| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹26.4 L+₹2.1 L (8.78%)Rejected-Finance | L2 | Rejected-Finance Other than the lowest bid | |
| 3 | L3₹31.1 L+₹6.8 L (28.2%)Rejected-Finance | L3 | Rejected-Finance Other than the lowest bid |
| Sl No | Description | Qty | Unit | M/S Vinod Kumar L1 | PAUL CONSTRUCTION CO. L2 | Sachdeva and Company L3 |
|---|---|---|---|---|---|---|
| 1.00 | Surface dressing n exc 15 cm deep and getting out in Soft/ Loose soil complete all as specified. | 140 | Sqm | 30 ₹4,200 | 50 ₹7,000 | 25 ₹3,500 Lowest |
| 2.00 | Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m wide deep for foundations, etc or for shafts, wells, cesspits, manholes, pier holes etc n exc 10 Sqm on plan and getting out in ordinary soft/loose soil complete all as specified. | 100 | Cum | 200 ₹20,000 | 100 ₹10,000 Lowest | 150 ₹15,000 |
| 3.00 | M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. | 150 | Sqm | 90 ₹13,500 Lowest | 300 ₹45,000 | 450 ₹67,500 |
| 4.00 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified. | 120 | Sqm | 110 ₹13,200 Lowest | 500 ₹60,000 | 550 ₹66,000 |
| 5.00 | M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified. | 90 | Sqm | 90 ₹8,100 Lowest | 300 ₹27,000 | 450 ₹40,500 |
| 6.00 | M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. | 35 | Sqm | 90 ₹3,150 Lowest | 300 ₹10,500 | 450 ₹15,750 |
| 7.00 | M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified. | 40 | RM | 40 ₹1,600 Lowest | 100 ₹4,000 | 75 ₹3,000 |
| 8.00 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. | 3,200 | Kg | 97 ₹3,10,400 | 100 ₹3,20,000 | 95 ₹3,04,000 Lowest |
| 9.00 | All as per Ser item No 8.00 above but 6mm to 8mm dia. | 1,125 | Kg | 97 ₹1,09,125 Lowest | 100 ₹1,12,500 | 98 ₹1,10,250 |
| 10.00 | All as per Ser item No 8.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified. | 1,300 | Kg | 97 ₹1,26,100 Lowest | 100 ₹1,30,000 | 99 ₹1,28,700 |
Tender Value
₹28.0 L
EMD Value
₹56,080
Closing Date
18 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) JALANDHAR CANTT
KABIR ROAD JALANDHAR CANTT
PROVN OF VOCATIONAL LAB IN KV NO - 03 AT JALANDHAR CANTT UNDER GE (WEST) JRC
2025_MES_709894_1
GE/JAL(W)-76/2024-25
Open Tender
Civil Works
Item Rate
180 days
JALANDHAR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST)
₹56,080
Yes
19 Sept 2025
23 May 2025
25 Jun 2025
23 May 2025
18 Jun 2025
6 Jun 2025
Amount
Surface dressing n exc 15 cm deep and getting out in Soft/ Loose soil complete all as specified.
Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m wide deep for foundations, etc or for shafts, wells, cesspits, manholes, pier holes etc n exc 10 Sqm on plan and getting out in ordinary soft/loose soil complete all as specified.
M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified.
M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified.
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified.
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified.
M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
All as per Ser item No 8.00 above but 6mm to 8mm dia.
All as per Ser item No 8.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified.
M&L for form work with rough finished flat surfaces to sides of concrete foundation, footings, base of columns, raft beams, sides and soffits of foundation and plinth beams and similar work complete all as specified.
M&L for form work with rough finished rectangle surfaces to sides of columns, pillar and posts etc complete all as specified.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelvesincluding sup- ports, overhangs,etc. also splays between floors and beams, etc complete all as specified.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) with rough finished flat surface complete all as specified.
M&L for RCC M-25 (using 20mm graded stone aggregate) design mix as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified.
M&L for RCC M-25 (using 20mm graded stone aggr) design mix as in beams,lintel over 1.5m span etc complete all as specified.
M&L for RCC M-25 (using 20mm graded stone aggr) design mix as in column, pillars, piers, posts and struts etc complete all as specified.
M&L for RCC M-25 (using 20mm graded stone aggr) design mix as in slab supported on wall and roof beams etc complete all as specified.
M&L for brick work with sub class B bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified.
M&L for 15mm thick rendering on wall in cement mortar 1:4 on brick/concrete surface and finishing the surface even and smooth with out using extra cement complete all as specified.
M&L for 15mm thick rendering on wall in cement mortar 1:6 on brick/concrete surface and finishing the surface even and smooth with out using extra cement complete all as specified.
M&L for 10mm thick rendering in CM 1:3 on brick/concrete surface as in ceiling and finishing the surface even and smooth with out using extra cement complete all as specified.
M&L for filling Hardcore under floor with broken brick of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
M& L for Cement concrete type E-2, 1:5:10 using 40mm graded stone aggregate as in foundations filling and mass concrete complete all as specified.
M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggr) as in plinth protection/path finishing the surface even and fair without using extra cement complete all as specified. Note : Plinth protection shall be laid in (1:20) slope. The concrete shall be laid at a stretch not exceeding 3metre in length. Joint gap between adjoining slab, at corners and at junctions of walls shall not exceed 10mm in width and shall be sealed with mastic filling i.e. one part of bitumen 85/ 25 grade mixed with 3 part of sand. Top surface of concrete shall be finished even and smooth without using extra cement. Joints shall be provided at not more than 3 metre interval at corner and as junction of walls.
M&L for 15mm thick rendering (over RCC roof slab) with liquid water proofing as per manufacturer's instruction of approved make : Like : SIKA/Dr Fixit/Fosroc on wall in cement mortar 1:4 on brick/concrete surface and finishing the surface even and smooth with out using extra cement complete all as specified.
M&L for priming surfaces with bituminous primer polymerised primer oil based @ 0.40kg per Sqm complete all as specified.
M&L for applying evenly a tack coat of industrial bituminous 85/25 @ 1.20 Kg per sq mtr including cleaning surfaces complete all as specified.
M&L for APP based polymeric membrance minimum weight not less than 3.0kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150gms/sqm) laid on primed surface by forced application( sealed by flame) with over lap of 10 cm finally it will be finished with a coat of aluminium paint @0.200 Kg/Sqm as per manufactures instruction complete all as specified and directed.
Material & labour for 18-20mm thick machine cut kota stone as in vertical surfaces, rises of steps, skirting, dado and pillers etc set and jointed in neat cement slurry and pointed with grey cement mixed with pigment to match the colour of stone slab laid over and including 10mm thick rendering in cement mortar 1:4 including rubbing and mirror polishing complete all as specified.
M&L for rounding/moulding to edges of Kota stone slabs, marble stone, granite stone slabs on edge, such as in steps, cooking platform , and other similar situations etc complete all as specified.
M&L for White Marble 20mm thick machine cut, bedded jointed and pointed with neat cement slurry and pointed with white cement including cutting and polishing over and including 15 mm thick screed bed in cement mortar 1:6 (Only for Borders lines) complete all as specified.
S&F pressed steel door frame with one or more rebate including necessary fixing lugs, hinges, lock stricking plate of size 125 x60mm complete all as specified.
M&L for PCC Type B0-1:2:4 using 12.5mm graded stone aggregate as in filling of pressed steel frame, hold fasts and similars articles complete all as specified.
S&F 2nd class hardwood glazed and skelton door shutters 35 mm thick divided into squares open rebated and prepared to receive glass, gauge etc edges of framing plain, chamfered, rounded fitted with mitred beads for securing glass etc, size of members as specified in SSR Pt 1 section 8 clause 8.20 (b) supplied and fitted to chowkats with plain, chamfered or rounded mited and rebated bars any numbers complete all as specified.
S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, comercial type on both side complete all as specified.
S&F Butt hinges, medium weight cold rolled mild steel 100 mm size ISI marked complete all as specified.
S&F aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified.
S&F Extruded aluminium alloy handles fabricated type anodised 150mm size complete all as specified.
S&F aluminium alloy anodised sliding door bolts 250 mm long with hasp, staple (bolt type)and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections complete all as specified.
S&F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified.
S&F double legged floor door stopper aluminium alloy body and tongue, with hard drawn steel spring overall length of cover plate 140mm complete all as specified.
S&F mild steel pipe 25 mm dia Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc as approved complete all as specified.
S&F 15mm bore GI tubing medium grade complete fixed to wall and ceiling or laid in floor complete all as specified.
S&F 20 mm bore GI tubing medium grade complete fixed to wall and ceiling or laid in floor complete all as specified.
S&F 500 ltrs PVC rotational moulded polyethylene water storage tanks double layer (cylindrical vertical with closed top ) hoisted and fixed in position complete all as specified.
S&F 20mm bore Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified.
S&F ball float valve PTMT with epoxy coated aluminimum rod for 20 mm bore pipe high pressure with polythelene high density float and complete screwed for iron pipe complete all as specified.
S&F 15mm dia long body Bib taps cast copper alloy with fancy type chromium plated crutch or butterfly handle screwed down, scewed for iron pipes or for brass ferrule complete all as specified.
S&F 15mm dia stop valves/angle valve chromium plated, fancy type with long shank and cup screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified.
M&L for 75mm PVC (SWR) floor trap , plain with CP grating including jointing with solvent cement complete all as specified.
S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls/floor complete all as specified.
S&F 75 mm PVC (SWR) bends complete all as specified.
M & L for applying two coat of synthetic enamelled paint over one coat of pink primer including preparation of new wood surfaces of any description not otherwise described over 10 CM girth or width complete all as specified.
M & L for applying two coat of synthetic enamelled paint over one coat of red oxide primer including preparation of new steel surfaces of any description not otherwise described over 10 CM girth or width complete all as specified.
M & L for applying two coats of white wash on ceiling incl preparation newly plastered surfaces complete all as specified.
Material and labour for preparation of new plastered surfaces of walls and Distempering with two coats with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified.
Material and labour for preparation of new plastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified.
M&L for 25 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cms in soft /loose soil complete all as specified.
Removing excavated material n exc 50 m depositing where directed at a level n exc 1.5m above the starting point complete all as specified.
M&L for Cement concrete type C-2, 1:3:6 ( Using 40 mm graded stone aggregate as in foundations, filling and mass concrete
M & L for 25mm thick Sand cushioning under paver block complete all as specified.
M&L machine pressed precast concrete coloured interlocking paver blocks any shape and size confirming of IS 15658: 2006 of 60mm thick , M-35 laid and jointed with grey cement and pigment.
M&L, for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in coping of parapets and or roof kerbs on roof chamfered on edge incl troweling slightly complete all as specified and directed.
Material and labour for cement concrete foundation 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete and under floor as sub base etc., complete
Material and labour for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge
M&L for PCC 1:2:4 type B-1(using 12.50 mm graded stone aggregate) as in channels/benching of manhole, drain,laid to shape and slope and surfaces finished even and smooth using extra cement, complete including all form work etc all as specified and directed.
M&L coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface over 10 mm thick cement plaster in CM 1:4.
M & L Powder coated aluminium (minimum thickness of powder coating 50 micron) for sliding window shutters with frame, including providing and fixing roller, three track system, locking arrangement fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be minimum 1.5mm thick, smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws where necessary all complete as per architectural drawings and the directions of Engineer-in-charge.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and avg erage with aperature 1.18 mm fixed with tinned tacks, or galvanised wire staples.
S&F framed work such as grills & gates, gratings with ends of bars shouldered on forged in spickes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, rallings, framework of water tanks and similar work conforming to Fe-290 Gde - 165.
S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size Frame size 50 x 100 mm for wardrobe, one or more rebates comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp- ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
S & F Factory Made Solid PVC Moulded Door Shutter With Core free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing.
Supply in fixing sink with drainage board made Stainless steel 1mm thick kitchen or laboratory with plugs, washer and wastes pipe , including bedding in cement mortar on dwarf wall or including fixing cantilever brackets and connecting union pipe, over all size 915mm x 460mm bowl size 410mm x330mm x160mm.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out soft/ lose soil.
M/L 100mm thick cement concrete 1:4:8, type D-2 using 40mm graded stone aggregate.
M & L for concealed point wiring complete with 4 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 4 sqmm , FRLS type , copper multistranded cable as earth wire including mounting of switch/sockets and regulator and including cover plate white colour all as specified and directed for :-One 3 pin socket outlet 15 amps, independent
M & L for concealed point wiring complete with 2.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 2.5 sqmm , FRLS type , copper multistranded cable as earth wire including mounting of switch/sockets and regulator and including cover plate white colour for one 3 pin socket outlet 15 Amps independent all as specified and directed
Supply and fixing flush/piano type switch 1 way 16A,
Supply and fixing flush/piano type socket 1 way 16 amp
M & L for concealed point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire including mounting switch/sockets and regulator and including cover plate white colour all as specified and directed for: One light /fan/cell bell/holder point controlled by one one way switch
One 3 pin socket outlet, 5Amps, independent with other switches
One 3 pin socket outlet 5 amps on same board with other switches.
Supply and fixing piano/flush type switch single pole one way 5 Amps
Supply and fixing flush/piano socket 1 way 6 amp single pole
Supply, installation & commissioning MCB Load Distribution board VTPN 4 way double door, for mounting MCCB/DP/ SP/TP/ MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DP/SP/TP MCB shall be of same make as DB. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified.
Supply and Fix 4 Pole MCCB adjustable type 100 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified.
Supply and fixing sheet metal enclosures for DB's SPN when MBCs to be used 8 way double door complete all as specified.
S&F MCB SPN 40 to 63 Amps rating 240 volts ,10KA 'c' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commisioning complete all as specified.
M&L for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 6 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturbed surfaces of wall as per existing including 6 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed. Note : Two runs of 6 sqmm PVC FRLS multi stranded copper cable wire and One run of 6 sqmm PVC FRLS multi stranded copper cable earth wire and One run (01 meter) PVC conduit of suitable size ISI mark will be measured as one unit length.
M & L for ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified.
M & L for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed. Note : (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
supply and fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
S & F stepped type electronic fan regulator flush type complete all as specified and directed.
S&F LED tube light fitting 20W (Double side) including LED lamp 20W with 2100 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures box type and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.50mm 3 core complete all as specified and directed.
Supply and fixing MCB SP 6-32 Amps 240 voltsSupply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. (i) SP 6 To 32 AMP
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete
M & L river sand in trenches as cable cushioning 8 cm below the cables and 15cm above the cable which is to be punned down to 10m all as specified and directed.only punned thickness will be measured.
Supply and lay burnt bricks sub class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed.
Supply and fixing PVC insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of cap 20 amp complete all as directed and specified.
PAUL CONSTRUCTION CO. (BID ID -3326118)
Sachdeva and Company (BID ID -3328304)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .