| 1 | L1₹32.0 LAccepted-AOC SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.4 L+₹4.2 L (12.6%)Rejected-Finance | L2 | Rejected-Finance NOT ADMITTED BEING L2 | |
| 3 | L3₹37.8 L+₹4.7 L (14.0%)Rejected-Finance | L3 | Rejected-Finance NOT ADMITTED BEING L3 | |
| 4 | L4₹38.1 L+₹4.9 L (14.8%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L4 | Rejected-Finance NOT ADMITTED BEING L4 | |
| 5 | L5₹38.9 L+₹5.7 L (17.2%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L5 | Rejected-Finance NOT ADMITTED BEING L5 |
| Sl No | Description | Qty | Unit | somnath engineering corporation L7 | Shri Krishna Trading Corporation L2 | ENJOY L1 | Sneha Aircool L8 | D.N.PATIL L3 | pk Enterprises L5 | cooltech engineering services L4 | Sagar Electricals L10 | K A ELECTRIC CO L6 | BALAJI TRADERS L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Notes : - (i) The is at Serial No.121 of TPP 2025-26 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. | |||||||||||||
| 1.01M&L for Servicing / Preventive maintenance of the following equipments of different capacities by carrying out regular maintenance such as checking of cooling coils, condensers, electric motors of different types and compressors and other parts, cleaning, washing with suitable cleaning agents/chemicals using vacuum cleaner, Jet spray servicing, replacement of rubber wheels, bolts & nuts, screws check nuts, PVC sleeves and thimbles, etc and other parts as required, checking all electrical parts and electrical wiring etc, tightening of electrical connections, greasing of electric motors, checking of gas pressure and gas charging to the desired pressure to ensure serviceability regularily through out the contract period complete all as specified and as directed:- | |||||||||||||
| 1.02 | 1.5/2.0/3.0 ton capacity split type AC | 398 | Each | 977 ₹3,88,846 | 950 ₹3,78,100 | 900 ₹3,58,200 | 1,200 ₹4,77,600 | 800 ₹3,18,400 Lowest | 907 ₹3,60,986 | 1,200 ₹4,77,600 | 1,051 ₹4,18,298 | 900 ₹3,58,200 | 1,010 ₹4,01,980 |
| 1.03 | Water cooler of any capacity | 184 | Each | 783 ₹1,44,072 | 700 ₹1,28,800 | 150 ₹27,600 Lowest | 500 ₹92,000 | 450 ₹82,800 | 744 ₹1,36,896 | 350 ₹64,400 | 844 ₹1,55,296 | 750 ₹1,38,000 | 810 ₹1,49,040 |
| 1.04 | Refrigerator capacity 165 to 310 Ltr | 40 | Each | 899 ₹35,960 | 280 ₹11,200 | 150 ₹6,000 | 140 ₹5,600 Lowest | 160 ₹6,400 | 845 ₹33,800 | 400 ₹16,000 | 951 ₹38,040 | 900 ₹36,000 | 923 ₹36,920 |
| 1.05 | Defumidifier upto 2500 Cumf | 9 | Each | 1,062 ₹9,558 | 600 ₹5,400 | 450 ₹4,050 Lowest | 750 ₹6,750 | 850 ₹7,650 | 1,030 ₹9,270 | 800 ₹7,200 | 1,120 ₹10,080 | 1,054 ₹9,486 | 1,101 ₹9,909 |
| 1.06 | Cassette AC upto 3TR | 4 | Each | 1,157 ₹4,628 | 2,000 ₹8,000 | 1,200 ₹4,800 | 1,500 ₹6,000 | 1,350 ₹5,400 | 1,144 ₹4,576 Lowest | 1,500 ₹6,000 | 1,228 ₹4,912 | 1,160 ₹4,640 | 1,207 ₹4,828 |
| 1.07 | Deep freezer and ice making machine | 5 | Each | 1,230 ₹6,150 | 400 ₹2,000 | 280 ₹1,400 Lowest | 1,500 ₹7,500 | 1,800 ₹9,000 | 1,264 ₹6,320 | 300 ₹1,500 | 1,306 ₹6,530 | 1,310 ₹6,550 | 1,283 ₹6,415 |
| 1.08 | Taking out sealed/ old burnt compressor of split type AC 1.5 ton of approved make and S&F new sealed compressor reciprocating type, suitable for 1.5 Ton capacity AC and connecting up suction and discharging pipe lines with gas welding including testing and commissioning complete all as specified and as directed. | 6 | Each Job | 12,168 ₹73,008 | 10,850 ₹65,100 | 9,500 ₹57,000 Lowest | 12,000 ₹72,000 | 9,500 ₹57,000 Lowest | 10,500 ₹63,000 | 11,500 ₹69,000 | 13,430 ₹80,580 | 11,600 ₹69,600 | 12,731 ₹76,386 |
| 1.09 | All as per BoQ Serial Item No. 1.08 above but split type AC 2.0 Ton capacity complete all as specified and as directed. | 3 | Each Job | 13,919 ₹41,757 | 12,500 ₹37,500 | 9,800 ₹29,400 | 12,500 ₹37,500 | 1,200 ₹3,600 Lowest | 11,200 ₹33,600 | 12,500 ₹37,500 | 15,542 ₹46,626 | 13,000 ₹39,000 | 14,777 ₹44,331 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
22 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
MAINTENANCE OF SUMMER APPLIANCES INCLUDING REPLACEMENT OF DEFECTIVE SPARES AND ALLIED WORKS OF SUMMER APPLIANCES AT NAVAL STATION KARANJA UNDER AGE EM II GE (NW) KARANJA
2025_MES_724076_1
8215/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NW KARANJA
D and above b i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹80,000
Yes
2 Dec 2025
1 Aug 2025
25 Aug 2025
1 Aug 2025
22 Aug 2025
15 Aug 2025
Amount
Notes : - (i) The is at Serial No.121 of TPP 2025-26 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department.
M&L for Servicing / Preventive maintenance of the following equipments of different capacities by carrying out regular maintenance such as checking of cooling coils, condensers, electric motors of different types and compressors and other parts, cleaning, washing with suitable cleaning agents/chemicals using vacuum cleaner, Jet spray servicing, replacement of rubber wheels, bolts & nuts, screws check nuts, PVC sleeves and thimbles, etc and other parts as required, checking all electrical parts and electrical wiring etc, tightening of electrical connections, greasing of electric motors, checking of gas pressure and gas charging to the desired pressure to ensure serviceability regularily through out the contract period complete all as specified and as directed:-
1.5/2.0/3.0 ton capacity split type AC
Water cooler of any capacity
Refrigerator capacity 165 to 310 Ltr
Defumidifier upto 2500 Cumf
Cassette AC upto 3TR
Deep freezer and ice making machine
Taking out sealed/ old burnt compressor of split type AC 1.5 ton of approved make and S&F new sealed compressor reciprocating type, suitable for 1.5 Ton capacity AC and connecting up suction and discharging pipe lines with gas welding including testing and commissioning complete all as specified and as directed.
All as per BoQ Serial Item No. 1.08 above but split type AC 2.0 Ton capacity complete all as specified and as directed.
Taking down split type AC 1.5 Ton and removing rotary type sealed compressor and S&F new sealed rotary type compressor and connecting discharging pipe line with gas welding and refixing the repaired AC in its original position complete all as specified and as directed.
All as per BoQ Serial Item No. 1.10 above but split AC 2.0 ton capacity complete all as specified and as directed.
S&F in replacement copper cooling coil assembly for 1.5 ton air conditioner including testing and commissioning complete all as specified and as directed.
S&F in replacement copper cooling coil assembly for 2.0 ton air conditioner including testing and commissioning complete all as specified and as directed.
S&F in replacement condenser coil assembly suitable for 1.5 ton air conditioner including testing and commissioning complete all as specified and as directed.
S&F in replacement condenser coil assembly suitable for 2.0 ton air conditioner including testing and commissioning complete all as specified and as directed. NOTE : (for BoQ Serial Item No. 1.08 to 1.15) :- (a) Contractor will provide Guarantee for at least one year for replaced compressor unit. Compressor should be sealed with original manufacturers packing all as approved by Engr -In -Charge. (b) Gas charging will be measured and paid separately.
S&F in replacement Running capacitor, 36 mfd, 3 pole & 2 pole suitable for 1.5 ton window / split type air conditioner complete all as specified and as directed.
S&F in replacement Running capacitor 45 mfd, 3 pole & 2 pole suitable for 2.0 ton window / split type air conditioner complete all as specified and as directed.
S&F in replacement starting capacitor 100 to 120 mfd suitable for 1.5 ton window / split type air conditioner complete all as specified and as directed.
S&F in replacement starting capacitor 100 to 150 mfd suitable for 2.0 ton capacity window / split type air conditioners complete all as specified and as directed.
S&F in replacement starting relay suitable for 1.5 Ton / 2.0 Ton / 3.0 Ton of Split / Window type AC complete all as specified and as directed.
S&F in replacement thermostat switch for window / Split type Air conditioner of 1.5 / 2.0 / 3.0 Ton capacity complete all as specified and as directed.
M&L for gas charging R-22 in split type AC 1.5 / 2.0 / 3.0 ton capacity of approved make and type including pressure testing, leakage, vaccumising, rectification, testing and commissioning complete all as specified and as directed.
M&L for gas charging R-32 in window type split type AC 1.5 / 2.0 / 3.0 ton capacity of approved make and type including pressure testing, leakage, vaccumising, rectification, testing and commissioning complete all as specified and as directed.
S&F in replacement electric wiring kit (PCB) suitable for 1.5 ton / 2.0 ton Split type air conditioner invertor type AC (indoor unit and outdoor unit) including testing and commissioning complete all as specified and as directed. Note: New PCB shall be as per the existing one.
M&L for Shifting of Split type Air Conditioner of any type and make, up to 2 TR from existing location to other location and installing indoor and outdoor units with & including provision of necessary brackets (L type) clamps, GI nuts, bolts and washers etc for fixing of indoor / outdoor units and including topping up of refrigerant gas and Nitrogen pressure test to find out leakage, commissioning and testing and making good disturbed surface complete all as specified & directed. Note : PVC pipe for protection, drain pipe, control cable, extra copper tubing of any size for suction / discharge will be measured and paid separately.
M&L for Shifting of Window type Air Conditioner of any type and make, up to 2 TR from existing location to other location and installing, commissioning and testing including making opening of required size in walls or existing windows of any type, provision of necessary brackets, clamps, GI nuts, bolts and washers etc for fixing of AC and making good disturbed surface of walls and windows complete all as specified & directed. Note : PVC drain pipe , control cable where required will be measured and paid separately.
S&F in replacement electric wiring kit (PCB) suitable for 1.5 ton / 2.0 ton Window type air conditioner of any make and type complete all as specified and as directed. Note: New PCB shall be as per the existing one.
Supply in replacement Remote assembly cordless as per existing make and size window/split type AC's as per existing AC make complete all as specified and as directed.
Taking down corroded body base tray etc of Split type AC of 1.5 Ton / 2 Ton capacity and S&F body base tray made out of 18 SWG mild steel and other portion of mild steel sheet of 20 SWG including motor mounting frame fix with nuts and bolts of suitable size and including painting with one coat of black enamel paint and necessary insulation complete all as specified and as directed. Note :- Unit rate quoted shall also deemed to include for reassembling.
S&F in replacement fan blade of motor for window type AC of capacity 1.0 ton / 1.5 ton / 2.0 ton complete all as specified and as directed.
S&F in replacement blower fan motor for 1.0 ton / 1.5 ton / 2.0 ton split air conditioners including testing complete all as specified and as directed.
S&F in replacement blower drum suitable for window/split type AC of capacity 1.0 ton / 1.5 ton / 2.0 ton complete all as specified and as directed. Note: Blower drum shall be as per the existing one.
S&F in replacement blower motor capacitor 10 mfd suitable for 1.5 ton split type air conditioner complete all as specified and as directed.
S&F in replacement blower motor capacitor 15 mfd suitable for 2.0 / 3.0 ton split type air conditioner complete all as specified and as directed.
S&F in replacement copper suction pipe line of size 1/2" dia and other all as per manufacturers recommendation with including cutting, brazing work and insulation including fittings required at site complete all as specified and as directed.
S&F in replacement copper suction pipe line of size 1/4" dia and other all as per manufacturers recommendation with including cutting, brazing work and insulation including fittings required at site complete all as specified and as directed.
S&F in replacement cable PVC insulated PVC unsheathed, multistranded, 1100 volts grade, 4 core, 2.5 Sq mm with flexible copper conductor suitable for Split type AC and Window type AC complete all as specified and as directed.
S&F in replacement PVC pipe of suitable size, heavy duty for drain out of condensing water of split type air conditioner including cutting of floors or making hole in wall and making good the disturbed portion after laying pipe etc to match the existing surface with existing specifications complete all as specified and as directed.
S&F in replacement synthetic air filter suitable for split/window type air conditioner any capacity complete all as specified and as directed
M&L for flushing out nitrogen gas from condensing coil of AC 1.5 Ton capacity (Window/split) and repairs of leaking place by gas welding & making it leak free and recharging of refrigerant (R-22 & R-32) complete all as specified and as directed. NOTE: Refrigerant shall be measured and paid seperately.
M&L for flushing out nitrogen gas from condensing coil AC 2.0Ton (window/split) capacity complete and repairs of leaking place by gas welding & making it leak free and recharging of refrigerant (R-22 & R-32) complete all as specified and as directed. NOTE: Refrigerant shall be measured and paid seperately.
S&F in replacement capillary tube for Spilt type AC including brazing and connecting with existing system complete all as specified and as directed.
S&F in replacement wiring kit for Window/split AC of any capacity comprising of copper conductor cables for connections of assembly, complete all as specified and as directed.
M&L for dismantling the indoor and outdoor units of Air conditioner Window/Split type completely, transporting to Workshop for carrying out repairs, transporting back to the site, reinstalling the same on the new /existing location including testing and commissioning complete all as specified and as directed. Note : (i)Spare replaced during the proces of repair shall be measured and paid separately. (ii) Rates include the cost of dismantling and transporting the AC to workshop and labour element for carrying out repairs. (iii) The decision of Engr -in -Charge shall be final and binding on whether machine is required to be sent to workshop for repair or not.
All as per BoQ Serial Item No. 1.44 above but for water cooler of any capacity.
All as per BoQ Serial Item No. 1.44 above but for refrigerator/ deep freezer of any capacity.
S&F in replacement wall mounting type AC timer having Delay Time Facility, Auto & manual switch suitable for window/splits type AC of capacity 1.5/2 Ton capacity, operating on AC input Supply 230VAC +/- 15 %, 50Hz., Output: 230V, 25 Amp. Separate for 2 A/Cs having Protections for Over voltage (OV): Cutoff 270 V & Cut in 260 V Under voltage (UV): Cutoff 160 V & Cut in 170 V working for 24 Hours timer in 4 to 8 hours time intervals including testing and commissioning complete all as specified and as directed.
S&F in replacement 3 way backlite connector of capacity 20Amps for AC (Window/Split) complete all as specified and as directed.
Removing old unserviceable 2-3 way refrigerant control valve from split air conditioner outdoor unit after evacuating of refrigrant gas and S&F 2-3 way valve suitable for split type ACs of capacity upto 2 TR and testing complete all as specified and directed.
S&F in replacement insulation (closed cell elastomeric insulation in tubing) over copper tubing wherever required using approved material as per manufacturers recommendation complete all as specified and directed.
S&F in replacement of Indoor cabinet for split type AC of any make and any capacity or as per sample complete all as specified and as directed.
M&L for Servicing, cleaning of Solar water heater system by dismantling inlet and outlet connection, washing with suitable cleaning agent castic soda, arresting leakage and refixing the same after replacement of bush, nut, bolts,washers, painting of rusted surfaces if any making serviceable to desired satisfaction level complete all as specified and as directed.
Taking down sealed compressor of water cooler of approved make of capacity 40/80 ltrs and S&F company repaired sealed unit (Make :CAJ 3612 or AE 4440 of M/s Kirloskar or equivalent as approved) and connecting up suction and discharge copper pipe with gas welding pressure testing of leakage rectification, vaccumising and charging the refrigerant gas including testing & commissioning complete all as specified and as directed.
All as per BoQ Serial Item No. 1.53 above but capacity 60/120 ltrs complete all as specified and as directed. Make : BPK KCE 461 of M/s Kirloskar or equivalent as approved by GE
S&F in replacement starting capacitor 40/60 mfd complete all as specified and as directed.
S&F in replacement starting capacitor 80 /100 mfd complete all as specified and as directed.
S&F in replacement thermostatic switch for water cooler complete all as specified and as directed.
S&F in replacement of condenser fan motor 1 / 35 HP 230 volt AC single phase suitable for water cooler complete all as specified and as directed.
All as per BoQ Serial Item No. 1.58 above but 1/83 HP complete all as specified and as directed.
S&F in replacement relay for water cooler of capacity 40/80 litres and 60/120 litres capacity all as specified and as directed.
S&F in replacement of fan blade suitable for existing water cooler of 180 liter capacity, approved make and type complete all as specified and as directed.
S&F in replacement push cock/lifting cock of 15 mm dia chromium plated suitable for water cooler of capacity 40/80 litres & 60/120 litres complete all as specified and as directed.
M&L for detecting the gas leakage, rectifying the defects, vacumizing and charging fresh refrigerant gas and commissioing and testing the water cooler of capacity upto 60/120 litre capacity complete all as specified and as directed.
S&F in replacement water tray, stainless steel grade SS 304 of 40 /80 ltr capacity complete all as specified and as directed.
All as per BoQ Serial Item No. 1.64 above but capacity 60/120 Ltrs complete all as specified and as directed.
S&F in repairs rubber packing and hinges of top cover of water cooler of any make and capacity complete all as specified and as directed.
S&F in replacement 15 mm dia brass float valve complete all as specified and as directed.
S&F in replacement over load protector for water cooler of any capacity complete all as specified and as directed.
S&F in replacement PVC connection with brass nuts & washers at both ends of length not exceeding 60 cm for water connection of water coolers complete all as specified and as directed.
S&F in replacement suitable size PVC drain pipe flexible heavy duty with necessary saddles and fitting for drain out water from water cooler complete all as specified and as directed.
M&L for Flushing out the nitrogen gas from condensing coil Water cooler of capacity 150/150, 120/60 and 80/40 ltrs and repairs of leakage by gas welding and recharging of refrigerant complete all as specified and as directed. NOTE:Refrigerant shall be measured and paid seperately.
Taking down sealed compressor of 165 Ltr/175 ltrs capacity of refrigerator of approved make and type and S&F hermetically sealed unit compressor of same size, type and capacity, connecting sealed unit and discharge pipe with gas welding and soldering rod including testing and commissioning complete all as specified and as directed.
All as per BoQ Serial Item No. 1.72 above but 286/300/310 ltr capacity complete all specified and as directed.
S&F in replacement thermostat switch for refrigerator of any capacity complete all as specified and as directed.
S&F in replacement over load relay/protector suitable for high / low speed refrigerators of unit of compressor 165 /230 /286 /300 / 310 Ltr capacity of refrigerator complete all as specified and as directed.
S&F in replacement lamp 15 watt or any watt screw /pin type suitable for any capacity refrigerator complete all as specified and as directed.
M&L for charging of refrigerator refrigerant gas R-134a/ R-410a suitable gas after vaccumising / pressure and leaking including flushing the system in the refrigerator of any make of 165 Litre Cap including testing and commissioning complete all as specified and as directed.
All as per BoQ Serial Item No. 1.77 above but 230 / 286 / 300 /310 Ltr capacity complete all specified and as directed.
S&F in replacement magnetic gasket for refrigerator of 165/175/286 /300 /310 litres capacity complete all as specified and as directed.
S&F in replacement relay for refrigerator of capacity 165 to 310 litres complete all as specified and as directed.
S&F in replacement freezer chamber of existing make & size for upto 165 to 195 Ltr capacity refrigerator direct cool complete all as specified and as directed.
S&F in replacement freezer chamber of existing make & size for refrigerator frost free double door incl heater, blower etc for 285 to 310 litres capacity complete all as specified and as directed.
M&L in replacement of unservicable condenser for refrigerator as per existing make & any capacity, complete all as specified and directed.
S&F in replacement of filter dyer for refrigerator of capacity 165/180/190/280 to 310/320 Ltrs complete all as specified and as directed.
Taking down defective/unserviceable dehumidifier of existing capacity and existing make, transporting to maintenance yard, collecting repaired dehumidifier of same make and transporting back to site, refixing at original position including testing and commissioning complete all as specified and as directed.
M&L for replacement of water purifier filter kit including repair/ replacement of defective parts such as filters, solenoide valve, pump, switch of machine complete all as specified and as directed.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA with over load protection and high voltage Cut-off ensuring protection complete all as specified and directed.
S&F in replacement powder coated iron stand for supporting the outer unit set of two of split air conditioning including all accessories required for fitting/hanging the stand on the wall complete all as specified and directed.
M&L in replacement sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) drawing in and including 20 mm dia PVC Caping Casing Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4.0 Sq mm as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
S&F in replacement sheet metal enclosure SPN with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 10 KA C series complete all as specified and as directed.
Shri Krishna Trading Corporation (BID ID -3401411)
D.N.PATIL (BID ID -3402367)
cooltech engineering services (BID ID -3402852)
pk Enterprises (BID ID -3402675)
K A ELECTRIC CO (BID ID -3402216)
somnath engineering corporation (BID ID -3401376)
Sneha Aircool (BID ID -3402291)
BALAJI TRADERS (BID ID -3402809)
Sagar Electricals (BID ID -3402899)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .