| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC Awarded being L1. | |
| 2 | L2₹8.1 L+₹2.0 L (32.9%)Rejected-Finance | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹8.2 L+₹2.1 L (33.9%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L3 | Rejected-Finance Other than L1. | |
| 4 | L4₹8.5 L+₹2.4 L (38.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1. | |
| 5 | L5₹9.1 L+₹3.0 L (48.6%)Rejected-Finance | L5 | Rejected-Finance Other than L1. |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
23 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
REPAIR AND MAINT TO LT EXTERNAL ELECTRIC WORKS AND PANELS AT SECTOR B AND C OF HQ CIF (K) UNDER AGE (I) CIF (K).
2024_MES_661992_1
CA NO. AGE (I) CIF (K) - 28/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
AGE (I) CIF (K)
₹20,000
Yes
25 Oct 2024
25 Jun 2024
25 Jul 2024
25 Jun 2024
23 Jul 2024
9 Jul 2024
Amount
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 Sqmm, 2 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 Sqmm, 2 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 2.0 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 2.0 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable , complete all as specified and as directed by Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron strip 25 x 4mm as earthing lead by means bolts, nuts, check nuts and washers made out of galvanised iron, 32 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh including provision of concrete pit in plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I, using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, complete all as specified and as directed by the Engineer-in-Charge. Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Replacement of existing worn out/over heated/multi jointed ACSR jumpers of LT overhead lines with PVC insulated 1100 volts grade cable of size 50 Sqmm, 3.5 core , complete all as specified as directed by the Engineer-in-Charge. Note :- Length of one jumper shall be 1.5 mtr (appx)
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker 100 Amps, 35 KA of Capacity 415 V 50 Hz, 04 Pole to be fixed on existing LT Panel. , complete all as specified and directed by the Engineer-in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker 160 Amps, 35 KA of Capacity 415 V 50 Hz, 04 Pole to be fixed on existing LT Panel. , complete all as specified and directed by the Engineer-in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker 200 Amps, 35 KA of Capacity 415 V 50 Hz, 04 Pole to be fixed on existing LT Panel. , complete all as specified and directed by the Engineer-in-Charge.
Galvanized iron tubing 50mm bore light grade with all fittings,laid in trenches or under road crossing , or fixed alongwith poles/walls with clamps made of mild steel flat iron 25mm x 3mm including GI nuts, bolts and washers as protection pipe for cables and including taking down/out old existing pipe, complete all as specified and directed by Engineer- in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays etc. and getting out in any type of soil, complete all as specified and directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other for cable protection, complete all as specified and as directed by Engineer-in-Charge.
Replacement of existing on load change over switch with new on load change over switch of capacity 100 Amp, 4 pole 415Volts 50HZ open execution, complete all as specified and directed. complete all as specified and as directed by the Engineer-in-Charge. Make- Havells cat No- IHCNF00100 or equavalent in Bajaj/Indoasian/Philips
Replacement of existing on load change over switch with new on load change over switch of capacity 325 Amp, 4 pole 415Volts 50HZ open execution, complete all as specified and directed. complete all as specified and as directed by the Engineer-in-Charge. Make- Havells cat No- IHCNF00325 or equavalent in Bajaj/Indoasian/Philips.
New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 LED street light fitting 40 watts with heat resistant toughned glass complete with all accessories and making of electrical connection with and including three core flexible copper conductor cable of suitable size, including taking down existing old unserviceable fitting, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havells Cat part No. ENDURAPEARLNEOSL40WLED 757PASYTOPC or equivalent in Phillips/Bajaj/Crompton
M&L for plain cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in foundation filling and bed plate of electric pole, struts etc complete all as spd and directed.
M&L for plain cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate as in bed plate, coping for electric pole, struts etc including form work finishing the surface even and smooth without unsing extra cement and applying two coat of white wash complete all as spd and directed.
Steel tubular swaged pole erected to truly vertical or planted as strut complete with 6mm thick cast iron/mild steel base plate continuously welded to pole, finial taper plug, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II as specified type 410 SP–31 (09 metre long) including drilling of holes of required size for fixing of cross arms and applying two coats of bituminous paint internally throughout and externally for embedded portion and with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching/coping externally including taking down old existing , complete all as specified as directed by the Engineer-in-Charge. Note: Necessary earth work, PCC foundation and coping will be measured and paid for separately under respective items.
Note :- An amount of Rs. 60,700.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/s Nasir Rasool Dar (BID ID -3056130)
M/S SHEIKH FEROOZ AHMAD (BID ID -3071692)
M/S Ghulam Mohammad Shalla (BID ID -3063662)
M/S A.M. ENTERPRISES (BID ID -3072446)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .