Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.6 LAccepted-AOC | ₹51.6 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹53.8 L+₹2.2 L (4.31%)Rejected-Finance | ₹53.8 L+₹2.2 L (4.31%) | L2 | Rejected-Finance Higher rate to the contractor |
| 3 | L3₹54.5 L+₹2.9 L (5.56%)Rejected-Finance | ₹54.5 L+₹2.9 L (5.56%) | L3 | Rejected-Finance Higher rate to the contractor |
| Sl No | Description | Qty | Unit | Sham Lal Contractor L3 | SHRI RAM CONTRACTOR AND SUPPLIER L2 | YASHRISHI ENGINEERING L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and erection of recessed type 42 watt full window glare free opal diffuse LED panel of size 595 x 595 mm suitable for Armstrong/POP/GB ceiling with M.S. powder coated white housing. Total system lumens of 42 watt LED should be 5100 or above in cool day light (5600K to 6500 K), power factor 0.95 CRI (Ra) 80, LED lamp efficiency)100 lm/W, Average life 50000 hours complete with all accessories as required with connections Make Havells, Philips, Bajaj (Industrial) | 21 | Each | 2,500 ₹52,500 | 2,450 ₹51,450 | 2,410 ₹50,610 Lowest |
| 2.00 | Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410-A/R-32 suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:-(i) Cooling coil row -3 Each.(ii) Air flow (CMH)1450 cum/ hr.(iii) Sound level (H/M/L)- 41/38/34/25(silent mode)(iv) Louvers swing- 3D plus 3D Auto etc. complete in all respect MAKE :- O General/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge | 8 | Each | 79,000 ₹6,32,000 | 74,000 ₹5,92,000 Lowest | 75,000 ₹6,00,000 |
| 3.00 | Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge complete in all respect. (NS) Make:-Voltstar,V-Guard,Microtek | 8 | Each | 7,800 ₹62,400 Lowest | 12,500 ₹1,00,000 | 8,500 ₹68,000 |
| 4.00 | Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts and bolts etc. of best quality complete in all respect | 13 | Each | 700 ₹9,100 Lowest | 800 ₹10,400 | 700 ₹9,100 Lowest |
| 5.00 | Providing and fixing UPVC pipes of 25 mm size for disposal of condensed water drainage from indoor unit to nearest disposal point in toilet/ outside as per direction of the EIC / consultant complete in all respect.
Make:- Supreme/Prince/Finolex | 32 | Metre | 90 ₹2,880 | 50 ₹1,600 Lowest | 70 ₹2,240 |
| 6.00 | Providing and fixing extra copper tubing/refrigerent pipe for above split air conditioners consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length | 32 | Metre | 780 ₹24,960 | 200 ₹6,400 | 100 ₹3,200 Lowest |
| 7.00 | S.I.T.C of push ON/OFF type 25A modular type motor starter switch (white colour) for AC`s including the cost of petty material required to complete the job upto entire satisfaction of Engineer-in-charge. | 8 | Each | 560 ₹4,480 | 550 ₹4,400 | 450 ₹3,600 Lowest |
| 8.00 | Removing of existing damaged false ceiling at all height including tiles and frame work etc. and shifting the dismantalled material to maintenance store, complete in all respects as directed by the Engineer-in-charge. | 112.32 | Sqm | 165 ₹18,532.8 | 150 ₹16,848 Lowest | 170 ₹19,094.4 |
| 9.00 | Removing of existing aluminium shutter including its floor hinges, opening of fixed glass panels/ boards, dismantling the all parts of aluminium door including removing its glass panes for preparing door shutters of reduced size, reassembling the door members to prepare door and refixing the door shutter in position including floor hinges, complete in all respect as directed by Engineer-in-charge. | 74.16 | Sqm | 1,450 ₹1,07,532 | 200 ₹14,832 Lowest | 1,000 ₹74,160 |
| 10.00 | U-Type Wall Bench Size:- L 21180 ±10 mm x W 750 ± 10 mm x H 890 ±10 mm (Wall Bench-1) consisting of following: 16 Nos. C-Frame Structure in 60 ±3 x 30 ±2 x 2 ±0.2 mm thick hollow pipe construction 2 Nos. 850 ±10 mm corner unit assemble with front cover panel. The unit should be complete in all aspects with Z Black 17 mm granite ( plus /-1 mm) 16 Nos. L-750 ±10 mm wide storage module with one drawer (with Hettich/Hefele Sliding channel) two shutters, SS304 Handles and SS304 Butt Hinges with roller catcher. The modules should be complete in all aspects. 6 Nos. 600 ±10 mm wide storage module with one drawer (with Hettich/Hefele Sliding channel) two shutters, SS304 Handles and SS304 Butt Hinges with roller catcher. The modules should be complete in all aspects. 8 Nos. 750 ±10 mm Overhood wall cabinet dimensions 750 mm (W) x 600 mm (H) x 200 mm (D) with two shutters, one adjustable shelf with 5 mm glass view in shutter. 2 Nos. 750 ±10 mm wide sink module with two shutters, SS304 Handles and SS But Hinges with roller catcher. 2 Nos. Single piece moulded 5mm PP sink (L 460 x W 450 x D 315) ±20 mm. 2 Nos. Worktop mounted three-way water tap with swan neck spout brass epoxy coated 2 Nos. Peg Board in Phenolic resin construction with 23±3 Nos. PP peg 17 Nos. Worktop mounted electrical raceway units for housing 6 Module electrical plate in GI powder coated 0.8mm GI sheet metal with powder coating 60-70 microns. 17 Nos. 6 Module electrical plate complete including cost of copper wiring (approximate size) to be tapped from nearest electrical nitch as decided by Engineer-In-charge complete (One plate includes) • 5 Amp electrical sockets – 1 No. • 15 Amp electrical sockets – 1 No. • 5 Amp electrical switch – 1 No. • 15 Amp electrical switch – 1 No. NOTE:- Above nomenclature may be read in conjunction with specification provided in the bid Document. | 1 | Each | 9,02,205 ₹9,02,205 Lowest | 10,00,000 ₹10,00,000 | 9,56,000 ₹9,56,000 |
Tender Value
₹56.8 L
EMD Value
₹1.1 L
Closing Date
27 Jan 2026, 5:00 pmClosed
Dinesh Kumar
EO-cum-CE Office
The proposal under consideration covers the cost of civil, electrical, public health and modular lab, furniture works. Provision mainly for following items job has been made in this estimate
2026_HRY_497807_1
2026A3B8F935 66A9 4A1A BA9C 5BE6C2EC7348829CCS
Open Tender
Civil Works
Works
180 days
Hisar
As per CBD
2 documents required · 2 mandatory
₹5,000
₹1.1 L
Yes
29 Aug 2026
19 Jan 2026
28 Jan 2026
21 Jan 2026
27 Jan 2026
21 Jan 2026
21 Jan 2026 - 23 Jan 2026
Supply and erection of recessed type 42 watt full window glare free opal diffuse LED panel of size 595 x 595 mm suitable for Armstrong/POP/GB ceiling with M.S. powder coated white housing. Total system lumens of 42 watt LED should be 5100 or above in cool day light (5600K to 6500 K), power factor 0.95 CRI (Ra) 80, LED lamp efficiency)100 lm/W, Average life 50000 hours complete with all accessories as required with connections Make Havells, Philips, Bajaj (Industrial)
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410-A/R-32 suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:-(i) Cooling coil row -3 Each.(ii) Air flow (CMH)1450 cum/ hr.(iii) Sound level (H/M/L)- 41/38/34/25(silent mode)(iv) Louvers swing- 3D plus 3D Auto etc. complete in all respect MAKE :- O General/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge complete in all respect. (NS) Make:-Voltstar,V-Guard,Microtek
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts and bolts etc. of best quality complete in all respect
Providing and fixing UPVC pipes of 25 mm size for disposal of condensed water drainage from indoor unit to nearest disposal point in toilet/ outside as per direction of the EIC / consultant complete in all respect. Make:- Supreme/Prince/Finolex
Providing and fixing extra copper tubing/refrigerent pipe for above split air conditioners consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length
S.I.T.C of push ON/OFF type 25A modular type motor starter switch (white colour) for AC`s including the cost of petty material required to complete the job upto entire satisfaction of Engineer-in-charge.
Removing of existing damaged false ceiling at all height including tiles and frame work etc. and shifting the dismantalled material to maintenance store, complete in all respects as directed by the Engineer-in-charge.
Removing of existing aluminium shutter including its floor hinges, opening of fixed glass panels/ boards, dismantling the all parts of aluminium door including removing its glass panes for preparing door shutters of reduced size, reassembling the door members to prepare door and refixing the door shutter in position including floor hinges, complete in all respect as directed by Engineer-in-charge.
U-Type Wall Bench Size:- L 21180 ±10 mm x W 750 ± 10 mm x H 890 ±10 mm (Wall Bench-1) consisting of following: 16 Nos. C-Frame Structure in 60 ±3 x 30 ±2 x 2 ±0.2 mm thick hollow pipe construction 2 Nos. 850 ±10 mm corner unit assemble with front cover panel. The unit should be complete in all aspects with Z Black 17 mm granite ( plus /-1 mm) 16 Nos. L-750 ±10 mm wide storage module with one drawer (with Hettich/Hefele Sliding channel) two shutters, SS304 Handles and SS304 Butt Hinges with roller catcher. The modules should be complete in all aspects. 6 Nos. 600 ±10 mm wide storage module with one drawer (with Hettich/Hefele Sliding channel) two shutters, SS304 Handles and SS304 Butt Hinges with roller catcher. The modules should be complete in all aspects. 8 Nos. 750 ±10 mm Overhood wall cabinet dimensions 750 mm (W) x 600 mm (H) x 200 mm (D) with two shutters, one adjustable shelf with 5 mm glass view in shutter. 2 Nos. 750 ±10 mm wide sink module with two shutters, SS304 Handles and SS But Hinges with roller catcher. 2 Nos. Single piece moulded 5mm PP sink (L 460 x W 450 x D 315) ±20 mm. 2 Nos. Worktop mounted three-way water tap with swan neck spout brass epoxy coated 2 Nos. Peg Board in Phenolic resin construction with 23±3 Nos. PP peg 17 Nos. Worktop mounted electrical raceway units for housing 6 Module electrical plate in GI powder coated 0.8mm GI sheet metal with powder coating 60-70 microns. 17 Nos. 6 Module electrical plate complete including cost of copper wiring (approximate size) to be tapped from nearest electrical nitch as decided by Engineer-In-charge complete (One plate includes) • 5 Amp electrical sockets – 1 No. • 15 Amp electrical sockets – 1 No. • 5 Amp electrical switch – 1 No. • 15 Amp electrical switch – 1 No. NOTE:- Above nomenclature may be read in conjunction with specification provided in the bid Document.
ISLAND Bench Size:- L 3000 ±10 mm x W 1500±10 mm x H 900±10 mm (ISLAND BENCH-1) consisting of following: 6 Nos. C-Frame Structure in 60 ±3 x 30 ±2 x 2 ±0.2 mm thick hollow pipe construction 8 Nos. L-750 ±10 mm wide storage module with one drawer (with Hettich/Hefele Sliding channel) two shutters, SS304 Handles and SS304 Butt Hinges with roller catcher. The modules should be complete in all aspects. 2 Nos. Two Tie Reagent Rack 300 width with reagent pillar height 600 mm having slotting for adjustable shelves made from 12 mm thick HPL acid resistant laminate/PP Sheet. Electrical trucking unit both side for housing 6 module plate with switch and sockets. 8 Nos. 6 Module electrical plate complete including cost of copper wiring (approximate size) to be tapped from nearest electrical nitch as decided by Engineer-In-charge complete (One plate includes) • 5 Amp electrical sockets – 1 No. • 15 Amp electrical sockets – 1 No. • 5 Amp electrical switch – 1 No. • 15 Amp electrical switch – 1 No. 528 sqm. Z Black 17 mm granite ( plus /- 1 mm) including the various size of connecting sets as per the approved design and description in the specification 1251 Sqft. Providing and laying Ceramic glazed floor tiles of size 600x600mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete (HSR-10.57) 828 Sqft. Providing and fixing 1st quality Ceramic glazed wall tiles conforming to ISI15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete (HSR-10.62) 15 Nos. Stools- Made of high-quality materials. Designed using state-of the art technology. 10 Nos. Chairs-tested and certified to meet BIFMA safety and durability standards and high-quality mesh backrest NOTE:- Above nomenclature may be read in conjunction with specification provided in the bid Document.
Providing and fixing U-Type Wall Bench Size : L 16230 ±10 mm x W 750 ±10 mm x H 890 ±10 mm (WALL BENCH-1) consisting of following: 12 Nos. C-Frame Structure in 60 ±3 x 30 ±2 x 2 ±0.2 mm thick hollow 2 Nos. 850 ±10 mm wide corner unit assembly with front cover panel. The unit should be complete in all aspects with Z Black 17 mm granite ( plus /- 1 mm) 12 Nos. L -750 ±10 mm wide storage module with one drawer (with Hettich/Hefele Sliding channel) tow shutters, SS304 Handles and SS304 Butt Hinges with roller catcher. The modules should be complete in all aspects. 4 Nos. 600 ±10 mm wide storage module with one drawer (with Hettich/Hefele Sliding channel) two shutters, SS304 Handless and SS304 Butt Hinges with roller catcher. The modules should be complete in all respect. 16 Nos. 750 ± 10 mm Overhood wall cabinet dimensions 750mm (W) x 600mm (H) x 200 mm (D) with two shutters, one adjustable shelf with 5mm glass view in shutter. 1 No. 750 ± 10 mm wide sink module with two shutters, SS304 Handless and SS Butt Hinges with roller catcher 1 No. Single piece moulded 5mm PP sink (L 460 x W 450 x D 315) ±20 mm. 1 No. Worktop mounted three way water tap with swan neck spout brass epoxy coated. 1 No. Peg Board in Phenolic resin construction with 23 ±3 Nos. PP pegs. 15 Nos. Worktop mounted electrical raceway unit for housing 6 module electrical in GI powder coated 0.8 mm GI sheet metal with powder coating 60-70 microns 15 Nos. 6 Module electrical plate complete including cost of copper wiring (approximate size) to be tapped from nearest electrical nitch as decided by Engineer-In-charge complete (One plate includes) • 5 Amp electrical sockets – 1 No. • 15 Amp electrical sockets – 1 No. • 5 Amp electrical switch – 1 No. • 15 Amp electrical switch – 1 No. NOTE:- Above nomenclature may be read in conjunction with specification provided in the bid Document.
ISLAND Bench Size:- L 3000±10 mm x W 1500±10 mm x H 890 ±10 mm (ISLAND Bench-1) consisting of following: 6 Nos. C-Frame Structure in 60 ±3 x 30 ±2 x 2 ±0.2 mm thick hollow pipe construction 8 Nos. L -750 ±10 mm wide storage module with one drawer (with Hettich/Hefele Sliding channel) two shutters, SS304 Handles and SS304 Butt Hinges with roller catcher. The modules should be complete in all respects. 2 Nos. Two Tie Reagent Rack 300 width with reagent pillar height 600 mm having slotting for adjustable shelves made from 12 mm thick HPL acid resistant laminate/PP Sheet. Electrical trucking unit both side for housing 6 module plate with switch and sockets 8 Nos. 6 Module electrical plate complete including cost of copper wiring (approximate size) to be tapped from nearest electrical nitch as decided by Engineer-In-charge complete (One plate includes) • 5 Amp electrical sockets – 1 No. • 15 Amp electrical sockets – 1 No. • 5 Amp electrical switch – 1 No. • 15 Amp electrical switch – 1 No. NOTE:- Above nomenclature may be read in conjunction with specification provided in the bid Document.
ISLAND Bench Size:- L 3000 ±10 mm x W 1500±10 mm x H 900±10 mm (ISLAND BENCH-1) consisting of following: 6 Nos. C-Frame Structure in 60 ±3 x 30 ±2 x 2 ±0.2 mm thick hollow pipe construction 8 Nos. L-750 ±10 mm wide storage module with one drawer (with Hettich/Hefele Sliding channel) two shutters, SS304 Handles and SS304 Butt Hinges with roller catcher. The modules should be complete in all aspects. 2 Nos. Two Tie Reagent Rack 300 width with reagent pillar height 600 mm having slotting for adjustable shelves made from 12 mm thick HPL acid resistant laminate/PP Sheet. Electrical trucking unit both side for housing 6 module plate with switch and sockets. 8 Nos. 6 Module electrical plate complete including cost of copper wiring (approximate size) to be tapped from nearest electrical nitch as decided by Engineer-In-charge complete (One plate includes) • 5 Amp electrical sockets – 1 No. • 15 Amp electrical sockets – 1 No. • 5 Amp electrical switch – 1 No. • 15 Amp electrical switch – 1 No. NOTE:- Above nomenclature may be read in conjunction with specification provided in the bid Document.
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
[10.63.2]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm [Through Rate]
[10.67.2]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm [Through Rate]
[10.70.2]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 2. Size of Tile 600x600 mm [Through Rate]
[10.9]Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. [Through Rate]
[11.33]Pebble dash plaster up to 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. [Through Rate]
[11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete [Through Rate]
[11.6.2]15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) [Through Rate]
[11.65.1]Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work [Through Rate]
[11.67.1]Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer [Through Rate]
[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate]
[20.26.2]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall [Through Rate]
[20.26.3]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 3. 34.29 cm thick wall [Through Rate]
[20.71.2]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 2. 56" (1400mm) [Through Rate]
[21.100.1]Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 1. 40 mm dia pipe [Through Rate]
[21.100.2]Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 2. 100 mm dia pipe [Through Rate]
[22.166.1.1]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]
[22.182]Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet and over flow pipes. The base support i/c fittings and fixtures for tank shall be paid separately. [Through Rate]
[22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate]
[22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete [Through Rate]
[22.222.2.4]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete [Through Rate]
[22.85.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate]
[22.85.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate]
[22.85.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 5. 40 mm nominal outer dia Pipes [Through Rate]
[22.86.1]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes [Through Rate]
[22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate]
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate]
[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
[23.3.1.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A [Through Rate]
[23.3.4.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group A [Through Rate]
[23.3.5.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group A [Through Rate]
[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.3.6.4]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate]
[23.3.6.6]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate]
[23.8.10.6]FITTING AND ACCESSORIES 10.6. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules [Through Rate]
[23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate]
[23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type [Through Rate]
[23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch [Through Rate]
[23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket [Through Rate]
[23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate]
[30.22]Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. [Through Rate]
[30.88.1]Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 1. For pipes 100 to 250 mm diameter [Through Rate]
[5.44]Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. [Through Rate]
[5.7.4]Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar [Through Rate]
[5.70]Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. [Through Rate]
[7.22.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
[9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase [Through Rate]
[9.46.3]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant board [Through Rate]
[9.48]Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. [Through Rate]
[9.55.5]Supplying and fixing in position 60 cm long G.I. pipe class ‘B’ spouts in chajjas and cantilevers 5. 50 mm internal dia [Through Rate]
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_576362.xls
BOQ • 0.35 MB
777978Z147545.pdf
Additional Documents • 0.23 MB
OT0147545.pdf
Other Document • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .