Loading…
Loading…
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
5 Aug 2026, 1:00 pm
At TSK Division- Provision of new station building at MZS, SPTR, DMC and NLP under ABSS
LV-T-14-TSK-950
LV-T-14-TSK-950
Open
Works - General
14 Months
Darbhanga, Bihar
₹0
₹2.6 L
15 Jul 2026
15 Jul 2026
22 Jul 2026
A-AT TSK Division- Provision of new station building at DMC under ABSS.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 001 wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 002 wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A,ceiling rose,Modular GI metal box with suitable modules for fixing switches & Regulators and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire .
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 003 wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 6 A ,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 004 wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring for AC point from main/sub-main board t o the points by 6 mm sq single core multi-strand 005 FRLS copper cable through heavy duty PVC conduit pipe including MCB Protected Power Unit 16 A ,modular type having Socket, push Starter and 1.0 mm.sq. unsheathed copper cable in green colour for earth continuity wire.
Supply, drawing and connection of single core 1.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 4.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 6.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, laying, fixing, testing and commissioning of medium class rigid PVC conduit of specified size, conforming to IS 9537 (Part-3) or latest, complete with all accessories such as 011 bends, couplers, junction boxes, inspection boxes, tees, elbows, saddles, spacer bars, bushes and draw wire, laid either on surface or recessed in walls, ceilings or slabs, including painting of surface- mounted conduit to match the surroundings or cutting chases, fixing the conduit and making good the wall/plaster in case of recessed installation, complete in all respects as directed by the Engineer- in-Charge.
Erection of earth by 50 mm dia 3 Mtrs. long (Medium Gauge) GI pipe , 8 SWG GI 012 wire,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with CI plate having locking arrangement and watering pipe as per drg. Nos.PCEE/ELG/DRG/2024/1 dated 30.09.2024
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip 013 earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply, fitting, fixing, testing and commissioning of 6 way Double Door SPN MCB DB 014 with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB 32 A SP 'C' Series, 10KABC= 2 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, fitting, fixing, testing and commissioning of 8 way Double Door SPN MCB DB 015 with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB 32 A SP 'C' Series, 10KABC= 4 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, fitting, fixing, testing and commissioning of 4 way Double Door TPN MCB DB( 016 4+12) with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i) MCB 40 A TPN 'C' Series, 10KABC= 1 Nos (ii)MCB 32 A DP 'C' Series, 10KABC= 4 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 16 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 017 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 25 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 018 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 50 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 019 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 70 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 020 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 120 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 021 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, fitting , fixing of Batten Intergated type LED fitting 40W, 4 Ft, ultra slim co- extruded polycarbonate channel with integrated electronic driver should be as per IEC: 022 62384/IS:16104( SMPS based constant current output, THD<20%), IP20 protection, color temperature=6500K, rated input voltage=230V AC, 50 Hz, power factor=0.9, view angle>=120°, lumens output not less than 100 lm/Watt, operating voltage range: 140-270 V AC. LED Should be as per LM-80/IS:16105. Fixture Size:(LXWxH=1156x25x35 mm +/-1) .
Supply, fitting, fixing of recess mounted 18 Watt LED Panel light Square( Ceiling Cut Out 175x175 mm) pressure die-cast aluminium luminaire in powder coated white finish in square 023 profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver. Lumen Output: 1260 Lumen, Color Temperature: 6500K, Voltage Widthstanding range: 140 V to 270 V AC, 50 Hz. Height of fixutre: 23 +/- 1 mm.LED Should be as per LM-80/IS:16105. LED Chip specification
Supply, installation, testing and commissioning of 1 x 10 W, 2 ft linear surface- mounted LED mirror light fixture, suitable for mirror and vanity lighting applications, comprising powder-coated aluminium housing with opal polycarbonate diffuser, high-efficiency LED module, integral constant current electronic driver, system efficacy not less than 100 lm/W, CRI 80, CCT 4000 K/5700 K (as approved), operating voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, IP20 protection, minimum L70 life of 50,000 burning hours, complete with mounting accessories, testing and commissioning, conforming to relevant IS/IEC standards, complete in all respects.
Supply, installation testing and commissioning of Energy Efficient Ceiling Fan 1200 025 mm sweep BLDC motor, BEE 5 star rated ceiling fan With regulator enable motor with power of 26 watt with 10% tolerance , motor insulation B type 220-240V 50Hz single phase with Speed minimum 350 rpm minimum air delivery 225CMM complete set of 3 no's. blade , down rods, 2 nos canopies , shackle kit & all remaining accessories including nut bolts Washers complete as required .
Supply, installation, testing and commissioning of 300 mm sweep Exhaust Fan, plastic louver type, suitable for wall/window mounting, complete with high-efficiency single-phase 026 induction motor, aerodynamically designed blades, automatic gravity louvers, bird guard, operating voltage 230 V AC, 50 Hz, low-noise operation, complete with mounting frame, fasteners, wiring up to terminal, all accessories, testing and commissioning, conforming to relevant IS/IEC standards, complete in all respects.
Supply installation of Inverter Split Air Conditioner, 1.5 Ton, BEE 5 Star Rated of wall- mounted split type with inverter compressor technology, suitable for efficient cooling with low power consumption. The AC shall have a rated cooling capacity of 1.5 Ton (approximately 5.0-5.2 kW) and shall operate on 230 V AC, 50 Hz single phase power supply. The unit shall be BEE 5 Star rated as per latest BEE norms, with ISEER value not less than 4.6 (or as per current 5-Star classification), ensuring high energy efficiency. It shall be equipped with a high-efficiency rotary inverter 027 compressor, using eco-friendly refrigerant (R-32 or equivalent), suitable for tropical climatic conditions. The indoor unit shall have a low-noise blower, uniform air distribution, washable air filters, and precise temperature control, while the outdoor unit shall be robust, weather-resistant and supplied with a heavy-duty galvanized steel / powder-coated mounting bracket for fixing the outdoor unit. The scope shall include supply and installation of required low-pressure (suction) and high-pressure (liquid) copper connecting pipes of suitable diameter and thickness, properly insulated, of required length as per site installation conditions, complete with flare nuts and fittings, ensuring leak-proof operation.The AC shall include standard safety and protection features such as overload protection, voltage fluctuation protection, and auto-restart
Supply, Installation of Pure Sine wave Inverter 5500 VA Real Power 3800 Watt, 028 Supports 4 Nos 12 V Battery, MCB protection for Input mains, Bypass switch for supplying output directly from grid in case of Home inverter fault,Protection against short-circuit, battery over-charge, deep-discharge etc.
Supply, installation, testing and commissioning of Tall Tubular Lead Acid Battery, 12 V, 150 Ah, conforming to IS 13369 / IS 1651 or latest applicable BIS standards, comprising 4 Nos. of 029 batteries, having high-pressure die-cast lead alloy grids with tubular positive plates for long service life and deep discharge capability, robust high-impact polypropylene (PP) container, low- maintenance design, suitable for inverter/UPS/DC power supply applications, complete with interconnecting links, terminal covers, mounting accessories and all materials required for proper installation, testing and commissioning, complete in all respects.
Supply, installation, testing and commissioning of 2 kVA Online UPS, true double conversion type, 72 V DC, suitable for operation supports an external battery bank 6 Nos. of 12 V , pure sine wave output, DSP/microprocessor controlled, input voltage range 160-300 V AC, output 030 voltage 230 V AC ±1%, input frequency 50 Hz ±10%, output frequency 50 Hz ±0.1%, efficiency 90% in online mode, input power factor 0.99, with overload, short-circuit, over-voltage, under-voltage and battery protection, LCD/LED display with audible alarms, RS-232/USB communication interface, manual/static bypass arrangement, complete with all mounting accessories, input/output terminals, testing and commissioning. The UPS shall conform to relevant IS/IEC standards and shall be supplied with a minimum warranty of 24 months, complete in all respects.
Supply, installation, testing and commissioning of 12 V, 100 Ah Sealed Maintenance Free (SMF) Valve Regulated Lead Acid (VRLA) Battery, suitable for UPS/inverter/DC power supply 031 applications, maintenance-free, spill-proof, rechargeable type, complete with interconnecting leads, terminal covers, mounting hardware and all accessories required for proper installation. The battery shall conform to relevant IS/IEC standards, be provided with a minimum warranty of 36 months, and include testing, commissioning and satisfactory operation, complete in all respects.
"Supply, fitting, fixing, testing and commissioning of 4-Way SMDB, 250 A (Double Door Type), suitable for indoor installation, complete with 4-pole MCCB incomer and 4-pole MCCB outgoing feeders, fabricated from CRCA sheet steel, powder-coated, and conforming to relevant IS/IEC standards. The SMDB shall consist of the following components: (i) Main SMDB Enclosure (Double Door Type) 4-way enclosure suitable for 200 A, 4-pole MCCB as incomer and 4-pole MCCBs as outgoing feeders, complete with mounting arrangements, removable gland plates, earthing terminals and adequate cable entry provisions. (ii) SMDB Bottom Cable Unit (Double Door) - 1 No. 032 (iii) SMDB Cable Alley Unit, 250 A (Double Door Type) - 2 Nos. (iv) Metering Unit (for Double Door SMDB only) Complete with Ammeter, Voltmeter with selector switch and Phase Indicator Lamps (3 Nos.), including internal wiring and accessories. (v) SMDB Corner Units for Double Door - 4 Nos. (vi) MCCB Incomer 200 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release, complete with mounting, interconnections and protection accessories - 1 No. (vii) MCCB Outgoing Feeders 125 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 2 Nos. 100 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 1 No. 63 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 2 Nos. The SMDB shall be provided with electrolytic grade copper busbars, adequately rated for the system current and fault level, mounted on suitable insulated supports and colour coded. Internal wiring shall be carried out using PVC insulated copper conductors with proper ferruling. The panel shall be provided with earthing arrangement, labels, danger notices and circuit identification, complete in all respects. Installation shall include alignment, levelling, tightening of all electrical connections, testing of insulation resistance, functional testing and commissioning. The rate shall be inclusive of all materials, labour, tools, transportation, installation, testing, commissioning and all incidental works, complete in all respects, as per the approved specifications and directions of the Engineer-in-Charge."
Supply, fitting, fixing of wall mounted VTPN DB, Horizontal TP MCCB as incomer 4 way 033 double door , IP: 43 Protection, Shrounded Neutral Bar and pan assembly with flexible connecting link., cement spill protector, door earthing with the following:(i) MCCB 100 Amps, TPN ,25KA BC= 1 No.(ii) MCB DP 63 Amps, C series, Icn =10KA BC= 4 Nos. (iii) MCB DP 32 Amps, C series, Icn =10KA BC= 8 Nos
Supply, fitting, fixing of 200 Amps outdoor type cable junction box, angle frame 034 mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 200 Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). The base of the fedder pillar junction box to be provided with CC foundation of propotion 1:1.5:3( cement, sang,Chips) after connection of Ug cables.
Supply, installation, testing and commissioning of 15 W decorative LED Up-Down Wall Luminaire, IP66 protected, suitable for surface wall mounting, incorporating high-efficiency COB LED 035 as light source, pressure die-cast aluminium housing with polyester powder-coated finish, toughened clear glass diffuser/lens, system efficacy not less than 100 lm/W, CRI 80, CCT 3000 K/4000 K/5700 K (as approved), integral constant current electronic driver, input voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, minimum L70 life of 50,000 burning hours, complete with all mounting accessories, testing and commissioning.
Supply, installation, testing and commissioning of 15 W LED Spike Light, compact, lightweight and energy-efficient, IP66 protected, suitable for landscape and garden illumination, incorporating high-efficiency COB LED as light source, pressure die-cast aluminium housing with 036 polyester powder-coated finish, toughened clear glass lens, adjustable mounting bracket with ground spike, system efficacy not less than 100 lm/W, CRI 80, CCT 3000 K/4000 K/5700 K (as approved), integral constant current electronic driver, operating voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, minimum L70 life of 50,000 burning hours, complete with all mounting accessories,testing and commissioning.
Supply, installation, testing and commissioning of 24 W LED Post Top Landscape Luminaire, IP65 protected, warm white, comprising spun aluminium housing with opal diffuser, incorporating 3 x 8 W high-power COB LEDs as light source, complete with integral constant current 037 electronic driver, system efficacy not less than 100 lm/W, CRI 80, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, operating voltage 140-270 V AC, 50 Hz, minimum L70 life of 50,000 burning hours, mounted on 2.0 m high hot-dip galvanized steel tubular pole with base plate and foundation bolts, including excavation, PCC/RCC foundation, grouting, backfilling, cable termination, earthing connection, all mounting hardware, accessories, civil works, testing and commissioning, complete in all respects.
Supply, installation, testing and commissioning of thermoplastic cable junction box, IP66 weatherproof, suitable for outdoor installations, of size 104 mm x 104 mm x 70 mm, with metric knockouts for cable entry, complete with terminal block suitable for termination of 1.5 sq.mm to 2.5 sq.mm copper conductors, weather-resistant gasket, stainless steel fixing screws, wall mounting accessories, glands, hardware and all accessories required for complete installation.
Supply, installation, testing and commissioning of thermoplastic cable junction box, 039 IP66 weatherproof, suitable for outdoor installations, of size 130 mm x 180 mm x 77 mm, with metric knockouts for cable entry, complete with terminal block suitable for termination of 4 sq.mm to 10 sq.mm copper conductors, weather-resistant gasket, stainless steel fixing screws, wall mounting accessories, cable glands, hardware and all accessories required for complete installation.
Supply, installation, testing and commissioning of 50 W Decorative LED Post Top Lantern complete with 5.0 m high decorative hot-dip galvanized GI/MS pole, suitable for outdoor lighting applications, having Victorian aesthetic design with pressure die-cast aluminium housing, graphite grey polyester powder-coated finish, frost clear PMMA diffuser and optical grade clear PMMA optics, complete with high-brightness LED module of 50 W system power, Type-II light 040 distribution, system efficacy not less than 100 lm/W, CRI 70, CCT 5700K ±500K, IP65 protection for optical and control gear compartments, IK07 impact resistance, integral constant current electronic driver, internal surge protection of 5 kV and external surge protection of 10 kV, operating voltage 150-270 V AC, 50 Hz, power factor 0.95, THD 15%, Class-I electrical safety, minimum LED life L70 50,000 burning hours at 25°C, mounted on 5.0 m decorative pole complete with base plate, foundation bolts, excavation, PCC/RCC foundation, grouting, backfilling, cable termination, earthing connection, all mounting hardware, wiring, accessories, testing and commissioning, complete in all respects.
Dismantling of existing electrical pole of any type and height, including disconnecting 041 overhead conductors/cables, dismantling all associated fittings and accessories, lowering the pole safely to ground level, stacking the released materials at the location specified by the Engineer-in- Charge within the railway premises, making the site safe and clearing all debris, complete in all respects.
B-AT TSK Division- Provision of new station building at NLP under ABSS.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 001 wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 002 wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A,ceiling rose,Modular GI metal box with suitable modules for fixing switches & Regulators and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire .
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 003 wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 6 A ,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 004 wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 005 wiring for AC point from main/sub-main board t o the points by 6 mm sq single core multi-strand FRLS copper cable through heavy duty PVC conduit pipe including MCB Protected Power Unit 16 A ,modular type having Socket, push Starter and 1.0 mm.sq. unsheathed copper cable in green colour for earth continuity wire.
Supply, drawing and connection of single core 1.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 4.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 6.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, laying, fixing, testing and commissioning of medium class rigid PVC conduit of specified size, conforming to IS 9537 (Part-3) or latest, complete with all accessories such as 011 bends, couplers, junction boxes, inspection boxes, tees, elbows, saddles, spacer bars, bushes and draw wire, laid either on surface or recessed in walls, ceilings or slabs, including painting of surface- mounted conduit to match the surroundings or cutting chases, fixing the conduit and making good the wall/plaster in case of recessed installation, complete in all respects as directed by the Engineer- in-Charge.
Erection of earth by 50 mm dia 3 Mtrs. long (Medium Gauge) GI pipe , 8 SWG GI 012 wire,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with CI plate having locking arrangement and watering pipe as per drg. Nos.PCEE/ELG/DRG/2024/1 dated 30.09.2024
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip 013 earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply, fitting, fixing, testing and commissioning of 6 way Double Door SPN MCB DB 014 with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB 32 A SP 'C' Series, 10KABC= 2 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, fitting, fixing, testing and commissioning of 8 way Double Door SPN MCB DB 015 with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB 32 A SP 'C' Series, 10KABC= 4 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, fitting, fixing, testing and commissioning of 4 way Double Door TPN MCB DB( 016 4+12) with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i) MCB 40 A TPN 'C' Series, 10KABC= 1 Nos (ii)MCB 32 A DP 'C' Series, 10KABC= 4 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 16 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 017 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 25 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 018 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 50 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 019 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 70 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 020 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, fitting , fixing of Batten Intergated type LED fitting 40W, 4 Ft, ultra slim co- extruded polycarbonate channel with integrated electronic driver should be as per IEC: 021 62384/IS:16104( SMPS based constant current output, THD<20%), IP20 protection, color temperature=6500K, rated input voltage=230V AC, 50 Hz, power factor=0.9, view angle>=120°, lumens output not less than 100 lm/Watt, operating voltage range: 140-270 V AC. LED Should be as per LM-80/IS:16105. Fixture Size:(LXWxH=1156x25x35 mm +/-1) .
Supply, fitting, fixing of recess mounted 18 Watt LED Panel light Square( Ceiling Cut Out 175x175 mm) pressure die-cast aluminium luminaire in powder coated white finish in square 022 profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver. Lumen Output: 1260 Lumen, Color Temperature: 6500K, Voltage Widthstanding range: 140 V to 270 V AC, 50 Hz. Height of fixutre: 23 +/- 1 mm.LED Should be as per LM-80/IS:16105. LED Chip specification
Supply, installation, testing and commissioning of 1 x 10 W, 2 ft linear surface- mounted LED mirror light fixture, suitable for mirror and vanity lighting applications, comprising powder-coated aluminium housing with opal polycarbonate diffuser, high-efficiency LED module, 023 integral constant current electronic driver, system efficacy not less than 100 lm/W, CRI 80, CCT 4000 K/5700 K (as approved), operating voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, IP20 protection, minimum L70 life of 50,000 burning hours, complete with mounting accessories, testing and commissioning, conforming to relevant IS/IEC standards, complete in all respects.
Supply, installation testing and commissioning of Energy Efficient Ceiling Fan 1200 024 mm sweep BLDC motor, BEE 5 star rated ceiling fan With regulator enable motor with power of 26 watt with 10% tolerance , motor insulation B type 220-240V 50Hz single phase with Speed minimum 350 rpm minimum air delivery 225CMM complete set of 3 no's. blade , down rods, 2 nos canopies , shackle kit & all remaining accessories including nut bolts Washers complete as required .
Supply, installation, testing and commissioning of 300 mm sweep Exhaust Fan, plastic louver type, suitable for wall/window mounting, complete with high-efficiency single-phase induction motor, aerodynamically designed blades, automatic gravity louvers, bird guard, operating voltage 230 V AC, 50 Hz, low-noise operation, complete with mounting frame, fasteners, wiring up to terminal, all accessories, testing and commissioning, conforming to relevant IS/IEC standards, complete in all respects.
Supply installation of Inverter Split Air Conditioner, 1.5 Ton, BEE 5 Star Rated of wall- mounted split type with inverter compressor technology, suitable for efficient cooling with low power consumption. The AC shall have a rated cooling capacity of 1.5 Ton (approximately 5.0-5.2 kW) and shall operate on 230 V AC, 50 Hz single phase power supply. The unit shall be BEE 5 Star rated as per latest BEE norms, with ISEER value not less than 4.6 (or as per current 5-Star classification), ensuring high energy efficiency. It shall be equipped with a high-efficiency rotary inverter 026 compressor, using eco-friendly refrigerant (R-32 or equivalent), suitable for tropical climatic conditions. The indoor unit shall have a low-noise blower, uniform air distribution, washable air filters, and precise temperature control, while the outdoor unit shall be robust, weather-resistant and supplied with a heavy-duty galvanized steel / powder-coated mounting bracket for fixing the outdoor unit. The scope shall include supply and installation of required low-pressure (suction) and high-pressure (liquid) copper connecting pipes of suitable diameter and thickness, properly insulated, of required length as per site installation conditions, complete with flare nuts and fittings, ensuring leak-proof operation.The AC shall include standard safety and protection features such as overload protection, voltage fluctuation protection, and auto-restart
Supply, Installation of Pure Sine wave Inverter 5500 VA Real Power 3800 Watt, 027 Supports 4 Nos 12 V Battery, MCB protection for Input mains, Bypass switch for supplying output directly from grid in case of Home inverter fault,Protection against short-circuit, battery over-charge, deep-discharge etc.
Supply, installation, testing and commissioning of Tall Tubular Lead Acid Battery, 12 V, 150 Ah, conforming to IS 13369 / IS 1651 or latest applicable BIS standards, comprising 4 Nos. of 028 batteries, having high-pressure die-cast lead alloy grids with tubular positive plates for long service life and deep discharge capability, robust high-impact polypropylene (PP) container, low- maintenance design, suitable for inverter/UPS/DC power supply applications, complete with interconnecting links, terminal covers, mounting accessories and all materials required for proper installation, testing and commissioning, complete in all respects.
Supply, installation, testing and commissioning of 2 kVA Online UPS, true double conversion type, 72 V DC, suitable for operation supports an external battery bank 6 Nos. of 12 V , pure sine wave output, DSP/microprocessor controlled, input voltage range 160-300 V AC, output 029 voltage 230 V AC ±1%, input frequency 50 Hz ±10%, output frequency 50 Hz ±0.1%, efficiency 90% in online mode, input power factor 0.99, with overload, short-circuit, over-voltage, under-voltage and battery protection, LCD/LED display with audible alarms, RS-232/USB communication interface, manual/static bypass arrangement, complete with all mounting accessories, input/output terminals, testing and commissioning. The UPS shall conform to relevant IS/IEC standards and shall be supplied with a minimum warranty of 24 months, complete in all respects.
Supply, installation, testing and commissioning of 12 V, 100 Ah Sealed Maintenance Free (SMF) Valve Regulated Lead Acid (VRLA) Battery, suitable for UPS/inverter/DC power supply 030 applications, maintenance-free, spill-proof, rechargeable type, complete with interconnecting leads, terminal covers, mounting hardware and all accessories required for proper installation. The battery shall conform to relevant IS/IEC standards, be provided with a minimum warranty of 36 months, and include testing, commissioning and satisfactory operation, complete in all respects.
"Supply, fitting, fixing, testing and commissioning of 4-Way SMDB, 250 A (Double Door Type), suitable for indoor installation, complete with 4-pole MCCB incomer and 4-pole MCCB outgoing feeders, fabricated from CRCA sheet steel, powder-coated, and conforming to relevant IS/IEC standards. The SMDB shall consist of the following components: (i) Main SMDB Enclosure (Double Door Type) 4-way enclosure suitable for 200 A, 4-pole MCCB as incomer and 4-pole MCCBs as outgoing feeders, complete with mounting arrangements, removable gland plates, earthing terminals and adequate cable entry provisions. (ii) SMDB Bottom Cable Unit (Double Door) - 1 No. (iii) SMDB Cable Alley Unit, 250 A (Double Door Type) - 2 Nos. (iv) Metering Unit (for Double Door SMDB only) Complete with Ammeter, Voltmeter with selector switch and Phase Indicator Lamps (3 Nos.), including internal wiring and accessories. (v) SMDB Corner Units for Double Door - 4 Nos. (vi) MCCB Incomer 200 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release, complete with mounting, interconnections and protection accessories - 1 No. (vii) MCCB Outgoing Feeders 125 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 2 Nos. 100 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 1 No. 63 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 2 Nos. The SMDB shall be provided with electrolytic grade copper busbars, adequately rated for the system current and fault level, mounted on suitable insulated supports and colour coded. Internal wiring shall be carried out using PVC insulated copper conductors with proper ferruling. The panel shall be provided with earthing arrangement, labels, danger notices and circuit identification, complete in all respects. Installation shall include alignment, levelling, tightening of all electrical connections, testing of insulation resistance, functional testing and commissioning. The rate shall be inclusive of all materials, labour, tools, transportation, installation, testing, commissioning and all incidental works, complete in all respects, as per the approved specifications and directions of the Engineer-in-Charge."
Supply, fitting, fixing of wall mounted VTPN DB, Horizontal TP MCCB as incomer 4 way 032 double door , IP: 43 Protection, Shrounded Neutral Bar and pan assembly with flexible connecting link., cement spill protector, door earthing with the following:(i) MCCB 100 Amps, TPN ,25KA BC= 1 No.(ii) MCB DP 63 Amps, C series, Icn =10KA BC= 4 Nos. (iii) MCB DP 32 Amps, C series, Icn =10KA BC= 8 Nos
Supply, fitting, fixing of 200 Amps outdoor type cable junction box, angle frame 033 mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 200 Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). The base of the fedder pillar junction box to be provided with CC foundation of propotion 1:1.5:3( cement, sang,Chips) after connection of Ug cables.
Supply, installation, testing and commissioning of 15 W decorative LED Up-Down Wall Luminaire, IP66 protected, suitable for surface wall mounting, incorporating high-efficiency COB LED 034 as light source, pressure die-cast aluminium housing with polyester powder-coated finish, toughened clear glass diffuser/lens, system efficacy not less than 100 lm/W, CRI 80, CCT 3000 K/4000 K/5700 K (as approved), integral constant current electronic driver, input voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, minimum L70 life of 50,000 burning hours, complete with all mounting accessories, testing and commissioning.
Supply, installation, testing and commissioning of 15 W LED Spike Light, compact, lightweight and energy-efficient, IP66 protected, suitable for landscape and garden illumination, incorporating high-efficiency COB LED as light source, pressure die-cast aluminium housing with 035 polyester powder-coated finish, toughened clear glass lens, adjustable mounting bracket with ground spike, system efficacy not less than 100 lm/W, CRI 80, CCT 3000 K/4000 K/5700 K (as approved), integral constant current electronic driver, operating voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, minimum L70 life of 50,000 burning hours, complete with all mounting accessories,testing and commissioning.
Supply, installation, testing and commissioning of 24 W LED Post Top Landscape Luminaire, IP65 protected, warm white, comprising spun aluminium housing with opal diffuser, incorporating 3 x 8 W high-power COB LEDs as light source, complete with integral constant current 036 electronic driver, system efficacy not less than 100 lm/W, CRI 80, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, operating voltage 140-270 V AC, 50 Hz, minimum L70 life of 50,000 burning hours, mounted on 2.0 m high hot-dip galvanized steel tubular pole with base plate and foundation bolts, including excavation, PCC/RCC foundation, grouting, backfilling, cable termination, earthing connection, all mounting hardware, accessories, civil works, testing and commissioning, complete in all respects.
Supply, installation, testing and commissioning of thermoplastic cable junction box, IP66 weatherproof, suitable for outdoor installations, of size 104 mm x 104 mm x 70 mm, with metric knockouts for cable entry, complete with terminal block suitable for termination of 1.5 sq.mm to 2.5 sq.mm copper conductors, weather-resistant gasket, stainless steel fixing screws, wall mounting accessories, glands, hardware and all accessories required for complete installation.
Supply, installation, testing and commissioning of thermoplastic cable junction box, 038 IP66 weatherproof, suitable for outdoor installations, of size 130 mm x 180 mm x 77 mm, with metric knockouts for cable entry, complete with terminal block suitable for termination of 4 sq.mm to 10 sq.mm copper conductors, weather-resistant gasket, stainless steel fixing screws, wall mounting accessories, cable glands, hardware and all accessories required for complete installation.
Supply, installation, testing and commissioning of 10 W Decorative LED Gate Lamp, suitable for outdoor gate and boundary wall mounting, complete with E-27 lamp holder, 10 W LED 039 lamp having minimum 850 lumens output, weatherproof housing of IP65 protection, pressure die- cast aluminium/high-quality polycarbonate body with clear/frosted diffuser, operating voltage 140- 270 V AC, 50 Hz, CCT 3000 K/4000 K/5700 K (as approved), CRI 80, minimum LED life L70 50,000 burning hours, complete with 300 mm high mounting arrangement, internal wiring, fixing hardware, all accessories, testing and commissioning, complete in all respects.
Dismantling of existing electrical pole of any type and height, including disconnecting 040 overhead conductors/cables, dismantling all associated fittings and accessories, lowering the pole safely to ground level, stacking the released materials at the location specified by the Engineer-in- Charge within the railway premises, making the site safe and clearing all debris, complete in all respects.
C-AT TSK Division- Provision of new station building at MZS under ABSS.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 001 wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 002 wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A,ceiling rose,Modular GI metal box with suitable modules for fixing switches & Regulators and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire .
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 003 wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 6 A ,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 004 wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 005 wiring for AC point from main/sub-main board t o the points by 6 mm sq single core multi-strand FRLS copper cable through heavy duty PVC conduit pipe including MCB Protected Power Unit 16 A ,modular type having Socket, push Starter and 1.0 mm.sq. unsheathed copper cable in green colour for earth continuity wire.
Supply, drawing and connection of single core 1.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 4.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 6.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, laying, fixing, testing and commissioning of medium class rigid PVC conduit of specified size, conforming to IS 9537 (Part-3) or latest, complete with all accessories such as 011 bends, couplers, junction boxes, inspection boxes, tees, elbows, saddles, spacer bars, bushes and draw wire, laid either on surface or recessed in walls, ceilings or slabs, including painting of surface- mounted conduit to match the surroundings or cutting chases, fixing the conduit and making good the wall/plaster in case of recessed installation, complete in all respects as directed by the Engineer- in-Charge.
Erection of earth by 50 mm dia 3 Mtrs. long (Medium Gauge) GI pipe , 8 SWG GI 012 wire,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with CI plate having locking arrangement and watering pipe as per drg. Nos.PCEE/ELG/DRG/2024/1 dated 30.09.2024
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip 013 earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply, fitting, fixing, testing and commissioning of 6 way Double Door SPN MCB DB 014 with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB 32 A SP 'C' Series, 10KABC= 2 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, fitting, fixing, testing and commissioning of 8 way Double Door SPN MCB DB 015 with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB 32 A SP 'C' Series, 10KABC= 4 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, fitting, fixing, testing and commissioning of 4 way Double Door TPN MCB DB( 016 4+12) with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i) MCB 40 A TPN 'C' Series, 10KABC= 1 Nos (ii)MCB 32 A DP 'C' Series, 10KABC= 4 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 16 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 017 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores 018 Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 25 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 50 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 019 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 70 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 020 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 120 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 021 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, fitting , fixing of Batten Intergated type LED fitting 40W, 4 Ft, ultra slim co- extruded polycarbonate channel with integrated electronic driver should be as per IEC: 022 62384/IS:16104( SMPS based constant current output, THD<20%), IP20 protection, color temperature=6500K, rated input voltage=230V AC, 50 Hz, power factor=0.9, view angle>=120°, lumens output not less than 100 lm/Watt, operating voltage range: 140-270 V AC. LED Should be as per LM-80/IS:16105. Fixture Size:(LXWxH=1156x25x35 mm +/-1) .
Supply, fitting, fixing of recess mounted 18 Watt LED Panel light Square( Ceiling Cut Out 175x175 mm) pressure die-cast aluminium luminaire in powder coated white finish in square 023 profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver. Lumen Output: 1260 Lumen, Color Temperature: 6500K, Voltage Widthstanding range: 140 V to 270 V AC, 50 Hz. Height of fixutre: 23 +/- 1 mm.LED Should be as per LM-80/IS:16105. LED Chip specification
Supply, installation, testing and commissioning of 1 x 10 W, 2 ft linear surface- mounted LED mirror light fixture, suitable for mirror and vanity lighting applications, comprising powder-coated aluminium housing with opal polycarbonate diffuser, high-efficiency LED module, 024 integral constant current electronic driver, system efficacy not less than 100 lm/W, CRI 80, CCT 4000 K/5700 K (as approved), operating voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, IP20 protection, minimum L70 life of 50,000 burning hours, complete with mounting accessories, testing and commissioning, conforming to relevant IS/IEC standards, complete in all respects.
Supply, installation testing and commissioning of Energy Efficient Ceiling Fan 1200 025 mm sweep BLDC motor, BEE 5 star rated ceiling fan With regulator enable motor with power of 26 watt with 10% tolerance , motor insulation B type 220-240V 50Hz single phase with Speed minimum 350 rpm minimum air delivery 225CMM complete set of 3 no's. blade , down rods, 2 nos canopies , shackle kit & all remaining accessories including nut bolts Washers complete as required .
Supply, installation, testing and commissioning of 300 mm sweep Exhaust Fan, plastic louver type, suitable for wall/window mounting, complete with high-efficiency single-phase 026 induction motor, aerodynamically designed blades, automatic gravity louvers, bird guard, operating voltage 230 V AC, 50 Hz, low-noise operation, complete with mounting frame, fasteners, wiring up to terminal, all accessories, testing and commissioning, conforming to relevant IS/IEC standards, complete in all respects.
Supply installation of Inverter Split Air Conditioner, 1.5 Ton, BEE 5 Star Rated of wall- mounted split type with inverter compressor technology, suitable for efficient cooling with low power consumption. The AC shall have a rated cooling capacity of 1.5 Ton (approximately 5.0-5.2 kW) and shall operate on 230 V AC, 50 Hz single phase power supply. The unit shall be BEE 5 Star rated as per latest BEE norms, with ISEER value not less than 4.6 (or as per current 5-Star classification), ensuring high energy efficiency. It shall be equipped with a high-efficiency rotary inverter 027 compressor, using eco-friendly refrigerant (R-32 or equivalent), suitable for tropical climatic conditions. The indoor unit shall have a low-noise blower, uniform air distribution, washable air filters, and precise temperature control, while the outdoor unit shall be robust, weather-resistant and supplied with a heavy-duty galvanized steel / powder-coated mounting bracket for fixing the outdoor unit. The scope shall include supply and installation of required low-pressure (suction) and high-pressure (liquid) copper connecting pipes of suitable diameter and thickness, properly insulated, of required length as per site installation conditions, complete with flare nuts and fittings, ensuring leak-proof operation.The AC shall include standard safety and protection features such as overload protection, voltage fluctuation protection, and auto-restart
Supply, Installation of Pure Sine wave Inverter 5500 VA Real Power 3800 Watt, 028 Supports 4 Nos 12 V Battery, MCB protection for Input mains, Bypass switch for supplying output directly from grid in case of Home inverter fault,Protection against short-circuit, battery over-charge, deep-discharge etc.
Supply, installation, testing and commissioning of Tall Tubular Lead Acid Battery, 12 V, 150 Ah, conforming to IS 13369 / IS 1651 or latest applicable BIS standards, comprising 4 Nos. of 029 batteries, having high-pressure die-cast lead alloy grids with tubular positive plates for long service life and deep discharge capability, robust high-impact polypropylene (PP) container, low- maintenance design, suitable for inverter/UPS/DC power supply applications, complete with interconnecting links, terminal covers, mounting accessories and all materials required for proper installation, testing and commissioning, complete in all respects.
Supply, installation, testing and commissioning of 2 kVA Online UPS, true double conversion type, 72 V DC, suitable for operation supports an external battery bank 6 Nos. of 12 V , pure sine wave output, DSP/microprocessor controlled, input voltage range 160-300 V AC, output 030 voltage 230 V AC ±1%, input frequency 50 Hz ±10%, output frequency 50 Hz ±0.1%, efficiency 90% in online mode, input power factor 0.99, with overload, short-circuit, over-voltage, under-voltage and battery protection, LCD/LED display with audible alarms, RS-232/USB communication interface, manual/static bypass arrangement, complete with all mounting accessories, input/output terminals, testing and commissioning. The UPS shall conform to relevant IS/IEC standards and shall be supplied with a minimum warranty of 24 months, complete in all respects.
Supply, installation, testing and commissioning of 12 V, 100 Ah Sealed Maintenance Free (SMF) Valve Regulated Lead Acid (VRLA) Battery, suitable for UPS/inverter/DC power supply 031 applications, maintenance-free, spill-proof, rechargeable type, complete with interconnecting leads, terminal covers, mounting hardware and all accessories required for proper installation. The battery shall conform to relevant IS/IEC standards, be provided with a minimum warranty of 36 months, and include testing, commissioning and satisfactory operation, complete in all respects.
"Supply, fitting, fixing, testing and commissioning of 4-Way SMDB, 250 A (Double Door Type), suitable for indoor installation, complete with 4-pole MCCB incomer and 4-pole MCCB outgoing feeders, fabricated from CRCA sheet steel, powder-coated, and conforming to relevant IS/IEC standards. The SMDB shall consist of the following components: (i) Main SMDB Enclosure (Double Door Type) 4-way enclosure suitable for 200 A, 4-pole MCCB as incomer and 4-pole MCCBs as outgoing feeders, complete with mounting arrangements, removable gland plates, earthing terminals and adequate cable entry provisions. (ii) SMDB Bottom Cable Unit (Double Door) - 1 No. 032 (iii) SMDB Cable Alley Unit, 250 A (Double Door Type) - 2 Nos. (iv) Metering Unit (for Double Door SMDB only) Complete with Ammeter, Voltmeter with selector switch and Phase Indicator Lamps (3 Nos.), including internal wiring and accessories. (v) SMDB Corner Units for Double Door - 4 Nos. (vi) MCCB Incomer 200 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release, complete with mounting, interconnections and protection accessories - 1 No. (vii) MCCB Outgoing Feeders 125 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 2 Nos. 100 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 1 No. 63 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 2 Nos. The SMDB shall be provided with electrolytic grade copper busbars, adequately rated for the system current and fault level, mounted on suitable insulated supports and colour coded. Internal wiring shall be carried out using PVC insulated copper conductors with proper ferruling. The panel shall be provided with earthing arrangement, labels, danger notices and circuit identification, complete in all respects. Installation shall include alignment, levelling, tightening of all electrical connections, testing of insulation resistance, functional testing and commissioning. The rate shall be inclusive of all materials, labour, tools, transportation, installation, testing, commissioning and all incidental works, complete in all respects, as per the approved specifications and directions of the Engineer-in-Charge."
Supply, fitting, fixing of wall mounted VTPN DB, Horizontal TP MCCB as incomer 4 way 033 double door , IP: 43 Protection, Shrounded Neutral Bar and pan assembly with flexible connecting link., cement spill protector, door earthing with the following:(i) MCCB 100 Amps, TPN ,25KA BC= 1 No.(ii) MCB DP 63 Amps, C series, Icn =10KA BC= 4 Nos. (iii) MCB DP 32 Amps, C series, Icn =10KA BC= 8 Nos
Supply, fitting, fixing of 200 Amps outdoor type cable junction box, angle frame 034 mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 200 Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). The base of the fedder pillar junction box to be provided with CC foundation of propotion 1:1.5:3( cement, sang,Chips) after connection of Ug cables.
Supply, installation, testing and commissioning of 15 W decorative LED Up-Down Wall Luminaire, IP66 protected, suitable for surface wall mounting, incorporating high-efficiency COB LED 035 as light source, pressure die-cast aluminium housing with polyester powder-coated finish, toughened clear glass diffuser/lens, system efficacy not less than 100 lm/W, CRI 80, CCT 3000 K/4000 K/5700 K (as approved), integral constant current electronic driver, input voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, minimum L70 life of 50,000 burning hours, complete with all mounting accessories, testing and commissioning.
Supply, installation, testing and commissioning of 15 W LED Spike Light, compact, lightweight and energy-efficient, IP66 protected, suitable for landscape and garden illumination, incorporating high-efficiency COB LED as light source, pressure die-cast aluminium housing with 036 polyester powder-coated finish, toughened clear glass lens, adjustable mounting bracket with ground spike, system efficacy not less than 100 lm/W, CRI 80, CCT 3000 K/4000 K/5700 K (as approved), integral constant current electronic driver, operating voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, minimum L70 life of 50,000 burning hours, complete with all mounting accessories,testing and commissioning.
Supply, installation, testing and commissioning of 24 W LED Post Top Landscape Luminaire, IP65 protected, warm white, comprising spun aluminium housing with opal diffuser, incorporating 3 x 8 W high-power COB LEDs as light source, complete with integral constant current 037 electronic driver, system efficacy not less than 100 lm/W, CRI 80, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, operating voltage 140-270 V AC, 50 Hz, minimum L70 life of 50,000 burning hours, mounted on 2.0 m high hot-dip galvanized steel tubular pole with base plate and foundation bolts, including excavation, PCC/RCC foundation, grouting, backfilling, cable termination, earthing connection, all mounting hardware, accessories, civil works, testing and commissioning, complete in all respects.
Supply, installation, testing and commissioning of thermoplastic cable junction box, IP66 weatherproof, suitable for outdoor installations, of size 104 mm x 104 mm x 70 mm, with metric knockouts for cable entry, complete with terminal block suitable for termination of 1.5 sq.mm to 2.5 sq.mm copper conductors, weather-resistant gasket, stainless steel fixing screws, wall mounting accessories, glands, hardware and all accessories required for complete installation.
Supply, installation, testing and commissioning of thermoplastic cable junction box, 039 IP66 weatherproof, suitable for outdoor installations, of size 130 mm x 180 mm x 77 mm, with metric knockouts for cable entry, complete with terminal block suitable for termination of 4 sq.mm to 10 sq.mm copper conductors, weather-resistant gasket, stainless steel fixing screws, wall mounting accessories, cable glands, hardware and all accessories required for complete installation.
Supply, installation, testing and commissioning of 50 W Decorative LED Post Top Lantern complete with 5.0 m high decorative hot-dip galvanized GI/MS pole, suitable for outdoor lighting applications, having Victorian aesthetic design with pressure die-cast aluminium housing, graphite grey polyester powder-coated finish, frost clear PMMA diffuser and optical grade clear PMMA optics, complete with high-brightness LED module of 50 W system power, Type-II light 040 distribution, system efficacy not less than 100 lm/W, CRI 70, CCT 5700K ±500K, IP65 protection for optical and control gear compartments, IK07 impact resistance, integral constant current electronic driver, internal surge protection of 5 kV and external surge protection of 10 kV, operating voltage 150-270 V AC, 50 Hz, power factor 0.95, THD 15%, Class-I electrical safety, minimum LED life L70 50,000 burning hours at 25°C, mounted on 5.0 m decorative pole complete with base plate, foundation bolts, excavation, PCC/RCC foundation, grouting, backfilling, cable termination, earthing connection, all mounting hardware, wiring, accessories, testing and commissioning, complete in all respects.
Dismantling of existing electrical pole of any type and height, including disconnecting 041 overhead conductors/cables, dismantling all associated fittings and accessories, lowering the pole safely to ground level, stacking the released materials at the location specified by the Engineer-in- Charge within the railway premises, making the site safe and clearing all debris, complete in all respects.
D-AT TSK Division- Provision of new station building at SPTR under
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 001 wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 002 wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A,ceiling rose,Modular GI metal box with suitable modules for fixing switches & Regulators and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire .
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 003 wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 6 A ,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type 004 wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire.
Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type 005 wiring for AC point from main/sub-main board t o the points by 6 mm sq single core multi-strand FRLS copper cable through heavy duty PVC conduit pipe including MCB Protected Power Unit 16 A ,modular type having Socket, push Starter and 1.0 mm.sq. unsheathed copper cable in green colour for earth continuity wire.
Supply, drawing and connection of single core 1.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 4.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, drawing and connection of single core 6.0 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site.
Supply, laying, fixing, testing and commissioning of medium class rigid PVC conduit of specified size, conforming to IS 9537 (Part-3) or latest, complete with all accessories such as 011 bends, couplers, junction boxes, inspection boxes, tees, elbows, saddles, spacer bars, bushes and draw wire, laid either on surface or recessed in walls, ceilings or slabs, including painting of surface- mounted conduit to match the surroundings or cutting chases, fixing the conduit and making good the wall/plaster in case of recessed installation, complete in all respects as directed by the Engineer- in-Charge.
Erection of earth by 50 mm dia 3 Mtrs. long (Medium Gauge) GI pipe , 8 SWG GI 012 wire,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with CI plate having locking arrangement and watering pipe as per drg. Nos.PCEE/ELG/DRG/2024/1 dated 30.09.2024
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip 013 earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply, fitting, fixing, testing and commissioning of 6 way Double Door SPN MCB DB 014 with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB 32 A SP 'C' Series, 10KABC= 2 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, fitting, fixing, testing and commissioning of 8 way Double Door SPN MCB DB 015 with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB 32 A SP 'C' Series, 10KABC= 4 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, fitting, fixing, testing and commissioning of 4 way Double Door TPN MCB DB( 016 4+12) with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i) MCB 40 A TPN 'C' Series, 10KABC= 1 Nos (ii)MCB 32 A DP 'C' Series, 10KABC= 4 Nos (iii) MCB 16 A SP 'C' Series, 10KABC= 2 Nos (iv)MCB 10 A SP 'C' Series, 10KABC= 2 Nos
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 16 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 017 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 25 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 018 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 50 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 019 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 70 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 020 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 120 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. 021 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024
Supply, fitting , fixing of Batten Intergated type LED fitting 40W, 4 Ft, ultra slim co- extruded polycarbonate channel with integrated electronic driver should be as per IEC: 022 62384/IS:16104( SMPS based constant current output, THD<20%), IP20 protection, color temperature=6500K, rated input voltage=230V AC, 50 Hz, power factor=0.9, view angle>=120°, lumens output not less than 100 lm/Watt, operating voltage range: 140-270 V AC. LED Should be as per LM-80/IS:16105. Fixture Size:(LXWxH=1156x25x35 mm +/-1) .
Supply, fitting, fixing of recess mounted 18 Watt LED Panel light Square( Ceiling Cut Out 175x175 mm) pressure die-cast aluminium luminaire in powder coated white finish in square 023 profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver. Lumen Output: 1260 Lumen, Color Temperature: 6500K, Voltage Widthstanding range: 140 V to 270 V AC, 50 Hz. Height of fixutre: 23 +/- 1 mm.LED Should be as per LM-80/IS:16105. LED Chip specification
Supply, installation, testing and commissioning of 1 x 10 W, 2 ft linear surface- mounted LED mirror light fixture, suitable for mirror and vanity lighting applications, comprising powder-coated aluminium housing with opal polycarbonate diffuser, high-efficiency LED module, 024 integral constant current electronic driver, system efficacy not less than 100 lm/W, CRI 80, CCT 4000 K/5700 K (as approved), operating voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, IP20 protection, minimum L70 life of 50,000 burning hours, complete with mounting accessories, testing and commissioning, conforming to relevant IS/IEC standards, complete in all respects.
Supply, installation testing and commissioning of Energy Efficient Ceiling Fan 1200 025 mm sweep BLDC motor, BEE 5 star rated ceiling fan With regulator enable motor with power of 26 watt with 10% tolerance , motor insulation B type 220-240V 50Hz single phase with Speed minimum 350 rpm minimum air delivery 225CMM complete set of 3 no's. blade , down rods, 2 nos canopies , shackle kit & all remaining accessories including nut bolts Washers complete as required .
Supply, installation, testing and commissioning of 300 mm sweep Exhaust Fan, plastic louver type, suitable for wall/window mounting, complete with high-efficiency single-phase 026 induction motor, aerodynamically designed blades, automatic gravity louvers, bird guard, operating voltage 230 V AC, 50 Hz, low-noise operation, complete with mounting frame, fasteners, wiring up to terminal, all accessories, testing and commissioning, conforming to relevant IS/IEC standards, complete in all respects.
Supply installation of Inverter Split Air Conditioner, 1.5 Ton, BEE 5 Star Rated of wall- mounted split type with inverter compressor technology, suitable for efficient cooling with low power consumption. The AC shall have a rated cooling capacity of 1.5 Ton (approximately 5.0-5.2 kW) and shall operate on 230 V AC, 50 Hz single phase power supply. The unit shall be BEE 5 Star rated as per latest BEE norms, with ISEER value not less than 4.6 (or as per current 5-Star classification), ensuring high energy efficiency. It shall be equipped with a high-efficiency rotary inverter 027 compressor, using eco-friendly refrigerant (R-32 or equivalent), suitable for tropical climatic conditions. The indoor unit shall have a low-noise blower, uniform air distribution, washable air filters, and precise temperature control, while the outdoor unit shall be robust, weather-resistant and supplied with a heavy-duty galvanized steel / powder-coated mounting bracket for fixing the outdoor unit. The scope shall include supply and installation of required low-pressure (suction) and high-pressure (liquid) copper connecting pipes of suitable diameter and thickness, properly insulated, of required length as per site installation conditions, complete with flare nuts and fittings, ensuring leak-proof operation.The AC shall include standard safety and protection features such as overload protection, voltage fluctuation protection, and auto-restart
Supply, Installation of Pure Sine wave Inverter 5500 VA Real Power 3800 Watt, 028 Supports 4 Nos 12 V Battery, MCB protection for Input mains, Bypass switch for supplying output directly from grid in case of Home inverter fault,Protection against short-circuit, battery over-charge, deep-discharge etc.
Supply, installation, testing and commissioning of Tall Tubular Lead Acid Battery, 12 V, 150 Ah, conforming to IS 13369 / IS 1651 or latest applicable BIS standards, comprising 4 Nos. of 029 batteries, having high-pressure die-cast lead alloy grids with tubular positive plates for long service life and deep discharge capability, robust high-impact polypropylene (PP) container, low- maintenance design, suitable for inverter/UPS/DC power supply applications, complete with interconnecting links, terminal covers, mounting accessories and all materials required for proper installation, testing and commissioning, complete in all respects.
Supply, installation, testing and commissioning of 2 kVA Online UPS, true double conversion type, 72 V DC, suitable for operation supports an external battery bank 6 Nos. of 12 V , pure sine wave output, DSP/microprocessor controlled, input voltage range 160-300 V AC, output 030 voltage 230 V AC ±1%, input frequency 50 Hz ±10%, output frequency 50 Hz ±0.1%, efficiency 90% in online mode, input power factor 0.99, with overload, short-circuit, over-voltage, under-voltage and battery protection, LCD/LED display with audible alarms, RS-232/USB communication interface, manual/static bypass arrangement, complete with all mounting accessories, input/output terminals, testing and commissioning. The UPS shall conform to relevant IS/IEC standards and shall be supplied with a minimum warranty of 24 months, complete in all respects.
Supply, installation, testing and commissioning of 12 V, 100 Ah Sealed Maintenance Free (SMF) Valve Regulated Lead Acid (VRLA) Battery, suitable for UPS/inverter/DC power supply 031 applications, maintenance-free, spill-proof, rechargeable type, complete with interconnecting leads, terminal covers, mounting hardware and all accessories required for proper installation. The battery shall conform to relevant IS/IEC standards, be provided with a minimum warranty of 36 months, and include testing, commissioning and satisfactory operation, complete in all respects.
"Supply, fitting, fixing, testing and commissioning of 4-Way SMDB, 250 A (Double Door Type), suitable for indoor installation, complete with 4-pole MCCB incomer and 4-pole MCCB outgoing feeders, fabricated from CRCA sheet steel, powder-coated, and conforming to relevant IS/IEC standards. The SMDB shall consist of the following components: (i) Main SMDB Enclosure (Double Door Type) 4-way enclosure suitable for 200 A, 4-pole MCCB as incomer and 4-pole MCCBs as outgoing feeders, complete with mounting arrangements, removable gland plates, earthing terminals and adequate cable entry provisions. (ii) SMDB Bottom Cable Unit (Double Door) - 1 No. 032 (iii) SMDB Cable Alley Unit, 250 A (Double Door Type) - 2 Nos. (iv) Metering Unit (for Double Door SMDB only) Complete with Ammeter, Voltmeter with selector switch and Phase Indicator Lamps (3 Nos.), including internal wiring and accessories. (v) SMDB Corner Units for Double Door - 4 Nos. (vi) MCCB Incomer 200 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release, complete with mounting, interconnections and protection accessories - 1 No. (vii) MCCB Outgoing Feeders 125 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 2 Nos. 100 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 1 No. 63 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release - 2 Nos. The SMDB shall be provided with electrolytic grade copper busbars, adequately rated for the system current and fault level, mounted on suitable insulated supports and colour coded. Internal wiring shall be carried out using PVC insulated copper conductors with proper ferruling. The panel shall be provided with earthing arrangement, labels, danger notices and circuit identification, complete in all respects. Installation shall include alignment, levelling, tightening of all electrical connections, testing of insulation resistance, functional testing and commissioning. The rate shall be inclusive of all materials, labour, tools, transportation, installation, testing, commissioning and all incidental works, complete in all respects, as per the approved specifications and directions of the Engineer-in-Charge."
Supply, fitting, fixing of wall mounted VTPN DB, Horizontal TP MCCB as incomer 4 way 033 double door , IP: 43 Protection, Shrounded Neutral Bar and pan assembly with flexible connecting link., cement spill protector, door earthing with the following:(i) MCCB 100 Amps, TPN ,25KA BC= 1 No.(ii) MCB DP 63 Amps, C series, Icn =10KA BC= 4 Nos. (iii) MCB DP 32 Amps, C series, Icn =10KA BC= 8 Nos
Supply, fitting, fixing of 200 Amps outdoor type cable junction box, angle frame 034 mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 200 Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). The base of the fedder pillar junction box to be provided with CC foundation of propotion 1:1.5:3( cement, sang,Chips) after connection of Ug cables.
Supply, installation, testing and commissioning of 15 W decorative LED Up-Down Wall Luminaire, IP66 protected, suitable for surface wall mounting, incorporating high-efficiency COB LED 035 as light source, pressure die-cast aluminium housing with polyester powder-coated finish, toughened clear glass diffuser/lens, system efficacy not less than 100 lm/W, CRI 80, CCT 3000 K/4000 K/5700 K (as approved), integral constant current electronic driver, input voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, minimum L70 life of 50,000 burning hours, complete with all mounting accessories, testing and commissioning.
Supply, installation, testing and commissioning of 15 W LED Spike Light, compact, lightweight and energy-efficient, IP66 protected, suitable for landscape and garden illumination, incorporating high-efficiency COB LED as light source, pressure die-cast aluminium housing with 036 polyester powder-coated finish, toughened clear glass lens, adjustable mounting bracket with ground spike, system efficacy not less than 100 lm/W, CRI 80, CCT 3000 K/4000 K/5700 K (as approved), integral constant current electronic driver, operating voltage 140-270 V AC, 50 Hz, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, minimum L70 life of 50,000 burning hours, complete with all mounting accessories,testing and commissioning.
Supply, installation, testing and commissioning of 24 W LED Post Top Landscape Luminaire, IP65 protected, warm white, comprising spun aluminium housing with opal diffuser, incorporating 3 x 8 W high-power COB LEDs as light source, complete with integral constant current 037 electronic driver, system efficacy not less than 100 lm/W, CRI 80, power factor 0.95, THD 10%, surge protection minimum 2.5 kV, operating voltage 140-270 V AC, 50 Hz, minimum L70 life of 50,000 burning hours, mounted on 2.0 m high hot-dip galvanized steel tubular pole with base plate and foundation bolts, including excavation, PCC/RCC foundation, grouting, backfilling, cable termination, earthing connection, all mounting hardware, accessories, civil works, testing and commissioning, complete in all respects.
Supply, installation, testing and commissioning of thermoplastic cable junction box, IP66 weatherproof, suitable for outdoor installations, of size 104 mm x 104 mm x 70 mm, with metric knockouts for cable entry, complete with terminal block suitable for termination of 1.5 sq.mm to 2.5 sq.mm copper conductors, weather-resistant gasket, stainless steel fixing screws, wall mounting accessories, glands, hardware and all accessories required for complete installation.
Supply, installation, testing and commissioning of thermoplastic cable junction box, 039 IP66 weatherproof, suitable for outdoor installations, of size 130 mm x 180 mm x 77 mm, with metric knockouts for cable entry, complete with terminal block suitable for termination of 4 sq.mm to 10 sq.mm copper conductors, weather-resistant gasket, stainless steel fixing screws, wall mounting accessories, cable glands, hardware and all accessories required for complete installation.
Supply, installation, testing and commissioning of 50 W Decorative LED Post Top Lantern complete with 5.0 m high decorative hot-dip galvanized GI/MS pole, suitable for outdoor lighting applications, having Victorian aesthetic design with pressure die-cast aluminium housing, graphite grey polyester powder-coated finish, frost clear PMMA diffuser and optical grade clear PMMA optics, complete with high-brightness LED module of 50 W system power, Type-II light 040 distribution, system efficacy not less than 100 lm/W, CRI 70, CCT 5700K ±500K, IP65 protection for optical and control gear compartments, IK07 impact resistance, integral constant current electronic driver, internal surge protection of 5 kV and external surge protection of 10 kV, operating voltage 150-270 V AC, 50 Hz, power factor 0.95, THD 15%, Class-I electrical safety, minimum LED life L70 50,000 burning hours at 25°C, mounted on 5.0 m decorative pole complete with base plate, foundation bolts, excavation, PCC/RCC foundation, grouting, backfilling, cable termination, earthing connection, all mounting hardware, wiring, accessories, testing and commissioning, complete in all respects.
Dismantling of existing electrical pole of any type and height, including disconnecting 041 overhead conductors/cables, dismantling all associated fittings and accessories, lowering the pole safely to ground level, stacking the released materials at the location specified by the Engineer-in- Charge within the railway premises, making the site safe and clearing all debris, complete in all respects.
Item Breakup - A-AT TSK Division- Provision of new station building at DMC under ABSS.
32 mm dia Total 84700.00
Item Breakup - B-AT TSK Division- Provision of new station building at NLP under ABSS.
32 mm dia Total 84700.00
Item Breakup - C-AT TSK Division- Provision of new station building at MZS under ABSS.
32 mm dia Total 84700.00
Item Breakup - D-AT TSK Division- Provision of new station building at SPTR under ABSS.
32 mm dia Total 84700.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
LVT14TSK950.pdf
ATTACHMENT
AnexxuresSectionVIINew.pdf
ATTACHMENT
GCCACS11_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].