| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹45.7 L+₹3.9 L (9.21%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹46.8 L+₹4.9 L (11.8%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹47.0 L+₹5.1 L (12.1%)Rejected-Finance T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹47.1 L+₹5.2 L (12.4%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Jun 2023, 6:00 pmClosed
SHRI BIJENDRA SHARMA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8535/E8
2023_MES_599125_1
8535/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VASCO
Class D Category b i
7 documents required · 7 mandatory
₹500
GE NW VASCO
₹80,000
Yes
1 Aug 2023
29 May 2023
26 Jun 2023
29 May 2023
24 Jun 2023
12 Jun 2023
29 May 2023 - 11 Jun 2023
Amount
M & L for LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade 70 Sq mm, 3½ core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete including taking down old unserviceable UG cable all as specified and as directed Note item No 01 to 07 :- (a) Excavation, Earthwork, DWC cable protection piece, PCC work for road crossing/hard standing will be measured and paid separately. (b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), new nut, bolt and washers of required size/description are deemed to include in this rate.
Ditto all as per item No1 here in before but of size 95 sqmm 3.5 core
Ditto all as per item No 1 here in before but of size 120 sqmm 3.5 core
Ditto all as per item No 1 here in befor but of size 150 sqmm 3.5 core
Ditto all as per item No 1 here in befor but of size 185 sqmm 3.5 core
Ditto all as per item No 1 here in befor but of size 240 sqmm 3.5 core
Ditto all as per item No 1 here in befor but of size 500 sqmm 3.5 core
Excavation in trenches 1.5 M wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for taking out of UG cable/ laying UG cable / errection of poles complete all as specified and as directed.
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/disintegrated rock getting out and levelling of bottom surface to required level complete all as specified and as directed.
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed.
Removing excavated material of soils from site to a distance not exc 50mtr and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and as directed.
Supply and lay Double walled corrugated pipe (DWC ) confirming to IS 14930 heavy duty 63/50 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
Supply and lay Double walled corrugated pipe (DWC ) confirming to IS 14930 heavy duty 110/95 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and as directed.
M & L for LT heat shrinkable Straight through cable Jointing kit suitable for 3.5 core 70 to 150 Sqmm aluminium cable complete all as specified and as directed.
M & L for LT heat shrinkable Straight through cable Jointing kit suitable for 3.5 core 185 to 300 Sqmm aluminium cable all as directed.
All as per item No 16 above but suitable for 3.5 core 500 Sqmm aluminium cable all as directed.
Supply and fix or laying in trenches / on wall / poles / structures in repairs GI tubing light grade for road crossing for cable protection of the following sizes including necessary suitable size MS flat fixing clamps, fixing screws complete all as directed.
100 mm dia
80 mm dia
Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheet duly powder coated and shall be CPRI approved manufactured and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, cable gland, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, copper bus bar 1000 Amps capacity duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 75x75x6mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation as per site requirement complete all as specified and directed including comprising of following
(a) MCCB 630 Amps, FP, 36 KA, 415 volts, 50Hz-01 No (b) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz-02 Nos (d) MCCB 250 Amps, FP, 25 KA, 415 volts, 50Hz-04 Nos (f) Digital Ammeter with CTs & ASS-01 set (g) Digital voltmeter with VSS-01 set (h) LED phase indication lamps RYB-01 set (j) Copper bus bar 1000 Amp Note for item No 21 : - (a) New MCCBs/ Change over switches shall be included in the quoted rates. (b) Rate for Interconnecting copper control cable along with necessary copper lugs are inclusive in the quoted rates.(c) The dimension of panel given in the schedule are approximate size only. The contractor should obtain necessary approval / layout /general arrangement for panel form Engg in Charge prior to commencement of work. (d) Cost for connecting of existing old UG cable of any size / type to new incoming / out going terminals by cutting the required length, addn/altrn and provision of necessary cable lugs, cable glands, nut, bolt and washers, etc., shall be included in the quoted rates.
Supply and fix in repair on load changeover switches, 4 pole 630 Amps in sheet steel enclosure including enclosure, necessary spreaders/cable lugs/gland/nut, bolt and washers if required complete all as specified and directed by Engr-in-charge. (Make :- L&T Cat No CO46300OSOO or equivalent HPL/Havells)
Ditto all as per item No 20 here in before but of capacity 400 A 4 pole 415 Volts.(Make :- L&T Cat No CO44000OSOO or equivalent HPL/Havells)
Ditto all as per item No 20 here in before but of capacity 320 A/250A 4 pole 415 Volts.(Make :- L&T Cat No CO32500OSOO or equivalent HPL/Havells)
Ditto all as per item No 20 here in before but of capacity 200 A 4 pole 415 Volts. (Make :- L&T Cat No CO22000OSOO or equivalent HPL/Havells)
Taking out the existing unserviceable MCCB of any description supply and fix MCCB 4 pole 415 volts with adjutable type 125 to160 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. Make :- L & T Cat No CM90634OOMO or equivalent
Taking out the existing unserviceable MCCB of any description supply and fix MCCB 4 pole 415 volts with adjutable type 200 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. Make : L & T Cat No CM90634OONO or equivalent
Taking out the existing unserviceable MCCB of any description supply and fix MCCB 4 pole 415 volts with adjutable type 250 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. Make : L & T Cat No CM9634OOPO or equivalent
Taking out the existing unserviceable MCCB of any description supply and fix MCCB 4 pole 415 volts with adjutable type 400 Amps with breaking capacity 50 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. Make : L & T Cat No CM98404OORO or equivalent
Material and labour for fault finding of LT cables of size 35 to 240 sqmm 3.5/4 core and any length with fault detective machine by thumbing method and suitable voltage and all as per manufactures instructions including providing straight through joint and additional cable of existing size suitable to match site requirement complete all as specified and as directed .
S & F in repairs of 3 pole power Contactor AC control 550 A capacity complete including fixing arrangement complete all as specified and directed. (Make L & T Model No MNX 550 Cat No CS94145 or equivalent type in Siemens / BCH)
S & F in repairs of 3 pole power Contactor AC control 225 A capacity complete including fixing arrangement complete all as specified and directed. (Make L & T Cat No CS94140 or equivalent)
S & F in repairs of 3 pole power Contactor AC control 400 A capacity complete including fixing arrangement complete all as specified and directed. (Make L & T Cat No CS94144 or Schneider cat part No LC1E400 )
S & F in repairs of 3 pole power Contactor AC control 300 A capacity complete including fixing arrangement complete all as specified and directed. (Make : L & T Cat No CS90280 or Schneider cat part No LC1E400)
S & F in repairs APFC Relays with auto set function having 6 + 1 steps 7 stage suitable for 415 Volts including necessary connections complete all as specified and directed. (Make : L & T Cat No ETACONM005R+ETACONEXP2R or equivalent in Siemens / EPCOS)
S & F in repairs APFC Relays with auto set function having 4 + 1 steps 5 stage suitable for 415 Volts including necessary connections complete all as specified and directed. (Make : L & T Cat No ETACONM005R or equivalent in Siemens / EPCOS)
S & F in repairs APFC Relays with auto set function having 3 steps 3 stage suitable for 415 Volts including necessary connections complete all as specified and directed. (Make : L & T Cat No ETACONM003R+ETACONEXP3R or equivalent in Siemens / EPCOS)
S & F in repiars MPP type Box capacitor (Resin filled) three phase heavy duty type of capacity 20 to 50 KVAR rating suitable for 440 Voltage incl necessary connections complete all as specified and directed. (Make : L & T / EPCOS / Siemens)
S & F in repairs Copper wound with CTR 400/5 A rating complete all as specified and directed.
S & F in repairs Copper wound with CTR 200/5A rating complete all as specified and directed.
S & F in repairs Indicator Lamps (LED type) showing R,Y, B phase complete all as specified and directed.
Material and labour for refilling of distilled water with electrolyte suitable for lead acid battery of different capacities complete all as specified and directed.
S & F in repairs of lead acid battery 12 Volt 180 AH complete all as specified and directed. (Make : Exide Express or equivalent)
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated 2 core stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sqmm nominal cross section in service connection/light connections in poles all as diretced
M & L for removing vegetation, grass, scrubs and bushes or any small tree branches growing in Sub station yard along fencing, around the pole, under the HT/LT transmission lines, yards or any description by mannually/mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately.
M & L for Cutting and trimming of tree branches 3 mtr all around of any size obstructing lumination of street light touching LT/HT Over head line including removing trimmed tree branches all as directed.
M & L for servicing of 11KV VCB/bus coupler at various sub stations of Hansa, dismantling, cleaning, greasing the complete VCB with attached relays, bus bar etc, insulation testing, setting the contact gap by measuring as required, reassembling the VCB and reinstalling back to its original position checking, repairing the current, circuit panel wiring, relay testing of CT's and provision of minor spares as required complete including operational testing and commissoning complete all as specified and directed. Note :- (i) New major spare parts will be measured and paid under Sch A item No 49 to 59. (ii) Cost of removing old unserviceable spares and fixing only new spare including in the quoted rate.
Supply only Closing coil 30V DC
Supply only Tripping coil 30V DC
Supply only Antipumping device 30V DC
Supply only LED type indicator lamp assembly
Supply only Vaccum Interupter for indoor VCB
Supply only spout incoming side
Supply only spout outgoing side
Supply only Connector strip 16 way
Supply only Earth Fault and over current relay of L & T Madel No MC61A 24-110V
Supply only Digital type power factor indicator meter
Supply only Digital type Voltmeter / Ammeter
M & L for carrying out primary injection test of 11 KV indoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition and proper functioning including submitting the test report complete all as specified and directed.
Dismantling old and burnt out PT unit 11000/110 volts draw out type epoxy resin cast type taking out contact with lead and bushing from the bus bar and PT, replacing by new one of same model suitable for 11 KV /110 V grade PT unit and re-installation and testing on completion complete all as specified and directed.
Dismantling old and unserviceable power pack unit 230 volts AC input and 30 volts DC out put for VCB Panel from the site, replacement of unserviceable burnt out transformer, servicing, replacement of minor spares if required incl testing on installation complete all as specified and directed.
S & F in repairs for epoxy insulator suitable for 11 KV reel type inside HT feeder pillar box outdoor type including replacement of new nut, bolt and washer on bus bar and base complete all as specified and directed.
S & F in repairs insulating rubber mat ISI marked of size 1 m x 2 m x19mm suitable for 11 KV at shimulater and ADR
M & L for EHV grade insulating transformer oil. Make :- Power Oil.
Filteration of insulating oil with high pressure vaccum filteration plant, after filtration attains BDV upto 60 KV for Transformer, OCB and MOCB complete all as specified and as directed.
S & F in repairs strip type heater 200 watt approx 4"/6" in length complete all as specified and directed.
M & L for preparation of old cement coated surface, cleaning the surface of the RCC pole (HT) 11 Mtr long in 1/2/4 pole structures above the ground level including coping area with 2 coats of ACC exterior Emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole, numbers/letters in white colour all as directed.
M & L for taking out the MS duct cover from the cable duct chamber disconnecting the haphazardly laid serviceable HT UG cable of 3 core of 70 to 150 Sq mm from VCB/Any description taking out from cable trenches / ducts and straighten and laying in proper layers including provn of new identification tags for each cables and connecting back to its original position including cleaning the cable ducts complete all as specified and directed.
S & F in repairs for Breather unit with superior quality blue colour silica jel, to maintain the exact value of grade for transformer of capacity 100 KVA to 150 KVA, including taking down unserviceable complete all as specified.
All as per item No 70 above but 200 KVA to 250 KVA Transformer
All as per item No 70 above but 315 to 400 KVA Transformer
All as per item No 70 above but 500 KVA Transformer
All as per item No 70 above but 750 KVA Transformer
S & F in repairs HV insulator with studs nut & washers suitable for 11 KV HV side of transformer 100 KVA to 150 KVA
All as per item No 75 above but 200 KVA to 250 KVA Transformer
All as per item No 75 above but 315 to 400 KVA Transformer
All as per item No 75 above but 500 KVA Transformer
All as per item No 75 above but 750 KVA Transformer
S&F in repairs LV insulator with studs nut & washers suitable for11 KV/433V LV side of transformer of Capacity 100 KVA to 150 KVA complete all as specified and directed.
All as per item No 80 above but 200 KVA to 250 KVA Transformer
All as per item No 80 above but 315 to 400 KVA Transformer
All as per item No 80 above but 500 KVA Transformer
All as per item No 80 above but 750 KVA Transformer
Servicing and repairing / carrying out maintenance of 11KV/433V step down indoor / outdoor type transformer including the following works for 100 to 750 KVA capacity all as directed :-(a) Removing from platform and disconnecting electrical connection from HT and LT side including transporting to work shop. (b) Dismantling the transformer, drain out transformer oil, lift the cover and coil assembly, keep up the assembly in heat oven upto the preparation of inside chambers by cleaning inside, scraping complete all around old parts of the transformer. (c) M & L for two coats of oil resistance painting internal (inside transformer) over a coat of red oxide primer and painting the outer side of the transformer by using spray paint complete with one coat incl preparation of old surfaces complete. (d) Cleaning the core laminations assembly by oil complete, removing the carbon sediments / dust in the coil and core gently without making any damage to coil and core
.(e) Re-assembling all dismantled parts including provision of new gasket, nut, bolts, refilling with transformer oil and transporting back to original location including electric connection testing and commissioning complete. Note for item No 74 :- i). Oil filtration & supply of new oil will be measured and separatelyunder relevent item of this Schedule. All petty parts including nut, bolts, steel / rubber gasket minor weldings are deemed to be included in the quoted rate.iii). The rate for transport and lifting of transformer by crane should be deemed to include in the rate quoted.
M & L in repairs for rewinding of transformer 11 KV / 440 Volts of capacity step down out door / indoor type of 100 KVA to 750 KVA, including dismantling, transport to workshop, opening the body assy, drain out the oil, removing the core coil assembly from transformer remove the weak / burnt out unserviceable HT / LT winding assembly rewinding with correct gauge super enamelled copper wire of suitable class including drying, baking etc complete re-assembling the primary and secondary coil in core, re-assembling the transformer complete refill with transformer oil, installation and commissioning in the existing position complete and all as specified and directed. (Note : Each winding of HV / LV limb side will be measured separately and paid individually)
Supply and fill new silica jel, superior quality in the breather unit of transformer including taking out the old unserviceable one all as directed
Taking out the old HT 11 KV UG serviceable cable of 3 core 95/120 Sq mm from trenches/ floors/ walls and relaying/diversion/jointing the same in the new trenches/new location as directed and connecting all as directed
M & L for painting of HT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun all as directed.
S & F of cubicle type CPRI approved HT feeder piller box factory made, totally enclosed, dust & vermin proof (protection class IP 54), (front opening) with suitable aluminium bus bar of 11 KV capacity proper locking arrangement made of MS angle iron frame size of 40mmx40mmx6mm and CRCA sheet of 3.15 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide primer. of size not less then 0.8x0.8x0.8 Mtr. complete all as specified as directed by Engr-in-Charge. The cost of the welding or fixing with existing HT panel and removing the old is deemed to be included in the quoted rate of above item.
Carry out foult finding of 11 KV HT under ground cable of length up to 1.5 KM in case of cable foult such as short circuit/burn out/earth foult etc including carryout necessary hypot test by injection high voltage up to 50 KV complete all as specified and as directed.
S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm.
Ditto all as per item No 81 here in before but of size 3 core 120 to 185 sqmm
M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard for laying all as directed and specified.
OM SAI ELECTRICALS
sapna enterprises
U k Enterprises
Sai Supreme Constructions
star freeze service
MARINE ELECTRICAL AGENCIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .