Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC ACCEPTED BEING LOWEST | |
| 2 | L2₹39.0 L+₹1.4 L (3.84%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹39.5 L+₹1.9 L (5.10%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹41.8 L+₹4.3 L (11.3%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹43.5 L+₹6.0 L (15.9%)Rejected-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹46.4 L
EMD Value
₹93,000
Closing Date
31 May 2023, 6:00 pmClosed
GARRISON ENGINEER UDHAMPUR
GE SOUTH UDHAMPUR
CA NO GE S U 03 2023 24 SPL REPAIR TO BLDG NO NP-2A CONNECTED COVERED PATHWAY PARKING SHED ADDN ALTN TO BLDG NO CP 02 AT CP COLONY AND PROVN OF PATHWAY PLATFORM ALLIED WORK UNDER GE SOUTH UDHAMPUR
2023_MES_594236_1
GE/S(U)-03/2023-24
Open Tender
Civil Works
Works
240 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹93,000
28 Jul 2023
10 May 2023
1 Jun 2023
10 May 2023
31 May 2023
24 May 2023
10 May 2023 - 17 May 2023
Amount
Excavating in post holes (or similar holes ) each n.exc 0.5 cum in soft /loose soil getting out, returning filling in and ramming around in layers not exceeding 25 cm complete all as specified and as directed.
PCC 1:2:4 Type B2 using 40mm graded aggregate as in foundations, filling and mass concrete all as specified and as directed.
Demolition Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
RCC 1:2:4 using 20mm graded crushed stone aggregates as in Foundations including rafts, footings foundation, beams, plinth beams , bases for columns etc, basement slabs, under reamed piles and mass concrete complete all as specified and as directed.
Reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed.
Flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , sides and soffits (if any) foundation and plinth beams and similar work vertical or to batter finished surfaces of concrete complete all as specified and as directed.
Flat formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
Mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to IS complete all as specified and as directed.
Mild steel TMT bars 5mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to IS complete all as specified and as directed.
18-20 mm thick granite stone slab as in shelves / vertical surfaces /platforms set and jointed in neat cement slurry, pointed in colored cement to match the shade incl rubbing of moulding etc complete all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
Brick work with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified.
Rendering 15mm thick on brick or concrete surfaces of walls in CM (1:4) to receive granite slab complete all as specified and as directed.
Hardcore of broken stone or boulders of gauge not exc 63mm and deposited spread and levelled in layers not exc 15 cm thick watered and rammed to a true surface complete all as specified and as directed.
75 mm thick PCC 1:3:6 type C-2, using 40mm graded crushed stone aggregate as in sub base for receiving floor finishes finished even and fair complete all specified and as directed.
25mm thick PCC 1:2:4 type B-0 using 20mm graded crushed stone aggregate as in sub base for laying floor finishes complete all as specified and directed.
Vitrified tiles (Dura stone heavy duty) of size 300 x 300mm x8-10mm thick as in floors set and jointed in neat cement slurry and pointed in white cement to match the surface 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM 1:6 complete all as specified and as directed.
Double charged vitrified tiles of size n exc 0.36 Sqm as in floors set and jointed in neat cement slurry and pointed in white cement to match the surface 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM 1:6 complete all as specified and as directed.
Glazed Coloured Ceramic tiles (exterior wall cladding tiles in stone series) in vertical surface 300x600x8-10mm thick laid over 10 mm thick screed bed in CM 1:4,set and joint in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
Machine pressed (factory made) precast plain cement concrete 1:2:4 type B-1(20mm graded crushed stone aggregate), kerb stone & the like of size 300mm x 300mm x 100mm thick or of size as approved by GE, with plain fair faces including chamfers, weathering etc, embedding in position/laid in trenches on edges of roads, including excavation in any type of soil, setting in cement mortar (1:4) returning filling and removal of surplus soil/debris to a distance n.exc. 50m from the starting point, complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed.
Countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc complete all as specified and as directed.
S&F rolled mild steel Fe-410w (Gde-E-250) quality 'B' Roof trusses (framed ) , trussed, purlins, crane gantries , rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc complete all as specified and as directed.
Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe .290.Gde-E-165 including for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts and ornamental & intricate design of gate etc complete all as specified and as directed.
Dismantling Asbestos cement (corrugated, semi corrugated, etc.), translulent sheets/PVC sheet in roof coverings complete all as specified and as directed.
Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Pre-Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M & L for applying two coats of synthetic enamel ordinary tint paint including red oxide primer and preparation extra complete on new steel or iron surfaces of any description, over 10cm in width or grith, not otherwise described complete all as specified and as directed.
M&L for rolled section as in main and cross beams , purlins , rafters , posts (Square hollow pipes) where connected to common rafter and running rails,frame work of eves board, tank staging work etc conforming to Fe- 410-w complete all as specified and as directed.
PCC 1:2:4 using B0 (12.5 graded crushed stone aggregate) for coping, corner of roof and similar work complete all as specified and as directed.
Vitrified ceramic tiles (Double charged glossy finished), area of each tile not exc 0.42sqm but n exc 1.00 Sqm, 10mm thick (square or rectangular) of superior quality as in floor surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 15mm thich screed bed in cement mortar in 1:6 complete all as specified and as directed.
Glazed ceramic tiles of size 300x600x7mm thick coloured tiles on vertical surfaces set and jointed in neat cement slurry and pointed in white cement mixed with colour pigments to match the existing surface including10mm thich backing coat in cement mortar 1:4 complete all as specified and as directed.
10-12 mm thick gypsum boards seamless false ceiling including sunk or raised moulding or cop design as approved, moisture resistant, including GI hanging wires & frames with intermediate, perimeter channel ceiling channel, along nuts and bolts connecting plates gypsum boards, dry wall screws soffits cleats, ceiling section, rawel plugs fixtures and screws and applying two coats of emulsion paint over a coat primer on exposed surface complete all as specified and as directed. Note : (a) Design of ceiling board as approved by GE. (b) GI grid/hanging system shall be of the same make as of false ceiling manufacturer
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
M & L for 3mm thick wall care putty on wall surface complete all as specified and as directed.
M&L for preparation of newly steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed.
Material and labour for 8mm thick toughened glass (with etching on glass as approved by GE) partition and similar work with fixing of stainless steel clit/stain less steel clamp and fixing aluminium frame wall and floor complete all as specified and as directed.
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where everrequired) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
Powder coated Aluminium frames for doors, windows, ventilators , wind tie for roof with one or more rebates annd aluminium window and ventilator shuttter frames jointing cleats for fixing and partation wall frame etc complete all as specified and directed thickness of powder coating not less than 50 micron complete all as specified and as directed. Note : Powder coated aluminium coating colour as approved by GE.
Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Supply and fixing factory made uPVC white colour fixed glazed window/ventilator/Partition walls made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately).
Supply and fixing factory made uPVC white colour Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension (Area of window upto 0.75 sqm.) comprising of uPVC multi?chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil etc complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
PCC 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation complete all as specified and as directed.
Brick work with sub class B bricks, straight or curved on plan exc 6 m mean radium built in CM 1:4 complete all as specified and as directed.
Wall cladding tiles n exc 1.0 Sqm stone series on exterior wall surface design and size as approved by Engr in Charge as in vertical surfaces of walls, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
18-20 mm thick granite (of any type) work( table rubbed and polished) in steps, jambs, pillars, window sills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab.
Providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in lintels up to 1.5m clear span, cills,seismic and other similar bands, plinth courses, copings, Bed blocks, and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified and as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and as directed.
Taking down Old/ Unserviceable MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and as directed.
Disconnecting and taking down unserviceable light fittings of any description/capacity complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and as directed. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
All as per srl item No 55 above but for 3 pin 5 Amps socket outlet independent including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 55 but for 3 pin 6 Amps socket outlet on the same board including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per Srl item No 55 but for 3 Pin 15 Amps socket outlet independent with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
S&F modular switch 6 Amps single pole one way 230 volt, with outer strip complete all as specified and as directed.
S&F modular switch 16 Amps single pole one way 230 volts with outer strip complete all as specified and as directed.
S & F modular Bell push flush type 6 amps with outer strip complete all as specified and as directed.
S&F modular socket 3 Pin 6 Amps flush type with outer strip complete all as specified and as directed.
S&F modular socket combined 2-in-1, 6 Pin 6 & 16 Amps flush type with outer strip complete all as specified and as directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block complete all as specified and as directed.
S & F Bell AC, 230 volts single pole 50Hz complete all as specified and as directed.
Supply & fixing sheet metal enclosure Double pole with 2 pin and earth plug and socket 25A 240 Volt complete with one double pole MCB of 20 A "C" Series of breaking capacity 10 KA complete all as specified and as directed.
S&F Sheet metal enclosure double door type for DBs (when MCB to be used) 12 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S & F in replacement MCB Single pole and neutral 240 volt any rating from 40 amps"C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB single pole 240 volt any rating from 10 to 40 amps "C" series, with rupturing capacity 10 KA,inculding providing thimble for out going cable complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead all as specified. Including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 4 Sq mm as earth lead all as specified. Including taking down old sub main wire complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type 4 feet with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED luminaire 2X2R 36 watt, 220 V AC recess mounted downlighter type with high efficiency PC diffuser soft light and symmentrical illumination complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Taking out of existing street light pole and fixing of the dismantled pole at a suitable place complete all as specified and as directed. Note :- (a) Necessary PCC and connected items are included in the quoted rates. (b) Excavation, removing and filling are included in the quoted rates.
Supply & Fixing XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 10 Sq mm, 2 core, laid in trenches/ducts/through pipe complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6.3 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized steel earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 5 connected to main control board all as specified and testing on completion. Note: Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc.Note: if earth resistance of earthing is not found (2 to 5 Ω) satisfactory if will be redone by the contractor on his risk and cost.
S&F electronic step type fan regulator 120 watt 230 volts 50 C/S deluxe type complete all as specified and as directed.
Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete all as specified and as directed.
Supply and fixing high speed star rated , ceiling fan 1200mm sweep 230 volt AC single phase with all fixing accessories including providing the suitable size of fan hook in the ceiling as per site requirement complete with all suitable electrical point wiring connection complete all as specified and as directed.
Material and labour for Fixing & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 25 Sqmm x 3.5 core size all as specified including taking down old cable.Note : Earth work and other connected work shall be measured & paid sperately complete all as specified and as directed.
Material & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 4 Sqmm x 2 core size all as specified including taking down old cable. Note : Earth work and other connected work shall be measured & paid sperately.
Excavation in trenches and exceeding 1.5m wide and not exc 1.5m in depth in hard/dense soil and getting out complete all as specified and as directed.
Returing, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating complete all as specified and as directed. Note : for payment purpose punned thickness shall be measured
Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and as directed.
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and as directed.
khajuria builders
BHAGWATI TRADERS
vijay constrction co
SINGH CONST CO
VISHWANATH AND SONS
M/s LAL DAYAL CONSTRUCTION CO
M/S SATINDER PAL & CO.
d d builders
PARDEEP SHARMA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .