Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 CrAccepted-AOC | ₹39.1 Cr Quoted ₹39.7 Cr | L1 | Accepted-AOC Accepted being lowest |
| 2 | L2₹40.7 CrRejected-Finance | ₹40.7 Cr | L2 | Rejected-Finance Rejected being other than lowest |
| 3 | L3₹40.8 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹40.8 Cr | L3 | Rejected-Finance Rejected being other than lowest |
| 4 | L4₹41.2 CrRejected-Finance | ₹41.2 Cr | L4 | Rejected-Finance Rejected being other than lowest |
| 5 | L5₹42.5 CrRejected-Finance | ₹42.5 Cr | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹44.3 Cr
EMD Value
₹15 L
Closing Date
22 Dec 2020, 6:00 pmClosed
HQ Chief Engineer Pathankot Zone
HQ Chief Engineer Pathankot Zone
PROVN OF KLP ACCN INCL STP FOR DIV ENGR REGTAT MIL STN KALUCHAK JAMMU
2020_MES_335007_2
CEPZ-16/2019-20
Open Tender
Civil Works
912 days
Jammu
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE (P) Jammu
₹15 L
Yes
31 Mar 2021
12 Nov 2020
24 Dec 2020
13 Nov 2020
22 Dec 2020
12 Dec 2020
Amount
Lumpsum price worked out by the contractor for Building work as listed in Schedule 'A' Part-I.
Lumpsum price worked out by the contractor for Internal water supply as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for Internal electric supply as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for Plumbing work as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for Site Clearance and Tree cutting as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for Road, Path and culvert work as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for Compund wall, Security fencing and steel gate as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for Sewage disposal as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for CONNECTING PASSAGE 2.25M WIDE WITH FIBRE SHEET ROOFING ON MS TUBULAR TRUSS AND PCC FLOORING as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the contractor for External Electrification as listed in Schedule 'A' Part-XI.
Lumpsum price worked out by the contractor for External Water supply/ Hot water supply works as listed in Schedule 'A' Part-XII.
Lumpsum price worked out by the contractor for Lightening Protection as listed in Schedule 'A' Part-XIII.
Lumpsum price worked out by the contractor for Demolition/ dismantling as listed in Schedule 'A' Part-XIV.
INTERNAL ELECTRIFICATION :
Point wiring with 1.5 sqmm copper conductor cables (multistranded), FRLS PVC insulated , unsheathed (using colour code as per IS), 1100 Volts grade in and including concealed PVC rigid conduit of not less than 1.8mm thick heavy duty (ISI marked) of adequate size with sunk cast iron/pressed steel terminal box of adequate size with 3mm thick plastic laminated sheet top cover for one light /fan /exhaust fan point controlled by one, one way 5 Amp switch including continuous 1.5 sqmm copper conductor (multistranded using colour code) FRLS PVC insulated and unsheathed cable as earth wire connected to earth dolly complete all as specified and directed
All as per item No 16 here-in-before but for one multi pin 5 pin socket outlet 5 Amps independent.
All as per item No 16 here-in-before but for one 3 pin socket outlet 5 Amps on the same board with other switches.
Point wiring with 2.5 sqmm copper conductor cables (multistranded), FRLS PVC insulated , unsheathed (using colour code as per IS), 1100 Volts grade in and including concealed PVC rigid conduit of not less than 1.8mm thick heavy duty (ISI marked) of adequate size with sunk cast iron/pressed steel terminal box of adequate size with 3mm thick plastic laminated sheet top cover for one 3 pin socket outlet 15 Amps on independent board controlled by 16 Amp switch including continuous 2.5 sqmm copper conductor (multistranded using colour code) FRLS PVC insulated and unsheathed cable as earth wire and connected to earth dolly complete all as specified and directed.
Submain wiring with 2 run of single core, 4 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable FRLS (using colour code as per IS) with and including 4 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through PVC rigid conduit of suitable size, heavy grade (ISI marked) having thickness not less than 1.8mm (ISI marked) with and including all accessories, complete all as specified and directed. Note : Two runs of single core cable with one run of earth cable and conduit shall be measured as one run.
Submain wiring with 2 run of single core, 6 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable FRLS (using colour code as per IS) with and including 6 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through PVC rigid conduit of suitable size, heavy grade (ISI marked) having thickness not less than 1.8mm (ISI marked) with and including all accessories, complete all as specified and directed. Note : Two runs of single core cable with one run of earth cable and conduit shall be measured as one run.
Submain wiring with 2 run of single core, 10 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable FRLS (using colour code as per IS) with and including 10 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through PVC rigid conduit of suitable size, heavy grade (ISI marked) having thickness not less than 1.8mm (ISI marked) with and including all accessories, complete all as specified and directed. Note : Two runs of single core cable with one run of earth cable and conduit shall be measured as one run.
Submain wiring with 2 run of single core, 16 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable FRLS (using colour code as per IS) with and including 16 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through PVC rigid conduit of suitable size, heavy grade (ISI marked) having thickness not less than 1.8mm (ISI marked) with and including all accessories, complete all as specified and directed. Note : Two runs of single core cable with one run of earth cable and conduit shall be measured as one run.
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with and including LED lamp 1x 9 Watt complete all as specified and directed.
SPN MCB DB 6 way, sheet metal enclosures double door 240 Volts AC, 50 Hz AC complete all as specified and directed
S&F MCB SP 240 Volt, 50 Hz, 10 KA of rating 6 Amp to 32 Amp complete all as specified and directed.
S&F MCB SP 240 Volt, 50 Hz, 10 KA of rating 40 Amp complete all as specified and directed.
S&F MCB SP 240 Volt, 50 Hz, 10 KA of rating 50 Amp to 63 Amp complete all as specified and directed.
S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 0.5 Amp to 5 Amp complete all as specified and directed.
S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 10 Amp complete all as specified and directed.
S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 16 Amp complete all as specified and directed.
S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 20 Amp complete all as specified and directed.
S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 25 Amp complete all as specified and directed.
S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 32 Amp complete all as specified and directed.
S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 40 Amp complete all as specified and directed.
S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 50 Amp complete all as specified and directed.
S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 40 Amp complete all as specified and directed.
S&F MCB SPN 240 Volt, 50 Hz, 10 KA of rating 63 Amp complete all as specified and directed.
S&F MCB TPN 240 Volt, 50 Hz, 10 KA of rating 10 Amp complete all as specified and directed.
S&F MCB TPN 240 Volt, 50 Hz, 10 KA of rating 16 Amp complete all as specified and directed.
S&F MCB TPN 240 Volt, 50 Hz, 10 KA of rating 25 Amp complete all as specified and directed.
Supply and fixing VTPN DB of 4 way suitable for MCD TPN as a incoming & single phase as well as threephase SP/TP MCB as a outgoing with IP 43 protection against solids & liquid particles and 1K 09 protection against mechanical impacts. DB should be as per IS 8623 & made of high quality CRCA sheet. DB should be with insulated Busbar with 200A withstand capacity of 36 KA, shrounded neutral bar, Door earthing, corner safe. Wiresets, Neutral bar, earth bar & wire ties should come along with DB complete all as specified and directed.
All as per serial item No. 43 here-in-before but suitable for MCCB TPN as incomer complete all as specified and directed.
All as per serial item No. 43 here-in-before but suitable for MCCB TPN as incomer and 6 Nos of ways complete all as specified and directed.
M&L for MCCB 415 Volts, TPN, 16 Amps, 10 KA (Ics=50%Icu as per IEC 60947-II) with fixed thermal magnetic setting complete as specified and directed.
M&L for MCCB 415 Volts, TPN, 25 Amps, 10 KA (Ics=50%Icu as per IEC 60947-II) with fixed thermal magnetic setting complete as specified and directed.
M&L for MCCB 415 Volts, TPN, 32 Amps, 10 KA (Ics=50%Icu as per IEC 60947-II) with fixed thermal magnetic release, complete as specified and directed.
M&L for MCCB 415 Volts, TPN, 50 Amps, 10 KA (Ics=100%Icu as per IEC 60947-II) with with adjustable Thermal magnetic (80 to 100%), complete as specified and directed.
M&L for MCCB 415 Volts, TPN, 80 Amps, 16 KA (Ics=100%Icu as per IEC 60947-II) with with adjustable Thermal magnetic (80 to 100%), complete as specified and directed.
M&L for MCCB 415 Volts, TPN, 10 Amps, 16 KA (Ics=100%Icu as per IEC 60947-II) with with adjustable Thermal magnetic (80 to 100%), complete as specified and directed.
Blanking plate for MCB DB's all as specified and directed.
Supply and fixing Ceiling fan complete with accessories 230 Volt, single phase AC supply, 50 Hz, 1200mm sweep BEE 5 Star rated including connecting up with flexible PVC insulated copper cable 3 Core 23/0.0076 from ceiling rose to fan connector complete all as specified and directed.
Exhaust fan 300/305 mm sweep, heavy duty including louver shutter and connecting up with and including provision of FRLS PVC insulated multistranded copper cable of size 3 core cable 1.5 sqmm from ceiling rose to connector of fan complete all as specified and directed.
Exhaust fan 450 mm sweep, heavy duty including louver shutter and connecting up with and including provision of FRLS PVC insulated multistranded copper cable of size 3 core cable 1.5 sqmm from ceiling rose to connector of fan complete all as specified and directed.
S&F 20W surface/wall mounted batten LED luminaire, extruded aluminum housing with PC diffuser and integrated electronic driver with high efficiency long life, CRI= 80 (Minimum), PF> 0.95, luminous efficacy> 100 lumens/Watt operating voltage 140V-240V, CCT (K)> 6500, THD< 10% complete including 20W LED tube rod with all accessories internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting, complete all as specified and directed. Make:- Wipro Trim LED (LL20-281-XXX-65AL1/Philips SmartBrite (BN021C LED 20S PSU CW GR 2S) Bajaj (BCLSBAL 20W CW) or equivalent model in Makes of Group-1. Note:- Contractor shall provide 5 years warranty from the date of supply against manufacturing defects under normal working conditions .
S&F LED tube light 20W, suspended linear light solution for work space, extruded aluminum housing with high transitivity HET diffuser standalone and seamless end to end connectivity 4 feet long with PC diffuser and integrated electronic driver with high efficiency long life CRI =80, PF> 0.95, Laminar efficacy> 100 lumens/watt, CCT (k)> 5700, THD < 10%, Operating voltage 140V-240V complete including 20W tube rod and suspensions of 1.5 metre long (02 Nos) with all accessories internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed. Make:- WIPRO (LM34-251XXX-57WCG1)/BAJAJ (BRTXn 20W LED 4F WH) or equivalent model in Makes of Group-1. Note:- Contractor shall provide 5 years warranty from the date of supply against manufacturing defects under normal working conditions .
LED street light with pressure die cast aluminum housing with polycarbonate cover, finless design, dedicated peanut optics, > 100 lumen/W system efficacy, minimum 2500 system lumens, 25W system wattage (including driver), color temperature > 5700K, CRI>80, IP65 protection, IK07 rating. The potted electronic driver with THD<10%, PF>0.95, LED fitting is complete all as per OEM specified and directed. LED driver and housing is of same make as of light fitting. All type of testing for photometry, electrical and electronic parameters is done in BABI approved lab. Make:- CROMPTON (LSTS-25-CDL)/BAJAJ (BRLEP 25 W LED WH)/ WIPRO (LR02-291-XXX-57-XX) or equivalent model in Makes of Group-1. Note:- Contractor shall provide 5 years warranty from the date of supply against manufacturing defects under normal working conditions .
LED light fitting 1 x 10 Watt bulk head surface mounted luminaires in engineering plastic housing with clear prismatic diffuser CCT 6000K comlete with all accessories and including connecting up with 3 core multistranded copper condutor flexible PVC cable, operating voltage of 230 V, 50 Hz complete all as specified and directed. Make:- BAJAJ Cat part No BIBWP 10W LED/WIPRO Cat part No LW07-141-XXX-56-XX/CROMPTON Cat Part No LBH-10-CDL or equivalent in Makes of Group-I.". Note:- Contractor shall provide 5 years warranty from the date of supply against manufacturing defects under normal working conditions.
LED flame proof tube light fitting with LED tube 1x20 Watt made of aluminium alloy LM6 complete with all accessories prewired and including connecting with IP 65 protection complete all as specified and directed. Make : Cat part No EXTN1LT816/20W of Crompton or equivalent in makes of group-I.
Porch light fiting 1x18W slim design recessed round down lighter with superior light output and integral driver complete including connecting up with 3 core multistranded copper conductor flexible PVC cable of suitable size from ceiling rose to fittings all as directed. Make : Cat part No. LCDE-18-CDL or equivalent in makes of group-I.
LED Mirror light 14 Watt with lamp, never lie, linnet true reflection without shadow with all accesssories internally pre wired and including connecting up with three core multistranded flexible copper conductor cable of suitable size complete all as specified and directed. Make : Crompton cat prt No LCL-14-CDL or equivalent in makes of group-I.
Supply and fixing wall mounted fan with complete accessories 230 Volt, single phase AC supply, 50 Hz, 1200mm sweep BEE 5 Star rated including connecting up with flexible PVC insulated copper cable 3 Core 23/0.0076 from ceiling rose to fan connector complete all as specified and directed.
Supply, installation, testing and commissioning of LT feeder pillar box, factory made (Outdoor type), double door, slopy canopy made out of 3.15mm thick CRCA sheet and mounted on angle iron frame of size 65x65x6mm and 450mm high weather/dust proof, factory made, IP-54 with openable shutters on both sides front and rear having locking arrangements, totally enclosed weather proof, powder coated over a coat of primer suitable for 3 Phase, 4 wire 50 C/s, aluminium bus bar of suitable size and capacity, AC supply, electrically connected as per norms and fitted including connecting up all out going MCCB/MCB with suitable size of Alu bus bar or with stranded copper cable and fixing on suitable 'U' shaped PCC platform comprising of the following accessories complete all as specified and directed by Engr in charge : (i) Aluminium bus bar with proper colour code -04 Nos. 150 Amp Cap duly fixed on suitable size insulator, nuts bolts etc complete as per OEM recommendations. (ii) Indicator Lamp - 01 Set (Set of three) (iii) MCCB, 415 Volt, 4 pole, 100 Amps, 25 KA /37 KA rupturing capacity, Ics=100% Icu, thermal Magnetic release, with adjustable setting 80% to 100% - 01 No (Incoming) (iv) MCCB TP 25 Amp, 16 KA, 415Volt thermal Magnetic release, with adjustable setting 80% to 100% (Ics=100% Icu) - 04 Nos (Out going) (v) Digital Voltmeter 0-500 Volt with toggle switch. (v) Digital Ampmeter 0-800 Amp with toggle switch. (x) Complete wiring with suitable size copper cable, thimble etc. Note : (i) PCC for platform will be measured separately under relevant item.
SUMMER APPLIANCES
Supply, fixing & installation Reversible Hi wall AC split units indoor & outdoor suitable for Hot & Cold dual purpose air conditioner complete with cordless remote control unit, inbuilt air ioniser and plasma filter for better indoor air quality and 3 star rating and EER of capacity 2 TR with and including copper tubing of suitable size from indoor to outdoor unit and outdoor to indoor unit duly insulated complete as per OEM recommendations for efficient functioning of AC including fixing on suitable mounting brackets etc all as directed. Make: Voltas/ Hitachi/ Daikin
S&F of Voltage stablizer for automatic operation, single phase, naturally air cooler, indoor wall mounted type and designed for input variation between 170V to 270V with out put ovoltage stabilized to 230V with accuracy of +2.5%, high /low voltage protection with time delay device, voltmeter, Amps meter and of capacity 5 KVA all as directed. Make: AE/V-Guard/ Vintek
Supply, fixing, installation Reversible Hi wall AC split units indoor & outdoor suitable for Hot & Cold dual purpose air conditioner complete with cordless remote control unit, inbuilt air ioniser and plasma filter for better indoor air quality and 5 star rating and EER of capacity 1.5 TR including copper tubing of suitable size from indoor to outdoor unit and outdoor to indoor unit duly insulated complete as per OEM recommendations for efficient functioning of AC including fixing on suitable mounting brackets etc all as directed. Make: Voltas/ Hitachi/ Daikin
S&F of Voltage stablizer for automatic operations, single phase, naturally air cooler, indoor wall mounted type and designed for input variation between 170V to 270V with out put ovoltage stabilized to 230V with accuracy of +2.5%, high /low voltage protection wih time delay device, voltmeter, Amps meter and of capacity 3 KVA all as directed. Make: AE/V-Guard/ Vintek
Refrigerator, electric driven (Single phase) five star rating, having storage capacity 195 Litre/210 litres, complete with accessories all as directed. Make- whirlpool /Samsung /Godrej /LG
Refrigerator, electric driven (Single phase) five star rating , having storage capacity 310 litres, complete with accessories all as directed. Make- whirlpool /Samsung /Godrej /LG
Refrigerator, electric driven (Single phase) five star rating , having storage capacity 360 litres, complete with accessories all as directed. Make- whirlpool /Samsung /Godrej /LG
Supply , Installation, commissioning of metal top Deep freezer of 230 litre capacity having single phase 240V,50HZ, single door complete with accessories all as directed. Make : Blue Star, VOLTAS, SHRI RAM (USHA)
Supply , Installation, commissioning of metal top Deep freezer of 320 litre capacity having single phase 240V,50HZ, single door complete. Make : Blue Star, VOLTAS, SHRI RAM (USHA)
Supply, installation, commissioning of water cooler stainless steel having storage capacity 80 litre and nominal cooling capacity 40 litre per hour with suitable compressor, condensor and condensor fan motor with complete accessories and gas charged complete all as specified and as directed. Makes :- Voltas/Blue Sar/Shri Ram Usha/Sidhwal
Supply, installation, commissioning of water cooler stainless steel having storage capacity 120 litre and nominal cooling capacity 60 litre per hour with suitable compressor, condensor and condensor fan motor with complete accessories and gas charged complete all as specified and as directed. Makes :- Voltas/Blue Sar/Shri Ram Usha/Sidhwal
Supply and fixing electronic voltage stablizer for automatic operations, single phase, naturally air cooler, indoor wall mounted type and designed for input variation between 170V to 270V with out put ovoltage stabilized to 230V with accuracy of +/- 2.5%, high /low voltage protection wih time delay device , voltmeter, Amps meter and of capacity 1 KVA complete all as specified and as directed. Make: AE/V-Guard/ Vintek
Supply, installation, testing and commissioning of Desert Cooler electric driven, 1 single phase of approximate minimum size (600X810X635) mm made out of 1mm thick GI sheet for body with water tank of capacity 50 litres and with front grills and side directions grills, suitable for minimum Air delivery of 4000 cum per hour approx 450mm sweep fan size with mild steel curved blades duly painted with synthetic anti corrosive paint, fitted to body including prewired electric 4 speed switch control and one 6 Amps piano switch. Water immersed pump of minimum capacity 40 watts 1300 rpm suitable for 230 volts, 50 HZ AC supply and one 6 Amps piano switch for fan motor of minimum capacity 105 watts 1400 rpm, 230 volts, 50 HZ and water inlet pipe with brass float valve of size 15mm and outlet with brass drain plug of 20mm. The pad of three sides shall be of honeycomb type. Note :- The rate shall be inclusive of 3 core 2.5 sqmm PVC sheathed and insulated flexible copper cable chord 2 metre long with 3 pin 5 Amps top plug for power supply complete all as specified and directed. Makes:- Polar/Classic/ Avin.
EXTERNAL ELECTRIC SUPPLY
Supply, install, test and commissioning of copper wound step down transformer, outdoor type, oil immersed, naturally cooled ONAN, rated temperature rise in oil & winding 45/50 degree centigrade complete with standard fittings of capacity 500 KVA HT 11 KV, 3 phase, LT 433V, 4 wire, 50 Hz of vector group Dyn-11 with off load tap changing device on HT side to vary secondary voltage from + 5 percent to – 10 percent in steps of 2.5% including cable box on LT and HT side, first fill of new transformer oil having dielectric strength not less than 60KV, suitable mounting rails of appropriate gauge and other standard accessories all as per IS:1180 (Part 1): 2014. Note :- The rate quoted deemed to be inclusive of the following:- (a) Accessories such as oil level gauge, rating and diagram plate, monogram plate, explosive vent with diaphragm, thermometer pocket with thermometer, gun metal drain valve at bottom, Air release plug, inspection cover, lifting lugs, hooks, bi-directional plane rollers, oil temperature indicator, winding temperature indicator, silica gel breather & other standard accessories all as per IS:1180 (Part-1) : 2014 energy efficiency level 3 and losses as per clause No 7.8.1.1 of IS 1180 (Pt-I)-2014 etc. Any other item as per manufacturer recommendations for best function of transformer if required are deemed to be included in quotes rates. (b) The cost of PCC foundation required for installation of transformer shall be measured and paid separately under relevant schedule item .
Construction of platform of size 3000 x 2500 x 1200 mm for installation of transformer with brick steps on one side, chain link fencing around transformer, fencing should have hinged door and locking arrangements complete all as shown on drawing No CEPZ/C-TD/002/13 sht 2/5 complete all as specified.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendations made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded Copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :-
Aluminium bus bar with proper colour code -04 Nos, 1200 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
Indicator Lamp-01 Set (Set of three) with control wiring.
Incoming ACB 800A, 415 volt, 4 pole, Manual draw out type, 50 KA rupturing capacity, lcu=lcs,lcw ( I Sec), with adjustable settings 80% to 100 % thermal maganatic release and standard accessories as applicable.
Outgoing, MCCB, 4 Pole, 63 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics =100% Icu) - 01 No
Outgoing, MCCB, 4 Pole, 100 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% lcu) - 02 No
Outgoing, MCCB, 4 Pole, 160 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% lcu) - 02 No
Outgoing, MCCB, 4 Pole, 250 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (lcs = 100% Icu) - 02 No
Three phase digital Voltmeter with range 0 to 500 Volts.
Complete wiring with copper cable, thimble etc.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cable including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :-
Aluminium bus bar with proper colour code -04 No 150 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
Indicator Lamp-01 Set (Set of three) with control wiring.
Incoming, MCCB, 4 Pole, 100 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 01 No
Outgoing, MCCB, 3 Pole, 50 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% Icu) - 02 Nos
Outgoing MCB, SPN, 20 Amp, 230V-02 Nos
Outgoing, MCB, SPN, 6 amp, 230V, - 01 No
Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :-
Aluminium bus bar with proper colour code -04 Nos 150 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
Indicator Lamp-01 Set (Set of three) with control wiring.
Incoming, MCCB, 4 Pole, 100 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 01 No.
Outgoing, MCCB, 3 Pole, 50 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 01
Outgoing, MCCB, 3 Pole, 40 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 01 No
Outgoing, MCB, TP, 10 amp, 415V, 10 KA - 01 No
Outgoing, MCB, SPN, 20 amp, 230V, - 01 No
Outgoing, MCB, SPN, 10 amp, 230V, - 01 No
Outgoing, MCB, SPN, 6 amp, 230V, - 05 Nos
Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :
Aluminium bus bar with proper colour code -04 Nos 250 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
Indicator Lamp-01 Set (Set of three) with control wiring.
Incoming, MCCB, 4 Pole, 160 amp, 415V, 25 KA rupturing capacity, with adjustable settings 80% to 100 %, thermal Magnetic Release (Ics = 100% Icu) - 01 No
Outgoing, MCCB, 3 Pole, 50 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 03 Nos
Outgoing, MCB, TP, 16 amp, 415V, 10 KA - 01 No
Outgoing, MCB, SPN, 20 amp, 230V, - 01 No
Outgoing, MCB, SPN, 6 amp, 230V, - 01 No
Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRl recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :-
Aluminium bus bar with proper colour code -04 Nos 250 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
Indicator Lamp-01 Set (Set of three) with control wiring.
Incoming, MCCB, 4 Pole, 160 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% Icu) - 01 No
Outgoing, MCCB, 3 Pole, 100 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release(lcs = 100% lcu) - 01 No
Outgoing, MCCB, 3 Pole, 25 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% Icu) - 02 Nos
Outgoing, MCB, TP, 16 amp, 415V, 10 KA - 02 No
Outgoing, MCB, SPN, 20 amp, 230V, - 03 No
Outgoing, MCB, SPN, 6 amp, 230V, - 01 No
Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :-
Aluminium bus bar with proper colour code -04 Nos 100 A cap, duly fixed on suitable and size of insulator complete as per OEM recommendations.
Indicator Lamp-01 Set (Set of three) with control wiring.
Incoming, MCCB, 4 Pole, 63 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% Icu) - 01
Outgoing, MCCB, 3 Pole, 50 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (Ics = 100% lcu) - 01 Nos
Outgoing, MCB, TPN, 16 amp, 415V, 10 KA - 01 No ( For FP 5A)
Outgoing, MCB, SPN, 20 amp, 230V - 01 No
Outgoing, MCB, SPN, 6 amp, 230V - 08 Nos
Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking .arrangement, 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :-
Aluminium bus bar with proper colour code - 04 Nos 16 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
Indicator Lamp-01 Set (Set of three) with control wiring.
Incoming, MCB TPN, 16 amp, 415V, 10 KA - 01 No
Outgoing MCB SPN, 16 amp, 230V, - 01 No
Outgoing , MCB SPN, 6 amp, 230V, - 09 Nos
Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :-
Aluminium bus bar with proper colour code -04 Nos 80 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
Indicator Lamp-01 Set (Set of three) with control wiring.
Incoming, MCB, TPN, 50 amp, 415V, 16KA - 01 No
Outgoing, MCB, SPN, 6 amp, 230V, - 14 Nos (For 14 nos Water jet pumps. (Jet Pumps are to be provided by user)
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :-
Aluminium bus bar with proper colour code -04 Nos 400 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
Indicator Lamp-01 Set (Set of three) with control wiring.
Incoming, MCCB, 4 Pole, 250 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (Ics = 100% lcu) - 01 No
Outgoing, MCCB, 3 Pole, 100 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (lcs = 100% lcu) - 01 No (For STP)
Outgoing, MCCB, 3 Pole, 50 amp, 415V, 16 KA rupturing 80% to 100 %, Thermal Magnetic Release, (lcs = 100% lcu) - 01 No
Outgoing, MCCB, 3 Pole, 25 amp, 415V, 16 KA rupturing capacity , with adjustable settings -80% to 100 %, Thermal Magnetic Release, (Ics = 100% Icu) - 02 Nos
(g) Outgoing, MCCB, 3 Pole, 16 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (Ics = 100% Icu) - 02 Nos
Outgoing , MCB TP, 10 amp, 415V, 10 KA - 01 No
Outgoing, MCB, SPN, 20 amp, 230V, - 01 No
Outgoing, MCB, SPN, 6 amp, 230V, - 04 Nos
Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
Supply, installation, erection, commissioning and testing of Feeder Pillar out door type weather/dust proof, factory made as per CPRI recommendation made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement , 433 volts, 3 phase, 4 wire system including control wiring with suitable size of PVC insulated stranded copper conductor cable and each out going MCCB is to be connected with main bus bar through suitable size and capacity of aluminium bus bar or PVC insulated stranded copper conductor cabler including suitable size of thimbles and nut bolts etc as per manufacturer design mounted/fixed on PCC foundation and incoming and out going cable connections complete including suitable rating of CT's etc comprising of following :
Aluminium bus bar with proper colour code -04 Nos 400 A cap, duly fixed on suitable capacity and size of insulator complete as per OEM recommendations.
Indicator Lamp-01 Set (Set of three) with control wiring.
Incoming, MCCB, 4 Pole, 250 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (Ics = 100% Icu) - 01 No
Outgoing, MCCB, 3 Pole, 200 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (Ics = 100% Icu) - 01 No (For Adm Bldg)
Outgoing, MCCB, 3 Pole, 16 amp, 415V, 16 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release, (Ics = 100% Icu) - 01 No (For Trg Shed)
Outgoing, MCB, TP, 10 amp, 415V, 10 KA - 01 No
Outgoing, MCB, SPN, 20 amp, 230V, - 01 No
Outgoing, MCB, SPN, 6 amp, 230V, - 02Nos
Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
S&F Post top lantern fittings complete with all accessories LED type 20 watt including electric connection complete from terminal box to light fittings in PVC conduit of suitable size having thickness not less than 1.8mm including suitable size junction box with 2 nos 50 amps Aluminium bus bar suitable to connect UG cable and grouting 40mm dia GI pipe light grade of length not less than 30cm each for fixing post top lantern fitting complete all as specified and directed by Engr In Charge. Make: Cat Part No. LPTH20CDL of Crompton or equivalent in Make of Group-I
M&L earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edges, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth lead 32mmx6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion complete all as specified and directed.
Earthing complete with G.l earth plate electrode 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore including 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
S&F LED street light fitting complete with all accessories with rating 1X36 watt all as specified and directed by Engr-in-Charge. Make : Cat part No LTESSI36WLED of C&S or equivalent in makes of group-I (Note : GI Brackets shall be measured seperately under relevant item).
M&L for Bracket for fixing of street light fittings bent to shape, made out of 40 mm dia GI pipe medium grade not less than 1.5 mtr long fixed with two sets of MS clamps made out of flat iron of size 50mmx6 mm fabricated to shape and fixed with nuts bolts and washers & two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge. (Note : MS clamps, nuts, bolt and washer shall be measured seperately under relevant item)
S&F three core PVC insulated and FR PVC round sheathed, copper conductor 1100 volts grade cable of size 1.5 sqmm (multi stranded) complete all specified and directed by Engr-in-charge.
S&F pole mounting junction box of size 300mmx200mmx100mm fabricated out of 2mm thick MS sheet, front openable door with hinges, duly painted with aluminium paint internally and externally over a coat red oxide primer suitable to house and including 02 Nos aluminium bus bar of 63 Amps capacity mounted on suitable insulators, one No MCB SP 6A mounted on dinrail, internally wired with suitable size of copper conductor cable, provision on bottom side for cable entry holes including fixing with steel tubular poles with two Nos Fl clamps 25mmx3mm with nuts, bolts and washers complete and making connection with 1.5 sqmm copper conductor unsheathed FRLS PVC insulated 3 core from junction box to security lights fittings duly laid inside the streel tubular pole and bracket. complete all as specified. Note : 40 mm bore GI pipe light grade, MS clamps , nuts , bolts & washers and 3 core 1.5 sqmm cable, GI brackets will be measured separately.
EXTERNAL WATER SUPPLY
Supply, laying, jointing and testing of DI (Ductile iron) Pipe 150 mm bore spigot and socketed type of Class K-7 conforming to IS 8329, with inside surface of centrifugally cement mortar lined, laid in trenches / on ground suitable for & including rubber gasket (Push-on) joint and jointing material complete all as specified and directed. Note :- Excavation and earth work will be measured and paid separately under relevent items.
Ductile iron fittings confiorming to IS 9523 for spigot and socket pipes up to 150 mm bore such as bends (any type, radius and angle) tapes, any (straight, bend incresasing, decreasing or double socket etc) Tee pipes, single branch, 'Y' junction double branch, cross collers, caps and plug including push on joints complete all as specified and directed.
Construction of brick masonry valve pit of size 90cmx90cmx105cm (internal dimension of chamber) with brick work in cement mortar 1:4 including plastering internally and pointing externally as the work proceeds complete with MS sheet cover 3.15mm thick and angle iron frame 40mmX40mmX6mm with handle, locking arangement and painting with two coats of synthetic enamelled paint over a coat of red oxide primer on steel surfaces including earth work & excavation in any type of soil, disposal of surplus spoil not exceeding 50m concrete etc all as specified and shown on drawing.
Construction of brick masonry valve pit of size 105cmx105cmx105cm (internal dimension of chamber) with brick work in cement mortar 1:4 including plastering internally and pointing externally as the work proceeds complete with MS sheet cover 3.15mm thick and angle iron frame 40mmX40mmX6mm with handle , locking arangement and painting with two coats of synthetic enamelled paint over a coat of red oxide primer on steel surfaces including earth work & excavation in any type of soil, disposal of surplus spoil not exceeding 50m concrete etc all as specified and shown on drawing.
Gun metal, globe or gate valve (ISI marked), class 2 with iron wheel head, screwed both ends for 80mm bore iron pipe and fixed complete all as specified and as directed.
Suuply, Fabrication & installation of header made out of heavy duty MS pipe 400 mm dia not less than 12 mm thick and 5 mtr long duly painted and welded on both sides with MS plate having thickness not less than 12mm with suitable holes for incoming pipe 150mm dia - 01 No and 80mm dia - 05 Nos for out going pipes, The job includes welding 01 No 150mm dia MS pipe 600 mm long, heavy grade at one end and other end duly welded with MS flange having thickness not less than 10mm, duly holes drilled matching with the holes of sluice valve flange 150mm dia including sluice valve 01 No of 150mm dia conforming to IS 14846 with SS spindle and hand wheel and including 5 Nos MS pipe pieces 600mm long 80mm dia heavy grade welded at one end and other end duly welded with MS flange having thickness not less than 10mm duly holes drilled matching with the holes of sluice valve flange 80mm dia including sluice valves 04 Nos. of 80mm dia conforming to IS 14846 with SS spindle and hand wheel all as direced by Engineer in charge. The job also includes fabrication of connecting piece made out of 80mm GI pipe medium grade 600mm long duly welded MS flange having thickness not less than 10mm duly holes drilled matching with the holes of flange of 80mm dia sluice valve at one end and other end threaded for cotinuous laying of GI pipes-03 Nos. and fabrication of connecting piece made out of 50mm dia GI pipe medium grade 600mm long duly welded MS flange having thickness not less than 10mm duly holes drilled matchng with the holes of flange of 80mm dia sluice valve at one end and other end threaded for continuous laying of GI pipes -02 Nos. Notes :- (a) Header shall be placed above ground level on PCC block built in PCC (1:3:6) type C2 of size 3mx1.2mx0.8 m all as directed. (b) The rate of the PCC block is included in this item only. (c) PPR pipes shall be measured and paid seperately under relevent items
Note : Header shall be placed above ground level on PCC block of size 2m x 1.2m x 0.8m built in PCC 1:3:6, type C-2 all as directed by the Engineer in charge. Rate of PCC block shall deemed to be included in this item.
Cutting of existing DI Pipe line 150mm dia, (two cuts in position) by any means, inserting and including new DI Tee of size 150mmX150mmX150 mm dia for branch connection all as directed by Engr-in-charge. Note : CI/DI fittings, excavation and earth work, Lead joint/ Flanged joint etc shall be measured and paid seperately.
HOT WATER SUPPLY
Supply, installation and testing water heater storage type (Geyser) of capacity 25 litres, Five star rating of BEE complete, single phase 240 volts 50 Hz with copper inner tank, including necessary electrical & water connections fixed on wall with suitable nut & bolts including grouting in PCC 1:2:4 type B-I using 20mm graded crushed stone aggregate with 02 Nos of PVC flexible pipe for connection (hot & cold supply) with suitable size of nuts complete all as specified & directed..
Supply, installation, testing and commissioning of solar water heating system with ETC TECHONOLOGY of capacity 200 LPD with electric backup as per recommendations of manufacturer suitable for single phase 220 volts AC supply complete with ETC type collectors , HOT water tanks , Tank Stands etc with the following specifications :- (a) COLLECTOR ETC type with nos, size, level of vaccum transmittance of cover glass tubes, reflectance of glass tubes, absorbance of glass tubes, type of coating and reflectance of coating as recommended by manufacturer having wind resistance upto 100 km, with freezing resistance minus 20 degrees C heating up coefficent 240 degrees C having average thermal efficiency 58.76% and maximum rise in temp 53.04 deg C without night losses fixed at angle of inclination from horizontal, as per recommendations of manufacturer. (b) HOT WATER TANK : Hot water tank of 100 Itrs capacity made out of stainless steel sheet not less than 0.5mm thick duly insulated with puff insulation 50mm thick having density not less than 36 kgs having thermal conductivity 0.29m/K duly covered with PPGI cladding fixed with temperature gauge, inlet and outlet valves of suitabvle size duly installed on staging fabricated out of MS angle of appropriate size as recommended by manufacturer duly fixed properly and painted with two coats of anti corrosive paint over a coat of red oxide primer. (c) MAKE : Make of Solar system Sun Magic/Bipin industries/BORO Solar/Inter Solar NOTE:- PCC/Foundation work as recommended by the manufacturer will be included in the rate quoted for this work.
All as per srl item No 113 here in above but Solar water heating system of 300 LPD capacity with hot water tank 300 litres capacity duly insulated and PPGI cladding inciuding electric backup as per recommendations of manufacturer. NOTE (for srl item No 113 & 114) (a) MS staging, puff insulated water storage tank, Hot water and cold water pipe insulation to pipe and valves to be measured and paid separately. (b) Any other items required for sucessful operation of system is deemed to be included in the rates quoted for above items
SEWAGE TREATMENT PLANT (STP)
Supply and installation of ON LOAD change over switch 415 V in sheet metal enclosures 4 pole of capacity 125 Amps all as directed by Engineer in charge.
Supply, installation, commissioning and testing of Diesel engine driven Water cooled generating set of capacity 50 KVA, 415 volts, BHP as per manufacture recommendation, AC supply, 50 Hz, 3 phase 4 wire, 0.8 PF at NTP, speed 1500 RPM at Jammu mounted on common base frame with flexible coupling and meeting the requirement of IS-4722/BIS specification with CPCB approved acoustic enclosures fabricated out of CRCA sheets as per manufacture recommendation. Sound proofing of enclosures is done with high quality foam conforming to IS-8183 for 75 dBT 01 metre complete including PCC foundation in all respect as per norms of OEM. Make: Kirloskar Oil Engines/ Cummins/ Greaves Ltd/ Ashok Leyland/ Mahindra & Mahindra / Ruston/Cater pillar
DIESEL ENGINE: Water cooled diesel engine of adequate capacity at 1500 RPM generally in accordance with latest BIS/IS specification, 12 volts self starting including maintenance free battery of suitable capacity, charging dynamo/ alternator, air cleaner, diesel/ oil filters, complete in all respect. The engine shall be capable of taking 10% over load for one hour for every 12 hours running confirming to the environment (PROTECTION ACT 1986) (29 pf 1986) and as amended vide Gazette of India Notifications Part-II sections-III Sub Section (I) dated 12 Jul 2004.
ENGINE INSTRUMENT PANEL : All relevant information shall be displayed on a complete panel for easy monitoring of lubricant, oil pressure, battery charging, ammeter, hours meter, startin switch, etc.
FUEL TANK : In built fuel tank of adequate capacity for 12 hours running with stop cock, drain plug as per recommendation of OEM
ALTERNATOR : 50 KVA at NTP at Jammu Military Stn, 3 Phase, 50 Hz, 415 volts, AC supply, 0.3 PF at 1500 RPM, this shall be self excited screen protected and drip proof type brushless, conforming to relevant IS/BIS code as per latest manufacturing schedule.
CONTROL PANEL : The standard control panel shall be built in acoustic enclosures with the following accessories complete wired with suitable size of copper cable:- (i) MCCB of suitable capacity with over load and short circuit protection. (ii) Digital Ammeter. iii) Digital voltmeter. (iv) One set of indicating LED lamps RYB and fuses. (v) Frequency meter, RPM meter, Hour meter, Fuel level indicator. (vi) KWH meter of suitable capacity digital type for 3 phase 415 volt AC supply and for unbalanced load (vii) Water temperature gauge, oil pressure gauge. Note : The Gen set must be affixed with label meeting the following requirement (The label shall be durable and legible) (a) Name and address of the engine manufacturer. (b) Statement that this engine conforms to the environment (PROTECTION) (c) Type and approval certificate number. (d Date of manufacturing of Gen set.
Acoustic enclosure: Acoustic enclosure should be as per manifucturer recommendation. The walls of enclosures will be insulated to get 75 dba at 1 metre sound leveled as recommended by ministry of environment and forest. The enclosure shall have following provisions : (i) Fitting arrangement (ii) Point for neutral and bod earthin iii Fuel drain (iv) Lub oil drainage (v) Air breather (vi) Easy stop push button (vii) Panel meter viewinG window (viii) Canopy light as per OEM recommendations Note: (i) DG set should be sound proof as per latest policy (ii) First filling of Engine oil and Fuel etc should be arranged by contractor for testing
Designing, Installation, commissioning and testing of Non clog submersible pump with chrome steel impeller and cutter to pass 40mm-80mm size particles with suitable capacity of motor including guide wire and lifting chain, suitable size of discharge pipes from pump at collection sump No 1 to collection sump No 2 with all fittings, NRVs and suitable capacity of submersible pump starter and connected items required for smooth functioning of pump set all as directed by Engr-in-charge. Note :- The rate for this items shall deamed to be inclusive of any other items reqd for installation and proper functioning of pump sets as per ground requriment.
Design and construction RCC Sump well cum pump house 401 to 500 Cum/day of 8 metre overall depth and dia 3m internally with IL upto 4 m in M-30 design mix of required capacity including excavation in all type of soil strata, foundation concrete, container walls, bottom slab, top RCC roof slab with CI manhole covers, internal plaster and water proofing as specified including epoxy paint inside, refilling of earth and disposal of surplus earth within 50m lead including all piping connctions, valves, internal electrification, MS ladder, ventilation shaft, BB chambers with 5m of outer wall of tannk complete including test for water tightness and hydralic functioning, top roof as per zonal specification all as directed by Engr-in-charge.
Design and construction RCC raw sewage collection tank of capacity 50 KL in M-30 design mix of required capacity including excavation in all type of soil strata, foundation concrete, container walls, bottom slab, top RCC roof slab with CI manhole covers, internal plaster and water proofing as specified including epoxy paint inside, refilling of earth and disposal of surplus earth within 50m lead including all piping connctions, valves, internal electrification, MS ladder, ventilation shaft, BB chambers with 5m of outer wall of tannk complete including test for water tightness and hydralic functioning, top roof as per zonal specification all as directed by Engr-in-charge.
Preparation of new or previously treated surface and Painting lines, dashes, arrows, letters etc on road pavement (Bituminous surfaces) and the like using thermoplastic paint with 8% glass beads using special applicator machine with heating arrangement upto 160ºC with road marking paint of white or golden yellow complete all as directed by Engr-in-Charge. Make : Asian/ STP Ltd/ Automat/ 3M.
Road sign boards with legs of size 1200mmx600mm made out of 18 gauge (1.25mm) thick CRCA steel sheet duly framed in 32mm sq MS pipe of 16 gauge sheet provided with 25 mm Sq pipe hold fast. Board stove enamenaled and baked 1200 C to make it all weather resistant . Board laminated on both sides with reflective sheets, computer cut letters, sign and as directed by the Engineer in charge. Sign board to have 12mm reflective boarder all around the board supported with bolts, over a pair of legs made out of 47mm Sq MS pipe of 16 gauge sheet of length 3mtr each duly painted with black and white 1st grade synthetic enamel paint over a coal of red oxide metal primer complete all as spedified and directed. Make : Greenlite / Dark eye / 3M / Avery Dennison as approved by GE.
Providing & fixing concertina coil fencing with punched tape concertina coil of 610 mm dia, stretched to 7.00m length spring core wire (2.59mm thick) of high tensile strength of 1620N/Sq mm with tape (0.52 mm thick) hot dip galvanized up to 20 microns and weight of each coil 8.50 kg (+5%) and fixing the same on ‘Y’ shaped angle iron with horizontal RBT (Reinforced barbed tape) wire, stud tied with GI staple, GI clips to retain horizontal clip shall be @ 5 Nos per 02 spiral turns approximate 125 clips per coil incl necessary bolts complete all specified and directed
Note: The schedule of credit has been attached in tender in Pdf format and amount of credit schedule i.e. Rs 5969522.04 shall be deducted from the total amount of BOQ to arrive at the contract sum.
Saru Enterprises Pvt Ltd
FRIZO INDIA PVT LTD
Rabina Enterprises Pvt Ltd
AKM CONSTRUCTION AND ENGINEERING LLP
M/S ABDUL SALAM MIR CONSTR CO PVT. LTD
Varindera Constructions Limited
DES RAJ NAGPAL CONTRACTORS PVT.LTD
ENGINEER CONSTRUCTION PVT. LTD.
Kamladityya Construction Private Limited
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
PARDEEP ELECTRICALS AND BUILDERS PVT LTD
NITYA NAND AND SONS CONTRACTORS PVT LTD
PUSHKARRAJ CONSTRUCTION PRIVATE LIMITED
stage.html
html • 0.10 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.07 MB
Download all tender documents and submit your bid