Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹17.2 L
EMD Value
₹43,011
Closing Date
29 Jan 2024, 10:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Gulbarga Electricity Supply Company Limited
RANGANATH BABU
Tender for replacement of old weasel ACSR Conductor by LT AB Cable to improve the Transmission and Distribution Losses of 250KVA Police station DTC at Moka Village in O&M Moka Section , Reconducting of existing old aged , damaged / detoriated 4ACSR conductor/2ACSR conductor of existing LT line of 100KVA Katte Basappa Village DTC at Halkundi villages in O&M Unit 3 of RSD Gescom Ballari. of Rural Sub Division, Ballari., Under PTk Basis Poles will be supplied by GESCOM
GESCOM/2023-24/EL/WORK_INDENT28
GESCOM/2023-24/EL/WORK_INDENT28
Open
Electrical
Two Tender Document System(Two Cover)
GESCOM Executive Engineer Division Office Bellary Rural
4 documents required · 0 mandatory · 4 optional
Department Registration Details
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing work
List of works for which tenders already submitted
Banker Details
UPLOAD ALL TECHNICAL BID CRITERIA AS PER TENDER DOCUMENTS
₹500
₹43,011
16 Jan 2024
16 Jan 2024
30 Jan 2024
25 Jan 2024
Tender for replacement of old weasel ACSR Conductor by LT AB Cable to improve the Transmission and Distribution Losses of 250KVA Police station DTC at Moka Village in O&M Moka Section , Reconducting of existing old aged , damaged / detoriated 4ACSR conductor/2ACSR conductor of existing LT line of 100KVA Katte Basappa Village DTC at Halkundi villages in O&M Unit 3 of RSD Gescom Ballari. of Rural Sub Division, Ballari., Under PTk Basis Poles will be supplied by GESCOM
Erection of RCC/PSC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth
Erection of RCC/PSC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth
2811101-Guy with Complete set
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
281683-Spiral Earth Electrode
providing spiral earth electrode type earthing along with pole (without charcoal, salt etc.,
284223-Piercing connector suitable fo
Installation of Insulation piercing connector for main to street light Main : 16-95sqmm, Tap : 1.5-10sqmm(EP95)
284284-Universal hook & Bolts & nuts
Fixing of Universal Hook
284819-3x95+1x70+1x16 street light (I
Stringing of 1.1kV grade aerial bunched 3 core cable of XLPE insulation standard aluminum conductor, standard around a weather resistant black XLPE insulated AAA messenger wire 1. (3x95) (for Phase co...
284821-Three phase Distribution box f
Distribution box suitable for 6 3 phase connections
284822-Piercing connector suitable fo
Installation of Insulation piercing connector for main to service line Main : 25-95sqmm, Tap : 25-95sqmm(P3X95)
284825-Dead end clamp / Anchor clamp
Erection of Anchor Clamp - 25 to 95 Sq. mm insulated messenger with bracket
284829-Tee-connectors- KZ3 95
T-connector KZ3 95
284832-Straight joints suitable for 9
Installation of Pre-insulated straight thru joints-MJPT for 25sqmm cable
284833-End cap for 50/70 Sq.mm
End cap for 50/70 Sqmm
284837-Pre-Insulated lugs-CPTAU for 9
Installation of Pre-insulated lugs-CPTAU for 95sqmm
284838-Suspension Clamp Assembly16 to
Erection of Suspension Clamp - 25 to 95 sqmm bare messenger
284844-Pole Clamp for HT/LT AB cables
Pole Clamp-145mmx95
284845-Eye Hook (Flat Type) for fixin
289027-PVC Wire-25 Sq.mm
284105-Weasel ACSR Conductor
Releasing Of Stringing of conductor wren, squirrel, weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.
Stringing of conductor wren, squirrel, weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.
Releasing & Refixing of over head service mains (single phase / three phase) for consumer installation and street lighting and similar work (While replacing existing pole)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
self declaration certificate.doc
Others - SELF DECLARATION • 0.02 MB
section v scc.doc
Others - SCC • 0.12 MB
section ii.doc
Instructions to Tenderers • 0.14 MB
250KVA School DTC.pdf
Others - SKETCH • 1.86 MB
section iv.doc
Others - ECC • 0.09 MB
work done certificate.doc
Others - WORK DONE • 0.03 MB
ibt to bidders.docx
Instructions to Tenderers • 0.02 MB
tender booklet.doc
Others - TENDER BOOKLET • 0.12 MB
section iii.doc
Others - GCC • 0.14 MB
section vi annexures.doc
Others - ANNEXURES • 0.12 MB
section i ifb.doc
Instructions to Tenderers • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .