Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC | ₹2.1 Cr | L1 | Accepted-AOC Accepted to L1 bidder. |
| 2 | L2₹2.3 Cr+₹19.2 L (9.14%)Rejected-Finance | ₹2.3 Cr+₹19.2 L (9.14%) | L2 | Rejected-Finance Rejected being higher than L1 bidder. |
| 3 | L3₹2.3 Cr+₹19.4 L (9.25%)Rejected-Finance C O BLUE STAR MEDICAL HALL BAGDOGRA DIST DARJEELING WB | BAGDOGRA | DARJEELING | WEST BENGAL | ₹2.3 Cr+₹19.4 L (9.25%) | L3 | Rejected-Finance Rejected being higher than L1 bidder. |
| 4 | L4₹2.4 Cr+₹30.8 L (14.6%)Rejected-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | ₹2.4 Cr+₹30.8 L (14.6%) | L4 | Rejected-Finance Rejected being higher than L1 bidder. |
| 5 | L5₹2.5 Cr+₹36.5 L (17.4%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | ₹2.5 Cr+₹36.5 L (17.4%) | L5 | Rejected-Finance Rejected being higher than L1 bidder. |
Tender Value
₹2.5 Cr
EMD Value
₹3.3 L
Closing Date
17 Oct 2022, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVN OF INFRASTRUCTURE FOR COMMERCIAL POWER SUPPLY FOR MPR AT AF STN BAGDOGRA
2022_MES_547700_1
88442/BAG/E8
Open Tender
Civil Works
Lump-sum
545 days
BAGDOGRA
As per tender documents
7 documents required · 7 mandatory
₹2,000
GE (AF) BAGDOGRA
₹3.3 L
Yes
23 Nov 2022
25 Aug 2022
19 Oct 2022
25 Aug 2022
17 Oct 2022
4 Oct 2022
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V (APPROACH ROAD) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (SOLAR PANEL AND LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -X (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
INTERNAL ELECTRIFICATION S&F LED security light fitting 1 X 30 Watt with integral reflector made of alluminium alloy LM6 with LED driver, lamp, surge protector etc and all accessories pre wired including connection with three core PVC insulated, sheathed copper conductor cable of suitable size complete with GI bracket 1.5 meter long bend to shape of dia 32mm GI medium grade pipe with MS clamp all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator, fan hook and accessories, 230 V, 1200 mm sweep, 5.00 BEE. Five star rated including writing MES No and including connecting up with 3 single core PVC insulated, multistranded copper conductor cables from ceiling rose to fan complete all as specified and directed by Engg-in-charge
S&F Exhaust fan metallic stee body type, 300 mm sweep, single phase, 230V, 50 Hz, 900/950 RPM, heavy duty type with suitable metallic lover, blade, frame & flexibe three core copper conductor cable of suitable size for connetion with ceiling rose including making of hole in wall and making good to the disturbed surface complete with all connecting accessories completed all as specified and as directed.
Supply and fixing concealed distribution box, double door, vertical type, TPN, 415 V, 4 Way of 12 modules, IP 43 suitable for MCCB of 63/100 Amps, 3 P, 16 KA as incomer and MCB SP/ TP as outgoing complete with suitable busbar, netural link, earth link completed all as specified and as directed. Note:- (1) MCCBs/ MCBs shall be measured and paid saperately. (2) Blank space shall be covered with blank plate and cost of the same shall bne included in quoted rate.
Material & Labour Earthing complete with using galvanised steel earth plate electrode 60cm x 60cm x 6mm thick and 4 mm GI wire dia as earthing lead burried directly in ground vertical (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and connected with GI wire 4 mm as earth lead by means of nuts & bolts, check nuts and washers of brass incl PCC pit of 1:3:6 type C-1 cover slab 54 x 54 x 5 cm reinforced with 8mm dia bar TMT @ 150 mm center to center both ways with one handle for lifting made out 8mm dia MS bar with wire mess funnel, 20mm GI tubing medium grade for watering and 15 mm GI tubing GI light grade for protection, test point, tesing on completion all to as shown in electrical plate no 3 of SSR Part-I (2009) all as specified and testing on completion.
EXTERNAL ELECTRIC SUPPLY Supply install commissioning and testing of factory made, powder coated, floor mounted , indoor cubical type LT Feeder Pillar Box(CPRI tested) of size 1200 X 1000 X 450 fabricated out of 2 mm CRCA Sheet and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, Aluminium bus bar of rating 1.5 Times of incomer capacity fixed on porcelain insulator with internal copper wiring with suitable size of Aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with Aluminium lugs, incl. necessary PCC (1 : 3 : 6) type C2 as in foundation all as directed, comprising of the following : - INCOMER : (i) 630 Amp MCCB 4 pole , 50KA (with Thermal Magnetic Protection unit) - 01 No. OUTGOINGS (ii) 500 Amp MCCB 4 pole, 50 KA (with Thermal Magnetic Protection unit) - 01 No. (iii) 100 Amp MCCB 4 pole, 16 KA (with Thermal Magnetic Protection unit) - 01 No. (iv) 63 Amp MCCB 4 pole, 16 KA (with Thermal Magnetic Protection unit) - 01 No. (v) Aluminium Bus bar, 1000 Amp 4 way. ( TPN ) (vi) Digital type Ameter , range 0 to 600 Amp with slector switch and CT. (vii) Digital type Volt meter, range 0 to 500 Volt with slector switch and PT. (viii) LED Indicator lamp RYB. (Set of three) (ix) Danger notice plate of 440/415 volts - 01 Nos
Supply, fixing and laying in trenches and fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, single core 400 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed.
Supply, fixing and laying in trenches and fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, single core 240 Sqmm, with XLPE insulated stranded copper conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed.
Supply and install Supply, installation, testing and commissioning of factory made APFC panel of cap 200 KVAR with 8 steps (4 x 12.5 + 2 x 25 + 2 x 50) WITH MPP-H CAPACITOR AND MCCB AS INCOMER with 7% detuned reactors. APFC panel shall be cubical type, constructed from 14/16 SWG CRCA sheet steel, suitable for indoor installation . Dust/ vermin proof floor mounted. with IP-42 protection . Preparation of surface and treatment by 11 tank process for corrosion proof powder coating with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism and digital volt meter Ampere meter and PF indication meter all as per approved from CPRI. powder coated and as per IS-7032 shade. Angle iron base frame of MS angle 32x32x 5 mm having length 45 cm ( 15 cm in foundation and 30 mm above the foundation to facilitate entry of incoming calce ) shall be provided as per site requirement all as specified and directed. NOTE :- APFC panel drawing shall be approved from the Garrison Engineer before procurement .
Supply and fix 4 Pole MCCB 500 to 630 Amp, 50 Hz ,415 V with rupturing capacity 50 KA complete with Sheet metal enclosure consisted of 3.15 mm MS Sheet with powder coated and fixing arrangement to wall surface and providing necessary opening for incoming and outgoing cable as well as for switching ON/OFF of MCCB and as per site requirement all as specified and directed.
Supply, installation, testing and commissioning of Isolation Transformer of capacity 400 KVA Indoor type, Oil cooled cooper wound complete with standard fittings and accessories with provision of overload, under current protection surge protection against load surges 433/433 volts, 3 Phase, 4 wire with off load tapping on to vary secondary voltage within limit, Insulation class –H and all as per relevant IS of isolation transformer and provision of following and complete all as specified and directed by Engr –in- Charge. (i) Bottom oil filter cum drain valve (ii) Rating diagram and terminal marking plate. (iii) Earthing Terminals -02 Nos (iv) Lifting Plugs -01 set (v) Under carriage with 4 Nos of Bidirectional rollers (vi) Separate neutral bushing shall be brought for earthing Notes : (i) Pre – dispatch inspection at OEM factory premises shall be carried out by Rep of Accepting Officer. (ii) Prior to manufacture, the contractor shall get the general arrangement, drawing and design details of the transformer approved by GE. (iii) After installation of Transformer at site, the pre- commissioning test shall be carried out by rep of Accepting Officer.
Supply, Installation , Testing and commissioning of the copper wound oil cooled indoor type Voltage stabilizer of capacity 400 KVA, confirming to IS 9815 (Part-I) designed for voltage variation between 300 V to 480 Volt and stabilizes at 415 Volt with the following and confirming to BIS 9815 (Part-I) all as specified and directed by Engr-in-Charge. (i) The corrector shall keep the voltage output within +/-1% of the rated output voltage. (ii) The rate of voltage correction shall not be less than 6 Volt per sec without hunting during the operation. (iii) The efficiency shall not be less than 95%. Notes:- Pre –dispatch inspection at OEM factory premises shall be carried out by Rep of Garrison Engineer. (ii) The acceptance test at the site after installation of stabilizer shall be carried out by Rep of Accepting Officer as per the following. Physical Examination, insulation resistance, High voltage test, leakage current test, Provision of earthing, Output Voltage No load current, Measurement of no load losses, Induced voltage test etc.
Supply and installation, testing and commissioning of 300KVA UPS system based on IGBT module with high input power factor & low input TDHI, load adaptability for linear and non linear loads with modular system construction design for power expansion & easy maintenance with safety and protection function including current, voltage thermal abnormality, short circuit etc. Digital controlled independent charger with intelligent battery management system & large touch screen for information display with front access & top & bottom cable connection and each individual module configured with independent controller to avoid single point failure risk with 30 minutes backup as per below specification for radar load application. NOTE :- (a) Factory inspection / Pre- dispatch inspection of the Stabilizer at premises of the OEM shall be carried out by the rep of Garrison Engineer (b) The following test shall be carried out in the factory premises for the approved product:- (i) Load regulation test at 100% load (ii) Overload capacity test (iii) Accoustic noise test (<60 dB at 1 meter). (iv) Battery Discharge test (v) I/P & O/P PF test . (vi) THD test. (vii) DC Voltage test. (viii) Efficiency test & any other test as mandated under IEC/EN standards as applicable
Supply and fix Automatic transfer switch (ATS) with 4 pole for 630A current rating, 50Hz, 415V Automatic/ mannual with Complete protection all as specified and directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amps suitable for fixing arrangement to wall surface as per site requirement all as specified and directed.
Material & labour for conductive concrete marconite earthing by boring of hole of minimum 85mm dia to a depth of 3mtr and inserting GI rod of dia 16mm and length 3mtr and filling with conductive concrete earthing around GI rod of 85mm dia. The complete assembly to be connected to GI strip including nuts, bolts, washer including provision of concrete earth pit PCC (1:2:4) type B1 using 20mm graded stone aggregated with 40mm thick cover with RCC (1:2:4) reinforced XPm (weight not less than 4Kg/Sqm) and frame of angle iron 25mmX3mm with lugs & 6mm dia MS Bar handle with connection to earth test point all as specified and directed by Engr-in-charge. Note: (a)Conductive concrete earthing consisting of 03 Parts of marconite & 01 part of cement by weight with addition of 01 liter of water per 4kg of total mix. (b) Rate of one set is incliuded for the following :- (i) 2 Nos. of CCE GI 16x85x3000 with jointing strip GI. (ii) Service Charges for supervision for installation of conductive concrete earthing by Rep of concerned Earthing expert or OEM . (iii) Transportation charges with packing (Ext Elect - 06 Set and Lightening Protection - 05 Set)
M & L for conductive concrete earthing consisted of galvanized steel earth electrode of length 3000mm, diameter 16mm duly inserted into the precast Earthen /Powder (a bonded mixture of Marconite and cement) a diameter 85 mm duly buried in hole of suitable size to accommodate the electrode and Earthen assembly complete all as specified and directed by Engr-in-charge. Notes:- The rates included shall be inclusive of the following (i) Service charges for supervision at site during installation of concrete conductive earthing by the rep of OEM. (ii) Transport and packing charges upto the site. (iii) A set shall be comprises of 02 Nos of concrete conductive earthing and jointing GI strip. (iv) The record of test result of all earthing shall be kept in record and produced before processing the RAR/ Final Bill. (v) Before locating the place of earthing any of the following tests shall be carried out by the contractor at his own expense. (a) Wenner 4 Pin Method (b) Slope Method (c) Star-Delta Method (d) Two- point method (dead earth method) (e) Clamp on test method.
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI medium grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, Supplying and Filling common salt and charcoal filling in alternate layers sorrounding the earth electode upto 15 mm all sides alongwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion .
M&L for disconnecting of existing Changeover of 600/630Amps, TPN from existing control panel bard by removing all cables and shifting/fixing to CEC wall including provision Sheet metal enclosure consisted of 3.15 mm MS Sheet with powder coated and fixing arrangement to wall surface and providing necessary opening for incoming and outgoing cable as well as for switching ON/OFF of MCCB and as per site requirement all as specified and directed . Note :- Disconnection and Re-Connection of all incoming and outgoing cables including replacement cable gland, lugs/thimbles etc as required at site to be done by the contractor within the quoted rate.
M& L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine for underground cables suitable for 0.4 Mpa working pressure complete all as specified and directed.
SOLAR PANEL AND LIGHTENING PROTECTION Supply and fixing solar pannel system wtih following specifications for 10 to 12 hrs power back up for 500 watt with undermentioned accessories complete all as specified and as directed :- (a) 375 Wp Mono Perc PV Module, Make : Sova Solar - 06 Nos, (b) 12V 150 AH VRLA Battery, Make: Amar Raja - 04 Nos, (c) Fixed Axis PV Mounting Structure HDG 80 micron- 146 KG, (d) 2 KVA , 48V, DC Solar Inverter with MPPT , Make : Agni Power - 01 No, (e) 4 sq mm 1.5 KV DC Solar Cable, Polycab/RR Cable - 42 RM, (f) 4 sq mm 1.1 KV AC flexible Copper cable - 40 RM, (g) 10 sq mm 1.1 KV AC flexible Copper cable - 30 RM, (h) 2P , DC SPD 20 KA - 03 Nos, (j) 15 A , 600 V DC Fuse-06 Nos, (k) 600V DC Fuse Holder - 06 Nos, (l) DCDB IP 43 or above - 01No, (m) 600 V, 4 sq mm TB - 06 Nos, (n) 2P, 20 A, AC MCB - 01 Nos, (o) 2P, AC SPD, TYPE 2 - 02 Nos, (p) ACDB IP 43 or above - 01 Nos, (q) 25 NB PVC Pipe with fittings-55 RM. NOTE :- (i) AMC DOCUMENTS/ SPARE PART LIST FOR MAINTANANCE, GENERAL LINE PLAN LAYOUT AND GUARANTEE / WARRANTEE CERTIFICATE TO BE SUBMITTED FROM OEM BY THE CONTRACTOR AT HIS OWN EXPENSES. (ii) Pre- dispatch inspaction shall be carried out by the rep of Accepting Officer.
Material & Labour Earthing complete with using copper earth plate electrode 60cm x 60cm x 3.15mm thick electrode and 20×3mm copper strip as earthing lead burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl copper strip 32x6mm by means of nuts & bolts, check nuts and washers of brass incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle,earth pit angle iron frame of size 25x25x3mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 40mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate no 3 all as specified and testing on completion. Note:- The earth resistance should be less than one ohms and GI protection pipe and earth lead more than 7.5 RM shall be measure and paid separately.
INTERNAL WATER SUPPLY S & F brass angle stop cock CP high pressure with capstan head long shank screwed down 15 mm dia bore complete all as specified and directed.
AIR CONDITIONING Supply, fixing and commissioning hi wall split units, inverter technology type, indoor/outdoor, five star rating, stelectric driven (Single phase) complete with cordless remote control unit of capacity 2 TR, BEE 5 star rated complete with wall/floor mounted stand for Copper tube condenser out door unit with standard length of copper tubing, insulation and Drain pipe & all accessories all as specified and directed by Engr-in-Charge.
Supply, install and copper wound Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and capaicty of 5.0 KVA complete including prewired three core copper cable 6 Sqmm adequate length complete all as specified and directed. Note :- Stablizers as provided should be inbuilt with 4-6 Sec initial time delay relay.
Supply and fix factory made MS angle AC Stand suitable for mounting Outdoor unit of Split AC OF Capacity 2 TR alongwith MS Fasteners Complete all as specified and directed by Engg-in-charge
B D Raizada Projects Pvt Ltd
NEO BUILDERS
M/S. KUMAR CONSTRUCTION CO.
M/S R. K. INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .