| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.6 L+₹59,586 (2.98%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹20.6 L+₹61,656 (3.08%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹22.9 L+₹2.9 L (14.5%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
12 Jan 2022, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
CLEANING AND REPAIRS TO SEWAGE LINES, MANHOLES, SEPTIC TANKS AND FILTER BEDS / SOAK WELL ETC AT ORC, BOLTON ROAD AND CAW UNDER GE (AF) HAKIMPET
2021_MES_494830_1
8359/E8
Open Tender
Civil Works
Item Rate
330 days
BEGUMPET AND CAW
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) HAKIMPET
₹48,000
Yes
12 Feb 2022
15 Dec 2021
14 Jan 2022
15 Dec 2021
12 Jan 2022
29 Dec 2021
Amount
Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in soft/ loose soil.
Returning, filling in with approved soil obtained from excavation including spreading levelling, watering and well ramming in layers n.exc. 25cm thick.
Removing the excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Demolition of cement concrete of any description and in any position ( un reinforced)
Demolition of Brick or Stone/boulder masonry built in cement mortar incl all quions, arches, pillars etc.
M&L for Brick work with sub class 'B' old size bricks straight or curved on plan exc 6M mean radius built in CM 1:6 as in manhole, septic tank , filter bed.
M&L for PCC (1:2:4) type B-1 using (20mm graded stone aggregate) for benching coping etc incl necessary form work.
M&L for rendering 15mm thick on fair faces of brick works in cm 1:4 finished even and smooth without using extra cement including water proofing treatment complete all as specified .
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for.
M&L for Precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate ) for manhole cover , septic tank covers slabs etc including necessary from work and set in CM (1:4) .Note :- reinforcement will measured and paid seperately.
S&F MS TMT bars 10 mm dia and over cut to length bent to shape required including cranking , bending hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all specified and as directed.
Demolition and breaking up drain pipes(salt glazed ware, AC or reinforced concrete) set in cement motar including concrete beddeing and haunching complete all as specified and directed 100mm internal dia pipe.
All as per item No.12 above but 150 mm internal dia pipe.
All as per item No.12 above but 200 mm internal dia pipe.
M&L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 for 100mm dia pipe.
All as per item No. 15 above but 150 mm dia drain pipe.
All as per item No. 15 above but 200 mm dia drain pipe.
M&L for SWG drain pipe grade `A` of 100mm internal dia laid in trenches and jointed in cement mortar 1:1 all as specified.
M&L for 150 mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars all as specifed and directed by Engr-in-charge.
All as per item No. 19 above but 200mm dia.
Cleaning of existing sewage line of any size by rodding to clear blockages and removing the silt/sludge/any foreign material and disposing the same outside the MOD land,complete all as specified and directed.Note:- Length of sewage line cleaned by running rod physically to be measured and paid irrespective of length of sewerage stagnated.
Removal of sludge by extracting in water liquid sludge in foul position from septic tank of any size depth or width by mechanically with pump and filling in the covered tank mounted truck and dispose of the same at out of MD land complete all as specified.
Cleaning and de-sludging of existing septic tanks manholes including taking out sludge in any form alongwith all other foreign materials by mechnical equipment or manually or by way of any other suitable means including removal of sludge and other foreign materials out side the MD land by any means complete(working in foul condition) all as specified and directed.
Cleaning of shurbs/bushes/plants all round the septic tank, filter bed, manholes and along the sewage line etc all as directed by the Engr-in-Charge.
cleaning of water closet any type with pupping including removal of sludge/silt complete and depositing the same outside MD land all as directed by EIC.
Cleaning of PVC/cast iron floor trap/nahani trap, gully trap including removal of sludge/silt complete and disposing the same outside MD land all as directed.
Cleaning of manholes of size (minimum 0.45 Sqm and maximum 1.10 Sqm in area) of any depth, cleaning and removal of sludge/silt complete and disposing the same outside MD land including opening and refixing of manhole covers all as specified.
S&F 110 mm dia PVC (SWR) bends of any radius fixed in repairs
S&F PVC (SWR) bends 75 mm dia in repairs.
S&F 110mm dia PVC vent cowl fixed in repairs in place of AC cowl.
S&F PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed to walls bore of the pipe 110 mm in repairs
S&F PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed to walls bore of the pipe 75 mm in repairs
S&F PVC (SWR) bends 110 mm dia with access door.
S&F PVC (SWR) junction double,(single T) equal or unequal. 110 mm dia.
S&F PVC (SWR) junction double,(double T) equal or unequal. 110 mm dia with access door.
S&F PVC (SWR) vent cowl 110 mm dia complete all as specified and directed.
S&F 75 mm dia PVR (SWR) floor trap, plain with grating including jointing with slovent cement in repair complete all as specified and directed.
S&F salt glazed stone ware gully trap, square or round of 150X150 square mouthed type "P" complete all as specified and directed.
Supply only integral water proofing compound.
Supply and fix in repairs PTMT Grating, 100mm dia (Minimum weight 25 gms)
Supply and fix in repairs PTMT Grating, 125mm dia (Minimum weight 40 gms)
S&F 32 mm bore waste water drain pipe flexible in length and PVC hose for wash basin
S&F 40 mm bore waste water drain pipe flexible in length and PVC hose for sink
K P R ENTERPRISES
M/S DIVIJA BUILDERS
KOGANTI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .