Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.5 L+₹17,780 (0.49%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹37.3 L+₹1.0 L (2.86%)Rejected-Finance 1252 SECTOR 15 PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L3 | Rejected-Finance L3 | |
| 4 | L4₹38.7 L+₹2.4 L (6.55%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹41.4 L+₹5.1 L (14.1%)Rejected-Finance 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | K L Kataria and Sons L3 | M/s Om parkash L4 | M/s Super Trading Corporation L5 | Premier Constructions L2 | KUNDRA CONSTRUCTIONS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed. | 375 | Square Metre | 5 ₹1,875 Lowest | 20 ₹7,500 | 25 ₹9,375 | 5 ₹1,875 Lowest | 20 ₹7,500 |
| 2.00 | Glazed coloured ceramic tiles in vertical surface 450mm x 300mm x 7mm thick thick , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. | 125 | Square Metre | 525 ₹65,625 Lowest | 650 ₹81,250 | 680 ₹85,000 | 600 ₹75,000 | 700 ₹87,500 |
| 3.00 | Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick screed or bedding layer in CM 1:6, complete all as specified and directed. | 10 | Square Metre | 550 ₹5,500 Lowest | 650 ₹6,500 | 900 ₹9,000 | 650 ₹6,500 | 700 ₹7,000 |
| 4.00 | Vitrified ceramic tiles 10mm thick (square / rectangular) polished, light shade, area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over a 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed | 260 | Square Metre | 525 ₹1,36,500 Lowest | 750 ₹1,95,000 | 680 ₹1,76,800 | 675 ₹1,75,500 | 850 ₹2,21,000 |
| 5.00 | All as per serial item No 4 hereinbefore but on skirting / vertical surfaces laid over and including 10mm rendering in cement mortar 1:4, compelte all as specified and directed | 12 | Square Metre | 525 ₹6,300 | 750 ₹9,000 | 650 ₹7,800 | 500 ₹6,000 Lowest | 850 ₹10,200 |
| 6.00 | Taking down chowkats or frame not exc. 1.5 Sqm with shutters, without taking off shutters from the frame, complete all as specified and directed. | 2 | Each | 35 ₹70 Lowest | 150 ₹300 | 1,000 ₹2,000 | 50 ₹100 | 50 ₹100 |
| 7.00 | Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame, complete all as specified and directed. | 5 | Each | 35 ₹175 Lowest | 150 ₹750 | 1,000 ₹5,000 | 50 ₹250 | 50 ₹250 |
| 8.00 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge | 140 | Kilogram | 385 ₹53,900 Lowest | 450 ₹63,000 | 480 ₹67,200 | 425 ₹59,500 | 444 ₹62,160 |
| 9.00 | Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. | 140 | Kilogram | 385 ₹53,900 Lowest | 450 ₹63,000 | 550 ₹77,000 | 425 ₹59,500 | 444 ₹62,160 |
| 10.00 | 4.80mm thick ordinary quality tinted glass, fixed to aluminum frame work in panels n. exc 0.5 Sqm in each pane, complete all as specified & directed. | 10 | Square Metre | 600 ₹6,000 Lowest | 800 ₹8,000 | 1,000 ₹10,000 | 600 ₹6,000 Lowest | 850 ₹8,500 |
Tender Value
₹46.4 L
EMD Value
₹92,840
Closing Date
21 May 2025, 6:00 pmClosed
Garrison Engineer
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-12/2025-2026 PROVN OF STORAGE SHED , SPECIAL REPAIR TO BER CEILING FAN AND OTHER WORKS AGE B/R I AT CHANDIMANDIR MIL STN
2025_MES_705099_1
GE/CHM-12/2025-2026
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹92,840
Yes
6 Sept 2025
23 Apr 2025
23 May 2025
23 Apr 2025
21 May 2025
7 May 2025
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Glazed coloured ceramic tiles in vertical surface 450mm x 300mm x 7mm thick thick , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick screed or bedding layer in CM 1:6, complete all as specified and directed.
Vitrified ceramic tiles 10mm thick (square / rectangular) polished, light shade, area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over a 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed
All as per serial item No 4 hereinbefore but on skirting / vertical surfaces laid over and including 10mm rendering in cement mortar 1:4, compelte all as specified and directed
Taking down chowkats or frame not exc. 1.5 Sqm with shutters, without taking off shutters from the frame, complete all as specified and directed.
Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame, complete all as specified and directed.
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
4.80mm thick ordinary quality tinted glass, fixed to aluminum frame work in panels n. exc 0.5 Sqm in each pane, complete all as specified & directed.
Surface excavation not exceeding 30 cms deep and averaging 15cms deep and getting out complete all as specified.
Excavation in post holes (or similar hole) each in hard & dense soil n.exc 0.50 cu m getting out, returning, filling and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed.
Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
Cement concrete type B-1, 1:2:4 using (20mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. (Cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately).
Hard core of gauge of broken stone or boulders, not exc 63mm , deposited spread and lavelled in layers n.exc 15 cm thick, watered & rammed to a true surface ,complete all as specified.
Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in beams, cantileers, bressummers, lintels over 1.5 metre span and the like complete all as specified and directed (reinforcement shall be measured and paid for separately).
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and directed.
Mild steel TMT bars 6 to 8mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bending spirally including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips as in stirrups, spacers and binders , complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Machine cut Kota Stone Slab 20-25mm thick over cement screed bed laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including rubbing and ploshing complete over and including 15mm thick screed bed in CM 1:6 all as specified and directed.
All as per serial item No 23 hereinbefore but on skirting / vertical surfaces laid over and including 10mm screed layer in cement mortar 1:3, cutting, rubbing, grinding and polishing complete, all as specified.
Demolition of brick masonry and built in cement mortar including all quoins arches, pillars complete all as specified & directed
Brick work with sub class ‘B’ bricks, old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4, complete all as specified & directed.
All as per serial item No 26 herein before but except bricks (using old serviceable bricks) –ditto-
Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed.
Taking down existing plaster of any description on brick wall/ concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete, all as specified and directed.
15mm thick rendering in Cement and Sand mortar 1:6 over concrete /brick surfaces finished even and smooth without using extra cement and providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
Rendering 15mm thick plaster in cement mortar 1:4 on brick or concrete surface of wall , finished even and fair without using extra cement complete all as specified and directed by Engineer-in-charge.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper complete all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Rolled sections as in main and cross beams, hip and jack rafters,purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates, conforming to Fe-290 Gde E165, all as specified and directed.
Two coats of synthetic enameled paint on steel and iron surfaces over 10 cm width or girth over a coat of primer including preparation of new surfaces complete all as specified & directed.
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings and similar work conforming to Fe 290-0 or Fe 165-0, all as specified and directed.
Steel windows , ventilator fixed type with glazing bars, including one shop coat of red oxide zinc chrome primer, complete all as specified & directed.
3mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each panes complete all as specified and directed.
Plain cement mortar 1:3:6 (type C-2 using 40mm graded aggregate), 75mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement, all as specified.
20mm thick Granite work (of any type table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in, aid over and including 15mm thick screed bed in cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite compelte all as specified and directed.
Rounding of / moulding to edges of stone of any description including rubbing and polishing (Granite finish) complete all as specified and directed.
Applying wall care putty in new external plastered surfaces of bldg (average thickness 2mm as required for desired smoothness and leveling of surfaces in two or more layers) by using necessary scafolding and safety arrangements including sand papering after filling the putty to make surface smooth and ready to receiving exterior painting and applying two coats of exterior emulsion paint over one coat of exterior wall primer complete all as specified and directed.
Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socket or power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete
Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed.
All as per serial item 46 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed
All as per serial item 46 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 46 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed.
Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed.
Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed.
Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed.
Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed.
Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed.
LED lamp 9 watts, B-22 type complete all as specified .
Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, Complete all as specified and directed .
MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 8 way SPN with 200 Amps busbar 240V completed all as specified and directed.
MCB, SPN, 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB, SPN, 240 volt, 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB ,SP, 240 volt, 6 Amps to 32 Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
Sheet metal enclosure with socket plug and MCB Single pole and neutral 20 Amp 220 V with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.
LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed.
Slim LED lights fitting, 2 feet, 1x 10W, inverter rechargeable, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
Slim LED lights fitting, 2 feet, 1x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
Slim LED lights fitting, 4 feet, 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
Slim LED lights fitting, 4 feet, 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light omplete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed.
Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cable shall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth
Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 10sqmm and one single core earth cable of 10sqmm cable shall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth
LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,including lamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed.
LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,including lamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed.
Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) compelte all as specified and directed.
Exhaust fan energy efficient metallic blades heavy duty turbo force of size 450mm sweep, 1400 rpm, AC 230 volts complete with louvers shutters mounting on wall with holding down bolts, nuts, washers complete all as specified and directed.
Exhaust fan energy efficient metallic blades heavy duty turbo force of size 380mm sweep, 1400 rpm, AC 230 volts complete with louvers shutters mounting on wall with holding down bolts, nuts, washers complete all as specified and directed.
Exhaust fan energy efficient metallic blades heavy duty turbo force of size 250mm sweep, 1400 rpm, AC 230 volts complete with louvers shutters mounting on wall with holding down bolts, nuts, washers complete all as specified and directed.
Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm and provision of flexible copper cable 3 core from ceiling rose to exhaust fan complete all as specified and directed.
BLDC 3 blade Wall mounted fan of of size 250mm sweep made of polycarbonate ,1200 RPM, copper winding, AC 230 volts, with remote & automatic speed control complete, mounting on wall with holding down bolts, nuts, washers complete all as specified and directed.
BLDC 3 blade Wall mounted fan of of size 450mm sweep made of polycarbonate ,1350 RPM, copper winding, AC 230 volts, with remote & automatic speed control complete, mounting on wall with holding down bolts, nuts, washers complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter
Premier Constructions (BID ID -3301617)
K L Kataria and Sons (BID ID -3297011)
M/s Om parkash (BID ID -3299556)
M/s Super Trading Corporation (BID ID -3301564)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .