| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-Finance | L1 | Accepted-Finance LOWEST BIDDER | |
| 2 | L2₹29.3 L+₹36,446.50 (1.26%)Rejected-Finance WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹32.6 L+₹3.7 L (12.9%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹35.4 L+₹6.5 L (22.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Oct 2021, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Mil Stn Bikaner
REPAIR / REPLACEMENT OF CERTAIN B/R AND E/M WORKS INCL JOINERY IN VARIOUS BLDGS OF NORTH CAMP AND EAST CAMP AND DBS AT AGE MFFR AND REPAIR /MAINT OF EXTERNAL ELECTRIC WORKS AND LT UG CABLES AT NORTH CAMP, EAST CAMP AT MFFR
2021_MES_473256_1
GE (N) BKN TOKEN NO 42/2021-2022
Open Tender
Civil Works
Item Rate
330 days
GE (N) Bikaner
Class D Category a (i)
8 documents required · 8 mandatory
₹500
GE (N) Bikaner
₹70,000
Yes
7 Oct 2021
6 Sept 2021
6 Oct 2021
6 Sept 2021
4 Oct 2021
20 Sept 2021
Amount
Demolition of brick work built in cement mortar including all quoins, arches pillars etc all as specified.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete.
Demolition wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets complete all as specified.
Dismantling asbestos cement /MS (corrugated, semi corrugated etc) sheets of any thickness in roof coverings including ridges complete all as specified.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each leaf complete all as specified.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) etc complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified.
Taking down cement plaster of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M&L Brickwork with Fly ash bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified.
All as per srl item 09 above but except bricks.
Dismantling floor, heath or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for 20 mm thick machine cut Kota stone flooring over cement screed base laid and jointed with grey cement slurrry mixed with pigments to match the shade of the slab including rubbing and Mirror finish polishing complete all as specified.
All as per srl item 12 above but kota stone slab 18-20 mm thick in riser of steps, skirting, dados and pillar laid over cement screed and jointed etc.
M&L White Marble strips 20mm thick 100mm wide machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing etc complete all as specified.
M&L for coloured non-skid tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all specified.
M&L for coloured non-skid tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all specified.
M&L for coloured glazed ceramic tiles of size 350x250 x7mm/450x350x7mm thick as in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles etc complete all as specified.
M&L 15mm thick screed bed or bedding layer for floor finishes in CM 1:6 all as specified.
M&L for 10mm thick screed bed or bedding layers for laying of vertical surface of wall in cement mortar 1:4 as on dados skirting and vertical surface complete all as specified.
M& L for 75mm thick PCC 1:3:6 type C-1 (Using 20mm gradede crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-290 (Gde E- 165) complete all as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of sand colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & Fixed in repair Gypsum board of any size for ceiling/walling including all necessary fittings complete all as specified.
supply and fixing anodized snap grid frame work size 605mmx605mm for false ceiling including necessary notching. The snap grid shall consist of aluminium main &cross tee of size 36.5x25x1.40mm weighing 0.24 Kg/RM and 23.5x26.4x1.40mm weighing 0.191 Kg/RM respectively. The main and cross tee shall be jointed at junction crossing with anodized aluminium angle bracket of size 15mmx15mmx1.5mm weighing 0.12 Kg/RM fixed with suitable MS bolts, nuts and washer. The snap grid (main/cross tee section) shall be supported at ends all along the wall with anodized aluminium angle of size 40x25x2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and providing 12mm thick cement fibre board of make Everest in fixed in grid support with 2.50mm dia plain mild steel wire galvanised class 3 fixed in detached works etc to support snap grid, made of aluminium as per specification complete all as specified and directed by Engineer-in-charge.
M&L Rendering 15mm thick in cement mortar 1: 6 on other than fair faces of brick work or concrete surfaces including finished fair and even surfaces complete all as specified.
M&L Rendering 15mm thick in cement mortar 1: 4 on fair faces of brick work or concrete surfaces including finished fair and even surfaces complete all as specified.
M&L for 1.25 mm thick MS Pressed steel frames of size 125mm x 60mm, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified supply and fixed .
M&L for 1.25 mm thick MS Pressed steel frames of size 105mm x 60mm, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete as specified supply and fixed .
S&F steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded.all as specified.
S&F steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded.all as specified.
S & F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified
Supply and fixing factory made plain framed panelled shutters (two panel ) 30mm thick 2nd class hardwood with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces . the size of rail and stile as per IS: 1003 ( Part -I) kiln seasoned and chemically pressure treated. complete fixed to chowkats all as specified.
M& L for PCC (1:3:6) type C-1 (Using 20mm gradede crushed stone aggregate) as in roof kerbs, back filling of frame complete all as specified.
S&F 30mm thick Flush shutters with both sides decorntiner film (sunmica) , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified.
Supply and fixing( factory Made ) 2nd class hard wood 35 mm thick glazed and skelton shutters open rebated and prepared to receive gauge. (Without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a) supplied and fitted to chowkats complete all as specified.
S&F factory made solid panel PVC door shutter with MS square tube 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC sheet stirip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top,lock and bottom rail on either side & as gap insert for top rail & bottom rail .panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement S&F in the steel frame at site as per specification.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified and approved.
S&F butt hinges, medium weight, cold rolled mild steel,100mm size all as specified
M&L 125mm size aluminium handles, cast type, anodised all as specified
S&F 200mm size aluminium anodised, barrel tower bolts of extruded section and fixed all as specified
S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified
S&F 150mm long Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor all as specified
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete
S&F stainless steel wire cloth,0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanisied wire staples all as specified.
All as per srl item 44 above but fixed in repairs
S&F 3mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc. 0.5 sqm in each pane all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from from old wooden or metal frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads etc including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified.
S&F Bib taps long body chromium plated cast copper alloy with crutch or butterfly handle, fancy type, CP screwed down, screwed for iron pipe or for brass ferrule 15mm bore, fixed in repairs complete.
S&F Bib taps PTMT short body screwed down, screwed for iron pipe or for brass ferrule 15mm bore, fixed in repairs complete.
M&L 4mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc. 0.5 sqm in each pane all as specified.
Supply and Fixed in repairs fancy type chromium plated angle valves cast copper alloy screwed down high pressure fixed to pipe of 15mm bore all as specified.
Taking up or down GI steel water tubing and connection including cleaning for refixing of 15mm bore all as specified.
Taking up or down GI steel water tubing and connection including cleaning for refixing of 20mm bore all as specified.
Dismantling water tanks exceeding 250 and not exceeding 500 litres capacity and removing to store complete.
Dismantling water tanks exceeding 500 and not exceeding 1000 litres capacity and removing to store complete.
Dismantling water tanks exceeding 1000 and not exceeding 2000 litres capacity and removing to store complete.
M&L for GI tubing 15mm bore with all fittings fixed to walls, ceilings or laid in floors medium grade all as specified
Refixing old steel tubing and connections in new or old position (walls,ceiling, floors etc 15mm bore of pipe
M&L for GI tubing 20mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade all as specified
Refixing old steel tubing and connections in new or old position(walls,ceiling, floors etc 20mm bore of pipe
M&l Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) ISI marked triple layered of 500 litres capacity (white colour) , hoisted and fixed in position including connecting up pipes, fixed in repairs complete.
M&L Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) ISI marked triple layered of 1000 litres capacity (white colour) , hoisted and fixed in position including connecting up pipes, fixed in repairs complete.
M&L Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) ISI marked four layered of 2000 litres capacity ( white colour) , hoisted and fixed in position including connecting up pipes, fixed in repairs complete.
S&F Ball valves, high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball , screwed for iron pipe or brass ferrule 25 mm bore fixed in repairs complete.
S&F Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions 20mm bore complete.
S&F Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions 15mm bore complete.
S&F Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore fixed in repairs complete.
S&F Spray jet with PVC connection to EWC complete.
S&F Vitreous china wash basin, white, flat back, size 550 x 400mm, including brackets and cutting for and pinning in ends of brackets, fixed in repairs including 32mm bore brass chromium plated waste fitting and 32mm bore PVC waste pipe of sufficient length complete.
S & F syphonic action PVC low level flushing cistern of 10 ltr capacity including internal fittings, brackets,32mm flush pipe etc, fixed in repairs complete.
S & F flush kit for syphonic action PVC low level flushing cistern of 10 ltr capacity fixed in repairs complete.
S&F in repairs Vitreous China wash down water closet pan, pedestal pattern, coloured, fixed in repairs including PVC seat cover black/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and fixing bolts and making connections to flushing cistern complete
S&F in repairs Vitreous China WC seat Orrisa pattern size 580 x 440mm, white with integral foot rests fixed in repairs including cast iron ‘P’ or ‘S’ trap, lime concrete in sunken floor making connection with flush pipe using new GI flush bend (Floor portion) and making good to floors, matching to existing surfaces complete.
S&F PVC connection 450 mm long for 15mm dia pipe having CP brass nuts with washers on both ends, fixed in repairs complete.
S&F in repaire Plastic water closet seat cover, black/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as speified
S&F Tubular towel rail of brass chromium plated, 20mm dia, D type, 60cm long between flanges fixed in repairs complete.
M&L Preparation of new plastered or unplastered surfaces of wall and applying two coats of white or tinted oil bond distemper over a coat of primer complete all as directed and specified.
M&L Preparation of new plastered or unplastered surfaces of wall and applying two coats of white wash all as directed and specified.
M&L Preparation of new plastered or unplastered surfaces of wall and applying two coats of white or tinted cement base paint over a coat of primer complete all as directed and specified.
M&L preparation of new or previously untreated surfaces of steel of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of a red oxide primer.
Supply & fixing Flush pipe of polyethylene for PVC, 32 mm dia for low level cistern in repairing to EWC or IWC including all necessary work reqd at site etc.
S&F in repairs PVC (SWR) pipes, 110mm dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified.
S&F PVC (SWR) bends any radius 110mm dia
S&F PVC (SWR) branch piece 110mm bore, single (single Y) equal or unequal
S&F PVC (SWR) reducers 110mm bore
S&F PVC (SWR) vent cowl 75mm bore
S&F in repais PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to walls with clamps etc complete all as specified and directed.
Taking down carefully existing unserviceable batten/surface conduit/ concealed conduit aluminium point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc including sunken boxes and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and as directed by the Engineer-in-Charge.
Taking down of unserviceable DBs/ switch fuses/ change over in sheet steel enclosure complete with MCBs /Fuses /grips any capacity after disconnecting all cables etc and removing from site and making good disturbed surface of wall, floor etc. complete all as specified and as directed by Engineer-in-Charge.
M&L Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC FRLS cable of size 1.5 Sq mm stranded core in and including PVC Conduit/casing capping with all fittings such as tees, bends etc terminating in MS sunken box/wooden box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’ for one fan or light or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.50 Sqmm PVC FRLS copper conductor cable, as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No. 90 here-in-before but socket point on the same board
All as per item No. 90 here-in-before but socket point on independent board
Ditto- all as per srl item No 90 here-in-before but with multi stranded copper conductor cable, 1100 volts grade (ISI marked), PVC FR cable of size 2.5 Sqmm single core and including 2.5 Sqmm PVC FR single core copper standed conductor cable as earth continuity conductor to common earth and earth dolly for one 15 Amp socket outlet point on the independent board complete all as specified and as directed by Engineer-in-Charge.
S&F Switch piano flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F Socket outlet 3 pin 5 amp flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge .
S&F Switch piano flush type, Single pole 15 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F Socket outlet 3 pin 15 amp flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge .
S&F Ceiling rose, 3 terminal PVC/ polycarbonate isolated body, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F Fan regulator electronic type 230 Volts,150 watt with 5 step control suitable for 1200/1400 mm sweep ceiling fan, complete all as specified and as directed by Engineer-in-Charge.
S&F Lamp holder PVC/ polycarbonate insulated body with black plate for conduit / casing caping complete all as specified and as directed by Engineer-in-Charge .
S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB of capacity 20 Amps complete all as specified and as directed by Engineer-in-charge.
S & F in replacement bulk head luminaries suitable for CFL lamp 1 x 9 watt with plastic enclosures and opal acrylic diffuser, including CFL lamp complete including making connection with suitable size copper flexible wire all as specified and as directed by Engineer-in-Charge
S&L in replacement PVC Alumionioum conductor cable 4.0 Sqmm x 02 core for suitable service coonection complete all as specified and as directed by Engineer-in-Charge.
S&L in replacement PVC Copper conductor cable 6.0 Sqmm x 02 core for suitable service coonection complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Sheet metal enclosure for DBs, double door concealed type suitable for fixing of MCBs, 8 way, Single pole and neutral 240 volts with rated bus bar of 200 Amps capacity including making good the disturbed surfaces of wall to match with the existing complete all as specified and as directed by Engineer-in-Charge.
All as per item No 105 here-in-before but SPN, 04 Way
All as per item No 105 here-in-before but SPN, 02 Way
S&F MCB single pole, 240 volts of rating 6-40 Amps of C curve breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge
S&F isolator DP 32 Amps 240 volts complete all as specified and as directed by Engineer-in-Charge.
S&F MCB suitable for 6 to 40 Amps, 240 Volt AC supply 'C' Curve single pole and neutral (SPN) with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of linear DLX decorative ultra slim linear LED light fitting with extruded aluminium heat sink, enviranment friendly energy efficient ready to use pack lamp type 18/20W LED 6K (4') type LHDD01102674 Make:- Halonex/Syska/Havells
S & F in replacement of LED Bulb of capacity 9 watt Make:- Halonex/Syska/Polycab
Supply & fixing Rigid non-metallic PVC conduit of size 20 mm dia inclusive of all tees, bends,elbows,juction box, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. all as specified and as directed by Engineer-in-Charge
Supply & fixing Rigid non-metallic PVC conduit of size 25 mm dia inclusive of all tees, bends,elbows,juction box, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. all as specified and as directed by Engineer-in-Charge
Supply & fixing PVC casing caping 20 mm inclusive of all tees, bends,elbows and fixing accessories such as couplers, lock nails, etc. all as specified and as directed by Engineer-in-Charge
Supply & fixing PVC casing caping 25 mm inclusive of all tees, bends,elbows and fixing accessories such as couplers, lock nails, etc. all as specified and as directed by Engineer-in-Charge
Supply & fixing PVC board suitable for one switch and socket of capacity 5 Amps all as specified and as directed by Engineer-in-Charge
Supply & fixing PVC board suitable for two switch and one socket of capacity 5 Amps all as specified and as directed by Engineer-in-Charge
Supply & fixing PVC board suitable for three switch and one socket of capacity 5 Amps all as specified and as directed by Engineer-in-Charge
Supply & fixing PVC board suitable for four switch and one socket of capacity 5 Amps all as specified and as directed by Engineer-in-Charge
Supply & fixing PVC board suitable for five switch and one socket of capacity 5 Amps all as specified and as directed by Engineer-in-Charge
Supply & fixing PVC board suitable for six switch and one socket of capacity 5 Amps all as specified and as directed by Engineer-in-Charge
Supply & fixing PVC board suitable for one switch and one socket of capacity 15 Amps all as specified and as directed by Engineer-in-Charge
Supply and Fixing PVC flexible pipe of size 20 mm dia including PVC clamp etc. complete all as specified and as directed by Engineer-in- Charge.
Supply and Fixing PVC flexible pipe of size 25 mm dia including PVC clamp etc. complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing in replacement Switch socket combination 2 in 1, 5 A flush type with PVC board complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing in replacement Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal with PVC board complete all as specified and as directed by Engineer-in- Charge.
Supply only PVC insulation tape for day by day complaint /maintenance all as specified and as directed by Engineer-in- Charge.
Supply only multistranded copper conductor of size 1.5 Sqmm single complete all as specified and as directed by eng-in-charge Make :- Polycab/Havells/Finolex
Supply only multistranded copper conductor of size 2.5 Sqmm single complete all as specified and as directed by eng-in-charge Make :- Polycab/Havells/Finolex
Supply and fixing in replacement new generation energy saving and enviromental friendly long life LED security light 40 Watt made up pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 Make :- Havell/C&S/Surya
Supply only Switch piano, flush type single pole, one way 5 Amp for complaint/ maintenance all as specified and as directed by Engineer-in- Charge.
Supply only Switch piano, flush type single pole, one way 15 Amp for complaint/ maintenance all as specified and as directed by Engineer-in- Charge.
Supply only Socket outlet 2 in 1, 3 pin, 5 Amp for complaint/ maintenance all as specified and as directed by Engineer-in- Charge.
Supply only Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type for complaint/ maintenance all as specified and as directed by Engineer-in- Charge.
M & L for taking down board / fittings fixtures indentifying and rectifing the complaints pertain to internal electrification of any type and nature of single living barracks / OTMs bldg, sub station, water supply installations and officers living accn and camp officers such as rectificaion of faulty electric circuits, tighting of loose wiring (concealed/condult/ casing and caping) . condult replacement and defective switch sockets, light fittings, replacement of broken hylam sheets, MCB's, main switches, DB's change overs etc all as directed by engineer-in-charge. (Note :- cost of minor stores such as screws, clamps, insulation tapes, nuts/ bolts etc. Shall be deemed included in the above quoted item, (II) cost of major items ie. LED tube,electronic ballast,switch,socket etc shall be measured and paid seprately under respective items. (iii) contractor shall received the complaints daily from the complaints cell (JE E/M) & rectifiying same day and submitt the complaints slips duly signed by the users. (iv) One complaints slip ( max no of complaints are four ) shall be the each job.
S&F in repair Thermostat switch I.S.I marked, to Geysers 25/50 ltrs Make : Alert/Theta /Bajaj.
Supply and fix in replacement heating element of rating 1.5 KW capacity including washers for 25 ltrs capacity Geysers.Make :- “THETA/ ALERT”
Supply and fix in replacement heating element of rating 2.0 KW capacity including washers for 50 ltrs capacity Geysers.Make :- “THETA/ ALERT”
Supply and fix in replacement Indicator lamps as per existing type having red or green coloured reflector all as specified and directed by Engineer-in-Charge
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by means of GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel up to 7.5 metre and connecting to earthing test point, main switch board or panel, testing on completion including GI pipe 20 mm dia light grade 30 cm above ground level with plug at top for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I including testing on completion complete all as specified and as directed by Engineer-in-Charge. (Notes : - (i) G.I pipe 20 mm dia light grade from earth electrode upto main switch panel for protection of earth lead wire shall be deemed to be included in the unit rate quoted for earthing)
Notes for Sl item No. 142 to 191:- 1. Contracotor must attend the complaint within 24 Hours and resolve within 48 hours if failed to attend, peanlaty of Rs 1000 per day will be deducted b) Contractor must deploy a dedicated faullt investigation and rectifying team for this work or as specified by Enginneer in charge. Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge.
All as per Srl item No. 01 here in before but exc 1.5m and not exceeding 3.0 in depth complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by the Engineer-in-Charge.
M&L Protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ burnt-clay bricks having compressing strength not less than 75 kg/Square cm complete all as specified and as directed by the Engineer-in-Charge.
M&L Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations of poles above ground level including finishing to exposed concrete surfaces even and fair and provision of form work for rough finished surface complete all as specified and as directed by Engineer-in-charge.
M&L Plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations for stays and coping complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking down old damaged/broken pre-stressed concrete/steel LT electric poles of any type inclding breaking down existing pcc foundation and removing from site complete all as specified and as directed by the Engineer-in-Charge.
Taking out old U/S panel any type any description and size carefully by disconecting LT cables carefully after ensuring proper shut down incl breaking up old pcc complete all as specified and as directed by the Engineer-in-Charge.
Taking out old U/S street light or street light fittings with brackets from poles, wall etc any type and description complete all as specified and as directed by the Engineer-in-Charge.
Taking out old US/faulty PVC armoured/un-armoured LT under ground cable of size 10 Sqmm to 120 sqmm 2/3 1/2 4 core complete all as specified and as directed by the Engineer-in-Charge.
M&L Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts LT grade of cross-sectional area 06 Sqmm 2 core laid in trenches/through pipe in road crossings/paths/drains/ducts/floors/along poles/walls/ceilings/equipments etc supplied and fixed including commissioning and testing complete all as specified and as directed by the Engineer-in-Charge. Notes : (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (ii) Road/boring roads manualy cutting/floor cutting/cutting holes etc in wall required for laying fising of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same.
Ditto All as per srl item No. 154 here in above but aluminium conductor 100 Volts LT of size 10 Sqmm 2 core
Ditto All as per srl item No. 154 here in above but aluminium conductor 1100 Volts LT of size 16 Sqmm 2 core
Ditto All as per srl item No. 154 here in above but aluminium conductor 1100 Volts LT of size 25 Sqmm 4 core
Ditto All as per srl item No. 154 here in above but aluminium conductor 1100 Volts LT of size 35 Sqmm 3.5 core
Ditto All as per srl item No. 154 here in above but aluminium conductor 1100 Volts LT of size 50 Sqmm 3.5 core
Ditto All as per srl item No. 154 here in above but aluminium conductor 1100 Volts LT of size 70 Sqmm 3.5 core
Ditto All as per srl item No. 154 here in above but aluminium conductor 1100 Volts LT of size 95 Sqmm 3.5 core
Ditto All as per srl item No. 154 here in above but aluminium conductor 1100 Volts LT of size 120 Sqmm 3.5 core
M&L Boring of holes under road, pavement, hard standing by manually without damaging of road, material & labour including pipe 80/100 mm dia suitable complete all as specified and as directed by the Engineer-in-Charge. Note; lenth of pipe to be measured and paid seperately under relavant item
Supply and fixing in replacement of LED based street lights, housing made of pressure die cast aluminium alloy with effective thermal management sturdiness. The fixture should have a minimum system efficacy of more than 80 lumen/Watt and a minimum system lumen output of not less than 3600 lumens and maximum system wattage 45 watts. The fuxture shall have a color temperature of minimum 5000k at a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, lngress protection of IP66 (lamps and gear compartment and Mechanical Impact) Resistance Rating of IK>= 05. The fixture should comply with the parameters as per IEC 60598 and IS 10322, and LED drive should apply to IEC 61000-3-2 ed 3.2. per haronics IEC 61347-2-13, 2006 in confirmation with IEC 61347-1 ed, 2.0, 2007 for electrical safety, LM 79 and LM 80 test report needs to be sumitted above parameters. The fixture driver should have an operating voltage range of 140-300V, frequency 50-60 Hz, surge protection not less than 4KV, PF>0.95 and THD<15%. The driver should have double phase protection. LED lights fitting should be suitable for ambient temperature from (-) 10 digree C to (+) 50 digree C, including street light GI bracket 40mm dia bent to shape 1200 and down 15mm Bore GI pipe with GI clamps with junction box for fixing LED light required, with suitable size clamp, nut bolts and washers as per site requirement complete all as specified as directed by Engineer-in-charge. (Note-The manufacture of LED fitting shall give Guarantee for 5 years from the date of installation and complete fixed with suitable bracket & Accessories) Make-Phillips, CG, Bajaj, Wipro, C&S and surya.
Supply and fixing in replacement for two core PVC insulated weather proof cable with aluminum conductor size 4 sqmm (nominal area), & drawing into hollow street light pole from fitting to juntion box or fitting to over head line complete all as specified and as directed by the Engineer-in-Charge.
M&L Pre-stressed concrete poles 9 meter long, 102mm x 172 mm at top and 102 mm x 279 mm at bottom, class 10, complying with requirements of IS-1678, including painting with two coats of synthetic enamel paint (in alternate black & white/yellow strips of 30 cm height) upto 1.5 meter height from top of PCC coping and also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint incl required iron channels/clamps/GI pipe for the protection of flexible cable connecter box with bus bars, bolts & nuts complete all as specified and as directed by the Engineer-in-Charge.
S&F in replacement GI pipe light grade 50 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/Ceiling/along walls/path/drain/floors with and including all necessary clamps, nuts, bolts washers etc all fittings as required complete all as specified and as directed by the Engineer-in-Charge. (Note: - excavation, earth work and same work shall be measured and pain for separately.)
Ditto All as per srl item No 167 here in above but dia of pipe 40 mm.
M&L Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre depth below normal ground level) with top edge of plate at a depth not less than 1.5 mtr below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 04 mm dia with and including bolts, nuts, check nuts and washers of galvanised iron or steel and riveted to earth plate and one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 15 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and including flatiron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 03 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including neessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed by Engineer-in-Charge. (Notes 1. The rate quoted shall be deemed to include for all the above provisions. 2. PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting maner) .
M&L Cable jointing kit for LT 1100 V cable for straight through end termination (Epoxy), hot shrinkable type joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm 3.5/4 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-charge.make: m seal/dension.
Ditto all as per srl item No. 170 here in above but 70 to 95 Sqmm
Ditto all as per srl item No. 170 here in above but 120 to 150 Sqmm
S&F inreplcement of change over switch 200 Amps, four pole, 415 Volt, cubical type and including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge Make-C&S, Cat part-CSSDF200B4CO or equivalent cat part in make Crompton Greaves/L&T/Siemens/Alstom.
Repair the following work to existing bus bar chamber(pillar box) outdoor cubical type factory made vermin protected dust proof, water proof made out of MS sheet 1.6 mm thick and 50 cm x50 cm x6mm thick angle iron base frame having insulated bus bar aluminum 200amps cap 3 phase with neutral bus bar including fixing in PCC bed block complete all as reqd at site and as directed by Engineer in Charge with following item no 33-35 (a) welding of brocken/cracked joints of the feeder pillar box
(b) Replacing to locking arrangement of the feeder pillar box as per sample existing.
M&L Painting with one coat of synthatic enamel paint after applying one coat of red oxide as a primer complete all as specified
S&F in replacement of US Feeder pillar box outdoor cubical type factory made vermin protected dust proof with canopy, water proof made out of MS sheet 1.6 mm thick and 50 cm x50 cm x1.6mm thick angle iron base frame having insulated bus bar aluminum 200amps cap 3 phase with neutral bus bar including fixing in PCC bed block complete all as reqd at site of all four camps and DBS as directed by Engineer in Charge.
M&L for Aluminium conductor, steel reinforced (ACSR) of size 3/6x2.59 mm/make including jionting for over head line on pole including binding wire 14 SWG, jumpers line tapes etc complete all as specified and as directed. ( for measurement and payment purpose of ACSR the weight of winding wire shall not be considered.)
M & L for repairing of broken ACSR vessal/ squarel /ferrot/ mink conductor after proper shutdown of electric supply and jumpring / cut points changing the damaged/burned conductor, cable endes, change over MCCBs condutor broken due to wind/storm and binding with the aluminium wire etc and changing the damaged pin/disc insulators and replace the broken conductor, repairing the faults in the 11/0.44 KV outdoor/ indoor electric panels at sub stations complete all as specified and directed by engineer-in-charge.( Note :- cost of fues wire minor spares, aluminium binding wire shall be deemed included in the above quoted item.,(ii) Cost of items that is pin insulator,disc insulator etc. shall be measured and paid seprately under respective items.(iii)contrator take complaints from complaints cell(JE E/M)and rectify the same day and duely signed by the users and depositedthe same.one down breakdown/coplaint by attended shall be the each job.
Supplied and fixed in repair Disc type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 145 mm height, 255 mm dia. for working pressure 11000 volts grade, complete all as specified and as directed by Engineer-in-Charge.
Supplied and fixed in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia. for working pressure 11000 volts grade, complete all as specified and as directed by Engineer-in-Charge.
M&L Cable indoor / outdoor end terminals jointing kit for LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material and accessories, thimbles etc suitable for 16 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-Charge.
Ditto All as per Srl item No . 182 here in above but 70 Sqmm to 120 sqmm 3.5 Core
Ditto All as per Srl item No . 182 here in above but 150 Sqmm to 185 sqmm 3.5 Core
M&L for repair in replacement and fixing of Maintenance free battery capacity 80 AH, 12 Volt with proper copper wire complete all as specified & directed.
M&L for repair in replacement and fixing with suitable clamp of LED solar light of capacity 15 watt complete all as specified & directed.
M&L for repair in replacement charger control/circuit for solar battery 12 volt including connecting to existing wiring circuit or complete all as specified or directed by engineer in charge
M&L for repair in replacement of solar plate /Solar Cell Module of capacity 12 Volt 3.25 watt complete all as specified & directed.
. S&F in replcement of MCCB 3 pole 200 Amp, fixed type 36 KA, 415 Volt including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge. Make- havells/HPL/Legrand
. S&F in replcement of MCCB 3 pole 100 Amp, fixed type 25 KA, 415 Volt including making fixing arrangement in existing LT control panel and with proper connection of as per existing system all as directed by the Engineer-in-Charge. Make- havells/HPL/Legrand
Gill Construction Co
M/S Shree Ram Enterprises
VIJAY KUMAR SHARMA
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .