Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹49.6 L+₹3.7 L (8.01%)Accepted-Finance | L2 | Accepted-Finance ok | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in C(i) category |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
10 Oct 2023, 6:00 pmClosed
GE AF LOHEGAON
GE AF LOHEGAON LOHEGAON PUNE-411032
SPECIAL REPAIR TO CERTAIN AC PLANTS UNDER GE (AF) LOHEGAON AT AIR FORCE STATION PUNE
2023_MES_618605_1
8746
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AFS PUNE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹90,000
Yes
7 Nov 2023
13 Sept 2023
17 Oct 2023
13 Sept 2023
10 Oct 2023
27 Sept 2023
Amount
Supply installation & testing of HW air cooled split type 5 Star rated Inverter Air Conditioner 2.0 TR capacity having inverter compressor Hidden display, Comfort sleep, 5 Sensors, 100% copper Indoor & outdoor, installation kit including extra length of copper piping as per site requirement, connection eclect cord, drain water pipe and core cutting in stone masonary wall for passing of refrigerant piping & cables etc and making good to the disturbed surface matching to existing specification outdoor unit mounting bracket with fasteners complete all as specified and directed.
Supply installation & testing of HW air cooled split type 5 Star rated Inverter Air Conditioner 1.0 TR capacity having inverter compressor Hidden display, Comfort sleep, 5 Sensors, 100% copper Indoor & outdoor, installation kit including extra length of copper piping as per site requirement, connection eclect cord, drain water pipe and core cutting in stone masonary wall for passing of refrigerant piping & cables etc and making good to the disturbed surface matching to existing specification outdoor unit mounting bracket with fasteners complete all as specified and directed.
M&L for taking out the existing unserviceable split/window type AC any capacity & deposit to E/M store yard for further disposal , including making good to the disturbed surface matching to existing specifications complete all as specified and directed.
M&L for Sheet metel enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volt complete all as specified and directed.
M&L for sub main wiring with two runs of single core 4.0 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping complete all as specified and directed.
M&L for taking out carefully damaged ducting along with any type of insulation including all accessories complete all as specified and directed.
Supply assembly and erection of GI sheet with C S cleat rectangular/square duct made out of L shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints ect complete of thickness 22 gauge all as specified and including with required scaffolding work to install the ducts at site complete all as specified and directed. Note :-(i) for measurement only the final finished area in Sqm shall be measured. (ii) Vanes, splitters, GI frames for joints, flanges, access doors etc shall not be measured separately. These shall be treated as part of duct work. (iii) only external angle Iron/C channel for duct support shall be measured and paid separatly. (iv) cost of making good the disturbed surfaces to walls by providing cement mortar is deemed to be inclusive of quoted rate.
Ditto all as per Ser Item No 7.00 above but 20 gauge galvanized sheet steel complete all as specified and directed.
M&L for duct thermal insulation class O nitrile rubber based thermal insulation 19 mm thick with treated woven glass fibre covering of 0.18mm thick, density of 200+20 GSM, Tensile strength 275+-25 Kg/mm for exposed to sun/outdoor/indoor application (green colour) including fixing with adhesive which is specifically formulated for duct insulation which shall be free from benzene and joints shall be fixed with glass cloth foil based tape with self adhesive ability to ensure 100% leak proof complete all as specified and directed.
Supply, installation, testing and commissioning of site fabricated MS channel / angle structure work for support to duct including painting, fasteners etc & including excavation for erection of MS Channel, foundation etc all as specified and directed.
Maruti Abhiyantriki
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .