Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
12 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KAPURTHALA
GE KAPURTHALA
Repair/Replacement/maintenance of Street/Security lights at Mil Stn Kapurthala under GE Kapurthala
2020_MES_371445_1
GE KPT-42/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
KAPURTHALA
As per tender document
8 documents required · 8 mandatory
₹500
Yes
GE KAPURTHALA
₹80,000
Yes
14 Sept 2020
24 Aug 2020
14 Sept 2020
24 Aug 2020
12 Sept 2020
31 Aug 2020
60 days
Amount
Attending of day to day street/security/Gate light/Post top lantern/High mast light fixed at up to 16 mtr height (HPSV,MH,Flourescent tube light, T-5, LED , Flood light fittings etc. of any make) complaints received through telephone or in person and rectification of defects installed on street light poles 9/11 mtr height,steel tubular/swan neck pole, building walls, roof by bringing down the fittings on grond or in position including replacement of lamp, ignitor, flexible wire, reflector etc including cleaning of glass/acrylic cover for clear reflection of light, replacement of old unserviceable street light fittings with new fittings etc as required to make the light fitting functional .Note : (i) Light fitting, ballast, starter, ignitor, diffuser, cable, flexible wire and LED drive if required to be replaced in repair shall be measured and paid separetely under relevant item of this BOQ for supply and fixing in replacement, however, flourscent tube rod 36/40 watt where required to be replaced shall be issued under schedule 'B' but fixinf of same shall be measured separately. (ii) contractor shall be provide/deputed two electrician and two helper to attend and to rectified the defect within 24 hours of receipt of complaints. (iii) Contractor's manpower should daily recieve complaints from complaint cell at 9.00 AM by JE E/M and report after completion of complaints and handover the complaint slip as record of complaints with user signature. (iv) Flourscent tube rod 36/40 watt shall be issued under Sch 'B' free for fixing by the department. (v) Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract. (vi) Contractor will deposit new material to Engineer in charge for acceptance and then material will be issued by JE E/M daily based on assesment of complaints. Quantity of material to be issued shall be decided by Engineer in charge based on requirement. Note : Transport & Equipment like as Vehicle, ladder, tools and JCB as required at site for repair/for making light fittings functional up to height 12 mtr shall be provided by the contractor at his own cost and arrangement and cost of the same deemed to be included in unit rate quoted.
All as per item No 01 but for gate light/Post top lantern /pole light fixed on pole upto 12 mtr height .
All as per item No 01 but for 16 mtr height high mast lights.
Taking down old unserviceable any type fitting and Supply and fixing Energy saving 30 watts LED street light fitting with PDC Aluminium body and toughened glass visor fitted in frame, separately driver compartment provided, secondary optical lens for superior light distribution efficiency >95Lm/W, CCT 5700K, IP66, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make : Polycab or equivalent in C&S electric (Model Indus series) or Havells/Crompton
Taking down old unserviceable any type fitting and Supply and fixing Energy saving 45 watts LED street light fitting with PDC Aluminium body and toughened glass visor fitted in frame, separately driver compartment provided, secondary optical lens for superior light distribution efficiency >95Lm/W, CCT 5700K, IP66, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make : Polycab or equivalent in C&S electric (Model Indus series) or Havells/Crompton
Taking down old unserviceable any type fitting and Supply and fixing Energy saving 60 watts LED street light with PDC Aluminium body and toughened glass visor fitted in frame, secondary optical lens for superior light distribution, efficiency >100/W, CCT 5700 K, IP 66 input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make : Polycab or C&S electric or Havells
Taking down old unserviceable any type fitting and Supply and fixing Energy saving LED flood light 30 watts suitable for high mast light with PDC Aluminium body and toughened glass visor fitted in frame, secondary optical lens for superior light distribution, efficiency >100/W, CCT 5700 K, IP 66 input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make : Polycab/C&S/Havells
Taking down old unserviceable any type fitting and Supply and fixing Energy saving LED flood light 60 watts suitable for high mast light with PDC Aluminium body and toughened glass visor fitted in frame, secondary optical lens for superior light distribution, efficiency >100/W, CCT 5700 K, IP 66 input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make : Polycab/C&S/Havells
Taking down old unserviceable any type fitting and Supply and fixing Energy saving LED flood light 80 watts suitable for high mast light with PDC Aluminium body and toughened glass visor fitted in frame, secondary optical lens for superior light distribution, efficiency >100/W, CCT 5700 K, IP 66 input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make : Polycab/C&S/Havells
Taking down old unserviceable any type fitting and Supply and fixing Energy saving LED flood light 150 watts suitable for high mast light with PDC Aluminium body and toughened glass visor fitted in frame, secondary optical lens for superior light distribution, efficiency >100/W, CCT 5700 K, IP 66 input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make : Polycab/C&S/Havells
S&F in replacement open construction ballast suitable for 240 volts 50 Hz 1 x 150 watt HPSV/MH Lamp. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement open construction ballast suitable for 240 volts 50 Hz 1 x 250 watt HPSV/MH Lamp. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement open construction ballast suitable for 240 volts 50 Hz 1 x 70 watt SON/MH Lamp. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement electronic ballast 36/40 watt with wire suitable for 1 x 36 watt FTL sleek Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement electronic ballast 2 x 14 watt with wire suitable for 2 x 14 watt T5 FTL. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement electronic ballast 28 watt with wire suitable for 1 x 28 watt FTL Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F replacement metal halide single ended clear tubular lamps (MH DE) suitable for 150 watt enclosed fixture. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F replacement metal halide single ended clear tubular lamps (MH DE) suitable for 250 watt enclosed fixture. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F replacement high pressure sodium vapour tubular clear lamp (SON-T) suiable for 150 watt Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F replacement high pressure sodium vapour tubular clear lamp (SON-T) suiable for 250 watt Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F replacement high pressure sodium vapour tubular clear lamp (SON-T) suiable for 70 watt Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement T-5 rod 14 watt 6500 K, suitable to operate on 240 volts. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement Ignitors suitable for 70 - 250 W SON & MH Lamps short distance type Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
Taking down old unserviceable MCB and S &F MCB SP, 10 to 63 Amp 240 Volt 20 KA, B-Series, in DB/Junction Box complete all as specified and directed.
Supply and fixing in replacement 1100 volt grade heavy duty cable 3 core 1.50 Sqmm PVC insulated copper stranded conductor passing through in 20 mm PVC pipe of cable size size 1.50 Sqmm for connection pupose of street light fitting from DB to street light fitting complete all as specified and directed by the Engr-in-Charge.Note : Contractor should be quoted the rate including 20 mm PVC pipe and 3 core PVC insulated copper conductor cable including fixing accessories.
Taking down old unserviceable box and Supply and fixing of control box for street/security light made of 3mm thick MS Sheet (CRCA) comprising of MCB 16 Amps -01 No SP, bus bar of 50 Amps rating aluminium for phase and netural on porcelain based insulators with locking arrangement fixed to pole with MS clamp of size 20x3 mm, nuts, bolts and washers complete all as specified and directed.
S&F in replacement aluminium conductor steel reinforced for overhead lines on poles including aluminium binding wire 14 SWG jumpers, lines tapes etc complete all as specified of size weasel and mink. Note : for payment purpose weight of ACSR conductor shall be considered.
S&F in replacement of continuos earth wire 4 mm dia galvanised steel wire including galvanised mild steel binding wire 14 SWG complete all as specified. Note : for payment purpose weight of 4 mm dia galvamised wire only shall be taken and clamps, hooks shall be measured and paid separetley.
M&L for replacement loop type insulator, vitreous porcelain white, brown or green with over all size 65x90 mm with clearance dia of hole 16mm complete all as specified and directed.
Supply and fixing in replacement, shackle type porcelain vitreous white, green or brown insulators for working pressure 1100 volts, 90 mm dia, 75 mm height including galvanised MS straps, washers, insulator bolts, washers & nuts compete all as specified and directed. Make : Mysore/Bengal Potteries/WS Madras
S&F in replacement pin type insulator porcelain white brown or green including one galvanized mild steel spindle two galvanised iron washer and one galvanised iron nuts 100 mm height 65 mm dia for 1100 volts grade.
Supply, fabricate and fixing in replacement cross arms (anytype) supports, bracing, stiffeners, clamps etc fabricated from structural steel section including drilling of holes nuts, bolts, washers etc including painting with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply, erecting intruely vertically position concrete pole 9 Mtr long of size 102 mm x 172 mm at top and 102mmx279 mm at bottom class 10 complete including painting of pole up to 1.5 Mtr high from PCC coping in black & white strip each of 30mm high with two coats of synthetic enamel paint complete all as specified and directed (Excavation/ earthwork/PCC work shall be measured & paid separatelly) including taking out existing unserviceable pole & removing from site.
Material and labour for PCC 1:4:8 type D2 (using 40 mm graded stone aggregates) as in foundation bed and around the pole as mass concrete including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for PCC 1:3:6 type C2 (using 40 mm graded stone aggregates) as in foundation of stays and coping of poles etc complete all as specified and directed.
M&L for replacement of stay assembly comprising of GI stay bow 14 mm dia, 40 cm long ( over all) galvanised stay rod 20 mm dia 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30 cm x 30 cm x 6 mm thick 2 Nos of thimbles, MS clamps made out of 50 mm x 6 mm flat iron complete including stay wire 7/8 SWG complete all as directed including necessary excavation, earth work, PCC and loop insulator all as shown in electrical plate No.1 of SSR-2009 Part-I.(PCC, excavation, loop type insulator,stay clamps,stay wire shall be measured and paid for separately under appropriate items of Sch 'A')
Supply and fixing in replacement stay strand of size 7/4 mm made of galvanised steel wire complete all as specified and directed.
M & L for boring hole under the road/pavement/hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting GI pipe of 100/80 mm not less than one meter below ground level complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable ACSR conductor of any type & size including insulators on LT poles complete all as specified and directed.
Supplying, laying, jointing and testing under ground XLPE/PVC armoured heavy duty electric cable insulated and PVC sheathed LT with stranded aluminium conductor 1100 vols grade cross sectional area 10 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed by Engr-in-Charge.
All As per item No 40 but cross sectional area 16 Sqmm 2 core.
All As per item No 40 but cross sectional area 25 Sqmm 3.5 core.
Supplying, laying, jointing and testing PVC heavy duty electric service cable insulated and PVC sheathed LT with aluminium conductor 1100 vols grade cross sectional area 10 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing and testing PVC heavy duty electric service cable insulated and PVC sheathed LT with aluminium conductor 1100 vols grade cross sectional area 16 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation of poles/ stays/ laying of cables etc and getting out including trimming of sides of trenches complete all as specified and directed.
Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed.
Removing of surplus excavated soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. (Note : 18 cm thickness after punning down shall be measured, recorded & paid.)
Material and labour for brick protection using old size sub class ‘B’ bricks, laid flat, dry adjacent to each other laid length wise perpendicular to the axis of cable complete all as specified and directed.
All as per ser item No 49 here-in-before but laying only (old serviceable bricks obtained from taking out of cable shall be reused).
M&L for preparation of old painted surface of PCC LT poles and applying two coats of synthetic enamel paint in alteranate black and white strips of 30 cm each up to 1.5 mtr height from top of PCC coping and numbering of poles complete all as specified and directed.
Labour only for cutting/pruning of tree branches 1.5 mtr all around the LT overhead lines of span n.exc 70 mtr and around the pole obstruction the overhead line & removing the branches to distance n.exc 50 mtr to be the entire satisfaction of Engineer-in-charge,
Supply & fixing GI pipe light grade 80 mm bore for cable protection fixed to pole/along wall/floor/under road etc complete all as specified and directed. Note : Clamps nuts & bolts etc shall be measured and paid for separately under appropriate items of sch 'A'
Supply and fixing 18/20 watt LED Tube rod suitable for tube light fitting 18/20 watt; Make Polycab/Bajaj/Havells/Surya
Supply and fixing 28 watt Tube rod suitable for tube light fitting 28 watt; Make Polycab/Bajaj/Havells/Surya
Supply and fixing 36/40 watt Tube rod suitable for tube light fitting 36/40 watt; Make Polycab/Bajaj/Havells/Surya
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
Supply and fix in replacement of Time light distribution board analog Time switch 230 volt three phase of 16 Amps rating with contactor fixed inside steel enclosure box and fixed to pole/LT Panel including clamps, nuts, bolts and washers etc complete all as specified and directed.Make Indo-Asian cat part No TL016ABO or equivalent in Legrand/Scheneider
Taking down old unserviceable any type of post lantern fitting and supply and fixing decorative LED post top lantern luminaire with diffuser and painted aluminium deflector with LED 25 watts light weight energy saving LED , CCT 5700 K, IP 65 of Make C & S or equivalent in Polycab/Havells/Surya, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Taking down old unserviceable garden light and supply and fixing LED Bollard 10 watt in inverted pyramid tropod type LED Bollard with soft 360 light, IP 65 protection, resistant to corrosion with better optic for uniform distribution Cat part No LBLS1-10CDL of make - Crompton Greaves or equivalent in Philips/Havells/Surya complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable complete
S & F in replacment MCCB 250 Amp, 4 pole, 35 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Standard CAT Part No ISLCNF 0250 (Frame size SKB-3) or equivalent CAT part of make Havell's/ Siemen's/ Schnieder/Crompton
S & F in replacment MCCB 200 Amp, 4 pole, 35 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Standard CAT Part No ISLCNF 0250 (Frame size SKB-3) or equivalent CAT part of make Havell's/ Siemen's/ Schnieder/Crompton
S & F in replacement MCCB 315 Amp 04 pole 415 volt 50 HZ breaking capacity 35 KA with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Havells CAT Part No IHLCNF0315 (Frame size SKB-4) or equivalent CAT part of make Standard/Siemen's/Schnieder/Crompton
S & F in replacement MCCB 400 Amp 04 pole 415 volt 50 HZ breaking capacity 50 KA with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Havells CAT Part No IHLCNF0315 (Frame size SKB-4) or equivalent CAT part of make Standard/Siemen's/Schnieder/Crompton
Taking down old unserviceable bus bar and supply and fixing double door bus bar 4 way 200 amp horizental type suitable size of legs including PCC work as per directed by Engr-in-charge.Make : Standard/L&T/Crompton
Taking down old unserviceable GI bracket and supply and fixing GI bracket 20 mm bore 1.50 mtr length 'L' shape suitable for fixing of street light fitting on pole complete with 2 Nos clamps, Nuts and bolts of suitable size all as directed by Engr in Charge.
AGGARWAL ENGINEERING CO
DUGGAL CONSTRUCTION CO
J.K & Company
M/S BALWINDER SINGH
Guru Kirpa Trading Company
SUNRISE ENGINEERS AND CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .