| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC 1ST FLOOR PLOT NO 16 MAHARSHI DAYANAND SARASVATI MARG SECTOR 88 FARIDABAD 121002 | FARIDABAD | FARIDABAD | HARYANA | 121002 | L1 | Accepted-AOC Awarded due to L1 | |
| 2 | Rejected-Technical HYDERABAD HYDERABAD TELANGANA 500068 INDIA UDYAM TS 09 0012645 | MEDCHAL MALKAJGIRI | TELANGANA | 500068 | - | Rejected-Technical Rejected due to L2 | |
| 3 | Rejected-Technical 3 NEW TRIMURTY CO OP HOUSING SOCIETY INGOLE NAGAR WARDHA ROAD NAGPUR 440005 MAHARASTRA | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | - | Rejected-Technical Rejected due to L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to L4 |
Tender Value
₹23.9 L
EMD Value
₹29,900
Closing Date
3 Oct 2022, 10:00 amClosed
SO EnM, SECL BHATGAON AREA
OFFICE OF SO EnM, SECL BHATGAON AREA
Carrying out structural stability tests on conveyor belt structure, RC feeder, Feeder Breaker, Bunker Structure of Bhatgaon CHP and Surge Bunker of Bhatgaon Area n Carrying out structural stability tests on Conveyor Belt structure of TB-1 and TB-3 No
2022_SECL_256715_1
GM/Bhat/EM/e-open tender/2022-23/33 dtd. 18.09.22
Open Tender
Miscellaneous Works
Item Rate
45 days
SECL, BHATGAON AREA
Refer to NIT
9 documents required · 9 mandatory
₹29,900
21 Dec 2022
19 Sept 2022
4 Oct 2022
19 Sept 2022
3 Oct 2022
19 Sept 2022
19 Sept 2022 - 26 Sept 2022
Amount
Item Description/ Heading
Carrying out structural stability tests on conveyor belt structure, RC feeder, Feeder Breaker, Bunker Structure of Bhatgaon CHP
Components to be tested: (A) Conveyor Belt length- C1-150 mtrs, C2-30 mtrs, C3- 125 mtrs, C4- 95 mtrs, C5- 90 mtrs, C6-25 mtrs, C7- 440 mtrs, C8- 40 mtrs , (B) Bunker-02 Nos; RCC construction Capacity: 9000T (C) All the Vital parts associated with Bunker, Gantry Structure and its columns, frames
(A) Non Destructive Test
Ultrasonic test as per ASME Sec V, Article-23, , Magnetic particle test ( Of Iron/Steel & Concrete) & Foundation structural Analysis
Feeder Breaker & RC Feeder- All the Vital parts
Non Destructive Test
Ultrasonic test as per ASME Sec V, Article-23, , Magnetic particle test ( Of Iron/Steel & Concrete) & Foundation structural Analysis
Surge Bunker- 1600 Te- All the Vital parts
Non Destructive Test
As per ASME Sec V, -23, Ultrasonic test ,Magnetic particle test ( Of Iron/Steel & Concrete) & Foundation structural Analysis
Carrying out structural stability tests on Conveyor Belt structure of TB-1 and TB-3 No bunkers with reciprocation feeders of Coal Handling plant (CHP) of Shiwani UG mine of Bhatgaon Area.
Components to be tested: (a) Bunker capacity 100 Te : 03 Nos, (b) RC Feeder: 03 Nos, © Gantry Structure : 720 mtrs , (d) Columns ,beams, & frames of Bunker and Hopper Structure, € Vital welds, Joints of the bunker structure
Non Destructive Test
Ultrasonic test, Magnetic particle test, dye penetrant test as per ASME Sec V- Article-23
Vibration Analysis
Other Physical Analysis
Mechanical Testing, Chemical and Microstructure analysis of bunker material sample - 03 Nos. i) Standard test methods for tension testing of metallic material ASTM E8M- 04 ( ASTM E8M-13)
Foundation Structure Analysis
Fatigue Testing of bunker material sample -03 Nos. i) Standard test methods for tension testing of metallic material ASTM E8M- 04 (ASTM E8M-13)
Total impact of GST for the purpose of CTC
Kalva Engineers Pvt Ltd.
M/S. BECQUEREL INDUSTRIES PVT. LTD.
NATIONAL BUILDING MATERIAL LAB
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_265431.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .