Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest and Quoted rates are reasonable | |
| 2 | L2₹30.2 L+₹5,321.77 (0.18%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹33.5 L+₹3.4 L (11.4%)Rejected-Finance BHAVANI KRUPA GANDHI CHOWK NAGPUR | NAGPUR | NAGPUR | MAHARASHTRA | 442302 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹35.5 L+₹5.4 L (18.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹35.9 L+₹5.8 L (19.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
18 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PULGAON
GE PULGAON CAD CAMP PULGAON PIN 442303
Periodical services and certain B/R works in RA at CAD Pulgaon
2024_MES_644331_1
8087/PUL/E8
Open Tender
Civil Works
Item Rate
180 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE PULGAON
₹60,000
Yes
24 Apr 2024
27 Feb 2024
26 Mar 2024
27 Feb 2024
18 Mar 2024
13 Mar 2024
28 Feb 2024 - 12 Mar 2024
Amount
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa and AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed. all as specified and as directed.
S&F in repairs pre-painted galvalume aluminium zinc coating GI based crumpled corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa and AZ-150 as in ridge fixed with self tapping screws dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in ridges complete all as specified and as directed.
S&F in repairs for 6 mm thick asbestos cement corrugated sheet in roofs, walls, etc fixed with L type or J type or cranked hook bolts complete all as specified and as directed.
Dismantling of timber scantlings 40 sq cm and over in section in any position,framed work complete all as specified and as directed.
Dismantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section unframed works complete all as specified and as directed.
M L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates grade of steel Fe-290(Gde E 165)
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified & directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directe incuding necessary formwork required complete all as specified and as directed.
M&L preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide complete all as specified and directed.
M&L preparation of old or new surfaces, plastered or un-plastered surfaces by brooming down or steel wire brushing, scraping down smoke shoot, mould mass and efflorescent salts and trading oil and greasy spots etc and applying one coat of white wash on walls and all as specified and directed.
M&L preparation of old surfaces, plastered or un-plastered surfaces by brooming down or steel wire brushing, scraping down smoke shoot, mould mass and efflorescent salts and trading oil and greasy spots etc and applying two coat of white wash on walls and all as specified and directed.
All as above here in before but on ceiling.
M&L for washing, rubbing down and stopping of distempered and painted surfaces of walls including cornices, pillasters etc and applying one coat of oil bound distemper on walls all as specified and directed .
All as above here in before but on ceiling.
M&L for complete removal of existing treatement from plastered surfaces finished even & smooth, preparatory to distempering and applying two coats of oil bound distemper over a coat of Chalk whiting on walls all as specified and directed.
M&L preparation of old plastered/unplastered surfaces of wall and applying 2mm coat of wall care putty on surfaces of wall complete all as specified and as directed.
M&L for washing, rubbing down and stopping of old surfaces of walls incl cornics, pillastar and applying one coat of cement base paint on wall all as specified and directed . Note : Scaffoldings to be used for height more than 3m
M&L for complete removal of existing treatement from plastered surfaces finished even & smooth of old surfaces of walls incl cornics, pillastar and applying two coat of cement base paint over a coat of Chalk whiting on wall all as specified and directed . Note : Scaffoldings to be used for height more than 3m
M&L for preparation of old painted surfaces of wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed .
All as above here in before but n exc 10 cm width or girth.
M&L for preparation of old painted surfaces of steel and iron work over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified.
All as above here in before but n exc 10 cm width or girth.
M&L for preparation of old painted surfaces and applying one coat of black paint back ground n exc 0.10sqm each (incl cutting in edges) to receive writing on wall plastered surfaces all as specified and as directed
M&L for writing letters or figures (Block, Roman, Italic or Indian) n exc 30cm height) with approved colour paint all as specified and as directed.
M&L for washing, rubbing down and stopping of old plastered/ unplastered surfaces of walls including cornices, pillasters etc and applying one coat of acrylic emulsion paint on walls all as specified and directed. Note : Scaffoldings to be used for height more than 3m
M&L for complete removal of existing treatment and applying two coats of acrylic emulsion paint over one coat of primer on plastered surface of walls of any description all as specified and as directed. Note : Scaffoldings to be used for height more than 3m
M&L for Brick work with fly ash bricks straight or curved on plan exc 6m in radius but built in 1:6 cement mortar including demoltion of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking down cement plaster on bricks or stone walls etc including raking out joints racking for key scrubbing down with water etc.
M&L for rendering 15 mm thick in CM 1:6 on faces of stone, brickwork or concrete surfaces (internal), finished even and smooth without using extra cement etc complete all as specified and as directed.
M&L for 15mm thick rendering in two coats on stone/ brick/ concrete surfaces (external) finished even and smooth without using extra cement etc. 1st coat 10 mm thick in CM 1:6 and 2nd coat 5mm thick in CM 1:4 mix with water proofing compound as per manufacturer instructions complete all as specified and as directed. Note : WPC shall measured and paid Seprately
Supply only Integral water proofing Compound
M&L in repairs for 15 mm thick rendering in patches n exc 3.00 sqm in each patch in CM 1:6 over brick work,stone masonary or concrete surfaces finished even and smooth all as specified and as directed.
M&L in repairs for 10 mm thick rendering in patches n 3 sqm in each patch in CM 1:4 over brick work,stone masonry or concrete surfaces finished even and smooth all as specified and as directed.
M&L in repairs for 5mm th rendering in patches to sides and soffits of chajjas, balconies, and the like with plastering in CM 1:3 over brick work,stone masonary or concrete surfaces finished even and smooth all as specified and as directed.
M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of wall putty to achieve smooth surface complete all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. Note : Scaffoldings to be used for height more than 3m
M&L preparation of new plastered surfaces, applying three coats of white wash on walls.
M&L preparation of new plastered surfaces, applying two coats of acrylic emulsion paint over one coat primer of any description all as specified and as directed. Note : Scaffoldings to be used for height more than 3m
M&L of machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade including 50 mm sand cushioning with grey cement and pigment including demoltion of existing and disposal of rubbish complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in base for path/paving/hard standing including demoltion of existing damaged PCC and disposal of rubbish complete all as specified and as directed.
M&L in repairs Acoustic Board/tile (wood fiber cement composite) of 20/25 mm thick of size 600x600/ 600x1200mm having excellent noise absorption of 1 NRC as per ISO: 354, meets Fire Ratings as per BS 476 Part 5,6 and 7 class 1 and P, water resistant and thermal insulated. Installed on G.I studs 600x600mm center to center 2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm also to be fixed on walls with a backing of 50mm absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results.
Laxmi Paper Agencies
M/s Dara Constructions, Pulgaon
Chhabra Enterprises
SHREE SIDDHIVINAYAK TRADERS
M/S Ramakant Chourasia
M/s VILAS RATAN MENDHE
M/S Maa Durga Constructions,Pulgaon
M/S JAI BHAWANI CONSTRUCTIONS
SHRI RANI SATI TRADERS
NEELKAMAL BUILDERS
Bidder Name
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
M/s VILAS RATAN MENDHE
M/S Ramakant Chourasia
M/s Dara Constructions, Pulgaon
M/S Maa Durga Constructions,Pulgaon
M/s Prakash Agencies
M/S JAI BHAWANI CONSTRUCTIONS
NEELKAMAL BUILDERS
Chhabra Enterprises
Laxmi Paper Agencies
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .