Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹319.4 CrAdmitted-Finance | ₹319.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹330.5 CrAdmitted-Finance NCC HOUSE MADHAPUR HYDERABAD 500081 TELANGANA INDIA TELEPHONE 040 23268730 | ₹330.5 Cr | L2 | Admitted-Finance |
| 3 | L3₹348.1 CrAdmitted-Finance | ₹348.1 Cr | L3 | Admitted-Finance |
| 4 | L4₹350.3 CrAdmitted-Finance CRYSTAL TOWER 4TH FLOOR TELIBANDHA RAIPUR | RAIPUR | RAIPUR | CHHATTISGARH | ₹350.3 Cr | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s. Ashoka Buildcon Ltd L3 | SALASAR TECHNO ENGINEERING LIMITED L1 | NCC LIMITED L2 | LARSEN AND TOUBRO LIMITED L4 |
|---|---|---|---|---|---|---|---|
| 1.00Armoured LT cabling in high loss area (LT line on 3.5Cx 50 sq.mm armoured cable) | |||||||
| 2.00 | 8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification | 2,006 | Nos | 75,48,357.34 ₹89.1 L | 1,04,79,544.6 ₹1.2 Cr | 87,61,265.18 ₹1.0 Cr | 76,44,785.76 ₹90.2 L |
| 3.00 | Stone Pad (300x300x75mm) | 2,006 | Nos | 1,76,287.28 ₹2.1 L | 1,46,839.2 ₹1.7 L | 1,91,412.52 ₹2.3 L | 1,83,709.48 ₹2.2 L |
| 4.00 | LT Shakle Insulator 100x115 mm | 35,113 | Nos | 10,75,160.06 ₹12.7 L | 7,40,884.3 ₹8.7 L | 20,93,085.93 ₹24.7 L | 7,44,395.6 ₹8.8 L |
| 5.00 | D-Straps with Nuts and Bolts (Shackle Insulators) | 35,113 | Nos | 28,24,489.72 ₹33.3 L | 35,67,480.8 ₹42.1 L | 60,67,877.53 ₹71.6 L | 20,55,866.15 ₹24.3 L |
| 6.00 | Supply of LT XLPE armoured 3.5x50 Sq. mm. Cable | 263.35 | Km. | 8,93,82,056.57 ₹10.5 Cr | 6,14,44,848.34 ₹7.3 Cr | 6,21,34,680.49 ₹7.3 Cr | 6,94,95,521.04 ₹8.2 Cr |
| 7.00 | Erection of LT XLPE armoured 3.5x50 Sq. mm. Cable | 250.81 | ckm | - | - | - | - |
| 8.00 | Mid Span Jointing Sleeves (50 sq. mm) | 2,006 | Nos | 2,65,714.76 ₹3.1 L | 1,59,276.4 ₹1.9 L | 2,75,363.62 ₹3.2 L | 3,74,399.84 ₹4.4 L |
| 9.00 | Insulating Piercing Connector (16-150 sq.mm) | 11,036 | Nos | 9,55,717.6 ₹11.3 L | 11,80,852 ₹13.9 L | 11,18,277.88 ₹13.2 L | 7,45,592.16 ₹8.8 L |
| 10.00 | Insulation mastic tape (2inc X 10 feet). | 5,769 | Nos | 13,87,675.26 ₹16.4 L | 12,72,641.4 ₹15.0 L | 11,69,203.23 ₹13.8 L | 8,42,331.69 ₹9.9 L |
Tender Value
₹346.6 Cr
EMD Value
₹5 Cr
Closing Date
21 Nov 2022, 4:00 pmClosed
Superintending Engineer (MM 2)
MD Office PVVNL Meerut
DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE WORK FOR LOSS REDUCTION AT DISTRICTMEERUT AND BAGHPAT IN PsVVNL UNDER REVAMPED REFORMS-BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME
2022_PVVNL_743763_1
PVVNL-MT/MM/RDSS/85/22-23
Open Tender
Electrical Works
730 days
PVVNL Meerut
Please refer tender documents.
2 documents required · 2 mandatory
₹29,500
S E (HQ) PVVNL
₹5 Cr
MD Office PVVNL Meerut through Physical and VC
12 Dec 2022
2 Nov 2022
22 Nov 2022
2 Nov 2022
21 Nov 2022
12 Nov 2022
5 Nov 2022
Armoured LT cabling in high loss area (LT line on 3.5Cx 50 sq.mm armoured cable)
8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
Stone Pad (300x300x75mm)
LT Shakle Insulator 100x115 mm
D-Straps with Nuts and Bolts (Shackle Insulators)
Supply of LT XLPE armoured 3.5x50 Sq. mm. Cable
Erection of LT XLPE armoured 3.5x50 Sq. mm. Cable
Mid Span Jointing Sleeves (50 sq. mm)
Insulating Piercing Connector (16-150 sq.mm)
Insulation mastic tape (2inc X 10 feet).
Three Phase SMC Distribution Box with clamps and suitable lock and key arrangment
Single of Phase SMC Distribution Box with clamps and suitable lock and key arrangment
1x25 mm2 Armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Angle for vertical Arm (Type-A )as per approved drawing & TS
Angle for vertical Arm (Type-B) as per approved drawing &TS
Top clamp for Vertical arm( Type-A) as per TS
Top clamp for Vertical arm( Type-B) As per TS
Bottom clamp for vertical arm (Type-A) As per TS
Bottom clamp for vertical arm (Type-B) As per TS
Dismantling of existing overhead line and transportation of materials to PVVNL Store.
Concreting Works of Poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips (8.5 Meter - PCC pole) as per approved Drawing and TS
Conversion of existing Service Cable to New Armoured Service cable 2Cx 6 sq.mm with all required accessories like lugs etc. (Complete Work in all respect) and Removing and shifting of Existing Material to client store
PVC 2C x 6 sq.mm. Armoured Cable for Service Connection
Conversion of existing Service Cable to New Armoured Service cable 4Cx 16 sq.mm with all required accessories like lugs etc. (Complete Work in all respect) and Removing and shifting of Existing Material to client store
PVC 4C x 16 sq.mm. Armoured Cable for Service Connection
Replacement of bare conductors/Damaged A.B. Cable with LT AB Cables (3x50+1x35+1x16) sq.mm.
8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
Stone Pad (300x300x75mm)
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Dead End clamp (Insulated)
Suspension clamps (Insulated)
Pole Clamps with I-Hook & nut & bolts for laying ABC
Holding clamp for round pole with with I-Hook & nut and bolt
Insulating Piercing Connector (16-150 sq.mm)
SMC LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections
Supply of LT ABC of 3x50+1x35+1x16 sq. mm
Erection of LT ABC of 3x50+1x35+1x16 sq. mm
1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
End cap for LT AB cable
PG Clamps
Concreting of PCC Pole/Support as per TS
Dismantling of existing overhead line and transportation of materials to PVVNL Store.
Replacement of bare conductors/Damaged A.B. Cable with LT AB Cables (3x95+1x70+1x16) sq.mm.
8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
Stone Pad (300x300x75mm)
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Dead End clamp (Insulated)
Suspension clamps (Insulated)
Pole Clamps with I-Hook & nut & bolts for laying ABC
Holding clamp for round pole with with I-Hook & nut and bolt
Insulating Piercing Connector (16-150 sq.mm)
SMC LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections
Supply of LT ABC of 3x95+1x70+1x16 sq. mm
Erection of LT ABC of 3x95+1x70+1x16 sq. mm
1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
End cap for LT AB cable
PG Clamps
Concreting of PCC Pole/Support as per TS
Dismantling of existing overhead line and transportation of materials to PVVNL Store.
Replacement of bare conductors/Damaged A.B. Cable with LT AB Cables (3x120+1x95+1x16) sq.mm.
8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
Stone Pad (300x300x75mm)
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Dead End clamp (Insulated)
Suspension clamps (Insulated)
Pole Clamps with I-Hook & nut & bolts for laying ABC
Holding clamp for round pole with with I-Hook & nut and bolt
Insulating Piercing Connector (16-150 sq.mm)
SMC LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections
Supply of LT ABC of 3x120+1x95+1x16 sq. mm
Erection of LT ABC of 3x120+1x95+1x16 sq. mm
1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
End cap for LT AB cable
PG Clamps
Concreting of PCC Pole/Support as per TS
Dismantling of existing overhead line and transportation of materials to PVVNL Store.
Feeder bifurcation (11 KV line)
11kV New Line on 11 Mtr. ST Pole with ACSR DOG Conductor (Feeder bifurcation 11 KV Line)
11 Mtr. Long Steel Tubular pole 410 SP 55
11 KV Polymer Disc Insulator B&S type 45 KN
Disc Fitting B&S type 45 KN
11 KV Composite Polymer Pin Insulator with Nut and washers as per TS
11kV MS Danger Board with clamp, bolts & nuts
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Supply of ACSR Dog Conductor
Erection of ACSR Dog Conductor
P.G. Clamp for ACSR Dog
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Aluminium Jointing Sleeves
G.I. Barbed Wire
GI Wire 6 SWG
GI Wire 8 SWG
GI Wire 16 SWG
Eye Bolt
Turn Buckle
Red Oxide Paint
Aluminium Paint
11kV 'E' Bracket with N&B
11kV `F' Bracket with N&B
GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers
GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers
GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer
GI Top Channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers
V-Type Cross arm for 11KV Line, 100x50x6 mm, GI
Cross arm holding Clamp with nuts & bolts
Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc.
Concreting of STP Pole/Support as per TS
11kV New Line on 8.5 Mtr. PCC Pole with ACSR DOG Conductor
8.5 Mtr.long ,180Kg . PCC Poles as per Approved Drawing and Technical specification
Stone Pad (300x300x75mm)
V-Type Cross arm for 11KV Line, 100x50x6 mm, GI
Cross arm holding Clamp with nuts & bolts
11 KV Polymer Disc Insulator B&S type 45 KN
Disc Fitting B&S type 45 KN
11 KV Composite Polymer Pin Insulator with Nut and washers as per TS
11kV MS Danger Board with clamp, bolts & nuts
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Supply of ACSR Dog Conductor
Erection of ACSR Dog Conductor
P.G. Clamp for ACSR Dog
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Aluminium Jointing Sleeves
G.I. Barbed Wire
GI Wire 6 SWG
GI Wire 8 SWG
GI Wire 16 SWG
Eye Bolt
Turn Buckle
11kV 'E' Bracket with N&B
11kV `F' Bracket with N&B
GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer
GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers
GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers
Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc.
Concreting of PCC Pole/Support as per TS
11 KV Railway Crossing
11 Mtr. Long Steel Tubular pole 410 SP 55
11kV 3x185 mm2 XLPE Cable
GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers
GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers
Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size
HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing)
G.I. Pipe 6" dia .
11 KV Polymer Disc Insulator B&S type 45 KN
Disc Fitting B&S type 45 KN
P.G. Clamp for ACSR Dog
11kV MS Danger Board with clamp, bolts & nuts
G.I. Barbed Wire
Aluminium Paint
Red Oxide Paint
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Concreting of STP Pole/Support as per TS
Railway Crossing Documentation, Land and Approval Fee etc. (Payment shall be done as per actual)
Digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 KV & 11 KV XLPE cables
NHAI/State Highway Crossing
11 Mtr. Long Steel Tubular pole 410 SP 55
11kV 3x185 mm2 XLPE Cable
Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size
HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing)
G.I. Pipe 6" dia .
GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers
GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers
11 KV Polymer Disc Insulator B&S type 45 KN
Disc Fitting B&S type 45 KN
P.G. Clamp for ACSR Dog/Raccoon
11kV MS Danger Board with clamp, bolts & nuts
G.I. Barbed Wire
Aluminium Paint
Red Oxide Paint
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Concreting of STP Pole/Support as per TS
NHAI/State highway crossing documentation, land charges and approval fee etc. (Payment shall be done as per actual)
Road Restoration (Foot Path )charges
Digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 KV & 11 KV XLPE cables
Augumentation/ Reconductoring of 33 KV overhead line with Dog conductor
PCC Pole, 9.0 Mtr. Long
11 Mtr. Long Steel Tubular pole 410 SP 55
Stone Pad (300x300x75mm)
Supply of ACSR Dog Conductor
Erection of ACSR Dog Conductor
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire asper TS
Aluminium Paint
Red Oxide Paint
33kV MS Danger board with clamp and N&B
G.I. Barbed Wire
33kV 'F' Bracket with N&B
V-Type Cross Arm for 33KV line 100x50x6 mm, GI
Cross arm holding Clamp with nuts & bolts
33 KV Composite Polymer Pin Insulator with Nut and washers
33 KV Polymer Disc Insulator B&S type 70 KN
Disc Fitting B&S type 70 KN
33 KV Complete Stay Set with Clamp & Nut and Bolt & 33KV Guy Insulator as per approved drawing and TS
Stay Wire 7/8 SWG
Dismantling of existing overhead line and transportation of materials to PVVNL Store.
Concreting of PCC Pole/Support as per TS
Concreting of STP Pole/Support as per TS
Augmentation/Reconductoring of 11kV overhead Line with ACSR DOG Conductor
PCC Pole, 8.5 Mtr. Long
11 Mtr. Long Steel Tubular pole 410 SP 55
Stone Pad (300x300x75mm)
V-Type Cross arm for 11KV Line, 100x50x6 mm, GI
Cross arm holding Clamp with nuts & bolts
11kV `F' Bracket with N&B
11 KV Polymer Disc Insulator B&S type 45 KN
Disc Fitting B&S type 45 KN
11 KV Composite Polymer Pin Insulator with Nut and washers as per TS
Supply of ACSR Dog Conductor
Erection of ACSR Dog Conductor
11kV MS Danger Board with clamp, bolts & nuts
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
P.G. Clamp for ACSR Dog
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire asper TS
Aluminium Jointing Sleeves
G.I. Barbed Wire
Red Oxide Paint
Aluminium Paint
Guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc.
GI Wire 6 SWG
GI Wire 8 SWG
GI Wire 16 SWG
Eye Bolt
Turn Buckle
Dismantling of existing overhead line and transportation of materials to PVVNL Store.
Concreting of PCC Pole/Support as per TS
Concreting of STP Pole/Support as per TS
11 KV Agriculture feeder segregation & feeder splitting due to overloading
11kV New Line on 8.5 Mtr. PCC Pole with ACSR Weasel Conductor
PCC Pole, 8.5 Mtr. Long
Stone Pad (300x300x75mm)
V-Type Cross arm for 11KV Line, 65x65x6 mm, GI Angle
Cross arm holding Clamp with nuts & bolts
11KV `F' Bracket with N&B
Supply of ACSR Weasel Conductor
Erection of ACSR Weasel Conductor
11kV Polymer Disc Insulator T&C type 45 KN
Disc Fittings T&C type 45 KN
11 KV Composite Polymer Pin Insulator with Nut and washers as per TS
11KV MS Danger Board with clamp, bolts & nuts
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
PG Clamps
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Aluminium Jointing Sleeves
G.I. Barbed Wire
GI Wire 6 SWG
GI Wire 8 SWG
GI Wire 16 SWG
Eye Bolt
Turn Buckle
11kV 'E' Bracket with N&B
GI Top Channel 100x50x2240 mm. with Clamp and N&B and waashers
GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers
GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer
GI Top Channel 100x50x6, 1525 mm long ,with clamp, nut,bolt and washer
Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc.
Concreting of PCC Pole/Support as per TS
New LT Line on ACSR Weasel Conductor on 8.5 Mtr. PCC Pole
PCC Pole, 8.5 Mtr. Long
Stone Pad (300x300x75mm)
LT clamp with nut and bolt for PCC pole
LT Shakle Insulator 100x115 mm With Nut and Bolt
Supply of ACSR Weasel Conductor
Erection of ACSR Weasel Conductor
Aluminium Jointing Sleeves
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Concreting of PCC Pole/Support as per TS
Construction of new 100 KVA, 11/0.433kV Distribution Transformer S/S
11/0.44 kV 100 KVA Transformer (Level-I) as per specified in T.S.
PCC Pole, 8.5 Mtr. Long
Stone Pad (300x300x75mm)
GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers
GI Channel 100x50x2240mm (For TPMO,LA and Fuse set)
Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers
GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base
GI Channel 125x65x6, 1300mm (Tee-off) with clamp & Nut bolts
11kV Polymer Disc Insulator T&C type 45 KN
Disc Fittings T&C type 45 KN
11 KV Composite Polymer Pin Insulator with Nut and washers as per TS
11kV TPMO complete set
11kV DO Fuse Set (3 Phase)
11kV Lightening Arrestor
G.I. Barbed Wire
11kV MS Danger Board with clamp, bolts & nuts
SMC Distribution box as per technical specifications for 3 Ph 100 KVA DTR
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) as per TS
Aluminium L-Piece of size 400x60x10 mm for LT bushing rod of transformer
LT PVC Cable 3.5x150/70 Sq.mm.
ACSR Weasel Conductor
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
GI Strip 25x3 mm
GI Angle 100x50x2028mm (For Distribution box))
Al. Crimping lugs 150 sq.mm.
Al. Crimping lugs 70 sq.mm.
Extra for Al. tape , binding wire, jointing sleeves, PG clamps etc.
Concreting of PCC Pole/Support as per TS
Construction of new 63 KVA, 11/0.433kV Distribution Transformer S/S
11/0.44 kV 63 KVA Transformer (Level-I) as per specified in T.S.
PCC Pole, 8.5 Mtr. Long
Stone Pad (300x300x75mm)
GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers
GI Channel 100x50x2240 mm (For TPMO,LA and Fuse set)
Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers
GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base
GI Channel 125x65x6, 1300mm (Tee-off) with clamp & Nut bolts
11kV Polymer Disc Insulator T&C type 45 KN
Disc Fittings T&C type 45 KN
11 KV Composite Polymer Pin Insulator with Nut and washers as per TS
11kV TPMO complete set
11kV DO Fuse Set (3 Phase)
11kV Lightening Arrestor
G.I. Barbed Wire
11kV MS Danger Board with clamp, bolts & nuts
SMC Distribution box as per technical specifications for 3 Ph 63 KVA DTR
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Chemical Pipe Earthing (80 mm dia, 3 m long Pipe)
Aluminium L-Piece of size 400x60x10 mm for LT bushing rod of transformer
LT PVC Cable 3.5x70/35 Sq.mm.
ACSR Weasel Conductor
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
GI Strip 25x3 mm
GI Angle 100x50x2028mm (For Distribution box))
Al. Crimping lugs 70 sq.mm.
Al. Crimping lugs 35 sq.mm.
Extra for Al. tape , binding wire, jointing sleeves, PG clamps etc.
Concreting of PCC Pole/Support as per TS
Construction of new 25 KVA, 11/0.433kV Distribution Transformer S/S
11/0.44 kV 25 KVA Transformer (Level-I) as per specified in T.S.
PCC Pole, 8.5 Mtr. Long
Stone Pad (300x300x75mm)
GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers
GI Channel 100x50x2240mm (For TPMO,LA and Fuse set)
Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers
GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base
GI Channel 125x65x6, 1300mm (Tee-off) with clamp & Nut bolts
11kV Polymer Disc Insulator T&C type 45 KN
Disc Fittings T&C type 45 KN
11 KV Composite Polymer Pin Insulator with Nut and washers
11kV TPMO complete set
11kV DO Fuse Set (3 Phase)
11kV Lightening Arrestor
G.I. Barbed Wire
11kV MS Danger Board with clamp, bolts & nuts
SMC Distribution box as per technical specifications for 3 Ph 25 KVA DTR
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) as per TS
Aluminium L-Piece of size 400x60x10 mm for LT bushing rod of transformer
LT XLPE insulated unarmoured 4x25 Sq. mm. Cable
ACSR Weasel Conductor
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
GI Strip 25x3 mm
GI Angle 100x50x2028mm (For Distribution box))
Al. Crimping lugs 25 sq.mm.
Extra for Al. tape , binding wire, jointing sleeves, PG clamps etc.
Concreting of PCC Pole/Support as per TS
Installation of 11 KV Outgoing VCB for Feeder Segreration
11KV Outgoing CTR 400/200/5A 350 MVA
11kV 3x185 mm2 XLPE Cable
Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size
Heat Shrinkable indoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size
11 Mtr. Long Steel Tubular pole 410 SP 55
GI Top Channel 100x50x2240 mm. with Clamp and N&B
11 KV Polymer Disc Insulator B&S type 70 KN
Disc Fitting B&S type 70 KN
11 KV Composite Polymer Pin Insulator with Nut and washers
P.G. Clamp for ACSR Dog/Raccoon
11kV 'E' Bracket with N&B
11kV MS Danger Board with clamp, bolts & nuts
11kV Lightening Arrestor
G.I. Barbed Wire
Aluminium Paint
Red Oxide Paint
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
GI Strip 50x6 mm
G.I. Pipe 6" dia .
Laying of 11 KV Cable including cost of Sand & Bricks
Concreting of STP Pole/Support as per TS
Control Room Extension
Extension of existing substation control room building,Control Room size 6x6 mtrs.( as per annexure attached in tender documents.)
11 KV Railway Crossing
11 Mtr. Long Steel Tubular pole 410 SP 55
11kV 3x185 mm2 XLPE Cable
GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers
GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers
Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size
HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing)
G.I. Pipe 6" dia .
11 KV Polymer Disc Insulator B&S type 45 KN
Disc Fitting B&S type 45 KN
P.G. Clamp for ACSR Dog/Raccoon
11kV MS Danger Board with clamp, bolts & nuts
G.I. Barbed Wire
Aluminium Paint
Red Oxide Paint
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Concreting of Pole/Support as per TS
Railway Crossing Documentation, Land and Approval Fee etc. (Payment shall be done as per actual)
Digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 KV & 11 KV XLPE cables
NHAI/State Highway Crossing
11 Mtr. Long Steel Tubular pole 410 SP 55
11kV 3x185 mm2 XLPE Cable
Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size
HDPE Pipe for Cable laying (Pipe to be laid by HDD Method) (For Railway Crossing /Road Crossing)
G.I. Pipe 6" dia .
GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers
GI Angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, Nut, bolt and washers
11 KV Polymer Disc Insulator B&S type 45 KN
Disc Fitting B&S type 45 KN
P.G. Clamp for ACSR Dog/Raccoon
11kV MS Danger Board with clamp, bolts & nuts
G.I. Barbed Wire
Aluminium Paint
Red Oxide Paint
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Concreting of Pole/Support as per TS
NHAI/State highway crossing documentation, land charges and approval fee etc. (Payment shall be done as per actual)
Road Restoration (Foot Path )charges
Digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 KV & 11 KV XLPE cables
Requirement of Extra AB Cable for New additional Ckt at DTs
Construction of New LT Line on (3x50 + 1x35 +1x16)sq. mm LT ABC Cable
PCC Pole, 8.5 Mtr. Long
11 Mtr. Long Steel Tubular pole 410 SP 55
Stone Pad (300x300x75mm)
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Dead End clamp (Insulated)
Suspension clamps (Insulated)
Pole Clamps with I-Hook & nut & bolts for laying ABC
Insulating Piercing Connector (16-150 sq.mm)
SMC LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections
Supply of LT ABC of 3x50+1x35+1x16 sq. mm
Erection of LT ABC of 3x50+1x35+1x16 sq. mm
1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
End cap for LT AB cable
PG Clamps
Concreting of PCC Pole/Support as per TS
Concreting of STP Pole/Support as per TS
Construction of New LT line on (3x95 + 1x70 +1x16)sq. mm LT ABC Cable
PCC Pole, 8.5 Mtr. Long
11 Mtr. Long Steel Tubular pole 410 SP 55
Stone Pad (300x300x75mm)
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Dead End clamp (Insulated)
Suspension clamps (Insulated)
Pole Clamps with I-Hook & nut & bolts for laying ABC
Insulating Piercing Connector (16-150 sq.mm)
SMC LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections
LT ABC of 3x95+1x70+1x16 sq. mm
LT ABC of 3x95+1x70+1x16 sq. mm
1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
End cap for LT AB cable
PG Clamps
Concreting of PCC Pole/Support as per TS
Concreting of STP Pole/Support as per TS
Construction of New LT line on (3x120 + 1x95 +1x16)sq. mm LT ABC Cable
PCC Pole, 8.5 Mtr. Long
11 Mtr. Long Steel Tubular pole 410 SP 55
Stone Pad (300x300x75mm)
Earthing coil (coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm GI wire) with 6 SWG GI Wire as per TS
Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle -1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS
Stay Wire 7/10 SWG
Dead End clamp (Insulated)
Suspension clamps (Insulated)
Pole Clamps with I-Hook & nut & bolts for laying ABC
Insulating Piercing Connector (16-150 sq.mm)
SMC LT distribution boxes/kiosk, 3 phase on the LT Poles including all clamps & material required for mounting connections
Supply of LT ABC of 3x120+1x95+1x16 sq. mm
Erection of LT ABC of 3x120+1x95+1x16 sq. mm
1x25 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes.
End cap for LT AB cable
PG Clamps
Concreting of PCC Pole/Support as per TS
Concreting of STP Pole/Support as per TS
Additional items that may be required for completion of work
3x120 sq. mm 11 kV AB Cable
11kV Polymer Disc Insulator with Fitting for 11 KV ABC
11kV Polymer Disc Insulators with I-Hook
Erection & concreting of Extra Stud Pole complete with clamps,
GI Channel 100 x 50 x 3200 mm unit with mounting clamps, Nut, Bolt and washers
GI Angle 50 x 50 x 6 mm, 3200 mm long with 2 Nos. clamps, required Nut, Bolt and washers
GI angle 65x65x6mm, 450 mm bracing set complete with clamps, Nut, bolt and washers
LT XLPE insulated unarmoured 1x50 Sq. mm. Cable
Heat Shrinkable outdoor type termination kit suitable for 33kV XLPE 3x300 Sq. mm. cable size
Heat Shrinkable 1 ph. termination kit outdoor for 11 kV 3x120 Sq. mm. AB Cable
Laying of 3x300 sq. mm. 33 KV XLPE Insulated Cable underground in HDPE Pipe or trenches ( For Railway/Road Crossing)
Drilling & Laying of HT Underground Cable using HDD method without using HDPE Pipe
Loop Guard complete, 3-Phase
Spacers LT PVC
Mid Span Jointing Sleeves (95 sq. mm)
LT Insulation Piercing Connectors of 95/50 sq. mm - 70/35 sq. mm (For messenger wire jumpering & energizing DB neutral)
On/Off switch for street light connections
Mounting of cable on DP structure(including loop and riser)
Height raising channel 100X50,2240 mm long
Back clamp for height raising channel holding clamps with bolts & nuts
Cable jointing kit straight through(3X185 sqmm)
Cable jointing kit straight through(3X300 sqmm)
Extra prefabricated GI items Like clamp,channel, angle with nut & Bolt
Cable Route Marker
Tree Cutting
ACSR Rabbit Condutor
9 Meter STP Pole
13 Meter STP Pole
Rearrangement for connecting New 11 KV Switchgear with existing 11 KV Switchgears (Adopter Panel)
Al binding wire
Sign Borad
Road Restrotion (WBM )
NCC LIMITED
M/s. Ashoka Buildcon Ltd
LARSEN AND TOUBRO LIMITED
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid