Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.4 LAccepted-AOC NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Quoted lowest and reasonable | |
| 2 | L2₹97.5 L+₹3.5 L (3.67%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Quoted high rate | |
| 3 | L3₹1.1 Cr+₹12.9 L (13.7%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L3 | Rejected-Finance Quoted high rate | |
| 4 | L4₹1.1 Cr+₹13.8 L (14.7%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L4 | Rejected-Finance Quoted high rate |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
6 Mar 2025, 6:00 pmClosed
Col Alex Antony CWE Sri Vijaya Puram
Col Alex Antony Commander Works Engineer Military Engineer Services Minniebay Junglighat PO Sri Vijaya Puram - 744 103
81162 SPECIAL REPAIRS TO REPLACEMENT OF CORRODED WATER SUPPLY PUMPING AND DISTRIBUTION SYSTEM FROM BUNIYADABAD PUMP HOUSE TO CERTAIN PLACES AND OTHER SANCTIONED WORK UNDER GE HADDO, SRI VIJAYA PURAM
2025_MES_695589_1
81162 SPECIAL REPAIRS TO REPLACEMENT OF CORRODED WATER SUPPLY
Open Tender
Pipes and Pipe related activities
Item Rate
270 days
Sri Vijaya Puram
As Per NIT
2 documents required · 2 mandatory
₹1,000
GE Haddo
₹1.9 L
Yes
8 Jul 2025
30 Jan 2025
13 Mar 2025
30 Jan 2025
6 Mar 2025
20 Feb 2025
31 Jan 2025 - 7 Feb 2025
Amount
Taking down old unserviceable CI pipe lines of size 150 mm dia including fittings complete all as specified and directed.
Taking down old unserviceable CI pipe lines of size 100 mm dia including fittings complete all as specified and directed.
Taking down old unserviceable GI pipe lines of size 80 mm dia including fittings complete all as specified and directed.
Taking down old unserviceable GI pipe lines of size 50/40 mm dia including fittings complete all as specified and directed.
Taking down old unserviceable GI pipe lines of size 32/25 mm dia including fittings complete all as specified and directed.
Taking down old unserviceable GI pipe lines of size 20 mm dia including fittings complete all as specified and directed.
Supply & fixed to wall, laid in trenches / floor, wall ceiling GI tubing medium grade ISI marked complete with all fittings, accessories complete all as directed of the following sizes :-
80 mm bore
50 mm bore
25 mm bore
20 mm bore
S&F in repairs for Gunmetal gate valve, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, as fixed in repairs complete all as specified and as directed by the Engineer-in-charge of the following diameters:-
50 mm bore
25 mm bore
20 mm bore
M & L for Ductile iron pipe socket spigot centrifugally cast (spun) including suitable specials class A,K-9, in any length, laid in trenches/floors or on supporting pillar of size 150 mm dia as per IS-8239/2000 and with inside cement mortar lining and out side with blue in colour including rubber gasket joints complete all as specified and as directed.
Material,labour and laying of ductile iron pipe of size 100 dia flanged type (both end flanged) centrifugally cast (spun) including suitable specials class A, K-9, PN 16 in any length, laid in trenches/floors or on supporting pillar of size 100 dia as per IS-8239/2000 and with inside cement mortar lining and out side with blue in colour complete all as specified and as directed. Note : The quoted rate shall deemed to include the cost of the suitable GI nuts and bolts.
Supply and laying of Ductile Iron Pipe line socket and Spigot pipe as of Class K-7, ends with internal cement mortar lining and external zinc coating (minimum 130 grams/sqm) and bitumen finishing layer (minimum 70 micorn thickness), confirming to IS 8329:2000 (Amended No 1) in any length alongwith jointing materials such as rubber tyton joints of size 100 mm (4") dia including all as specified and directed.
Supply and fix in repairs for 150 MM sluice valve, class PN-1.6 flanged and drilled at both ends confirming to IS:14846 with ISI mak, having brass spindle including clamps and check nuts and gun metal rings including wheel for operation all as specified including all joints with rubber gasket and jointing materials, bolts, nuts, washers etc with the following sizes complete all as specified and as directed.
Supply and fix in repairs for 100 MM sluice valve, class PN-1.6 flanged and drilled at both ends confirming to IS:14846 with ISI mak, having brass spindle including clamps and check nuts and gun metal rings including wheel for operation all as specified including all joints with rubber gasket and jointing materials, bolts, nuts, washers etc with the following sizes complete all as specified and as directed.
Supply and fix in repairs for 80 MM sluice valve, class PN-1.6 flanged and drilled at both ends confirming to IS:14846 with ISI mak, having brass spindle including clamps and check nuts and gun metal rings including wheel for operation all as specified including all joints with rubber gasket and jointing materials, bolts, nuts, washers etc with the following sizes complete all as specified and as directed.
Supply and fix Cast Iron in repairs for Air Valves with double air Outlets, conforming to IS 14845 of size 150 mm dia bore and fixing up in Cast Iron Water supply mains including all as specified and directed.
Supply and fix Cast Iron in repairs for Air Valves with double air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains including all as specified and directed.
Material and labour for plain cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in foundation, filling and mass concrete including use and waste of form work complete all as specified and directed.
Material and labour for supporting pillar constructed of masonry of dimensions as required on site with precast cement concrete solid block masonry in PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) 20 mm thick in CM (1:6) complete all as specified and directed.
M & L for Preparation of newly plastered surface of wall and apply two coats of oil bound distember over a coat of average 1 mm thick wall care putty to make the surface smooth complete all as specified and directed.
M & L for 15 mm thick plaster in CM 1:4 on fair face of brick walls or concrete surface including mixing of liquid water proofing compound @ 200 ml per 50 kg cement bag, finished the surface even and smooth without using extra cement complete all as specified and directed.
Supply and fixing in repairs for water meter industrial type, magnetically coupled, screwed, supplied and installed complete of size 150 mm dia complete all as specified and as directed.
Supply and fix in repairs for Strainer Y type conforming to IS, size 150 mm (6”) dia complete all as specified and directed.
M&L for Cutting the existing bituminous/ cement concrete road to any length and width but 60 cm in depth as required at site for laying galvanised steel tubing as protection pipe for cable including earth work excavation in any type of soil, RFR and removing surplus soil as directed and making good the disturbed top surface and also provide the bituminous complete all as specified and directed.
S&F Rotational moulded polyethylene 5000 Ltrs PVC water storage tank Double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including old UNSV tank and fittings complete all as specified and directed.
S&F Rotational moulded polyethylene 2000 Ltrs PVC water storage tank Double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including old UNSV tank and fittings complete all as specified and directed.
S&F Rotational moulded polyethylene 1000 Ltrs PVC water storage tank Double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including old UNSV tank and fittings complete all as specified and directed.
S&F Rotational moulded polyethylene 500 Ltrs PVC water storage tank Double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including old UNSV tank and fittings complete all as specified and directed.
S&F in repairs for 40 mm dia or bore PTMT ball valve high pressure with epoxy coated aluminium rod & high density plastic ball (minimum weight 455 grams) screwed for iron pipe with necessary GI fittings such as elbows, nipples etc., including taking down old unserviceable one complete all as specified and as directed.
S&F in repairs for 25 mm dia or bore PTMT ball valve high pressure with epoxy coated aluminium rod & high density plastic ball (minimum weight 455 grams) screwed for iron pipe with necessary GI fittings such as elbows, nipples etc., including taking down old unserviceable one complete all as specified and as directed.
S&F in repairs for 20 mm dia or bore PTMT ball valve high pressure with epoxy coated aluminium rod & high density plastic ball (minimum weight 455 grams) screwed for iron pipe with necessary GI fittings such as elbows, nipples etc., including taking down old unserviceable one complete all as specified and as directed.
Excavating in trenches hard soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out including all as specified and directed.
M&L for returning, filling in including spreading, levelling,watering and well ramming in layers not exc 25cm in hard dense soil complete all as specified.
Removing excavated materials (soils) n exc 50m and depositing where directed at a level n exc 1.5m above the statrting point complete all as specified.
S & F for framed work such as grills, gratings, etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work con-forming to Fe. 290. Gde-E-165 including taking down old structre all as spefied and directed.
M & L for in repairs for Run Lead joint of size 150 mm dia including all as specified.
M & L in repairs for Run Lead joint of size 100 mm dia including all as specified.
Supply and fix in repairs for CI fitting for spigot socketed pipe such as bends (any type , radius and angle) tapers any type , (straight , bend increasing , decreasing or double socket etc) tee pieces single branch , Y junction double branch , of size - up to 150 mm dia all as specified and directed.
M&L for construction of Brick Masonary valve chamber of size 900x900x900mm (internal dimensions) with PCC 1:4:8 foundation 100mm thick, brick work using PCC block masonary 200 thick wall built in CM 1:6,PCC 1:3:6 coping 50mm thick, plastering 15mm thick in CM 1:6 to all internal wall including floor,and exeternal wall upto 150mm below ground level, including excavtion earth work in hard/dense soil, MS sheet cover 4mm thick with locking arrangement with ISA 50x50x6 mm frame embedded in PCC and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed
Sree Tirumala Enterprises (BID ID -3249615)
Prasur Electricals & Engineering Co. (BID ID -3250952)
New Era Engineers (BID ID -3251264)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .