| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹20.1 L+₹1.5 L (8.03%)Rejected-Finance | L2 | Rejected-Finance Not Being lowest bidder | |
| 3 | L3₹21.4 L+₹2.8 L (15.1%)Rejected-Finance | L3 | Rejected-Finance Not Being lowest bidder | |
| 4 | L4₹25.5 L+₹6.9 L (37.3%)Rejected-Finance | L4 | Rejected-Finance Not Being lowest bidder | |
| 5 | L5₹27.9 L+₹9.4 L (50.6%)Rejected-Finance | L5 | Rejected-Finance Not Being lowest bidder |
| Sl No | Description | Qty | Unit | ROYAL CONSTRUCTION L3 | shivansh traders L6 | MODI CORPORATION L5 | SHIV SHANKAR MISHRA L7 | City buildcom builders & devlopers L2 | MEDHA ENTERPRISE L4 | PRAGATI ELECTRICALS AND ELECTRONICS L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth: for foundation etc or for manholes, laying of pipe lines,cables,pipes etc in any type of soil and getting out complete all as specified and directed by EIC. | 65 | Cum | 100 ₹6,500 Lowest | 250 ₹16,250 | 200 ₹13,000 | 400 ₹26,000 | 100 ₹6,500 Lowest | 230 ₹14,950 | 200 ₹13,000 |
| 2.00 | Returning filling in, including spreading, leveling watering & well rammng in layers not exc 25 cm thick complete all as specified and directed by EIC. | 58.5 | Cum | 25 ₹1,462.5 Lowest | 50 ₹2,925 | 40 ₹2,340 | 30 ₹1,755 | 80 ₹4,680 | 84 ₹4,914 | 100 ₹5,850 |
| 3.00 | Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & diected. | 6.5 | Cum | 30 ₹195 Lowest | 40 ₹260 | 150 ₹975 | 40 ₹260 | 60 ₹390 | 190 ₹1,235 | 200 ₹1,300 |
| 4.00Taking out existing CI/DI pipe line, of any class including CI fitting with spigot and socket ends and lead joint including burning out lead joints recover in lead and to be relaying after cleaning / insertion of new CI pipes/CI fittings of any class/type of follwing sizes in safe condition for the following sizes :- | ||||||||||
| 4.01 | (a) 80mm bore | 85 | RM | 10 ₹850 Lowest | 40 ₹3,400 | 20 ₹1,700 | 80 ₹6,800 | 30 ₹2,550 | 24 ₹2,040 | 20 ₹1,700 |
| 4.02 | (b) 100 mm bore | 33 | RM | 10 ₹330 Lowest | 50 ₹1,650 | 30 ₹990 | 100 ₹3,300 | 35 ₹1,155 | 27 ₹891 | 30 ₹990 |
| 4.03 | (c ) 150 mm bore | 28 | RM | 10 ₹280 Lowest | 110 ₹3,080 | 60 ₹1,680 | 150 ₹4,200 | 40 ₹1,120 | 54 ₹1,512 | 50 ₹1,400 |
| 4.04 | (d) 200 mm bore | 33 | RM | 10 ₹330 Lowest | 150 ₹4,950 | 80 ₹2,640 | 200 ₹6,600 | 50 ₹1,650 | 76 ₹2,508 | 80 ₹2,640 |
| 4.05 | (e) 250mm bore | 33 | RM | 10 ₹330 Lowest | 150 ₹4,950 | 100 ₹3,300 | 250 ₹8,250 | 50 ₹1,650 | 90 ₹2,970 | 100 ₹3,300 |
| 5.00Refixing CI pipe including fittings with spigot and socketed end/ flanged end, centrifugally cast laid in trenches after cleaning internally and externally, drawing out forigen material/rust complete up to satisfaction of Engr in Charge of following sizes with and including new titon joint for fixing of pipe :- Note :- (i) Earth work , joints and CI Specials/fittings of the pipes shall be measured and paid separately under appropriate item. | ||||||||||
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
22 Jan 2026, 6:00 pmClosed
Shri Ankit Goyal, IDSE
GE Dronachal, Dronachal Top, Neori Hills, Bhopal 462038
REPAIR/ TREATMENT OF GI RAISING MAIN PIPE IN CERTAIN MD/ OTM ACCN UNDER GE DRONACHAL
2026_MES_746814_1
8955/E8
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
180 days
BHOPAL
Class-D, Category a (ii) and as per NIT documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER DRONACHAL
₹70,000
Yes
25 Apr 2026
1 Jan 2026
24 Jan 2026
1 Jan 2026
22 Jan 2026
15 Jan 2026
1 Jan 2026 - 8 Jan 2026
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth: for foundation etc or for manholes, laying of pipe lines,cables,pipes etc in any type of soil and getting out complete all as specified and directed by EIC.
Returning filling in, including spreading, leveling watering & well rammng in layers not exc 25 cm thick complete all as specified and directed by EIC.
Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & diected.
Taking out existing CI/DI pipe line, of any class including CI fitting with spigot and socket ends and lead joint including burning out lead joints recover in lead and to be relaying after cleaning / insertion of new CI pipes/CI fittings of any class/type of follwing sizes in safe condition for the following sizes :-
(a) 80mm bore
(b) 100 mm bore
(c ) 150 mm bore
(d) 200 mm bore
(e) 250mm bore
Refixing CI pipe including fittings with spigot and socketed end/ flanged end, centrifugally cast laid in trenches after cleaning internally and externally, drawing out forigen material/rust complete up to satisfaction of Engr in Charge of following sizes with and including new titon joint for fixing of pipe :- Note :- (i) Earth work , joints and CI Specials/fittings of the pipes shall be measured and paid separately under appropriate item.
(a) 80mm bore
(b) 100 mm bore
(c ) 150 mm bore
(d) 200 mm bore
(e) 250mm bore
Supply , laying and jointing DI iron pipes S/S class K 9 of standard length , internal cement mortar coating an external surface with bituminious paint of the following sizes ISI marked including nut bolt, packing material etc and making the joint leak proof complete all as specified and directed. Note : - (i) Earth work, joint and CI/DI specials/fittings of the pipes shall be measured and paid for separately under appropriate items of Schedule.
(a) 100 mm bore
(b ) 150 mm bore
(c) 200 mm bore
(d) 250mm bore
S&F push on flexible rubber gasket (Tyton) joint suitable for following sizes :-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250mm bore
Cutting of cast iron pipes in position for insertion of new tees , branches, etc for the following sizes complete all as specified and directed :-
(a) 80mm bore
(b) 100 mm bore
(c ) 150 mm bore
(d) 200 mm bore
(e) 250mm bore
S & F for CI/ DI fittings i.e bend (any type, radius and angle) tapers any type, (straight bend including decreasing or double socket etc) Tee pieces single branch,'Y' junction, (all sockets or socket and spigot or flanged) collars, caps and plugs. for spigot socketed pipes Of upto 250vmm size.
M&L for run lead joint for spigot and socketed end CI pipe & fittings complete all as specified incl excavation, returning & refilling and directed by Engr in charge for following :-
(a) 80 mm bore
(b) 100 mm bore
(c ) 150mm bore
(d) 200mm bore
(e) 250 mm bore
M&L for cocking of run lead joint for spigot and socketed pipes and fittings complete incl excavation, returning & refilling, all as specified and directed of following sizes :-
(a) 80mm bore
(b) 100 mm bore
(c ) 150 mm bore
(d) 200 mm bore
(e) 250mm bore
Taking out,sluice valve top cover, repiaring of unserviceable spindle and unserviceable check nut by grinding, machining and putting extra material including complete lathe work and refixing of sluice valve parts after servicing including replacment of gland packing, rubber sheet, nut, bolt,Spindle ,check nut and washer of existing size complete all as specified and directed, of following size:-
(a) 80 mm bore
(b) 100 mm bore
(c ) 150mm bore
(d) 200mm bore
(e) 250 mm bore
Taking out old UNSV Sluice valve & Supply and fix cast iron flanged sluice valve of class 1.6 PN, long body, ISI marked, conf to IS-14846 with stainless steel spindle and hand wheel including nut bolts, rubber gasket complete for installation of valve all as specified and directed by EIC of following size:
(a) 80mm dia
(b) 100 mm bore
(c) 150 mm bore
(d) 200mm bore
(e) 250mm bore
Taking up or down (from wall/trenches/floor) existing GI steel tubing and connections, including cleaning for refixing or removal to store of following sizes:-
(a) 80 mm bore
(b) 50 mm bore
(c) 40 mm bore
(d ) 25 mm bore
(e) 20 mm bore
(f) 15 mm bore
Refixing of old steel tubing and connections in new or old position including cleaning internally and externally, any grade/make in trenches/wall/floor/ceiling including all type of new fittings i.e. sockets, Tee union elbow etc all as specified and directed of follwing size:-
(a) 80 mm bore
(b) 50 mm bore
(c) 40 mm bore
(d ) 25 mm bore
(e) 20 mm bore
(f) 15 mm bore
S&F & laying only GI tubing medium grade ISI Marked with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittings for laid in trenches/wall/ceiling/ floor/ all as specified and directed of following size.
(a) 50 mm bore
(b) 40 mm bore
(c) 25 mm bore
(d) 20 mm bore
(e) 15 mm bore
Drilling and taping cast iron water mains (in position) for branch connections for following size
Taking out UNSV Gun metal globe & S&F Gun metal globe or gate valves, conf to IS 778 with iron wheel head, screwed both ends for iron pipe and fixed in existing or new position for following size:
(a) 50 mm bore
(b) 40 mm bore
(c) 25 mm bore
(d) 20 mm bore
(e) 15 mm bore
S&F in repairs Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 25 mm bore (minimum weight 455 gms) complete all as specified and directed.
M&L for replacment of stainless steel splindle with check nut of existing type & size, including opening, grinding , threading , machning of gun metal gate, replacement of nut, bolt and washer including rubber sheet complete all as specified & directed for following sizes :-
Taking out old mechanical Joint and s& F new MJ DI type K12 of followng size including nut bolt all connecting accessories all specified and directed.
Day to Day Maintance GI pipe line various sizes for minor reparing/rectified and attending the complain of pipe line leakage/float valve reparing of size 15 mm to 50 mm by highly skilled trades man as required at site to complete job with stuiplated time without hampering water supply and making functional including all necessary T & P Complete all as specified and directed at site. Note : - (i) The quoted rate deems to exclude for all excavation & dewatering and new GI fittings of suitable size.(ii) The trades man shall report to E/M complaint cell of AGE E/M Dronachal daily at 8.30 am to take complaints from concern JE E/M . The complaint must be attended on same day in stuiplate time period by providing material required and by deploying sufficient manpower by the contractor. The complaint slip duly singned by the user shall be returened back at the complaint cell with proper feed back in the eveing.(iii) For urgent complaint must be come in holiday.(iv) New GI fittings of suitable size,Yarn & safeda/White lead paid and measured to be separetally .(v) Complaint slips & other stationary required for attending complaint shall be supplied by contractor without any extra cost to the departement.
( a ) 15 mm dia
( b ) 20 mm dia
(c ) 25 mm dia.
(d) 40 mm dia.
(e) 50mm bore
S&F 25 mm GI socket
S&F 25 mm GI Elbow
S&F 25 mm GI Union
S&F 25 mm GI Tee
S&F GI reducer 25 x 20 mm
S&F GI Nipple 25 x 100 mm
S&F 20 mm GI Union
S&F 20 mm GI Tee
S&F GI reducer 15 x 20 mm
S&F GI Nipple 20 x 100 mm
S&F 15 mm GI Union
S&F 15 mm GI Tee
S&F GI reducer 15 x 25 mm
S&F GI Nipple 15 x 100 mm
S&F 20 mm NRV
S&F 25 mm NRV
S&F 15 mm NRV
S&F teflon tap
M&L for maint & cleaning of surrounding areas of water supply installations, pump house, etc by cutting all bushes, shurbs, sharkandas and any other type of vegetations and trees girth upto 30 cm and treeming the earth surface to make good soil pressions removing and disposal of the waste retreat to a distance not exceeding 100 M by deploying Mazdoor/T&P as required and taking all precautions complete all as specified and directed.
Supply only (Calcium Hypo chlorite) 65% -70% Chlorine Content (Calcium based granular disinfectant for water treatment & Swimming poolin factory sealed container/drum) (45 kg packing),complete all as specified and directed. Make - " (PURI CHLOR) " manufactured by Shree Rayalaseem Hi-strength Hypo Ltd or any other equivalent make as approved by E-in-C Branch, New Delhi.
Supply, install, testing of open well-submersible pump set of capacity 3 HP, suction size 65 mm,Delivery size 50 mm,Speed 2800 RPM,3 Phase,frequancy 50 HZ,No of stage one,Head18-24 mtr,Discharge max 9.7 LPS,Pump shaft stainless steel, with & including starter of suitable size/capacity and single core copper cable of 10 sqmm length approx (20 metre) connection from starter to motor complete all specified and directed.
Supply, install, testing of open well-submersible pump set of capacity 0.5 HP, suction size 25 mm,Delivery size 25 mm,Speed 2740 RPM,1 Phase,frequancy 50 HZ,No of stage one,Head12-18 mtr,Discharge max 1.7 LPS,Pump shaft stainless steel, with & including starter of suitable size/capacity and single core copper cable of 2.5 sqmm length approx (20 metre) connection from starter to motor complete all specified and directed.
S&F stainless steel Fountain nozzle,Nozzle Diameter 20 mm,Working pressure 5 Bar all as specfied and directed .
M&L for taking out unserviceable submersible pumping set complete with column pipe any capacity and any type from existing bore well carefully without damaging the p/set including connecting parts and lowering the same after repair including provision of suitable size of nut & bolts with washer and suitable packing for column pipes and connection of submersible cable complete all as directed by Engineer -in-Charge.( NOTE: (1) Chain pully block and clamps etc shall be provided by the contractor. (2) Necessary safety pracaution will be responsibility of the contractor.
Supply,install,commissioing and testing of submersible pump set 10 HP of mim head not less than 130 mtr ,min 15 stage ,motor electric driven 3 phase 415 volt AC,50 Hz,2880 RPM ,high quality abrasion resistance bronze and dynamically balanced impeller complete all as specfied and directed.
Taking out old UNSV Starter and S&F in replacement automatic starter of star delta in sheet metal enclosure type, wall mounting suitable for centrifugal pump /submercible pump/monoblock pump pump of , 3 phase, 415 volt, 50 hz, suitable relay range in 5 to 30 Amp, ML contactor, ML over load relay all including taking out old starter single phase preventer fittngs complete all as specified and directed.
Taking out old submersiblle cable and S&F submersible flat copper cable of size 6 sqmmX3core , 220 volt , 50 Hzall specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.26 MB
WORKLOADNEW.pdf
Additional Documents • 0.33 MB
SOC_8955.pdf
Tender Documents • 0.27 MB
GPSC_8955.pdf
Tender Documents • 0.60 MB
BOQ_836283.xls
BOQ • 0.98 MB
PS_8955.pdf
Tender Documents • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .