Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.4 LAccepted-AOC | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹58.2 L+₹2.9 L (5.20%)Rejected-Finance METHOPARA GANGANAGAR KOLKATA 700132 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700132 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹58.4 L+₹3.1 L (5.51%)Rejected-Finance GR 8 ADDA BUILDING 1ST FLOOR CITY CENTRE DURGAPUR 16 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
12 Oct 2022, 12:30 pmClosed
EE/BED/PWDTE
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
Repairing and renovation of internal EI along with fitting fixture, improvement of compound illumination, DG, Water Purifier and LED signage at District Library Building, Bankura
2022_WBPWD_409967_1
WBPWDTE/EE/BED/NIQ_89/Q of 2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Wise
60 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1.1 L
22 Nov 2022
23 Sept 2022
14 Oct 2022
23 Sept 2022
12 Oct 2022
23 Sept 2022
Amount
Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire(KEI/MESCAB/POLYCAB) partly in 20mm size PVC rigid conduit 'FRLS' (Precision make) [for horizontal run & above false ceiling portion only] and in 19 mm bore, 3mm thick polythene pipe [for vertical run embedded in wall],to light/fan/call bell points with Modular type switch as per GS with following average run. 10 Mtr. [ 5 (e) / E- 25 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with Modular type plug socket & switch as per GS. On Board [ 3 (i) / E- 20 ]
Avg run 6 mtr
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. [6(a)/E-3]
Cutting Channel of size (31 mm x 31 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13 mm dia 3 mm thick polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. [8(a)/E-3]
Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ]
2x (6 sqmm) + 1x (4 sqmm) [ 1 (y) / E- 9 ]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 200 x 150 x 65 [11(d)/E-4]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12 Way[ Legrand/cabtree/seimens ] [ 13 / D- 9 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS. Make - [ Legrand/cabtree/seimens ] 6 Way [ 14 / D- 10 ]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS Make - [ Legrand/cabtree/seimens ] 12 Way ( Up to 160 A ) [15 / D- 11 ]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS Make - [ Legrand/cabtree/seimens ] 8 Way ( Up to 160 A ) [15 / D- 11 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS Make - [ Legrand/cabtree/seimens ] 40 A DP [ 6 / D- 5 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS Make - [ Legrand/cabtree/seimens ] 6-32 SP [ 7 / D- 6]
40 A TPN [ 8 / D- 7]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS Make - [ Legrand/cabtree/seimens ] 160 A FP [ 10/ D- 8 ]
Supplying and fixing 415V, FP Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as per GS [Make L &T/Havells/Standard] [3(a)/D-2] 160 A
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall as per GS.( Make -Siemens/ L&T/Havells ). 415 A [4(a)/D-3]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB vertical enclosure with IP-42/43 as per GS 4/6 /8 /12Way [16/D-12]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make / Fort Gloster/KEI/polycab/mescab/havells] 4Core 35 Sq. mm [ NS ]
4Core 16 Sq. mm [ NS ]
4Core 70 Sq. mm [ NS ]
4Core 120 Sq. mm [ NS ]
4Core 185 Sq. mm [ NS ]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes. 2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Above 35 sqmm to 95 sqmm [ 5(ii)/ F- 3 ]
Above 95 sqmm [ 5(iii)/ F- 3 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4Core 35 Sq. mm [7(d)/F4 & 8(b) /F5]
4Core 16 Sq. mm [7(c)/F4 & 8(b) /F5]
4Core 70 Sq. mm [7(d)/F4 & 8(b) /F5 ]
4Cor 120 Sq. mm [7(d)/F4 & 8(b) /F5]
4Cor 185 Sq. mm [7(d)/F4 & 8(b) /F5]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as per G.S
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS [ 12 /E-18 ]
Supply & Fixing 240 V, 2 nos. 5 A, 3 pin Modular type plug socket with 2 nos. 5 A Modular type switch (Brand approved by EIC), Indicator without plug top on GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc, with connector as per G.S.
Fixing only florescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports etc as per G.S [ 15 / C-2 ]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit as per GS [16/C-2 ]
Supply of 4 Ft. single/twin LED light fitting for indoor application,complete with all accessories & LED tubes having following Model / Cat No.( Make -Philips) aTMC 501 P1xT-LED 22wP3241 with 18 master tube.
aTMC 501 P2xT-LED 22wP3242 with 2 nos 18 master tube.
S&F 9 W LED light fitting. Make Philips
S&F Cirrus surface mounted luminaire for 2x2 grid ceiling [ Make Philips / Bajaj/HavellsType SM366C LED33-6500 PSU-OD WH] for Library hall in Gnd Floor)
S & F Green LED Ultima Round False Celling Light Model no-DN092B LED 6S-6500 PSU WH Make - Philips /Havells/ Crompton
Supply & Fixing 240 V Modular Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board as per GS [ 10 / E-18 ]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Fixing only exhaust fan after making holes in wall as per GS (12") [ 28(b)/C-4 ]
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS (12") [ 33/D-14 ]
Supply & Fixing of 200mm dia PVC decorative ceiling cover plate for ceiling fans
Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves ) a. 1400 mm Sweep ( Aura Metallic / USHA STRIKER)
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) 12"( 300mm ) Speed 920 RPM
S & F 450 mm Wall Fan Tornado Wall II Make -Orient/Usha/Crompton
S&F OLP-3 incorporated in a box having a 20amp MCB SPN ,compsit flash type 250 V. 6 pin 25 Amp. Plug socket with 25Amp MCB. in the box made of 16 SWG CRC sheet with bakelite top cover and earthing attachment in conceal in wall as per G.S.
S&F sheet metal 2 module Anodised box in conceal in wall incl S & Fbase & top incl S & F 25A capacity 5 pin base & Top North Make and earthing attachment as per G.S.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS 4SWG [5(a)(i)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2]
Dismentaling of 1 no panel Taking down 80 nos of tube light, 60 nos fan , wire and cables etc. As per EIC
S & F sheet metal 16 SWG iron clad Busbar chamber on angle iron frame on wall incl earthing attachment as per G.S 4 bar 415V 600A D-12/19(a)
Supplly & fixing Medium gauge GI pipe (ISI -Medium) Protection With Necy fitting and jointing materials as required F- 6/11
S& F G.I Loop box of size 8''x6"x2 with Hing type door and door locking arrangement incl S&F 250 V 3 way AC/DC make bakelite terminal in conceal in in wall after cutting the wall & mending good damage as per dir of EIC
Supply & Delivery of 1.1KV Gr. following Al, PVC / XLPE Armoured cable make: Havells/Glostar/KEI as per direction of EIC. 2 Core 10 Sqmm
Laying of cable upto 35 sqmm in underground trench as per GS for the following numbers of Cables. 1 No Cable [ 1(a)/ F- 2 ]
S&F Compression type cable gland incl. finishing the end of the cable by S&F Al. Socket, Tapes etc. by crimping method as per GS. of following size. 2 Core 10 Sqmm
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with porcelan insulator as per GS
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with porcelan insulator spaced not exceeding 1000 mm as per GS
S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1) [ 14 / J2 ]
Making soldered joints between conductor/ conductor & air terminals by 7/10 stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint. [ 12(a) / J2 ]
Making soldered joints between conductor/ down pipes / other metallic objects by 7/10 stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of Binous paint.[ 12(b)/J2 ]
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S&F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required [ 13 / J2 ]
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works. Length upto 0.5 Mtr [ 4(a) / J1 ]
Length above 0.5 Mtr [ 4(b) / J1 ]
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run [ 7 / J1 ]
Excavation of soil for installation of Earth Electrode and filling& ramming. For Soft Soil [ 1(a) / G1 ]
For Morrum Soil [ 1(b) / G1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below. By TATA-Medium GI pipe
S& F sheet metal Loop box of size 8''x6"x2 1/2" made of 14 SWG CRC Sheet with Hing type door and door locking arrangement incl S&F 250 V 3 way AC/DC make bakelite terminal in conceal in in wall after cutting the wall & mending good damage as per dir of EIC
Supply, installation, testing and commissioning of new CPCB-II compliant 3Phase, 415V, 50Hz, 125KVA Silent Diesel Generator Set comprising of Engine, Alternator, STD AMF Panel, Base Frame, Fuel Tank, Batteries, CPCB approved Acoustic Enclosure having following specification and engine should not derate at 50Deg C ambient temperature. Engine: a) Make: CUMMINS/ASHOK LEYLAND/CATER PILLAR b) BHP - Minimum 155BHP c) Aspiration - Turbo charged air to air cooled d) No. of Stroke / Cylinder - 4 Stroke/6 Cylinder in line e) RPM - 1500 f) Battery - As per manufacturer standard. g) Type of Cooling - Water/Liquid cooled. h) Air Intake System - Air intake manifold with air airfilter system. i) Exhaust System - Provided with turbo charger & residential exhaust silencer with flexible bellow and companijon flanges insijde the acoustic enclosure. j) Coupling & Flywheels - Befitting coupling with single bearing system. k) Lubricating system - Provided with Oil Pan, engine mounted lube oil pump and lube oil filter along with first fill of lube oil. l) Fuel System - Comprising of manufacturers standard fuel pump with electronic governor, 12V Solenoid coil and replaceable fuel filter. m) Starting system - 12V DC Electric Start. n) Engine Protections - Low lube oil pressure/high coolant temp./over speed. Alternator a) Make: Stamford/Leroy Somer/Crompton Greaves b) Rating - 125KVA c) Type of Alternator - Brushless, self excited & self regulated. d) Voltage Regulation - ±1% (max) in static condition. e) Overload - Permissible overload of 10% for 1 hour in 12 hours of operation. f) Protection - IP-23 protection with Class-H insulation. g) Enclosure Type: SPDP Base Frame Common MS Channel fabricated base frame, primer coated & painted, containing the engine and the alternator mounted through AVM Pads. Fuel Tank - Minimum 175Ltrs detachable tank built inside acoustic enclosure complete with drain valve, air vent, inlet & outlet connections, fuel gauge. Acoustic Enclosure Specially designed to meet stringent MOEF/CPCB Norms of 75dBA @ 1Mtr. At 75% load under free field conditions. The Acoustic Enclosure is made of CRCA sheets and structural sheet metal base frame painted in black. a) High quality noise absorbant and fire retardant grade acoustic insulation material (PU Foam/Rock Wool complying to IS:8183. b) Two point lifting for easy handling at customer site. c) Designed to have optimum serviceability. d) Air inlet louvers specially designed to operaate at rated load. e) 9/11 tank pretreatment process and UV resistant Powder coating of all parts to withstand extreme environment. f) Use of special hardware for longer life. g) Fluid drains for lube oil and fuel. h) Fuel filling arrangement inside the enclosure. AMF Panel AMF Control Panel fabricated from 16SWG CRCA sheet and powder coated after 7 tank treatment process and to be accommodated inside the canopy. The panel comprises of following items :- a) 200Amps, 4Pole, 36ka Microprocessor based MCCB with all protections for Mains & DG - 2 Nos. a.1) 200Amps, 4Pole, AC-1 Duty Power Contactor with NO+NC Contacts for DG & Mains - 2 Nos. b) Electronic Voltage Regulator for Mains Contactor. 1 No. c) Required Add on Blocks for Contactors d) Required 6A-SP & 16A-DP MCB of 10Ka e) Indicating lamps 230V AC (LED type) - Mains ON, DG ON, Mains Load ON/DG Load ON f) Start/Stop Push Button should be available in the AMF Controller. g) Aux. Relay as required. h) 3Phase Voltage monitoring Relay. i) ON Delay Timer, Coil voltage 230AC j) Auto Trickle & Boost type Battery charger, 12V k) Microprocessor based AMF Controller having all inbuilt display features for engine & alternator and protections for Engine & alternator. l) Aluminium Bus Bar of rated capacity and size m) Make - OEM Make. AMF Panel should have bypassing Changeover system with 2 nos 200 Amp changeover switch a) Efficiency: As per manufacturers declared value. b) Warranty - 18 months from the date of supply or 12 months from the date of commissioning, whichever is earlier. c) Test Certificates of Engine & Alternator should accompany the Bill.
Filling of HSD oil for initial refill with transportation.
Supply and delivery of best quality oil hand pump with 1" dia PVC flexible pipe (10 mtr. approx.)
Supply and delivery of 200 ltr. Capacity heavy gauge MS sheet barrel.
S& laying 50 sq. mm. single core multistrand PVC insulated flexible Cu cable in uPVC / GI pipe from earth electrode to neutral earth busbar and from earth busbar to DG neutral point as required (for neutral earthing)
S& laying 2.5 sq. mm. 10core multi core multistrand PVC insulated flexible Cu cable in uPVC / GI pipe from DG to separate AMF panel.
Finishing the cable ends by crimping method incl. S&F copper socket, insulating tape and jointing materials etc. as required suitable for single core 70 sq. mm. copper wire.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode [3(b)/G-2]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS No.-4 SWG [5(a)(i)/G-2]
No.-6 SWG [5(a)(ii)/G-2]
Connecting the equipments body to earth busbar including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [5(d)/G-3)]
Earth work in excavation of foundation trenches of drains, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.( Depth of Excavation not exceeding 1500 mm ) [ Page- 1, Item no.- 2(a) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Earth work in filling in foundation trench or plinth with good earth in layers Board a) With earth obtained from excavation of foundation 1/5th of excavated earth [ Page 1, Item no.3(a) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Filling in foundation or plinth by silver sand in layer a) With earth obtained from excavation of foundation 1/5th of excavated earth [ Page- 2, Item no.- 4(A) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Single Brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand [ Page- 14, Item no.1 of PWD Schedule of Rates, Volume-I of Building Works, 2017]
Base foundation for the installation of D.G ( appx Base size L-4000 mm x W- 2000 mm x H-800mm Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.. A)For works in foundation and top of ground floor / upto 4 m i) Tor steel/ Mild steel SAIL/ TATA/RINL. [ Page- 43, Item no.40(a)(i)(I) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Ordinary Cement concrete pakur variety (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. [ Page- 16, item no.-16 of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Plaster (to wall, floor, ceiling etc.) of 10 mm thick with sand and cement with 1:4 cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] [ Page- 189, item no.-1(ii)-(c) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE: Cement 0.152 cu.m per 100 sq.m. [ Page- 192, item no.-15 of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
SITC OF GREEN MODEL COOLER CUM PURIFIER WITH EXTERNAL DIAMENSIONS (WxDxH)- 750x570x1350 IN MM (EQUIVALENT OR +- 5% ACCEPTED), OPERATING POWER SUPPLY-230 ± 10 % V AC, 50 HZ, RUNNING CURRENT IN AMPS (MAX)-4.0 ± 10 %,POWER IN WATTS-850 ± 10 %,WATER STORAGE TANK CAPACITY-120 LTR,CAPACITY WITH COMFORT LEVEL WATER OUTLET TEMPERATURE AT 17 DEG C-60 LPH,REFRIGENT-R134 22,COMPRESSOR MAKE- EMERSON,THERMAL INSULATION FOR STORAGE TANK-PUF,TOTAL NO. OF FAUCETS-03 (1 NORMAL+2 COLD), RECOMMENDD MAX WATER FLOW RATE THROUGH THE FAUCETS IN LPM-1.5,NO OF STAGES FOR FILTER CUM PURIIER-03,NO OF PURIFIER CIRCUITS-03,PURIFIER FAULT INDICATION (BUZZER),VISUAL CONTROL (LEDS),WATER FLOW SWITH,10 MINUTES UV AUTO SHUT OFF, WITH 120 LTRS STORAGE CAPACITY ,STORGE TANK MATERIAL & BODY MATERIAL- FRONT SS 304 & REST PRE COATED STEEL,WORKING WITH -0.4 KG/CC MIN. WATER INPUT PRESSURE AND 2 KG/CC OF MAX. WATER INPUT PRESSURE, INTEGRATED WATER COOLER CUM PURIFIER WITH ENDPOINT PURIFICATION TECHNOLOGY, INCLUDING 1 YEAR WARRENTY AS PER CONDITION. MAKE EUREKA FORBES/KENT/ION EXCHANGE
S & F Iron Guard for water purifier
S & F angle Iron Structure of Suitable Dimension for Fixing 120ltr water cooler cum purifier on angle iron structure. The height of the angle iron structure must be 1 ft from level
S& F sheet metal Loop box of size 8''x6"x2 1/2" made of 14 SWG CRC Sheet with Hing type door and door locking arrangement incl S&F 250 V 3 way AC/DC make bakelite terminal in conceal in in wall after cutting the wall & mending good damage as per dir of EIC
S& F G.I Loop box of size 8''x6"x2 with Hing type door and door locking arrangement incl S&F 250 V 3 way AC/DC make bakelite terminal in conceal in in wall after cutting the wall & mending good damage as per G.S I-2/ 16
S & F of Led flood lighting luminaire with single die ceramic base high power LED , LED , PDC Housing and Unique flood Optics (NB) to Ensure uniform distribution , maintenance free system, ideal for area lighting Model No- LCNP-80- CDL/60M-M Make - Philips/Havells/ Crompton
S & F Led Post Top Light model no BGP161 LED2300/WW PSU 220-240 V 7043 IN Make Philips/Havells/ Crompton
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make- Fort Gloster/ RR CABLE /POLYCAB/havells/ KEI] 4 Core 10 Sq. mm [ NS ]
4 Core 6 Sq. mm [ NS ]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes. 2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4Core 6 Sq. mm [7(a)/F4 & 8(b) /F5]
4Core 10 Sq. mm [7(c)/F4 & 8(b) /F5]
Timer Panel:Supplying and fixing (2+12)way Legrand DB enclosure for housing the following A) One no.single dial digital timer ( Make :Legrand/L&T ) B)One no. FP pole, conctractor,(L&T/ABB) C) One no. FP 63A MCB D) One no. auto/manual Toggel Switch and other required material The complete arrangement must be wiring by PVC insulated Cu wire as per GS
"Supply and fixing of special type Imported acrylic Letter approx. 50mm thickness flushed in ACP Board made of imported Acrylic ACAST sheet.enclosed . The facia should be made of imported Acrylic ACAST sheet . provision should be as such that Inside each letterHeat sinkable LED lights will glow throughout the letter. S/F of 12'x6'x10"" ACP sheet of 4mm thickness fixed on iron frame, on which the letters will be fixed.The remaining five sides of board also shall be covered with ACP Sheet. The Letters will be as follows:- (matter taken from authority in later) Installation of the above mention board by expert labour on the suitable size angle grouted in the parapit with suitable size angle iron frame iron angle. Additional arrangement to support the board by iron structure grouted on roof and internal wiring connection as per direction of E.I.C Transportation of the above board ( Kolkata to site location ) incl. unloading and placed to site properly. (NS)
Supply & Erection of Self Supporting Special type MS Structure with suitable height made from 50 mm dia hollow pipe 50 x 50 x 8 mm & 40 x 40 x 6 mm MS angle incl. S&F Anodised GI sheet for cover up the D.G set incl other necy materials as per direction of E.I.C ( Drawing & Details of Structure to be submitted & approved by E.I.C before taking up the work)
SITC of Cabinet Loudspeaker of model LB2-UC15-D1 of Bosch or similar model of other renouned make as per direction of the EIC with Rated power (PHC) 15 W, Power tapping 15/7.5/3.75/1.9 W, Sound pressure level at ratedpower / 1 W (1 kHz, 1 m)99/87 dB (SPL), Effective frequency range (-10 dB) 95 Hz to 20 kHz, Opening angle at 1 kHz / 4 kHz(-6 dB)184° / 112° (hor.), 170° / 35° (ver.) Rated input voltage 11/70/100 V, Rated impedance 8/ 326/ 667 ohm , Transducers 101.6 mm (4”) woofer, 13 mm, (0.51”) dome tweeter (Approved Make: ELectro Voice/QSC/Bosch/Bose/Meyer Sound)
SITC of Mixer Amplifier of model PLE-1ME240-3IN of Bosch or similar model of other renouned make as per direction of the EIC with 240 W, 4 microphone/line inputs and 1 BGM input, USB/Bluetooth. Voltage 220-230 V, AC, 50 Hz /240W, Inrush current 40A, Frequency response 80 Hz to 18 kHz (+1/ 3 dB @ 10 dB ref. rated output), Distortion <1% @ rated output power, 1 kHz , Bass Control Max. ± 8 dB,Treble Control Max. ± 8 dB, AUX input , Connector Cinch, stereo converted to mono, Sensitivity 200 mV to 300 mV, Impedance 22kohm S/N (flat at max. volume) ≥70 dB, Headroom >25 dB , Insert 1 x Connector RCA Cinch, Sensitivity 1 V, Impedance >10 kohm, 100 V and 4-ohm loudspeaker outputs (Approved Make: ELectro Voice/QSC/Bosch/Bose/Meyer Sound)
SITC of Booster Amplifier of model LBD1935/00 of Bosch or similar model of other renouned make as per direction of the EIC with Input Voltage : 230VAC ±10% at 50/60Hz or 24VDC, Inrush Curren: 9A at 230 VAC, 11A at 24 VDC, Rated Output (RMS) 240W, Frequency response: 60 Hz to 18 kHz (+1 / -3 dB at -10 dB ref. rated output), Distortion: <1% at rated output, 1 kHz, S/N (flat at max volume: > 85 dB, Line Inputs: 2x 3-pin XLR, balanced, Line l oop through output: 2x 3-pin XLR, Loudspeakers outputs : 3 x 100 V, 70 V, 8/4 ohm (Approved Make: ELectro Voice/QSC/ Bosch/ Bose/ Meyer Sound)
SITC of 15U Rack& Accessories (Approved Make: Valrack /Rittal/APW/Netrack/D-link)
SITC of 2Core 2.5Sqmm Cable (Approved Make: Polycab /Finolex/Mescab)
Cutting Channel of size (31 mm x 31 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13 mm dia 3 mm thick polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. [8(a)/E-3]
Supply of Handheld cordless micro phone model no SVX24/PG58 make- SHURE/SONY/ LACTROSONI
Supply of Vocal micro phone model no SM-58-LC Dynamic with stand and XLR cable make- SHURE/SONY/ LACTROSONI
S & F overhead projecter Make- SONY/ EPSON/PANASONIC model no- EB 525W
Supply & Fixing White board 6ft x 4 ft make- Liberty & other equivalent Make
S & F of HDMI /VGA cable & VGA to HDMI Converter Power Cable with Pvc Conduit
R K ENTERPRISE
DURGAPUR POWER
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .