Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹48.8 L+₹69,370.25 (1.44%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹49.4 L+₹1.3 L (2.75%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹50.1 L+₹2.0 L (4.16%)Rejected-Finance OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹50.8 L+₹2.7 L (5.62%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹96,400
Closing Date
16 Aug 2021, 6:00 pmClosed
GE(AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215 (WB)
COMPREHENSIVE REPAIR TO CERTAIN BLDGS OF B/R NATURE IN KV AND 10 AFH AREA INCL REPAIR/REPLACEMENT OF INTERNAL WIRING IN TIPNIS, ARJAN,RS,10 AFH AREA AND REPAIR/MAINT OF INTERNAL WIRING AND CONNECTED WORKS INCLUDING REPLACEMENT OF LIGHT FITTING IN DOM
2021_MES_460585_1
C/8486/21-22/E8
Open Tender
Civil Works
Item Rate
210 days
GE(AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) HASIMARA
₹96,400
Yes
13 Sept 2021
16 Jul 2021
17 Aug 2021
16 Jul 2021
16 Aug 2021
7 Aug 2021
Amount
M & L Water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound including cleaning, picking, sweeping and washing down with water and brushing with neat cement slurry & 3 Kg per Sqm & removing debris to a distance exc 100m & n.exc.250m. (b) 15 mm thick plastering in cement mortar 1:3 mixed with water proofing compound (to be measured seperately) as per manufacturer instructions finished even & smooth. (c) Preparing & cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 300 ml per sqm conforming IS-3384 (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm
Supply only liquid water proofing compound (ISI marked) complete all as specified and directed.
S & F in repair Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F in repair Steel ventilator, fixed type with glazing bar complete all as specified and directed.
S & F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
M & L for Preparation of newly steel & iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S & F in repair mild steel handle for steel window for left/right shutter complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
M & L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound by weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparing newly plastered surfaces of walls etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exe 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but n. exc 2 Sqm each complete all as specified and directed.
S & F 35 mm thick, factory made, glazed/skeleton shutters with second class hard wood,open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc complete as specified and directed . Sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a).
S & F 35 mm thick, 2nd class hardwood, factory made, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides as in cup board shutter complete all as specified and directed.
S & F 15 mm thick, second class hard wood boarding, clean sawn with butt joints and fixed with nail as in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work and fixed as In repairs to replace old and or decayed boarding in patches including cutting out old, piecing, heading joints, etc.complete all as specified and directed.
M & L for 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
M & L for Pressed steel frames 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
M & L for Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
S & F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet, complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side Prelam PVC sheet used instead of plain colour PVC sheets. Stile and rails, feathered at edges for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of both side Prelam PVC sheet used instead of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable Prelam PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
S & F 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
Fixing only 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
Fixing only 75 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed.
S & F 200 mm long, Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 150 mm long, Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 150 mm size, extruded aluminium handles, fabricated type, anodised complete all as specified and directed.
S & F 125 mm size, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties,flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed.
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S & F 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F 3 mm thick, figured glass, pin headed type, in square n.exc 0.5 Sqm in each pane complete all as specified and as directed.
S & F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc including taking down old unserviceable pipe complete all as specified and directed.
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc including taking down old unserviceable pipe complete all as specified and directed.
S & F 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F in repair 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed.
S & F in repair 15 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 142 gms) complete all as specified and directed.
S & F in repair PVC over head tank cover suitable for 500/1000 Litres capacity tank complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks of capapcity exc 250 & n.exc 500 Ltrs and from mouths of circulating pipes, etc. using bleaching powder and washed with water including dismantling and reconnecting and refixing in psoition including writing date of cleaning with white synthetic enamel paint as "CLEANDED ON" complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks of capapcity exc 500 & n.exc 1000 Ltrs and from mouths of circulating pipes, etc. using bleaching powder and washed with water including dismantling and reconnecting and refixing in position including writing date of cleaning with white synthetic enamel paint as "CLEANDED ON" complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm/350mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for 14-16mm thick Granite (of any type) slab machine cut, as in flooring, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M & L for 14-16mm thick Granite (of any type) slab machine cut, as in skirting/dado, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S & F in repairs, Harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers, etc as in curtain rail complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed.
S & F in repairs, 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs, 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repairs, 15 mm bore, Stop valves, cast copper alloy, chromium plated with long shank and cup, concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs, 15mm bore, bib taps of PTMT, any colour high pressure, screwed for iron pipe and fixed (minimum weight 90 gms) complete all as specified and directed.
S & F in repair 15mm, Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms) complete all as specified and directed.
S & F in repair 125 mm Swivel shower rose of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) with Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms) complete all as specified and directed.
S & F in repairs, 32/40mm dia flexible PVC waste pipe for wash basin/sink etc complete all as specified and directed
S & F in repairs, Vitreous China wash hand basin, white, flat back , of size 630 x 450 mm excluding taps but including CP waste coupling, chain, plug & porcelain stopper, bracket complete all as specified and directed.
S & F in repairs, vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed.
S & F in repairs, vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and directed.
S & F in repairs, 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed.
S & F in repairs, 10 litre capacity, PVC valve less syphonic action type,push flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed.
S & F in repair 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
Removal of vegetation/grass etc including Cutting holes into or through brick walls/concrete and removal of small trees/woods etc and making good disturbed surfaces with cement concrete 1:2:4, type B-0 (Using 12.5mm graded aggregate) complete all as specified and directed.
S & F in repairs, stainless steel sinks made of 1 mm thick sheet with plugs, washers and wastes including bedding in ement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Dismantling cast iron, PVC or reinforced concrete drain pipes, etc upto 110mm bore, with fittings jointed in cement mortar and taking out of trenches, floor or walls if required complete all as specified and directed.
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above ground level) and disposal of debris and rubbish to a distance n.exc 100m complete all as directed by the Engr-in-Charge
M & L for 25mm thick plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in floor etc and finished the surface even & rough complete all as specified and directed.
M & L for plain cement concrete 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate) as in benching, coping, bed plate, lintel upto 1.5m span cast in situ including necessary form work complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core, unsheathed, copper conductor cables drawn through and including PVC conduits/casing capping with all fittings and accessories of PVC conduits/casing capping (like Tee, bend etc.) complete fixed to walls/ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point including concealed pressed steel terminal box of required size factory made with top cover of ISI marked plastic laminated sheet of required colour for mounting switches, sockets, regulators etc complete for one light/fan point controlled by one, one way switches including cutting chases and making good the disturbed surface to match with the existing complete all as specified and directed by the Engr-in-Charge.
All as per item No. 89 above but one light/fan point controlled by two way switches, complete all as specified and directed.
All as per item No. 89 above but one buzzer/bell point controlled by one, one way bell push, complete all as specified and directed.
All as per item No. 89 above but one 5 Amps 3/5 pin switch socket outlet on the same board with other switches complete all as specified and directed.
All as per item No. 89 above but one 5 Amps 3/5 pin, Switch socket combination on independent board complete all as specified and directed.
All as per item No. 89 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 5/15 Amps Switch socket combination on Independent board complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core, unsheathed, copper conductor cables drawn through and including stove enamelled steel conduit (medium grade) with all fittings and accessories (like Tee, bend etc.) complete fixed to walls/ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point including concealed pressed steel terminal box of required size factory made with top cover of ISI marked plastic laminated sheet of required colour for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one, one way switches including cutting chases and making good the disturbed surface to match with the existing complete all as specified and directed by the Engr-in-Charge.
All as per item No. 95 above but one 5 Amps 3/5 pin switch socket outlet on the same board with other switches complete all as specified and directed.
All as per item No. 95 above but one 5 Amps 3/5 pin, Switch socket combination on independent board complete all as specified and directed.
All as per item No. 95 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 5/15 Amps Switch socket combination on Independent board complete all as specified and directed.
S & F switch piano, 5 Amp single pole, flush type one way 230 volts complete all as specified and as directed.
S & F Switch piano, flush type, 5 Amps, single pole, two way, 240 Volts complete all as specified and directed.
S & F Bell push, flush type, 5 Amps 230 Volts, complete all as specified and directed.
S & F bell Ding-Dong, AC, 230 volts, single pole complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 6/16 Amps, 240 volts, flush type complete all as specified and directed.
S & F Ceiling rose, 3 terminal, PVC/polycarbonate, isolated body complete all as specified and directed.
S & F Stepped type electronic fan regulator delux rotary type complete all as specified and directed.
S & F lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings including complete all as specified and directed.
M & L Sub main wiring with two runs of 4 sqmm (Nominal area) single core cable FRLS PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC conduits/casing-caping of suitable size, fixed to wall/ceiling etc including 4 sqmm (nominal area) single core, FRLS PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size and taking down old unserviceable sub main wiring complete all as specified and as directed by Engineer-in-charge. (Note : PVC Conduits/Casing-caping, two run cables and one run of earth wire will be measured as one length.)
M & L for Sub main wiring with two runs of 6 sqmm (Nominal area) single core cable FRLS PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through and including PVC conduits/casing-caping of suitable size, fixed to wall/ceiling etc including 6 sqmm (nominal area) single core, FRLS PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size and taking down old unserviceable sub main wiring complete all as specified and as directed by Engineer-in-charge. (Note : PVC Conduits/Casing-caping, two run cables and one run of earth wire will be measured as one length.)
S & F Factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 4 way, 240 Volts suitable for housing MCBs complete all as specified and directed. (Make : Legrand Cat No. 5076 10 or equivalent model as approved)
S & F Factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts suitable for housing MCBs complete all as specified and directed. (Make : Legrand, Cat No. 5076 11 or equivalent model as approved)
S & F Factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 12 way, 240 Volts suitable for housing MCBs complete all as specified and directed. (Make : Legrand, Cat No. 5076 12 or equivalent model as approved)
S & F factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, TPN, 4 way, 415 Volts suitable for fixing MCBs complete all as specified and directed. (Make : Legrand Cat No. 6077 15 or equivalent model as approved)
S&F VTPN prewired distribution board TPN-DPX 125 MCCB including one No MCCB 125 Amps as incomer and suitable ELCB'S/ RCBO/ SP/TP /MCBs as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 4 way complete all as specified and as directed. (Make: Legrand IP-54-IK-09 Cat No. 5077 35 or equivalent in Schneider/ABB) (Note : MCB SPN/SP/TP shall be measured & paid seperately under respective items of schedule)
Supply & fixing MCB Triple Pole and Neutral (TPN) of capacity 63 Amps, 415 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position complete all as specified and directed.(Make Cat No 4086 65 to 4086 70 of legrand or equivalent)
Supply & fixing MCB Single Pole and Neutral (SPN) of capacity 40 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position complete all as specified and directed.(Make Cat No 4086 18 to 4086 20 of legrand or equivalent)
Supply & fixing MCB Single Pole and Neutral (SPN) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position complete all as specified and directed.(Make : legrand Cat No. 4086 09 to 4086 17 or equivalent)
Supply & fixing MCB Single Pole SP of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position complete all as specified and directed.(Make Cat No 4085 87 to 4085 95 of legrand or equivalent)
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (light grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
S&F in replacement Recessed mounted LED light fittings, 36W (Size 2' x 2'), white / warm white colour (4500 K to 6500 K) ultra modern LED edge0lit luminaire suitable for armstrong/grip/POP ceiling complete with seperate electronic driver and high brightness LEDs including LED lamp and connecting cable 3 core 2.5 sqmm up to nearest point complete all as specified and directed.(Make: Havells cat part No ENDURASLIMPROPLUS2X2PLR26WLED857MOD or equivalent make of Bajaj / Philips / Crompton).
S&F in replacement Recessed mounted LED light fittings, 30W (Size 4' x 1'), white / warm white colour (4500 K to 6500 K) ultra modern LED edge0lit luminaire suitable for armstrong/grip/POP ceiling complete with seperate electronic driver and high brightness LEDs including LED lamp and connecting cable 3 core 2.5 sqmm up to nearest point complete all as specified and directed.(Make : Havells cat part No PLUTONEO4X1PLR30WLED840S or equivalent make of Bajaj / Philips / Crompton).
S&F in replacement round type recessed mounting LED luminaire 18/20 Watt including making arrangment in ceiling as per the size of fittings and connecting twin core cable up to nearest point complete with Inbuit/separate electronic driver & high brightness LEDs Natural white colour complete all as specifed & directed. (Make : Havells cat part No EDGEPRORDDLR18WLED857S or equivalent make of Bajaj / Crompton / Philips)
S&F 30W or higher LED wall washers light round shaped luminaire recess mounted, tilted 70° outwards and swivels 360° suitable for armstrong/grid ceiling including connecting three core copper cable up to ceiling rose complete with suitable electronic driver & high brightness LEDs white colour complete all as specified & directed.(Make :- Havells cat part No SPARKLEPROSNOOTDLR30W830MOD38DWHTNEEM or Bajaj cat part No BXDR NW or Philips cat part No ST271T LED40/830 PSU-E NB 1C BK or Wipro cat part No LD57-381-024-40-32)
S & F wall mounted slim LED batten, with extruded aluminium housing, with integrated electronic LED driver with LED lamp, 10 Watt and connecting up complete all as specified and directed. (Make : Havells Cat No. LUMILINEPLUSBS10WLED865SPCSS or equivalent model of Bajaj / Philips / Crompton)
S & F wall mounted slim LED batten, with extruded aluminium housing, with integrated electronic LED driver with LED lamp, 20 Watt and connecting up complete all as specified and directed. (Make : Havells Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivalent model of Bajaj / Philips / Crompton)
S & F in repair LED tube, T8, 20W, Ultra bright LED polycarbonate Tubelight rod with very high efficiency and G13 lamp holders, environment friendly with high luminous efficiency complete all as specified and directed. (Make : Havells Cat No. PHOTONULTRA1213T8SSTL20WLED865SPC or equivalent model of Bajaj / Philips / Crompton)
S & F new generation enargy saving LED bulkhead fittings, 10W made up of aluminium PDC housing with opal diffuser with LED lamp, 10 Watt and connecting up complete all as specified and directed. (Make : Havells Cat No. HEXAFT10WLED857SSYMBOPC or equivalent model of Bajaj / Crompton / Philips)
S & F new generation enargy saving 18W LED PL-L tube rod ultra bright with very high efficacy suitable in existing 2G11 lamp holders complete all as specified and directed. (Make : Havells cat part No PHOTONULTRA PLL419TL18WLED865SPC or equivalent model of Bajaj / Crompton/ Philips)
S & F in repair Capacitor for ceiling fan of capacity 2.5 mfd/4mfd (PVC body) + 5%, 220 volts, 50 Hz conforming to IS - 1709 AAPHS, temperature Max 85 degree centrigate complete all as specified and directed. (Make: NICCO, SIEMENS, EPCOS, Universal & TIBCON)
S & F wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED lamp, 18 Watt and connecting up complete all as specified and directed. (Make : Surya Cat No. SLE BT 20 and equivalent model of make as specified in list of manufacturer).
S & F in repair wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED lamp, 18 Watt and connecting up complete all as specified and directed. (Make : Surya Cat No. SLE BT 20 and equivalent model of make as specified in list of manufacturer).
S & F wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED lamp, 9 Watt and connecting up complete all as specified and directed. (Make : Surya Cat No. SLE BT 10 and equivalent model of make as specified in list of manufacturer).
S & F in repair wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED lamp, 9 Watt and connecting up complete all as specified and directed. (Make : Surya Cat No. SLE BT 10 and equivalent model of make as specified in list of manufacturer).
S & F in repairs Modular switch 1 way 6A, 1 Module 250 volts complete all as specified and as directed.
S & F in repairs Modular switch 1 way 16A, 1 Module 250 volts complete all as specified and as directed.
S & F in repair modular Bell push 6A, 1 module complete all as specified and directed.
S & F in repairs modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed
S & F in repairs modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed
S & F in repairs modular Fan step regulator, 120W - 2 module complete all as specified and directed
S & F in repair modular White cover plate with frame, 2 module complete all as specified and directed
S & F in repair modular White cover plate with frame, 4 module complete all as specified and directed
S & F in repairs modular White cover plate with frame, 8 module complete all as specified and directed
Taking down from any position and Dismantling ceiling fan (any size/sweep/make), repair the same by cleaning, overhauling, necessary lathe work etc and taking out existing burnt out winding wire of motor and rewinding the same after proper cleaning with super enamelled copper wires as per existing gauge and turn to achieve the desired RPM, necessary insulating materials, insulating varnishing, cleaning and reassembling the ceiling fan after replacement of unserviceable minor parts such as split pin, lock nuts, rubber packing, clamp of condenser, blade nuts, rubber reel insulator, nuts bolts, plastic fan canopy etc as required for smooth functioning of the fan and Replacement of unserviceable major parts like capacitor, bearing, bush etc and testing complete on completion and re-fixing the fan in existing position including provn of twin twisted flexible copper stranded conductor wire of size 23/0.0076 Sqmm of required length complete as directed by the Engineer-in-Charge (Note : (a) Replacement of unserviceable major parts like capacitor, bearing, bush etc shall be measured and paid separately as "Supply only" under respective items of this Schedule. (b) Unit quoted rate shall deemed to be inclusive of transportation of fan to workshop from site of work and back)
All as per item No 143 above but for exhaust fan upto 600mm sweep complete all as specified and directed
Supply only Capacitor of capacity 2.5 mfd, 220 Volts complete all as specified and directed.
Supply only Gun metal bush of suitable size of existing motor shaft for ceiling fan complete all as directed. (Make:- Orient, Usha, Ganesh, Khaitan, MIE)
Supply only Ball bearing No 6200/6201/6202/6203 complete all as directed (Make : TATA/SKF/NBC/HCH).
Comprehensive repair/maintenance of storage type electric heater (geyser) vertical/horizontal type of capacity upto 50 ltrs comprising of the following works complete all as directed by the Engr-in-Charge:- (a) Inspection, taking down or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the entire satisfection of Engr-in-Charge (b) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required. (c) Inspect overflaw and vent pipes and remove blockages (if any) (d) Checking and rectify earth continuity of the electrical circuits of the geyser and power points (e) Check, maintain and re-fixing thermostat and re-adjust (f) Visual examination of of fusible plugs for its serviceability (g) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution (h) Checking of indicator lamp for its serviceability (j) Re-assembling the geyser, re-installed and testing complete (Note: (i) Spare parts/components of geysers shall be measured and paid seperately as "supply only" under respective items here-in-below. (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt.)
Supply only heating element, 2KW capapcity, AC 230 volts, pressed/screw/ triangular/ ceramic type, ISI marked complete all as specified and directed.
Supply only heating element, 1.5KW capapcity, AC 230 volts, pressed/ screw/ triangular/ ceramic type, ISI marked complete all as specified and directed.
Supply only thermostate element adjustable type, 11/20 Amp 250 Volt ISI Marked complete all as directed
Supply only thermostate element adjustable type, 7/15 Amp 250 Volt ISI Marked complete all as directed
Supply only hot and cold flexible pipe, high pressure with both end brass adopter 18" long ISI marked complete all as directed.
Supply only copper connection tubes for inlet/outlet connection PVC washer, benjo nuts and bolts etc. 450 mm long 3/8'' dia standard gauge complete all as directed.
Supply only porcelain heating element ceramic type,for 2.0KW geyser , AC 230 volts, complete all as specified and directed.
S & F in repair energy saving LED bulkhead fittings, 10W with LED lamp and connecting up complete all as specified and directed. (Make : Crompton Cat No. LBHN-10-CDL/Bajaj Cat No. BIBWP 10W LED and equivalent model of make as specified in list of manufacturer).
Supply only pressure plate suitable for fixing thermostat and heating element with 6/7/8 Nos of holes complete all as specified and directed. Note: An amount of Rs. 95260.00 on account of credit schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S ASHOK ENTERPRISE
M/S RATHIN ENTERPRISES
M/S BIJAY KUMAR SHIVA
SHRI PARTHA DUTTA
MAA TARA TRADING
M/S ANIL KUMAR BAUL
M/S SARDAR MAL NAHATA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .