiring complete for one light point / exhaust fan point / bell point controlled by one 1-way switch/ bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers with and including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as directed. Note : 1. The cost of Metal flush boxes and accessories etc is deemed to be included in quoted rate. 2. In case cutting & chasing of conduit is encountered with any beam / column, the PVC casing & capping or surface conduit will be used to avoid any damage to the RCC portion. 3. No cutting & chasing shall be done on ceiling surface for laying PVC conduit for ceiling fan point wiring etc, hence the PVC casing & capping or surface conduit will be used for the same.
Description all as per Srl item No. 141 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point. Note : The point wiring for power point will not be mixed with light/fan point circuit or not in the same conduit pipe.
S&F Switch piano type, single pole, one way, 15 amps, 230 volts, complete all specified and as directed by the Engineer-in-Charge.
S&F Socket, 6 pin, 5/15 Amp, multipurpose shutter type, 230 volts,complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 1x10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all specified and as directed by the Engineer-in-Charge.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m, complete all as specified and directed by Engineer-in-charge.
Supply and fixing sheet Metal enclosure double shutter type for DB’s 240 Volts Single Pole and Neutral 4 way with 200 Amps rated bus bar complete including wooden board of required size duly painted with matching colour paint acomplete all as specified and as directed by the Engr-in-Charge.
Supply and fixing SPN 40 to 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and neutral in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with stranded conductgor PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections, complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5m and not exceeding 1.5m in depth for laying of electric cable and getting out in hard and dense soil, complete all as specified and as directed by the Engr-in-Charge.
Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed by Engineer-in-charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying, streching & testing of cable in trenches complete all as specified and directed by Engr-in-Charge. Note :- Only punned thickness i.e 18cm shall be measured and paid complete all as specified and directed by Engineer-in-charge.
Supplying & Laying, connecting and testing GI pipe 25 mm bore medium grade including necessary fittings in trenches complete all as specified and directed by Engineer-in-charge.
Supply and fix Gun Metal Gate Valve 25 mm dia with iron wheel head, and all as directed by Engineer - in-Charge.
M&L for Cutting and tapping in 25 mm water mains ( in position) for branch connections complete all specified and as directed by the Engineer-in-Charge.
Description all as per item Srl No.141.00 here-in-before but for one 3 pin socket outlet 5/6 Amps on independent board with 1.5 Sq.mm. FRLS PVC wire and one run of 1.00 Sq.mm. copper cable for earth continuity.
Description all as per item Srl No.141.00 here-in-before but for one 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 2.5 Sq.mm. copper cable for earth continuity.
Mehar Enterprises (BID ID -3336264)
SHANTI ENTERPRISES (BID ID -3336808)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .