Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹9,400
Closing Date
14 Feb 2022, 2:45 pmClosed
OFFICE OF THE EXECUTIVE ENGINEER (SDW) VIII
OFFICE OF THE EXECUTIVE ENGINEER (SDW) VIII
SITC OF PCB based LT panel for Return sludge pump house at 5 MGD STP Najafgarh (Re-invite)
2022_DJB_216208_1
NIT NO. 18 (2021-2022) EE(SDW)VIII
Open Tender
Miscellaneous Works
Works
30 days
OFFICE OF THE EXECUTIVE ENGINEER (SDW) VIII
as per NIT conditions
2 documents required · 2 mandatory
₹500
services.sabpaisa.in
₹9,400
18 Feb 2022
5 Feb 2022
14 Feb 2022
5 Feb 2022
14 Feb 2022
5 Feb 2022
Dismantling of old panel board /starters etc. and disconnecting all the old incoming and the outgoing connection and shifting the panel /starter from the site
Supply of PCB based panel for motor and pump,power controller for upto 15 HP star delta connection (Programmable Micro Controller Base ) suitable for 15 HP ,4 nos pumpset in sheet steel enclosure MS sheet of 16/18 SWG on angle iron frame of 50 x 50 x6mm with four leg sizes 2000mmX1500mmX400mm (tentative size) wide with wiring 2.5 mm /1.5mm/1.0 or as per requirement .All the accessories should be fitted in powder coated CRC sheet cabinet ,Unit having following protection : (1) TP Thermal overload relay range 13-21 A-4 nos, (2) S/O Ampere Meter 200/5 A,Digital Type - 1 no., 3) S/O Ampere Meter 60/5 A,Digital Type - 4 no., 4)S/O Voltmeter ,Digital Type - 1 no., 5)S/o Current transformer 200/5 A ,Digital type -6 nos, 6) S/o Current transformer 60/5 A ,Digital type -12 nos, 7) SP MCB -15 Nos, 8) s/o ON/OFF push button 22.5 ,-8 nos, 9) s/o Indication lamp ,LED type -12 nos, 10) s/o MCCB of rating 200A ,triple Pole ,415v AC of breaking capacity of36 KA more with spreader link -4 nos, 11) s/o MCCB of rating 63/60/32/30A ,triple Pole ,415v AC of breaking capacity of36 KA more with spreader link -4 nos, 12) s/o MCCB of rating 63A ,triple Pole ,415v AC of breaking capacity of30KA more -4 nos, 13) TP Air break contactor 25 A ,Coil Voltage 240,-8 nos, 14)TP Air break contactor 18 A ,Coil Voltage 240,-4 nos, 15) STAR DELTA TIMER 0-20 SEC,240 V,-4 NOS, make :- skope /siemens/ABB /DJB APPROVED MAKES
S/o Copper insulation cable 10 sq.mm 3 core, Make :-Grandley/ICC /GLOSTER /DJB APPROVED MAKES
S/o Copper thimble 10 sq.mm Make :- Dowell/SAM
Fixing new base at site with the help of fastener/welding and grouting of nut bolts and including all other work as per site requirement and fixing the new LT PANEL at the newly fixed base frame by lifting the panel board and placing it at the base frame proerly and fixing it to the frame by nut bolts as requirement .Fabrication and supply of base frame made out of angle iron of suitable size for fixing above panel and suitable for making outgoing/incoming cable entries in the panel .It should be duly painted and ready with provison for installing at site .
Making the incoming connection to panel by connecting the existing cables after proper thimbling etc. including providing & fixing of consuambles as per requirement making the outgoing connection of starters to their respective pumps etc. throgh existing cables as per site requirement after relaying of the cable as required ,proper thimbling and tapping etc. including providing & fixing of material as per requrement .Making the incoming /outgoing connections of as required ,proper thimbling and tapping etc, including providing & fixing of material as per site requirement .
Testing an commissioning of the panel board first at NO LOAD and then at ON LOAD and operation as per the satisfaction of Engg-In-Charge loading unloading cartage and transportation charge for the above panel upto the site including charges of heavy labour etc.
DEEPAK ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .