Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC BIDHAN PALLY OODLABARI P O MANABARI P S MALBAZAR DIST JALPAIGURI | JALPAIGURI | L1 | Accepted-AOC Accepted | |
| 2 | L2₹42.9 L+₹1.2 L (2.80%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹44.7 L+₹2.9 L (6.96%)Rejected-Finance C O UTTAM BANIK HAIDERPARA OPPOSITE TO WEST BENGAL REPRESENTATIVE REST HOUSE P O HAIDERPARA SILIGURI 06 | JALPAIGURI | WEST BENGAL | 734006 | L3 | Rejected-Finance Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SEVOKE ROAD
GE SEVOKE ROAD POST SALUGARA DIST JALPAIGURI
REPAIR OF PUMP AND MOTOR AND STREET LIGHT AND EXTERNAL ELCTRIFICATION AT BAGRAKOTE UNDER GE SEVOKE ROAD
2022_MES_502563_1
GE/SEV/60 OF 2021-22
Open Tender
Civil Works
Item Rate
270 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹90,000
Yes
28 Mar 2022
19 Jan 2022
17 Feb 2022
19 Jan 2022
15 Feb 2022
3 Feb 2022
20 Jan 2022 - 29 Jan 2022
60 days
Amount
Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick, all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply & laying in trenches clear sand for cushioning under cable 8 cm below and 15 cm above complete in level all as specified and directed by Engr-in-Charge. Note:- Punned thickness shall be measured.
Supply and laying burnt clay sub class B brick as cable protection all as specified and directed.
M&L for PCC (1:2:4) type B-1 (20 mm graded stone aggregate) as in coping/ fundation for grouting, finished even and smooth without using extra cement complete all as specified and directed.
M & L for laying LT underground Cable, including takingdown existing u/s XLPE insulated, heavy duty armoured sheathed 1100 volts grade 16 Sq mm, 2 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified.
All as per item No 07 above but 10sqmm, 4 core all as specified.
All as per item No 07 above but 25sqmm, 3.5 core all as specified.
All as per item No 07 above but 50sqmm, 3.5 core all as specified.
All as per item No 07 above but 70sqmm, 3.5 core all as specified.
All as per item No 07 above but 120sqmm, 3.5 core all as specified.
All as per item No 07 above but 150sqmm, 3.5 core all as specified.
All as per item No 07 above but 185sqmm, 3.5 core all as specified.
M & L GI tubing of 50 mm bore light grade with all fittings fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor all as specifed and directed.
M & L GI tubing of 80 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor all as specifed and directed.
M&L for boring holes 1mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position ) earth pit not less than 2.25 mtrs below normal ground level with the top edgeof the earth plate not less than 1.5 mtr (B.G.L.) & connected to galvanised iron strip 25 x 4mm by means of bolts,nuts,checknuts & washer of galvanised iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made pf 6 mm round bar, including necessary excavation & earth work in any type of soil , 20 mm dia med grade galavinised steel tube for watering with one end fixed with cast iron funnel & wire mesh, 32 mm bore light grade galvanised steel tubing for proctection & common salt , charcoal in alternate layers etc. complete all as shown in EP no 3 of SSR Part 1 & testing on complection.
Supply, install, testing & commissioning in repair of approved factory made outdoor cubical type LT feeder piller Box (CPRI tested) outdoor type suitable for 3 phase 4 wire 415V,50 Hz, IP-54 of appropriate size as approved by Engr-in-charge totally enclosed weather, dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 3.15mm thick CRCA (cold rolled cold annealed )MS sheet bend to shape, front & back side operated double door with proper hinge and locking arrangement with Al bus bar fixed on porcelain insulator and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of Cu conductor and coloured coded aluminium strips should be used for connecting all MCCBs from busbar either incoming or outgoing, also MCB SPN/TPN should be wired with 16 sqmm FR coloured Al wire . Bus bar shall be insulated with colour code/sleeves/tapes including necessary PCC (1:3:6)type C2 for foundation /Platform all as specified and directed. LT panel board shall be complete in all respects with and including the following incoming/outgoing accessories: Note: All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands. The various feeders shall be indicated by font size not less than 20 mm letters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. The platform shall be such that it is of a height 45 cm above the nearest road level.
S & F in repair 5 KW ,three phase automatic Street Light timer switch for automatic switching on/off street light based on lux level of nature light, consisting of sensor overload protection fuse gear, power contactor & MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole/Wall mountable elcosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 66 with universal lock and key arrangement complete all as specified and as directed by Engr- in- Charge.
M&L for taking up/lifting of defective submersible motor and pump assembly complete of any type/size upto 20 HP with unserviceable cable of any make and capacity from deep tube/bore well (of any depth) after providing lifting tools and tackles complete as required at site, carefully disconnecting of all electric connections, water connections in and including dismantling of column pipe lines shaft (of any size and length stage by stage) and keeping them aside under safe custody for reuse at site complete all as specified and directed by Engr-in-charge
M&L for lowering of repaired submersible motor and pump assembly complete of any type/size upto 20HP capacity with submersible cable of any make and size complete in deep tube/bore well of any depth coupling with pump and motor, in and including connecting and lowering of old or new column pipe line shaft of any size and length (stage by stage) carefully with the help of necessary tools and tackles, reconnecting of all electric and water connections with new nuts bolts washers and rubber gasket and testing on load upto the entire satisfaction of Engr-in-charge complete all as specified and directed. Note: Column pipe will be measured seperately.
M&L for transportation of defective submersible pump set to workshop dismantling the same incl disconnecting electrical connections decoupling 440 volt AC submersible motor pump set of following capacities, dismantling the motor,taking out burnt winding wire from the stator, cleaning of the casing and the stator with wire brush, rewinding of motor with superior quality copper winding wire of existing size including varnishing and drying, cable jointing and repair replacement of worn out parts of pump, reassembling the same with motor installing the motor and pump , reconnecting all pipe and electric connections and testing on full load complete :- Note: Spare parts shall be measured & paid seperately under respective item as supply only. Cost of rewiring and rewinding materials is included in quoted rate.
10 HP to 15HP capacity three phase
5HP to 7.5HP capacity three phase
1.5 HP to 3.0 HP capacity.
S&F in repair flat submersible motor cable, three core, copper conductor of size 6.0 sqmm, including providing necessary connection and testing on completion complete all as specified and directed.
All as per item No. 24 here in before but flat submersible cable of size 4.0 Sqmm
Supply only following spare parts suitable for submersilble pump set vertical type (05 HP to 15 HP ) complete all as specified and as directed.
Stainless steel impeller as per existing
Thrust bearing as per exsiting
Thrust plate set as per existing
Sand guard as per existing
Stainless steel bush as per existing
Pump shaft as per existing
Supply only following spare parts suitable for submersilble pump set vertical type (1.5 HP to 3 HP ) complete all as specified and as directed.
Stainless steel impeller as per existing
Thrust bearing as per exsiting
Thrust plate set as per existing
Sand guard as per existing
Stainless steel bush as per existing
Pump shaft as per existing
Development of tube well using conventional method by means of air compressor of suitable capacity at least 10 hours minimum till sand-free / mud-free clean water is obtained complete all as specified and directed.
Supply only column pipe 100mm dia GI pipe heavy grade, 3 meter in length & both ends long threaded, including provision of heavy duty coupling / socket dia 100 mm complete all as specified and directed
Supply only column pipe 80mm dia GI pipe heavy grade, 3 meter in length & both ends long threaded, including provision of heavy duty coupling / socket having dia 80 mm complete all as specified and directed
Supply only column pipe 50mm dia galvanised iron heavy grade, 3 meter in length & both ends long threaded, including provision of heavy duty coupling / socket having dia 50 mm complete all as specified and directed
M&L for transportation of defective pump set to workshop dismantling the same incl Disconnecting electrical connections decoupling 440 volt AC Centrifugal electrical motor pump set of capacities 10 to 15HP, dismantling the motor,taking out burnt winding wire from the stator, cleaning of the casing and the stator with wire brush, rewinding of motor with superior quality copper winding wire of existing size including varnishing an drying, cable jointing and repair replacement of worn at parts of pump reassembling the same with motor installing the motor and pump , reconnecting all pipe and electric connections and testing on full load complete :- Note : Spare parts replaced shall be measured & paid seperately under respective item of schedule. Cost of rewiring and winding materials is included in item rate.
Supply and fix in repair Fully automatic three phase star delta starter in sheet metal enclosure type with overload, shortckt, single phasing, locked rotor, earth fault, current unbalance, phase sequence reversal, under current, over/uner voltage protections for following mentioned capacity motor complete all as specified and directed by Engr-in-charge.
5 HP to 10HP
S & F in repair DOL submerssible pump controller in sheet metal enclosure MRG2 type Make: L & T Cat Part SS97725 or equivalenet from make mentioned in list of makes for 3 HPMotor 230V, 50Hz, 1phase all as specified and directed by Engr-in-Charge
S & F in repair DOL submerssible pump controller in sheet metal enclosure MUG-6 type Make: L & T Cat Part SS97756 equivalenet from make mentioned in list of makes coto for 3 HP Motor 415V, 50Hz, 3phase all as specified and directed by Engr-in-Charge
Labour only for taking down any unserviseable street light fittings/flood light/garden light/gate light/fountain light fitting any type/size and refixing same after repair/replacement of all unserviceable accessories of any type and size from existing position/location or removing connection oxide by cleaning terminals and shifting materials to store for keeping in safe custody for repair work or taking credit all as specified and as directed. (Note: Items if required for repair work will be measured and paid seperately under relevant items)
Supply only new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium street security light with high power LED as light source lamp type 72W with SPD, IP 66 protection with toughened glass cover incl fixing GI pipe & bracket complete all as specified and as directed.
M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed.
Supply and fixing thermoplastic polycarbonate cable junstion box having protection IP 66 "dust proof, acid resistant, shock proof, fire retardent self extinguisher" for outside installation with knockout entry for cable of size 04 - 10 sqmm and 130x180x77mm with terminals, brackets for street light pole mounting and provision of one 6A MCB SP all as specified and as directed.
Supply only decorative LED post top lantern fitting Ruby (clear) 15 watt, IP 65 protection with pressure die cast powder coated housing and PC diffuser luminaire for 230 volt AC suitable for pole dia 50mm, including connecting wire from junction box complete all as directed.
SRI SURAJIT SENGUPTA
M/s. STRUCTURES INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .