Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC 1000 PUDA MODEL TOWN PHASE 5 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹37.1 L+₹3.2 L (9.57%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹37.3 L+₹3.4 L (10.2%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹38.3 L+₹4.4 L (13.1%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹40.4 L+₹6.5 L (19.2%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
25 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda, Military Engineer Services, Bathinda Military Station, Bathinda, Punjab-151004
REPAIRS TO FLOOR, WALL, PLASTER, PLINTH PROTECTION AND OTHER B/R WKS IN CERTAIN MD ACCN UNDER THE AOR OF GE (NORTH) BATHINDA AT BATHINDA MIL STN.
2021_MES_416680_1
CWE BTD-76/2020-21
Open Tender
Civil Works
Item Rate
180 days
Bathinda Mil Station
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE North Bathinda
₹1.1 L
Yes
3 Mar 2021
28 Jan 2021
27 Feb 2021
28 Jan 2021
25 Feb 2021
12 Feb 2021
28 Jan 2021 - 3 Feb 2021
60 days
Amount
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces / stone masonry in cement mortar (1:6), finishing the surface even and smooth without using extra cement.
M & L for preparation of newly plastered surfaces of internal walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of 100% acrylic emulsion paint by using airless spray/ roller over and including a coat of acylic internal primer. Note :- Contractor may use manual tools for surface preparation with prior approval of Engg- in- charge in writing in case use of mechanical equipments are not possible.
M&L for rendering 5 mm thick in cement mortar in (1:3) finishing the surfaces even and smooth on ceiling complete all as specified.
M&L for preparation of newly plastered or unplastered surface and applying three coats of white wash on ceilings.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish to a distance as directed by Eng-in-Charge.
M & L for vitrified ceramic tiles, 9 to 10 mm thick (square / rectangular), ultracharged, polished, light shade, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles including M&L for 15 mm thick Screed bed or bedding layer in CM (1:6). Note: Only course sand shall be used in screed bed.
All as per item No 7 above but in vertical surfaces such as steps , riser , skirting, dado and pillars as directed at site including 10 mm thick rendering as backing coat in cement mortar (1:4). Note: Only course sand shall be used in screed bed.
S&F glazed ceramic coloured tiles 450 x 350mm, 7 to 8mm thick in verticle surfaces such as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement pigmented to the match the shade of tiles laid over and including 10 mm thick rendering in cement mortar (1:4) as backing coat and finish the surface rough to receive the tile. Note: Only course sand shall be used in screed bed.
M & L for non skid coloured ceramic tiles of size minimum 300mm x 300mm, 7 to 8 mm thick (square/rectangular), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile with including 15 mm thick Screed bed or bedding layer in CM (1:6) complete all as specified. Note: Only course sand shall be used in screed bed.
M & L for non skid coloured ceramic tiles of size minimum 400mm x 400mm, 7 to 8 mm thick (square/rectangular), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile with including 15 mm thick Screed bed or bedding layer in CM (1:6) complete all as specified. Note: Only course sand shall be used in screed bed.
Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each and re-fixing in the same opening including easing and adjusting including renewal of unserviceable screws etc complete.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each and removing from site including cutting holes for removal of hold fast complete.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified in Preamble 8B.3.1 of SSR Part -II (2010) and all as shown on drawing of SSR Part-II (2010).
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement all as per instruction and drawing shown for item No 8080 of SSR Part II.
Demolition of PCC in ground floors and pavings not exc 15cm thickness (below or above ground level) and removing rubbish to a distance all as directed by Eng-in-Charge.
M&L for 75 mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement.
M&L for water proofing treatment over RCC slab by applying oil bound bituminous primer @ 0.30 kg/Sqm and providing and laying 3 mm thick APP modified water proofing memberane weighing not less than 3.50 kg/sqm, reinforced with non woven polyester reinforcement matt weighing not less than 160 gm/Sqm polyester core, having soften point not less than 150°C, longitudinal tensile strength not less than 650 N/ 5 cm, tearing strength of 180 N, torch application, side overlap 75 mm and end overlap 100 mm including ponding test all as specified and directed including demolition of existing treatment including plaster and removing the rubbish to a distance exceeding 1 km but not exceeding 2 km.
M&L for applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg / Sqm including cleaning surfaces.
M&L for wire brushing and cleaning top surfaces of roof slabs etc, including washing the roof surface with water and making the surface free from mud etc complete all as specified.
M&L for 15 mm thick screed bed or bedding layer in cement mortar (1:3) on roof surfaces parapet or vertical beam surface (horizental or vertical) finishing the surfaces even and fair complete all as specified. (Note :- Course sand (Toka sand) shall only be used in screed bed/plastering.)
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar (1:3).
Supply only liquid water proofing material, ISI marked.
S&F 1000 litres capacity Rotational moulded polyethylene in white colour, three layered, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old water tank of any size and any type and removing from site all as directed.
All as per item No 24 above but capacity of tank 500 litres.
M & L for 15 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors including taking up or down 15 mm bore existing steel tubing and connections complete.
M & L for 20 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors including taking up or down 20 mm bore existing steel tubing and connections complete.
S&F in repairs vitreous china wash down water closet pan (EWC) white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe etc and white coloured plastic seat cover and mild steel chromium plate or aluminised hinging device complete.
S & F in repairs PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe 32mm dia 900 mm long complete.
S & F in repairs vitreous china wash hand basin, white, of size 550mm x 400mm, excluding waste, chain and plug and porcelain stopper but including 32 mm dia waste coupling fancy type chromium plated, and PVC waste pipe of 32 mm dia and fixed all as directed complete .
Supply only 15mm bore chromium plated, fancy type, quarter turn Pillar cock screwed down high pressure, with or without lettered Hot ot Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified.
M&L for rubber moulded chequered cement concrete tiles with grey cement and pigments, 25cm x 25cm x 22-25mm/ or 30cmx 30cm x 22- 25mm thick, coloured & design as approved, set, jointed and pointed in neat cement slurry as in floors etc; laid over & including 15mm thick screed in CM (1:6), complete all as specified including dismantling of existing chequered tiles.
S & F MS framed work such as grills, gratings, guard bars etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290 Gde E-165 including dismantling the existing mild steel work.
S&F in replacement PVC Bathroom mirror cabinet 400 mm x 500 mm (compact mirror cabinet , concealed slabs) incl taking down old cabinet any type complete all as specified and directed by Engineer-in-charge.
S&F in replacement corner/glass shelf with bracket fixed on wall with CP brass screws and PVC plug incl taking down od any type of shelf complete all as specified and as directed by Engineer-in-charge
S&F PVC (SWR) 110mm bore pipes single socketed, ISI marked, in any length with rubber ring joints, fixed to walls including taking down old pipes and fittings.
S&F in repairs drapery rod (conduit) of dia not less than 25mm duly powder coated of shade as decided by Engr-in-Charge including ABS plastic finials of approved shade and including standard MS poder powder coated brackets fixed to walls with rawl plugs and steel screws complete.
S&F stainless steel butt hinges 100 mm.
S&F stainless steel handle 125 mm.
S&F stainless steel tower bolt 150 mm.
M/s Balvinder Singh Engineer and Contractors
R K GOYAL & COMPANY
M/s MITTAL CONSTRUCTIONS
SHARDA ENTERPRIES
M/s DHEERAJ JAIN CONSTRUCTION COMPANY
M/S VERMA BUILDERS & DEVELOPERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .