Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.7 LAccepted-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | 1 | Accepted-AOC The lowest tenderer | |
| 2 | 2₹28.5 L+₹1.8 L (6.68%)Rejected-Finance 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | 2 | Rejected-Finance Not the lowest tenderer | |
| 3 | 3₹32.6 L+₹5.9 L (22.2%)Rejected-Finance T 16 1 SHETTY HOTEL OLD NAVY NAGAR COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | 3 | Rejected-Finance Not the lowest tenderer | |
| 4 | 4₹33.2 L+₹6.4 L (24.1%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | 4 | Rejected-Finance Not the lowest tenderer | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to unlisted contractor |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
17 Sept 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) Navy Nagar
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR REPLACEMENT OF INTERNAL WATER SUPPLY AND ALLIED WORKS AT RS COLABA AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2020_MES_371230_1
8402/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D and category a(ii)
7 documents required · 7 mandatory
₹500
GE (NW) Navy Nagar
₹96,000
27 Nov 2020
21 Aug 2020
18 Sept 2020
21 Aug 2020
17 Sept 2020
4 Sept 2020
21 Aug 2020 - 10 Sept 2020
60 days
Amount
Supply and Fixing in repair/ replacement of internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge of following sizes :-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50mm bore
Supply and laying in repairs 3 layer (Inner antimicrobial, outer UV stablized) ISI marked , IS-15801, PPR Pipes SDR 7.4 (PN16) and PPR plain fittings in trenches/walls/celings or laying in floor complete of sizes outer dia as below Make : SFMC/Prince/KPT
20mm bore
25mm bore
Supply and fix in repair/replacement of PPR Gate Valve 50mm in existing line in position , made out of brass screwed both ends for PPR pipe with union, ISI marked complete all as directed.
Supply & fix in repair of PVC(LLDPE) rectangular loft tank of net capacity 275 Ltrs with gross capacity of tank at least 5% in excessof minimum net capacity including 03 Nos adopter with washer for inlet/outlet overflow pipe as per manufacturere s instruction and overall dimension as 995-1200mm length , 620-820mm with 285-485mm height , 300mm internal dia of hand hole,minimum wall thickness 2.75mm( weight of tank 11 Kgs) with lid cover complete all as specified and directed by Engineer-in- Charge.
Supply and fix in repair/replacement PVC profile suitable for 275 ltrs loft tank including fixing of aluminium channel around the profile complete all as specified and directed.
Supply and fix in repair/replacement bronze pressure reducing valve suitable for 25 mm bore GI pipe with diaphram cover, spring clamps, cast iron body scatting and adjustable screws and stop valve of chromium plated carbon steel strainer, screw of stain less steel for domestic water supply, suitable for inlet pressure as per IS-7939, including GI pipe connection as required, the work to be carried out from G+14 floor on plain wall with necessary bamboo scaffolding complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair CP stop cock, screwed down with crutch or butterfly handle suitable for GI tubing 15 mm dia bore including necessary clamp & saddles all as specified.
Supply and fix in repairs CP bib cock, with crutch or butterfly handle screwed both ends for GI tubing 15 mm dia bore including necessary clamp & saddles etc all as specified.
Dismantling of existing connection and taking out pressure reducing valve of size 25 mm bore cleaning servicing and refixing at existing location in high rise buildings (G+14) including provision of fittings, I.e. union, elbow, bend, nipple, etc. complete to make the line functional all as specified.
Supply and fix in repair brass float valve (ISI marked) high pressure with polythelene float (flat) and fly nut complete screwed for GI pipe 15mm bore including necessary GI fittings such as elbow, reducer, nipple etc.
All as per item No 10.00 above but for GI pipe 20 mm bore
All as per item No 10.00 above but for GI pipe 25 mm bore
All as per item No 10 above but for GI pipe 40 mm bore
Supply and fix in repair/replacement of gun-metal, gate valve in existing line in position with iron wheel head class I, made out of brass, screwed both ends for GI pipe with union, ISI marked complete all as directed of the following :-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F in repairs shower rose CP 125mm dia swivel type suitable for 15mm bore GI tubing
Taking out existing unserviceabe FRP for lid cover for PVC water storage tank complete with accessories for closing and locking arrnagement suitable for 5000 Ltrs as approved BMC.
Taking out existing unserviceabe FRP for lid cover for PVC water storage tank complete with accessories for closing and locking arrnagement suitable for 2000 Ltrs as approved BMC.
Taking down GI tubing fixed to wall at location cleaning and refixing the same with clamping on wall including provision of necessary fitting in high rise building (G+15 stories) for the following
15 mm bore
20 mm bore
25 mm bore
40 mm bore
Attending ,repair of internal water supply complaints in Old and New Navy Nagar area ,repair, replacement of unserviceable bib tap,stop cock removal of airlock,tightening of leaking pipes/valves ,repair to concealed pipe line and other work pertains to internal water supply all as directed. Note: (a) Major items required to be replaced will be measured and paid separtely under revelant schedule. (b) Complaints should be taken from complaint cell or also through telephone by JE E/M and AGE W/S by your representative every day including sunday and holiday. (c) Complaints should be attended immediately and shall report the Engineer-in-charge/JE E/M after completion within 6 Hours. (d) In case the nature of job is such that the work cannot be completed within a period of 6 hours then the same shall be brought to the notice of the GE/ AGE W/S and the period for the completion of the complaints shall be decided by the GE/Engr-in-charge. (e) Contractor representative /Engineer will report to JE E/M in charge or AGE E/M at forenoon and afternoon to collect routine urgent works till completion of the CA . (f) The transportation /T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same.
Unity Enterprises
Shetty Construction Co
BOB ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .