Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC | L1 | Accepted-AOC Found reasonable for acceptance | |
| 2 | L2₹12.9 L+₹1.9 L (17.6%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹12.9 L+₹2.0 L (18.0%)Rejected-Finance H NO 190 S 4 CHODANKAR RESIDENCY NEAR GANPATI TEMPLE CENTRAL HORTA AQUEM BAIXO NAVELIM SALCETE GOA 403707 | SOUTH GOA | GOA | 403707 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹13.1 L+₹2.1 L (19.3%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted |
Tender Value
₹14.7 L
EMD Value
₹29,300
Closing Date
19 Sept 2022, 6:00 pmClosed
GE (P) Navy Mandovi
GE (P) Navy Mandovi Military Engineer Services INS Mandovi
As per tender documents
2022_MES_530135_3
8438/E8 GE (P) NAVY MANDOVI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Mandovi
As per tender documents
7 documents required · 7 mandatory
₹500
GE (P) Navy Mandovi
₹29,300
Yes
26 Oct 2022
18 Aug 2022
22 Sept 2022
18 Aug 2022
19 Sept 2022
5 Sept 2022
18 Aug 2022 - 4 Sept 2022
Amount
M & L for taking out old unserviceable existing earthing any type and providing chemical earthing with copper earth plate 90cm x 60cm x 5 mm thick and copper earth strip 32 x 6 mm upto 7.5 RM complete all as specified and directedd. Note:- On testing after completion if the desired earth resistance (< 5.0 Ohm) is not obtained, the earthing shall be redone at no extra cost.
M & L for taking out old unserviceable earting and providing earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly on ground earth pit n. less than 2.25 m deep below the ground bend with top edge of the plate n. less than 1.5m below ground level connected to GI strip of size 32 x 6 mm as earth lead by means of bolts, nuts, checks nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber cover and light grade GI pipe 40 mm dia for protection of earth strip and GI wire etc complete all as per electrical plate No. 3 of SSR Part-I including connecting with earth testing point and testing on completion; complete all as specified and directed. Notes:- 1. GI earth strip 32 x 6mm beyond 7.5 RM shall be measured and paid seperately under relevant item of this schedule. 2. On testing after completion if the desired earth resistance is not obtained, the earthing shall be redone at no extra cost.
M & L for taking out old unserviceable earting and providing earthing complete with copper earth plate electrode 30cm x 30cm x 3.15 mm thick burried directly on ground earth pit n. less than 2.25 m deep below the ground bend with top edge of the plate n. less than 1.5m below ground level connected to copper strip of size 20 x 3 mm as earth lead by means of bolts, nuts, checks nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber cover and light grade GI pipe 40 mm dia for protection of earth strip and GI wire etc complete all as per electrical plate No. 3 of SSR Part-I including connecting with earth testing point and testing on completion; complete all as specified and directed. Notes:- 1. Copper earth strip 20 x 3mm beyond 7.5 RM shall be measured and paid seperately under relevant item of this schedule. 2. On testing after completion if the desired earth resistance is not obtained, the earthing shall be redone at no extra cost.
M & L for taking out old unserviceable earting and providing earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly on ground earth pit n. less than 2.25 m deep below the ground bend with top edge of the plate n. less than 1.5m below ground level connected to GI earth wire 4 mm by means of bolts, nuts, checks nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber cover and light grade GI pipe 20 mm dia for protection of earth strip and GI wire etc complete all as per electrical plate No. 3 of SSR Part-I including connecting with earth testing point and testing on completion; complete all as specified and directed. Note:- On testing after completion if the desired earth resistance is not obtained, the earthing shall be redone at no extra cost.
S & F in repairs air termination, single pointed, copper rod 12mm dia and 300mm long mounted on GI pipe 40mm dia light grade embedded in mass PCC complete all as specified and directed.
M & L for taking out old unserviceable earth conductor providing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, 25 X 3 mm Aluminium strip alongwith Elapp DMC/ Epoxy electrical Insulator (red) complete all as specified and directed.
M & L for taking out old unserviceable earth conductor providing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required copper strip of 20mm x 3 mm alongwith Elapp DMC/ Epoxy electrical Insulator (red) complete all as specified and directed.
M & L for providing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required galvanised iron strip of 32mm x 6 mm alongwith Elapp DMC/ Epoxy electrical Insulator (red) complete all as specified and directed.
S& F in repairs test point terminal block made of gun metal or phosphorus bronze/ copper, of size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw to be housed in a closed PC/ metallic box 150 x 150 x 3 mm with opening arrangement for testig purposes, proper holes n up/ down side complete all as specified and directed.
S & F in repairs steel tubing of 40 mm dia bore, medium grade, galvanised with all fittings, laid in trenches or fixed to walls or poles for mechanical protection of earth strip etc complete all as specified and directed.
M & L for providing PCC 1:2:4, type B1, using 20mm graded crushed stone aggregate as in bed block, coping cells etc. or pipe of lightning arrester complete all as specified and directed.
S & F in repairs solar LED aviation light for fixing on top of OHT of 18 mtr height having following specification complete all as specified and directed:- (a) Aviation Light - LED Type (RED) (b) No. of LED- 12Nos. (High Brightness LED) (c) Operating Voltage- 12V DC (d) Electronics- Microcontroller based (e) Charge Controller- Inbuilt (f) Sun-Switch- Inbuilt (g) Solar Panel- 10W/12V X 2Nos (h) Battery (SMF)- 18Ah/12V (j) Operation- Flashing Light (k) Dome- UV Stabilized Polycarbonate Lens (l) Light Operation- Automatic Dusk to Dawn (m) Body- Aluminum Cast (water proof) (n) Model - Flashing Make - Navaid Energy Private Limited, Noida ( ISO 9001:2008 Certified and registered with NSIC and SSI) or equivalent ISI marked
Prabha Electricals and Communications
Sagar Constructions
DOGRA ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .