| 1 | L1₹17.8 LAccepted-AOC 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.8 L+₹1.3 L (7.07%)Rejected-Finance M S KEWAL SONS SHIVA JI NAGAR GALI NO 1 MODEL TOWN PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹20.6 L+₹2.2 L (11.9%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹20.9 L+₹2.5 L (13.5%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
26 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PATHANKOT
HQ CWE PATHANKOT
REPAIR/ REPLACEMENT OF HT OH/ UG SYSTEM, GOD SWITCEH, SF6/ VCB/ RMUS OF 11 KV/ 66 KV INSTALLED AT VARIOUS LOCATION AND CONNECTED ALLIED WORKS UNDER GE WEST PATHANKOT
2024_MES_639854_1
CWE/P-41/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE WEST PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE WEST PATHANKOT
₹50,000
Yes
16 Apr 2024
31 Jan 2024
28 Feb 2024
31 Jan 2024
26 Feb 2024
14 Feb 2024
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in any type of soil for laying of cable, pole foundation,stay,laying of pipe etc., complete all as specified and directed.
Description all as per serial item No. 1 here-in-above but exc 1.5 mtr depth, complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable, complete all as specified and as directed. Note: Punned thickness i.e 18cm will be measured and paid.
M&L for Brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid, complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation of poles filling and mass concrete, complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as poles/coping, stay etc., complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
Supply, laying in replacement & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminium conductor 11 KV (E) grade, cross sectional area 95 Sqmm, 3 core suitable for earth system laid in trenches, complete all as specified and directed. Note: Earth work including excavation, return filling, removal, sand cushioning, brick work for cable protection etc. will be paid and measured separately under respective item of schedule.
Supply, laying in replacement & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminium conductor 11 KV (E) grade, cross sectional area 120 Sqmm, 3 core suitable for earth system laid in trenches, complete all as specified and directed. Note: Earth work including excavation, return filling, removal, sand cushioning, brick work for cable protection etc. will be paid and measured separately under respective item of schedule.
Supply, laying in replacement & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminium conductor 11 KV (E) grade, cross sectional area 185 Sqmm, 3 core suitable for earth system laid in trenches, complete all as specified and directed. Note: Earth work including excavation, return filling, removal, sand cushioning, brick work for cable protection etc. will be paid and measured separately under respective item of schedule.
Supply, laying in replacement & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminium conductor 11 KV (E) grade, cross sectional area 240 Sqmm, 3 core suitable for earth system laid in trenches, complete all as specified and directed. Note: Earth work including excavation return filling, removal, sand cushioning, brick work for cable protection etc. will be paid and measured separately under respective item of schedule
M&L in replacement of rusted GI tubing with light grade GI tubing of size 80mm for cable protection laid in trenches in road/ fixed on PCC foundation or fixed to wall/ Pole, complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11 KV (Earthed) grade cable for out door termination cold shrink type joint, complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sq mm , complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11 KV (Earthed) grade cable for out door termination Cold shrink type joint, complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm , complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11 KV (Earthed) grade cable for in door termination Cold shrink type joint, complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm , complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11 KV (Earthed) grade cable for in door termination Cold shrink type joint, complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 sq mm , complete all as specified and directed.
M&L in replacement for Earthing, complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth plate not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x6mm and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, charcoal and common salt filling, with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 meters,, complete all as per plate No-3, SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on completion.
M&L in replacement for earthing, complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth lead 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision of aggregates with 40mm thick cover of RCC (1;2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25mmx25mmx6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, charcoal and common salt filling, with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 meters,, complete all as per plate No-3, SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on completion.
Supply and fixing in replacement for lightning arresters expulsion type, complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for upto 11000 volts,, complete all as specified and directed.
Supply and fixing Polymeric Pin Type insulator for 11000 volts grade including dismantling of old/ unserviceable insulator, complete all as specified and directed.
Supply and fixing disc type insulator, polymeric Single disc assembly for 11000 volts including dismantling of old/ unserviceable insulator, complete all as specified and directed.
Supply and fixing post type insulator, polymeric for 11000 volts including dismantling of old/ unserviceable insulator, complete all as specified and directed.
Supply and fixing 11 KV Air break switch gang operated (GOD) with dropout fuse, having 12 insulator triple pole mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps including dismantling old / unserviceable air break gang operated switches vertical/ horizontal mounted including insulators and operating mechanism, complete all as specified and directed.
M&L in replacement for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint, complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, complete all as specified and directed. Note: Rate quoted shall be deemed to include necessary Earth work including excavation return filling, removal etc.
Description all as per serial item no. 27 here-in-above but 120 sqmm to 185 sqmm.
Description all as per serial item no. 27 here-in-above but 240 sqmm to 400 sqmm.
Pruning of tree branches and making clear LT/ HT line to the min distance of 1.8 mtrs all around for 2/3/4/5/6 conductor, complete all as specified and directed. Note: (i) Any No. of conductors/wires between two poles will be treated as one span. (ii) Cutting/ trimming to be carried out in patches as per requirement.
M&L for restretching aluminium conductor on existing over head lines including necessary binding of insulator with binding wire, connections of incoming and out going cables, complete all as specified and directed. Note: Unit rate is for stretching/ restringing of three conductor in each span between two pole.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling of old unserviceable cross arms/ bracings/ clamps etc, complete all as specified and directed.
M&L for Stay assembly, complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete will be measured separately) with 20 mm dia rod including dismantling of old UNSV stay from ground and pole, complete all as specified and directed.
M&L in replacement for galvanised stay strand of size 7/3.15mm, complete all as specified and directed.
M&L in replacement for loop type insulator (stay assembly) insulator, vitreous porcelain, white, brown or green Large size, with overall dimensions 90mmx140mm, clearance of hole 25.5mm, complete all as specified and directed.
M&L for prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 erecting in truly position including marking of zebra painting of height 30 cm upto 1.5 mtr including dismantling of old concrete poles any type, complete all as specified and as directed. Note : (i) Excavation, earth work and PCC work shall be measured and paid separately.
M&L in replacement for galvanized steel continuous earth wire 3.15/4 mm dia including stringing for earth conductor on pole including binding etc., complete all as specified and directed .
M&L for ACSR for HT/LT line on PCC/ Steel tubular poles, stretching without kinks and bends including aluminium binding wires of size as per load and dismantling of old/unserviceable ACSR any type, complete all as specified and directed .
M&L in replacement for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size, complete all as specified and directed.
M&L for aluminium Paint for GOD handle, cross arms, clamps, stay assembly all as specified and directed.
M&L in replacement for battery bank with battery constant current, constant voltage (CCCV) battery charging (float or boost) unit to charge 12 volts DC battery bank fitted with digital voltmeter and ammeters, SCR controlled and consisting of double wound transformer (provided with best quality CRGO laminations for high efficiency) an SCR/diode bridge, smoothing choke, capacitors and electric circuit for controlling the voltage and current battery bank placed on rack made out of angle iron frame and solid square bars as requires suitable for floor mounting including 110 Nos batteries of 2 volts each 100 AH. The charger should have indication for mains supply, mode of charging (float or boost), polarity reverse and over load conditions, protection for over load, short circuit, reverse polirty and surge/transient. The charger have alarm on fuse blowing and short circuit. All protections to charger and its meters shall be provided with suitable rating MCB only. The other technical specifications shall be as under:-(i) Input working voltage 180-270 volts. (ii) Normal input 240 V AC, 50 Hz, Single phase.(iii) Float cum boost charging-automatically charges from one state to another state as per battery condition and should give the visual indication for either float or boost based in charging mode.
S&F in replacement trip coil with plunger with working voltage 110/24 Volt volts DC suitable for existing panel, complete all as specified and directed.
S&F in replacement trip coil with plunger with working voltage 220 volts DC suitable for existing panel, complete all as specified and directed.
Supply and fixing of multifunction meter suitable for 11 KV VCB panel, complete all as specified and directed.
M&L for the CTs of ratio 50/25/5-5, with 5 P 10 for protection and class-I accuracy having 15 VA burden including taking out old CTs, complete all as specified and directed.
M&L for the CTs of ratio 100/50/5, with 5 P 10 for protection and class-I accuracy having 15 VA burden including taking out old CTs, complete all as specified and directed.
M&L for the CTs of ratio 200/100/5, with 5 P 10 for protection and class-I accuracy having 15 VA burden including taking out old CTs, complete all as specified and directed.
M&L for the CTs of ratio 400/200/5, with 5 P 10 for protection and class-I accuracy having 15 VA burden including taking out old CTs, complete all as specified and directed.
S&F in replacement of TNC switch 2N+2NC suitable for existing panel, complete all as specified and directed.
Calibration and programming of relay for overloading and earthing fault setting with respect trip setting of 11/66 KV VCB/SF6 panels, complete all as specified and as directed.
Taking down HT switch gear (Vacuum circuit breaker) of capacity 11 KV up to 800 A comprising of following repairs, overhauling, servicing and refixing the same after repairs/ overhauling: a) Tripping off the breaker, lowering the breaker with raising/ lowering handle and pulling out the breaker, complete from the panel along with the trolley for servicing/ inspection/ overhauling b) Servicing/ Inspecting/ checking of automatic safety shutter operation for serviceability and replacement of spares if required. c) Servicing/ Inspecting/ checking of circuit spout and circuit spout connections for RYB phases and replacement of spares if required. d) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. e) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism.
f) Servicing/ Inspecting/ checking of secondary sockets/busbar earthing plugs/earthing sockets and replacement of spares if required. g) Checking, setting and adjustment of lowering and raising operation of the breaker trolley. h) Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly. j) The inspection of HT switch gear shall involve:- (i) Inspection of truck & hoist assembly. (ii) Inspection of tank assembly & barriers. (iii) Inspection of assembly & components of solenoid assembly. (iv) Inspection of assembly & components of dependent mechanism. (v) Inspection of assembly & components of spring box mechanism. (vi) Inspection of motor mechanism spring charge assembly (vii) Inspection of assembly of trip unit & related components Notes: (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge.
M&L for SF6 gas charging upto 110 PSI in 66 KV yard SF6 breakers taking all safety precautions, complete all as specified and directed.
M&L for SF6 gas charging in 11 KV RMU/Breaker installed at different locations by arresting leakage from any other minor defects, complete all as specified and directed. Note for serial item No. 52 & 53: Rate quoted shall be deemed to include rate for arresting leakage also.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
KEWAL SONS
dadwal engineers
dinesh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .