Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | Admitted-Finance |
| 2 | Admitted-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | Admitted-Finance |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
15 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PATIALA
HQ CWE Bldg No 26 New Lal Bagh Patiala
REPAIR/ MAINT OF ELECTRIC INSTALLATION AND DISTRIBUTION SYSTEM AT MIL STN NABHA UNDER GE SOUTH PATIALA
2020_MES_352817_2
8320/PAT/T-25/E8
Open Tender
Electrical and Maintenance Works
Lump-sum
180 days
Nabha
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE South Patiala
₹38,000
Yes
20 Aug 2020
21 Jul 2020
17 Aug 2020
21 Jul 2020
15 Aug 2020
3 Aug 2020
21 Jul 2020 - 28 Jul 2020
60 days
Amount
Schedule 'A'Section-I (EXTERNAL ELECTRIFICATION WORKS)
Total amount of Sch 'A' Sec I (external Electrification Works)
Schedule 'A'Section-II (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Taking up/down worn out/damaged/unserviceable XLPE /PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 1100 Volt grade from trench/duct/pole/wall/pipes etc. complete all as specified and directed.
Restringing, tightening of ACSR conductor of any size and type and GI continuous earth conductors of any size, maintaining standard sag including providing aluminum binding wire on LT over head lines and fixing of GI conductor complete all as specified and directed.
Dismantling and disconnecting of old unserviceable Burnt MCCBs of size 63 to 500 Amps complete all as directed.
Supply and fix in repair MCCB 4 pole, 415 V, Adjustable type 100 Amp with braking capacity 25 KA.
Supply and fix in repair MCCB 4 pole, 415 V, Adjustable type 315 Amp with braking capacity 36 KA .
Material and labour for Cutting of road/ hard standing up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 to much the existing surface level complete all as directed.
Taking down existing old U/s LT panel any type any size all as directed by Engr-in-charge
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32X6mm thick by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
M&L for relacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4 mm thick by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frame 40 x 40 x 6mm and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
Material and labour for servicing of HT 11 KV VCB 400Amps alongwith CTs/PTs of any make and type by drawing out breaker assy from panel and carry out the following maintenence/repair work- (a) Cleaning/decarbonizing of all fixed and moving contacts, levers, springs by using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc, (b) Adjustment of the trolley / racking mechanism , (c) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, automatic shuttering system, necessary brazing, turnig, polishing of main and auxiliary contact, demoisturing of insulators, etc. (d) Testing of tripping performance of HT VCB by using primary & secondary high current injection, test including measuring of CT ratio and polarity all as directed. (e) Resetting of tripping relay including interlocking system. (f) Checking of operating mechanism and its adjustments, measurements of the mechanical clearances of operating mechanism, internal wiring circuit, tightening of all electrical connections including removing moisture content complete all as directed.
Supply and Replacement of VCB indication lamps LED type as per existing colour code (as required) and making all connection complete all as specified and directed.
Painting to existinfg PCC poles 9 / 11 meters long with one coat of synthetic enamel paint in alternate strips of yellow and black colour 30 cm height each total 05 Nos commencing from the top of PCC coping, including painting of cross arms, nut bolts, clamps etc as fixed on pole with two coats of aluminium paint and marking pole No with paint as per approved pattern complete all as specified and directed. Note : Numbering shall be hand written only, size of letter 100 x 10mm(Height x Width).
Disconnecting carefully of HT/LT connectiones, taking down transformer 63 to 400KVA 11KV/415V from mounting platform and transporting to authorised workshop (as per direction of Engr-in-charge) to carryout the following repair/replacement :- (a) Opening of transformer, taking out the core and coil from housing, drain out oil in drum for reuse, after dehydration. (b) Rewinding of HT/LT coil of transformer with super enamelled copper/ aluminium winding wire of appropriate guage varnishing drying wrapping at the top connections with impregnated tape refixing the core and coil assembling upto the transformer housing including replacing gasket(Approx 40Kg copper Coil) including varnishing and drying the complete coils and fix into position complete all as specified and as directed. (c) Cleaning washing heating the coil in vacum to achieve the coil insulation upto minimum 200 mega ohm. (d) Dehydration of transformer oil to achieve the dielectiric strenght upto 40KV at 2.5mm gap (Approx 200 Ltrs). (e) Replacement of HT/LT bushing with bushing rod. (f) Assembling and refixing the transformer at site after transporting from workship, testing commissioning complete all as specified and directed. Note :- (i) The cost of crane charges for loading/unloading of transformer from site and factory incl transportation , labour charges from site to factory and back are deemed to be included in the unit quoted rate. (ii) Rewinding material (Cu/ Al), Spare parts and new transformer oil if any required for topping up shall be measured and paid separately from serial item No. 53 to 63 here in after.
Supply only Double paper coating(D.P.C) HT insulated copper winding wire of existing guage/size including varnishing and drying the complete coils and fix into position complete all as specified and as directed. Note : Actual weight of bare copper conductor shall be measured and paid.
Supply only Double paper coating(D.P.C) LT insulated copper winding wire of existing guage/size including varnishing and drying the complete coils and fix into position complete all as specified and as directed. Note : Actual weight of bare copper conductor shall be measured and paid.
Supply only HT bushing suitable for 63 to 400 KVA outdoor/ indoor type transformer - (set of three) complete all as specified and as directed.
Supply only LT bushing suitable for 63 to 400 KVA outdoor/ indoor type transformer - (set of three) complete all as specified and as directed.
Supply only 12mm dia LT bushing rod with superior quality bushing insulator suitable for 63 to 400 KVA outdoor/ indoor type transformer - (set of three) complete all as specified and as directed.
Supply only 20mm dia HT bushing rod with superior quality bushing insulator suitable for 63 to 400 KVA outdoor/ indoor type transformer - (set of three) complete all as specified and as directed.
Supply only silica gel suitable for 63 to 400 KVA outdoor/ indoor typet transformer complete all as specified and as directed.
Supply only inspection glass and gasket of conservator suitable for 63 to 400 KVA outdoor/ indoor type ransformer complete all as specified and as directed.
Supply only transformer oil confirming to IS-335-1993 at site for topping up to oil level transformer of existing transformer installed at various location having dielectric strength not less than 50KV at 4mm gap complete all as specifed and directed. NOTE: Transformer oil shall be brought in manufacturer sealed drum at site.
Materials and labour for spray painting of transformer by using spray gun with two coats of Duco paint (Grey) after cleaning thoroughly and preparation of surface of transformer of capacity exceeding 60KVA and upto and including 400 KVA including writing of MES No/SM No complete all as specifed and as directed.
Supply and fix LT Spacer 03 way spiral type made out of PVC material and suitable for to work on 1100 volts fixed between 03 conducters in any position along the LT line for any size of conductor complete all as specified and directed
NARINDER KUMAR SONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .