Loading…
Loading…
Tender Value
₹2.8 Cr
EMD Value
₹5.7 L
Closing Date
10 Jun 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
18 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
With the submission of the certificate/affidavit as mentioned, the practice of verification of tenderer's documents by the Railway dispensed with. Instruction for bidders, in this regards are:
Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification of lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway thereunder.
In case of any wrong information submitted by tenderer, the contract shall be terminated, Earnest Money Deposit (EMD),Performance Guarantee (PG) and Security Deposit (SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 5 (five) years.
With such a system of self-certification of credentials, tender finalization should also be speeded up. The Tenderer(s) shall keep the offer open for a minimum period of 60 days (in case of two packet system of tendering 90days) from the date of closing of the Tender.
149 conditions · 3 needing a document upload
Any payment required for E-Tendering is accepted through Net Banking or Payment Gateway only.
Credentials in support of fulfillment of eligibility criteria ( Without these documents the offer is liable to be rejected) as per details stipulated in Tender documents. Each and every pages of the supporting documents should be signed with proper seal and date.
Details of technical personnel with qualification and experience employed by the firm.
Details of special equipments , tools and plants, machinery etc available with the firm for execution of contract works.
If working through contract labour , the contractor must resgister with Labour Commissioner and necessary license to be submitted with tender or to be produced before signing of contract agreement.
Partnership deed, if any, constitution of the firm and copies of power of attorney and other connected legal documents to be submitted.
Submission of requisite information for Financial Eligibility criteria as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
All required documents duly attested as per Para 14.0 of IRGCC must be submitted.
Undertaking of OEM/authorized representative for the work of "Augmentation of existing amenities to facilitate Re- Development work at passenger interface area of Raipur Station" that AMC of the entire system (as a whole) shall be undertaken up to codal life of the entire system as per railways requirement after completion of warranty period of THREE years. OEM undertaking duly signed by competent authority of OEM should be submitted giving reference to this tender along with the offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Execution of Signaling & Telecommunication work in connection with: (1) Construction of new 10 rooms (20 bedded) Running Room at Bhatapara in Raipur Division, (2) Construction of new 15 rooms (30 bedded) Running Room at Dallirajhara in Raipur Division, (3) Construction of new combined crew lobby at Dallirajhara, (4) Provision of deficiencies of MEA at KMI, MDH & SLH, (5) Rehabilitation, augmentation & strengthening of power supply arrangement of BMY settlement by availing 33KV power supply at Charoda and improvement of maintenance activity by relocation of substations, (6) Provision of one no. new SSP at MXA over Raipur Division, (7) Setting up of mechanized laundry of capacity of 02 ton per day at coaching depot Durg (8) Construction of 4 unit Type-IV Quarters for Sr.Supervisors at WRS Colony Raipur, (9) Construction of 4 unit Type-V Spl. Quarters for Officer's at WRS Colony Raipur, (10) Augmentation of existing amenities to facilitate Re-Development work at passenger interface area of Raipur Station (11) Augmentation/Upgradation of facilities in new as well as existing running rooms and lobbies for technical advancement of knowledge of crew for enhancement of safety in train operation in Raipur Division, (12) Augmentation of facilities in Diesel Loco Shed, Raipur for homing of electric locomotives.
SNT-R-2026-09
SNT-R-2026-09
Open
Works - General
12 Months
Raipur, Chhattisgarh
₹0
₹5.7 L
10 Jun 2026
12 May 2026
27 May 2026
228 items across 2 schedules · ₹2,84,24,702.62 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Excavation of trench Depth 1.0 Mtr. & width 0.3 Mtr and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil in all soils including soft rocky area. | Kilometre | 4.70 | 76,590 | 3,59,973 |
| 2 | Excavation of trench in all kinds of soils including softrockyarea and clearing of roots of trees, bushes, rocks,ballastetc., to a depth of 1 Mtr. & width 0.3M for track/puccaroad/Platform crossing/ level crossing and any other placeasadvised by the Engineer-incharge includingsupply,transportation and laying of RCC pipe with collars(forjointing pipe) 150mm nominal dia to Spec.No:IS- 458intrench and drawing of Signalling/ Power/ Quadcablesthrough pipe including back filling and ramming aftercablelaying as specified in Technical Circular No.2 of1988issued by CSTE/S.E.Rly. This includes repairingandplastering of platform/pucca road after cable laying.RCCpipe shall be inspected by the Rep.of Sr. DSTE /Rbeforelaying. NOTE:-Power cable,signalling cable, Quadcable asmentioned above,where required shall be laid in thesame trench as signalling cable but in a separate pipe. | Metre | 324.00 | 1,008.8 | 3,26,851.2 |
| 3 | Laying and Fixing of galvanised iron pipe (GI Pipe) withthreadedcollars (for jointing pipe) of 80 mm nominal diaSpec.No.IS- 1239medium grade, on bridges, culverts, drainsincluding supply andtransportation of GI pipes and all othermaterials required forfixing the pipe to Drg.No.Con/SK/T/2and drawing ofSignal/Power/Quad cables inside the pipewith masonary worksover the entire length of the bridge andat entry and exit of theculvert and curing for 72 hrs, drillingof holes on the pipe at 10 cmapart to be clamped 2 Mtrsapart on culvert, for the Signalling,quad, power cable. | Metre | 250.00 | 761 | 1,90,250 |
| 4 | Excavation of trench and clearing of roots of trees, bushes,ballastand reconditioning etc., including bailing out waterand disposal ofextra soil in Hard rocky area includingconcreting. Chase cuttingand smoothening of inside surfaceof sizes 0.08 m deep and 0.17m width at platform andcemented floor area. | Metre | 720.00 | 115 | 82,800 |
| 5 | Excavation of trenches including clearing of roots oftreesetc. in hard rocky soil by chiseling up to a depth of0.5m to0.8 Mtr. At the bottom, supply and placing half roundRCCpipe on sieved soil of 30 mm over cable andconcretingthroughout the lenght upto a layerof 75 mmapproximately(1:2:4) , as advised by the site engineer &Guide lines onSignalling cable Laying issued by SignalDirectorateResearch,Design & Standards organisationMinistry ofRailways Manak Nagar Lucknow- 226011,Version- 1.0,Effective from dt 31.10.2011 . Thendigging and backfillingthe trench by digging and carryingearth from a lead ofmaximum 30Mtrs and then ramming thesoil after cablelaying. This includes supply of half round RCCpipe. | Metre | 1850.00 | 274.32 | 5,07,492 |
| 6 | Excavation of trench and clearing of roots of trees, bushes,ballastand reconditioning etc., including bailing out waterand disposal ofextra soil. Track crossing, Road Crossing bypushing method(HDD method) at culverts/ track / puccaroad crossing at a depthnot less than 1 meter with referenceto bottom of rail/road surfaceincluding supply of GI pipe with76 mm dia, Spec. No. - 1239medium grade (for the length ofpushing more than 05 meters). | Metre | 180.00 | 2,246 | 4,04,280 |
| 7 | Fixing of frame, surface box and white cover plates for Two modules. This also includes fixing of RJ-11 Telephone sockets with level holder Jack type, RJ-45 LAN sockets Jack Type (Tool less) and blanking plates for one modules. Make: Legrand or Similar. | Numbers | 23.00 | 142.99 | 3,288.77 |
| 8 | Laying of Signalling Cable/Power/Quad cable / PIJF cableinthe excavated trench toDrg.No:CON/SK/T/5.Transportation,supply of 'U' clampsand anchoring of cable at every 10 Mtrswith 'U' clamp toDrg.No:CSTE/C/Cable/81 including backfilling withexcavated earth and ramming of trenches aftercablelaying. Note: The contractor has to conduct detailedsitesurvey of the cable route, prepare a plan to get approvalofthe Railway, putting white lime powder markingbeforeexcavation of earth under supervision ofrailways authorised representative. | Kilometre | 18.70 | 16,740 | 3,13,038 |
| 9 | The excavation of pit, casting of concrete foundationincludingsurrounding earthwork along the foundation,erection, installationand wiring of steel appartus case, fixingof terninals, fuse blocks,signal transformer, currenttransformer, filament switching unit,track battery chargers,adjustable/fixed resistances, choke coils,Fuses, Relays, Etype locks , termination of cables, cableinsertion, wiring todraw 110V AC therefore in the new apparatuscase asrequired, testing, commissioning includingsubsequentalterations (if required), bunching of cables,earthing of cable,armours etc. Painting of the apparatuscase inside and outsideafter clearing the surface thoroughlyand first coating of anti -corrosive paint and subsequent twocoatings of Alluminium paintoutside and Red Oxide insideand lettering. 18 mm Hylum sheetfor location box shelf and12 mm for cable termination in locationbox.Steel appartus case (Large) to Drg.No. CON/SK/T/8 with 4Nos. of foundation bolts 20mm x 460mm to Drg.No. SA- 112 A/M or latest. | Numbers | 6.00 | 17,067 | 1,02,402 |
| 10 | Physical tracing and opening/locating of existing workingcables by precession digging for diversion of cables inconnection with cable clearance for engineering earth workwithout interfering the circuits as per the advice of Railwaysite engineer. | Metre | 460.00 | 241 | 1,10,860 |
| 11 | Transportation & Execution of following kinds of joints on Quad Cable using thermoshrink jointing kit. This also includes excavation of cable joint pit of size 1.2m x 1.2m x 1.0m in all types of soil for jointing of copper cables, back filling and ramming after jointing. (b) straight through joint on Quad cable/10-20-50 pairs PIJF Cable. | Numbers | 21.00 | 1,385 | 29,085 |
| 12 | Installation, testing and commissioning of Permanent andMaintenance Free Earth pits.Installation charges : Earthpit(1 Set) It includes: (1) Civil works related to earth pitdigging, PMF earth pit installation,,backfilling and chamber making, (2) Materials for chamber including Chamber Cover. | Numbers | 13.00 | 5,882 | 76,466 |
| 13 | Installation of Krone Module. The work is to be executed as per the instruction of representative of SrDSTE/R. | Numbers | 10.00 | 3.96 | 39.6 |
| 14 | Cement Concrete of proportion 1:3:6 with graded aggregate of size 25mm. and below. | cum | 14.00 | 2,943 | 41,202 |
| 15 | Installation of DP Box 20 Pair with neat wiring and termination of cable (PIJF/Switch Board etc). The work is to be executed as per the instruction of representative of SrDSTE/R. | Numbers | 10.00 | 36.67 | 366.7 |
| 16 | Track crossing, Road Crossing by pushing method (HDD method) at culverts/ track / pucca road crossing at a depth not less than 1 meterwith reference to bottom of rail/road surface including supply of GI/HDPE pipe. (a) HDPE pipe/DWC pipe(4 inch dia) | Metre | 240.00 | 1,080 | 2,59,200 |
| 17 | Fixing of concrete cable route marker at 30- 40 meter andatdiversion point including supply & transportation ofcableroute marker at site. Detail size & fixing of cableroute marker should be followed as per drawing no.SDO/Cable laying/020. | Numbers | 144.00 | 415 | 59,760 |
| 18 | Installation, Testing & Commissioning of Non- Executive/Executive open standard SIP phone. The work is to be executed as per the instruction of representative of SrDSTE/R. | Numbers | 14.00 | 404 | 5,656 |
| 19 | Transportation, installation of optical fibrejoint closure and splicing of Optical fibre cable(2 x 24 fibres) and testing, Optical fibre cablesplicing shall be done in the presence ofRailway's representative. Only joint closureshall issued by the Railway. All othertools/test equipments required shall bearranged by the Contractor. This also includesexcavation of earth for construction ofmasonary pit of bricks (inside completeplastered), the inner size of pit 1.2m x 1.2m(depth 0.75m) in all types of soils for keepingcable coils at the location of OFC joints, fillingthe pit with sand after jointing of cables, ramming and covering with RCC slab as per Drg. and instructions of site incharge of Railway. | Numbers | 21.00 | 19,019 | 3,99,399 |
| 20 | Transportation, installation of Optical Fibre termination box and splicing of Optic FibreCable (24 fibre) inside the termination box with provision of taking out fibre of OFC asrequired. This includes supply of installation accesories (as required) as detailed intechnical specification and advised by Railway's Engineer-at-site.This also includes End toEnd testing of all fibres of the optical fibre cable terminated between cable hut to cable hut of each station. | Numbers | 25.00 | 21,705 | 5,42,625 |
| 21 | Transportation, loading/unloading of OFC fromthe stores of railway to the work site withcare, pushing/pulling OFC through the HDPEpipes, sealing of the duct by sealling /capsplugs. The cable is to be laid by mechanisedmeans. At inaccessible places wheremechanised laying is not possible, the cable isto be laid manually. This also includes testingof cable drums in the store premises beforetransportation and submissions of resultsthereof. Empty cable drums to be returned bythe contractor. The cable drums with unusedcable at site to be returned by the contractorto the stores depot of Consignee. | Kilometre | 7.70 | 18,672 | 1,43,774.4 |
| 22 | Transportation including loading/unloading of HDPE pipe from the stores of railway to thework site, laying of the same in excavatedtrench/already laid GI/RCC pipes/tubes,jointing, levelling and end sealing the pipes. | Kilometre | 8.70 | 7,762 | 67,529.4 |
| 23 | Splicing/Dropping/Termination of each fiber/pigtail in LIU/IO BOX/TERMINAL JOINTS through fusion splicing for termination of OFC cables. The Fibers terminated shall be tested and test report (Hard copy and Soft copy ) shall be submitted to the Railways site Incharge for records. Each fiber shall be properly marked with necessary ferrules/tags. | Numbers | 376.00 | 137 | 51,512 |
| 24 | Fixing of PVC pipes on wall, bridges,platforms etc complete with U clamps & other necessary fixture,screw etc. This includes supply &fixing of T and other bends flexible PVC pipes -25mm etc as required. | Metre | 2820.00 | 3.79 | 10,687.8 |
| 25 | Laying of OFC/Power cable/CAT6Cable on wall/ roof/ FOB/ platform structure/ underground through (i)HDPE pipe/PVC conduit/GI pipe/PVC Tray /casing caping with proper clamping arrangement of HDPE /PVC Conduit /Cable or (ii) through underground DWC pipe and cutting of masonry wall to the depth of 0.75m at the entry of room as per instruction of Railway site incharge and repairing masonry wall cement plastering after cable laying, All fixing, clamping, patching, jointing etc. material like couplers,connectors, OFC patch chords,Power cable Joint Box, masonry materials etc. are to be supplied by contractor. The work is to be executed as per the instruction of Railway Site Engineer. | Metre 12195.00 | — | 6.48 | 79,023.6 |
| 26 | Installation, Testing & Comissioning of 19" 6U Rack. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost. | Numbers | 7.00 | 71.9 | 503.3 |
| 27 | Installation, cable termination, testing and commissioning of 10/20/50 Pair CT Boxes. | Numbers | 21.00 | 786 | 16,506 |
| 28 | Concealed wiring of cat-6 cable/telephone cable/ OFC cable etc in the PVCpipe/PVC channel by making groove in the wall, fixing the PVC pipe withclamps, nails and plastering and distempering to make it as it was earlieras per instructions of engineerin- charge. This includes laying and fixingof all the PVC pipes as per colour in systematic way as per instruction ofRly. Engg. at site. required for laying of all types of cables for railnet,telephoneconnection etc., All the sundry items for the work has to be supplied by thecontractor. Railways will supply telephone cables/Cat-6 cables and PVCpipe/channels. All the telecom cables will be drawn from the specifiedlocation , approved drawing. The payment would be made as per layout ofgrove made in the wall, irrespective of how many pipe (maximum threepipes) are laid and how many cables drawn through these pipes. | Metre | 910.00 | 63.72 | 57,985.2 |
| 29 | Laying & dressing of 6- core OFC cable. This includes supply of GI wire asper thesite condition. All other sandry items required for dressing of the cable to besupplied by the contractor. The work is to be executed as per theinstruction of railway site engineer. | Metre | 4800.00 | 21.5 | 1,03,200 |
| 30 | Supply and fixing of PVC casing caping 25mm x 25mmsizefor indoor wiring. This includes drawal of wires in thecasingcaping and termination of wire at end point.Thework shouldbe carried out as per the instruction of Railway site Engineer. | Metre | 690.00 | 43 | 29,670 |
| 31 | Installation, fixing, wiring & Commissioning of I/O Box work to be executed as per instruction of Railways representative. | Numbers | 50.00 | 14 | 700 |
| 32 | Transportation, Fixing & commissioning of wall mounting Rack (9U) as per instructions of site in- charge. | Numbers | 33.00 | 887.1 | 29,274.3 |
| 33 | Transportation, installation, testing and commissioning of CCTV setup as per instruction of railway representative. | Job | 3.00 | 8,871 | 26,613 |
| 34 | Installation, Testing & Commissioning of Layer- 2 PoE/Ethernet Switch (minimum 8+2 port manageable) with 8 nos. 10/100/1000 Mbps Ethernet port,PoE and 2 nos. 1000BaseX SM SFP port with optical modules .All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost. | Numbers | 44.00 | 2,451.25 | 1,07,855 |
| 35 | Installation, Testing & Commissioning of Single mode 1G SFP module compatible to Layer 2 switch. | Numbers | 22.00 | 184.07 | 4,049.54 |
| 36 | Cutting the masonary wall to the depth of 0.25m to 0.75m at the entry ofroom placing of flexible HDPE pipe or G.I.Pipe (including suppply) ofsuitable size as per instructions ofRailway site in charge and repairing of masonary wall and cementplastering after the cable is taken inside the flexible HDPE pipe/G.I.Pipe with clamps as per drawing No.RE/S&T/ALD/SK/161/81. | Numbers | 32.00 | 573 | 18,336 |
| 37 | Laying of RCC pipe including supply of required quantity at site with collars(for jointing pipe) 150 mm nominal dia to Spec.No:IS-458 in excavatedtrench and laying of Signalling/ Power cable/PIJF cable/ Quadcables/HDPE pipe through RCC pipe. Power cable shall be laid in the sametrench alongwith signalling/Quad cables but in a separate pipe RCC pipe at track/pucca road/ Platform crossing/ level crossing gate etc. | Metre | 530.00 | 775 | 4,10,750 |
| 38 | Provision of Earthing protection arrangement as per RDSO drawing no. TCA 565(Adv.). All the materials including earth electrodes required for the work to be supplied by the contractor. | Numbers | 16.00 | 8,680 | 1,38,880 |
| 39 | Cutting the chase upto a depth of minimum 500 mm.and smoothening of inside surface in concrete and beds of rocks, cable laying/ placing HDPE pipe & concreting upto the ground level. | Metre | 150.00 | 540 | 81,000 |
| 40 | Shifting of existing location boxes to facilitate earthwork of Engg. This includes filling with sand and plastering inside location boxes. | Numbers | 2.00 | 3,580 | 7,160 |
| 41 | Supply and Fixing of Perforated GI pipes of 50 mm dia for entry of cable on girder bridges, RCC bridges, drains, culverts, rocky places, tunnels/ deep cuttings or at places as advised by the engineer in charge of the work. This includes trenching up to the required depth as decided by the Engineer at site and making holes of 5 mm dia(approx.) at 20 cm intervals on the GI pipe. The pipes are to be fixed on the girder bridge by suitable bridge fixtures at an interval of 1.0 mts. (min) or directives of Railway Engineer. On RCC/masonry bridges or in rocky places, if required the entire length of the pipe is to be concreted up to a height of 100mm above the pipe. GI pipe shall be TATA or Jindal make. | Metre | 100.00 | 635.46 | 63,546 |
| 42 | Installation, Testing & Commissioning of Online UPS with complete set of suitablebatteries quantity 3 KVA with battery backup of 60 minutes. The work is to beexecuted as per the instruction of Railway Engineer. | Numbers | 2.00 | 3,171.57 | 6,343.14 |
| 43 | Installation, Configuration ,Testing & Commissioning of LAN Extender with all accessories as per RDSO specification No.RDSO/SPN/TC/82/2020 Rev.2.0 or latest. | Numbers | 4.00 | 369 | 1,476 |
| 44 | Installation, Testing & Commissioning of rack mountable 12 port Loaded LIU. All theaccessories and fixingmaterials required for this installation are to be supplied by contractor within the same cost | Numbers | 17.00 | 693.75 | 11,793.75 |
| 45 | Termination / splicing of 6- core OFC cable. This includes supply & mounting of the termination box. All other sundry items required for the execution of the work is to be supplied by the contractor. The work is to be executed as per the instruction of railway site engineer. Inspection by representative of Sr.DSTE/R | Numbers | 12.00 | 764.35 | 9,172.2 |
| 46 | Horizontal directional drilling HDD/Bore without damage of surface with the bore shallbe 150 mm dia .This includes the insertion of 2 nos HDPE (outer dia 50mm, inner dia -42mm thickness -4mm)/DWC pipe along with couplings etc. The depth will be minimum 1.20 m or more from ground level as per site requirement below the formation level of the earth.Note:-HDPE/DWC Pipe Supply & OFC pulling/pushing are not covered under this item. | Metre | 1000.00 | 245 | 2,45,000 |
| 47 | Cutting of the platform with tile/granite/ concrete cutting machine or manually to 30 cm depth and 12 cm width approximately (including cutting of tiles neatly if provided) by removing slabs/tiles if any and laying of cables/pipes and filling the trench with river sand and replacing the top surface with smoothing finished shaped slabs after putting a laying of cement mortar to the surrounding level as per instruction of site in charge. The surface have to be made as it was before start of the work duly grinding of surface to make it plane and final satisfaction of representative of engineering department. The debris is to be cleared fromplatform to outside station premises and also outsideRailway boundary. Note:- All the sundry materials required for the installation ,wiring, testing and commissioning of above work will be supplied by contractor. | Metre | 780.00 | 119.73 | 93,389.4 |
| 48 | Installation, Testing & Comissioning of Single mode Single Fibre 10G SFP module compitable to Layer 3 core switch .The work is to be executed as per the instruction of Railway Site Engineer . | Numbers | 14.00 | 74.35 | 1,040.9 |
| 49 | Cost of Design, survey & submission of dr awings for permissions from Authorities (including handmade diagram of the network). (Detailed Specification attached in Annexure-M). | Lumpsum | 1.00 | 23,993.56 | 23,993.56 |
| 50 | Installation, Testing & Commissioning of 4K UHD Bullet Type IP Colour camera along with Mount. All the accessories and fixing materials including mount required for this installation are to be supplied by contractor within the same cost. | Numbers | 15.00 | 2,899.87 | 43,498.05 |
| 51 | Installation, Testing & Comissioning of Digital Keyboard (Joystick).The work is to be executed as per the instruction of Railway Site Engineer . | Numbers | 1.00 | 151.44 | 151.44 |
| 52 | Installation, Testing & Commissioning of Server for Video Management and recording with redundant in 1:1 i.e. 2 nos along with all accessories as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest. NOTE: Unit Numbers stands for set i.e. 1+1. | Numbers | 1.00 | 545 | 545 |
| 53 | Installation, Testing & Commissioning of Server with redundant in1:1 i.e. 2 nos for Video Analytics with required accessories as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest. NOTE: Unit Numbers stands for set i.e. 1+1. | Numbers | 1.00 | 2,180 | 2,180 |
| 54 | Installation, Testing & Comissioning of Panic Switch (IK10 and IP66 rated) with Mushroom Cap Push- Button in Red Color, DPDT contact 2Amps 24 VDC, Stain- less Steel Face Plate with GI Junction Box of suitable size and flasher cum strobe of min. 100dB including all accessories required for installation on platforms at stations.The work is to be executed as per the instruction of Railway Site Engineer . | Numbers | 7.00 | 303.34 | 2,123.38 |
| 55 | Transportation, installation, testing and commissioning of CCTV setup at Raipur Station as per instruction of railway representative. | Job | 1.00 | 22,302 | 22,302 |
| 56 | Installation, testing and commissioning of CDC set as per RDSO Spec RDSO/SPN/ TC/108/2019 Ver 1.0 or latest . | Set | 1.00 | 20,800 | 20,800 |
| 57 | Transportation, installation, Testing, fixing & commissioning of PDC/Central Data Switch as per RDSO Specification No. RDSO/SPN/TC/ 108/2019 Ver.1.0 or latest | Numbers | 2.00 | 4,455.4 | 8,910.8 |
| 58 | System integration, inter connectionwith the existing system with Coachguidance boards / Train indicationboards & others as per the siterequirement. This includes setting of software, programming . All sundry items like patch cord, connector etc are to be supplied by the contractor as per site requirement. The work is to be executed as per the instruction of railway site engineer. | Job | 1.00 | 5,629.6 | 5,629.6 |
| 59 | Transportation, installation, testing & commissioning of Horn Speaker as per instruction of site in-charge. This includes supply of all necessary materials for installation. | Numbers | 23.00 | 307.44 | 7,071.12 |
| 60 | Installation and commissioning of Multi line Train Indication Board cum video display (6 lines) LED type single face with all necessary accessories and video display controller, LED type as per RDSO specification RDSO/SPN/TC/ 108/2019 Ver.1.0 or latest. The work is to be executed as per the instruction ofrailway site engineer. | Numbers | 2.00 | 57,934.8 | 1,15,869.6 |
| 61 | Transportation & Execution of following kinds of joints on Quad Cable using thermoshrink jointing kit. This also includes excavation of cable joint pit of size 1.2m x 1.2m x 1.0m in all types of soil for jointing of copper cables, back filling and ramming after jointing. (a) Derivation/ transformer joints with V.F. Transformers and derivation joint for L.C.Gate & Pump House on Quad/jelly filled Telecom Cable. | Numbers | 2.00 | 1,993 | 3,986 |
| 62 | Excavation of earth pit, transportation, placing and fixing of earth electrode with construction of cement encloser to Drg.No.CON/SK/T/9 and CON/SK/T/9A and drawal of GI wire wrapped on MS strip (35 x 6 mm) from earth electrode to all signalling equipments, including fixing and soldering of lugs at both end of the wire. | Each | 4.00 | 1,941 | 7,764 |
| 63 | Alteration/ Modifications in the existing location boxes, fixing ofequipments, cable insertion, termination, wiring, testing &commissioning, two coat painting, lettering to suit the circuits asper approved wiring diagrams. This includes filling with sand and plastering the same. | Numbers | 4.00 | 2,548 | 10,192 |
| 64 | Location survey of cable route and preparation of tentative and final cable route plan as per approved format in the section including supply of final route plan after the cables are laid and commissioned indicating clearly the exact position of the cable, joints and other critical items with reference to OHE mast & other fixed point, etc. in 12( twelve) Nos. hard bound copies on white bond paper of maximum A-3 size (well documented and bound with plastic covers). | Route Kilo Meter (RKM) | 1.00 | 950 | 950 |
| 65 | Dismantaling of unused/old emergency socket post approximate dimention Height - 1.25 mtr * cross section- 15 cm x15 cm (drg enclosed) and transportation from site to GSD store/Raipur, which includes excavation of soil/concrete to a depth of 15 cm from the surface and back filling and ramming after cutting the post.This is required to avoid projection of remain of post over the ground level.The contractor must ensure, that rail post shall be cut below the normal ground surface area. | Numbers | 2.00 | 892 | 1,784 |
| 66 | Shifting/ re-location, fixing, erection of rail post of size 2.8mtrs and testing of emergency socket as per direction of site engineer of railway. This includes excavation of trenching for shifting the existing 10/20 PIJF cable, clearing of existing Rail post with foundation and re-erection of same rail post. | Numbers | 2.00 | 1,053 | 2,106 |
| 67 | Supply transportation, fixing, wiring, termination of cable, erection of rail post of size 2.8mtrs including foundation of post in cement concreate (1:2:4) as per the direction of the site Engineer incharge of Railway, testing and commissioning of six pin emergency socket box complete cast iron make as per Drg. No. SE/T/50/76. This include transportation of rail posts (provided by the Railway) from Raipur or any place in the section to work site, fixing of 40 mm dia G.I.Pipe and emergency socket box. Cast iron emergency socket box with complete fittings are to be first supplied to the stores of SSE/T/R and then collected from there for execution. Supply of U-bolt for fixing emergency socket, cutting of Rails to the size and welding of G.I.Pipe on the rail post will be done by the Contractor. This work includes painting of rail posts with black and white paints after two times primer coating. Note :- 02 Nos of emergency sockets with complete fittings including Cast iron box to be supplied extra as spare within the same cost. | Numbers | 2.00 | 11,504 | 23,008 |
| 68 | Transportation, installation, configuration, migration and commissioning of High end Server. This includes supply of all required accessories and fittings with software license etc for Commissiong of Server. | Job | 1.00 | 2,24,900 | 2,24,900 |
| 69 | Installation, Testing & Commissioning of 48 port FXS Gateway. The work is to be executed as per the instruction of representative of SrDSTE/R. | Numbers | 1.00 | 6,191.4 | 6,191.4 |
| 70 | Installation, Testing & Commissioning of Video VoIP phone. The work is to be executed as per the instruction of representative of SrDSTE/R. | Numbers | 1.00 | 2,088.29 | 2,088.29 |
| 71 | Shifting of existing cables by providing location boxes and pieces of signalling cables as required in the yard to facilitate the engineering department for earth work for laying new lines. (work will be executed in presence of Railway representative). The cost towards new location foundation shall be given vide item No.10(a/b/c) of SOR SCH- A when the length of trench is less than 150 meters. | Numbers | 1.00 | 30,189 | 30,189 |
| Schedule total | ₹61,98,038.44 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexureA-M.pdf
ATTACHMENT
IRGCCApril-2022.pdf
ATTACHMENT
Annexure-VIAVIB.pdf
ATTACHMENT
Annexure-2LC.pdf
ATTACHMENT
TAN3006Ver3_1dated30_06_2025Earthing.pdf
ATTACHMENT
letterTTPrailwayboard.pdf
ATTACHMENT
GCCACSs.pdf
ATTACHMENT
TelecomCircularsLetters.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .