| 1 | L1₹9.6 LAccepted-AOC 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹9.6 L Quoted ₹10 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹12.0 L+₹2.0 L (19.6%)Rejected-Finance | ₹12.0 L+₹2.0 L (19.6%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹12.6 L+₹2.6 L (26.3%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | ₹12.6 L+₹2.6 L (26.3%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹13.8 L+₹3.8 L (37.7%)Rejected-Finance | ₹13.8 L+₹3.8 L (37.7%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹15.6 L+₹5.6 L (55.6%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | ₹15.6 L+₹5.6 L (55.6%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
7 May 2022, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
REPAIR/REPLACEMENT OF INTERNAL WIRING INCLUDING REPLACEMENT OF FITTING FIXTURE AND MISC E/M WORKS AT AF STN BARNALA UNDER GE (AF) HALWARA
2022_MES_517004_1
GE/HAL-14/2022-23
Open Tender
Civil Works
Item Rate
365 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS E CATEGORY b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹50,000
Yes
10 Jun 2022
7 Apr 2022
9 May 2022
7 Apr 2022
7 May 2022
22 Apr 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power, bell point ) complete, including fixture and fittings such as switches, bell push,ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit and making good disturbed surfaces of walls, floors, etc
M&L for one light point controlled by one 6 Amp one way switch, Point wiring concealed conduit type with 1.5 sqmm PVC for insulated unsheathed and multi stranded copper conductor PVC conduit 20 mm bore having 2 mm wall thickness with all conduit accessories for one light /fan/buzzer/soket outlet point controlled by one switch including continuous 1.5 sqmm copper conductor, stranded (green colour as earth ,red as phase and black as neutral), PVC insulated unsheathed earth wire to common earth and connected to earth dolly to be terminated in and including suitable size module boxes alongwith modular cover plate for housing of module switches/sockets etc . . Note : Unit rates quoted by contractor shall be deemed to included for cutting chases in walls and making good in cement morter (1:3) and finishing the surface to match with exisiting surface with distemper and wall putty complete all as specified and directed.
All as per Sl item No 2 above but for one celing/Exhaust fan/bell point controlled by one 5 Amps one-way switch and regulator.
All as per Sl item No 2 above but for one 5 pin 6 Amps switch socket outlet point on independent board
All as per Sl item No 2 above but for one 5 pin 6 Amps switch socket outlet point on same board
All as per item No. 2 here in before but with 2.50 Sqmm copper conductor wiring with 2.50 Sqmm copper conductor as earth continuity for 15/16 Amps socket out let on independent board.
M & L for one light point controlled by one 6 Amp one way switch, point wiring complete with 1.5 Sqmm PVC insulated and unsheathed FRLS cable single core multi stranded copper conductor, 1100 volts grade drawn through and including PVC casing / capping including copper earth continuity wire of PVC insulated of size 1.50 Sqmm and connected to common earth dolly with all accessories (gang box for switch socket, ceiling rose box,holder box,tee ,bend etc ) complete as specified and directed.
All as per Sl item No 7 above but one celing/Exhaust fan/bell point controlled by one 5 Amps one-way switch and regulator.
All as per Sl item No 7 above but one 5 pin 6 Amps switch socket outlet point on independent board
All as per Sl item No 7 above but one 5 pin 6 Amps switch socket outlet point on same board
All as per item No. 7 here in before but with 2.50 Sqmm copper conductor wiring with 2.50 Sqmm copper conductor as earth continuity for 15/16 Amps socket out let on independent board.
S&F in replacment of module switch 1 way 6 A, 1 module complete all as specified & directed.
S&F in replacment of module switch bell push type 1 way 6 A, 1 module complete all as specified & directed.
S&F in replacment of module switch 1 way 16 A, 1 module complete all as specified & directed.
S&F in replacment of modular socket, 6 Amps, 2/3 pin combined 2 module complete all as specified
S&F in replacment of modular socket, 6/16 Amps, 2/3 pin combined 2 module complete all as specified
S&F in replacment of modular step fan regulator 2 module complete all as specified
S&F in replacement switch socket combination outlet , 2 in 1, multipurpose 3 pin, 5/15 Amps, flush type having four holes for fixing complete all as specified and directed.
S&F in replacement switch piano flush button SP one way 5 Amp
S&F in replacement switch socket out let, 3 pin 5 Amp ,flush type, multipurpose all as specfied and directed
S & F in replacement socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S&F in replacement bell Ding Dong, AC, 230 volts, single pole controlled by one bell push all as specified
S&F in replacement bell push, AC, 230 volts, single pole all as specified
S&F in replacement electronic resistance step speed regulator, suitable for 1200 mm sweep ceiling fan up to 300 watt all as specified.
S&F in replacement lamp holder PVC/ Polycarbonate type with cord grip cap, insulated body, threaded dome pattern, suitable for pendant fittings.
Supply and fixing in replacment of Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body
Supply and fix in replacment of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up to ceiling rose with three core 1.5 Sqmm flexible copper conductor complete all as specified and directed.
S & F in replacement of existing light fitting with LED batten integrated channel 18 watt having input voltage AC90-300V, 50 Hz , 6500K ,polycarbonate housing with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make:-Havells Model No.LUMILINEBS18WLED865SPCWH or equivalent in polycab and C&S)
S & F in replacement of existing light fitting with LED batten integrated channel 20 watt having input voltage AC90-300V, 50 Hz , 6500K ,polycarbonate housing with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make:-Havells Model No.LUMILINEBS20WLED865SPCWH or equivalent in polycab and C&S)
S & F in replacment of existing light fitting with LED midbay 70 Watt luminairs with IP65 protected, energy saving, environment friendly & robust, PDC housing suitable for ceiling (Surface/Suspended) mount & in Wide beam optics having System efficacy 125 lm/W to 130 lm/W suitable for work shop including all accessories and lamps and making electric connections complete with nut bolt and clamps all as specified and directed by Engineer - in - Charge.( Make:- Havells ordering code ILIOSBAYPLUSHBP70WLED857SP90DTOPC or equivalent in polycab and C&S )
S & F in replacment of existing light fitting with Water tight bulk head LED 10 Watt light fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed by Engineer - in - Charge..
S & F in replacment of existing light fitting with LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer - in - Charge.
S & F in repairs sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 2 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / indoasian)
S & F in repairs sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / indoasian)
S & F in repairs sheet metal enclosure for double door BD made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / indoasian)
S & F in repairs sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted VTP & N 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCCB and isolators etc including fixing in Wall with cement mortar complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Standard / Indo Asian )
S&F MCCB TPN 63 Amps with breaking capcity 25kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / Indo Asian)
S & F in repairs MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 30 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / indoasian)
S & F in repairs MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 30 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / indoasian))
S&F security light fitting LED TYPE 35 watt optic lenses with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 32 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge (Make of light fitting - Havells /Surya /Polycab)
S & F in replacment of existing light fitting with LED Decorative, wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LED lamp B22 base.watt 220 V AC and 9 watt LED lamp 3000K including connecting up with ceiling rose complete all as specified and directed by Engineer - in - Charge.
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in concealed PVC conduict dia 20mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. (Note : PVC cable and PVC conduit shall be ISI marked) ( Make of cable - Kalinga/Havells/finolex)
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn existing PVC conduict including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. ( Make of cable - Kalinga/Havells/finolex)
M& L in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core Cable flat of circular of size 6 Sqmm 2 Core including taking down existing old service connection, complete all as specified and directed.
M & L in replacment of existing AC Box having Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 A complete all as specified and directed.
S & F rigid non-metallic PVC conduit for segregarion of existing hanging wires ,medium grade 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, all as specified and directed.
Supply and fix in replacment of Existing bulb to LED Bulb 10 watt ,retrofit pin type,B22 Base cap,lumen output 950lm,6500K colour temp, complete all as specified and directed.
Supply and fix in replacment of Existing bulb to LED Bulb 7 watt ,retrofit pin type,B22 Base cap,lumen output 700lm,6500K colour temp, complete all as specified and directed.
Supply and fix in replacment of Existing bulb to LED Bulb 5 watt ,retrofit pin type,B22 Base cap,lumen output 500lm,6500K colour temp, complete all as specified and directed.
TESLA ENGINEERS & BUILDERS
R N Enterprises
DHALIWAL CO.
AGGARWAL & CO
S K BANSAL AND CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .