Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹5.6 L+₹1,268 (0.23%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹5.6 L+₹5,028 (0.90%)Rejected-AOC | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹5.9 L+₹34,218.60 (6.13%)Rejected-AOC | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | L5₹6.4 L+₹85,133 (15.3%)Rejected-AOC N A | FARIDABAD | HARYANA | 121004 | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹7.1 L
EMD Value
₹14,200
Closing Date
28 Mar 2024, 6:00 pmClosed
GE EM RR HOSPITAL, DELHI CANTT 10
GE EM RR HOSPITAL, RAO TULA RAM MARG, DELHI CANTT 10
PROVN OF SHED NEAR PATIENT WAITING AREA VASTIBULAR LAB AT AHRR UNDER GE EM RR HOSPITAL, DELHI CANTT 10
2024_MES_644427_1
GE/H-50/2023-24
Open Tender
Civil Works
Item Rate
120 days
DELHI CANTT 10
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EM RR HOSPITAL
₹14,200
Yes
4 Jun 2024
28 Feb 2024
30 Mar 2024
28 Feb 2024
28 Mar 2024
14 Mar 2024
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified.
Demolition of un-reinforced cement concrete in ground floors and pavings in any position thickness. (Below or above ground level) and removing rubbish off premises n exc 500 m complete all as specified.
Taking down old chowkhats with shutters (without taking off shutters from frame n. exc. 1.5 sqm each) complete all as specified and as directed.
Taking down old chowkhats with shutters (without taking off shutters from frame exc. 1.5 sqm but n. exc. 4.00 sqm each) complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified.
M&L for brick work with sub class 'B' bricks old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surface to fair and even without using extra cement complete all as specified and as directed
Supply, fixing and fabrication for mild steel work as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410-W (Gde E250) quality B complete all as specified and directed
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying 2 coat of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and as directed.
M&L cement concrete Type B1 1:2:4 (20 mm graded aggregate) in copings, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating, as directedcomplete all as specified and directed.
S&F 150mm dia PVC (SWR) pipe with solvent and PVC clamps complete all as specified.
S&F 150mm dia PVC (SWR) bend fixed with solvent complete all as specified.
S&F 150mm dia PVC (SWR) tee fixed with solvent complete all as specified.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified.
M&L for glazed ceramic colour tiles in vertical surface of size 450 X 300 x 7 mm thick,over and including 10 mm thick cement palster in cm 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
S&F false ceiling of 12.5 mm thick tapered edge gypsum board confirming to IS 2095 including providing and fixing frame work made out of special sections power pressed from MS Sheet and galvanised in accordance with zink coating and consisting of angle cleat of size 25 mm wide X 1.6 mm thick with flange of 22 mm and 37 mm at 1.2 mtr C/C , Angle fixed to the ceiling with dash fastener 12.5 mm dia x 40 mm long with 6 mm dia bolts to the angle hangers of 25x25x5 mm running @1.2 mtr C/C to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm , shall be fixed in a direction perpendicular to GI Channel with connecting clips made out of 2.64 mm dia x 130 mm long GI wire at every in including fixing the gypsum board with ceiling section and perimeter channel 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long the perimeter of ceiling fixed to wall / partition with the help of raw plug at 450 mm c/c with 25 mm long screws @ 230 mm internal including jointing and fixing to a flush finish of tapered and square edge the gypsum board with filler and finish with POP as per approved colour, paper tapes including making opening for light fittings ,AC grills,diffusers cut outs made with frames of perimeter channels complete in plain horizontally / vertically location including applying coats of plastic emulsion paint over a coat of approved primer on gypsum board false ceiling horizontally / vertically as specified (at ceiling height up to 8 mtr appx) complete all as specified . Note: Dismantling of E/M & AC services such as cables and supply lines, ducts and any other service lines has to be removed and refixed as per E/M schedule without affecting existing services and problem during execution .
S&F toughened glass frameless door with fixed portion, of 12 mm thickness, including cutting holes, edges rounded and etching works etc and all kind of SS patch fitting & fixture, spider patch etc, complete all as specified.
S&F of stainless steel handle 450 mm long fixed to 12 mm thick toughned glass door with and including all fixing accessories i. e. bolt washer, adhesive etc, complete all as specified.
S&F of SS door lock fixed at center, glass to glass type, suitable for 12 mm thick frameless toughned glass door with and incl all fixing accessories i. e. bolt, washer, screw, adhesive etc of suitable size, complete all as specified.
S & F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified.
M&L for preparation of newly plastered wall surfaces and applying two coat of oil emulsion distemper over one coat wall care putty (average thickness of 1.5 mm) complete all as specified and directed by Engr-in-Charge
Providing and fixing in repair aluminium composite panels cladding of approved make having total thickness of 4 mm (Top coil -0.5mm , non Toxic PE - Core - 3 mm and back Coil -0.50 mm ) with 25 micron PVdF Coating on top coil and polyester / epoxy coating on back coil ( 4-7 microns ) on aluminium substructure fixed with 19 mm x 12 mm x 1.6 mm aluminium cleat & 10 x 100 mm SS Wooden screw with PVC plug on faced horizontal/ vertical surfaces of rectangular / circular columns ,suspended ceiling Cills , jambs ,canopy with including neccessary aluminium frame ,scafolding etc and making 12 mm to 20 mm wide grooves and applying non staining and non streaking sealant of Dow corning ( 789 or 991 HP) and backing rods complete as specified and approved shade by Engr in charge . Only exposed surface shall be measured and paid for ACP Material shall be for exterior application &of shade as approved by Garrision Engineer .
Removal of demolished material or soil to a distance n.exc 500M and depositing where directed at a level n.exc. 1.5 M above the starting point Complete all specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil Complete all specified and directed.
M&L PCC in foundations, filling and mass-concrete type C2 (1:3:6) using 40 mm graded stone aggregate Complete all specified and directed.
S&F for Plates (plain or chequered) channels. Square cut or notched (ordinary & counter sunk) forming holes, without any attachment GDE Fe410-0 or Fe 250-O quality B Complete all specified and directed.
Surface excavation n.exc 30cm deep & averaging 15cm deep and getting out in soft / loose soil.Complete all specified and directed.
M&L 100mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as in foundation, sub base,Complete all specified and directed.
M&L Machine cut kota stone slab flooring 18-20mm thick over 20mm thick screed in CM(1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing Complete all specified and directed.
M&L for preparation of new or previously untreated wall surface and applying two coats of exterior weather proof paint (Apex) over a coat of primer and two coats of wall care putty, Complete all specified and directed.
M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60 mm thick suitable for modular/conventional switches/sockets/fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing for One light point/ceiling fan/exhaust fan/bell point controlled by one switch, complete all as specified and directed Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates. The conduit pipe concealed in roof will not be changed.
All as per srl item No. 34 here-in-before but One socket outlet 5 Amps controlled by one switch on same board
All as per srl item No. 34 here-in-before but One socket outlet 5 amps controlled by one switch on independent board
All as per srl item No. 34 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.
Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including cutting and chasing,and also PVC conduit suitable dia as per SSR part-I with medium grade including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified and directed by Engr-in Charge. Note : 1. The two run of 4 Sqmm wire, one run of 4 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
All as per srl item no. 38 here-in-before but with 2 run of 10.0 sq mm FRLS copper wire with 10.0 Sqmm FRLS copper cable as earth wire.
S&F modular switch 6 Amps, one way, one module 240 volts complete all as specified and directed.
S&F modular switch 16 A, 1 module,240 volts complete all as specified and directed.
S&F modular socket, 3 pin 6 Amps,240 volts, 2 module complete all as specified and directed.
S&F modular socket 6/16 A, 5 pin, 2 module, 240 volts complete all as specified and directed.
Supply and fixing electronic fan regulator, Modular type and making all necessary connections complete all as specified.
Supply and fix Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps with and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified.
Supply and fix MCB protected modular AC/Geyser box complete with and including 6 pin socket, plug top, modular cover plate, mini MCB SP 20 Amp capacity and PVC gang box etc, complete all as specified and directed by Engineer-in charge.
S&F recessed mounting LED light fitting (flat panel) 2' x2' with high efficeint LEDs and Glare free and opal diffuser of 36 watt (CW) including fixing accessories likes strip clips etc and Color Rendering Index (CRI>80), correlated Color Temparature (CCT- 5700K) , PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
Supply and fix Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections complete all as specified.
M&L MCB SP 6 to 32 Amp, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified.
Supply and fixing MCB, SPN type of 40 to 63 amps capacity, 240V, 10 KA with all connections complete all as specified.
S&F LED tube light fitting 20 watt (CW) , 4 feet long in polycabonate housing with high efficient LEDs available in milky diffuser and Color Rendering Index (CRI>80), correlated Color Temparature (CCT- 6500K) , PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed by Engr-in-Charge.
Supply and install hi wall split units indoor/outdoor hot and cold type complete with cordless remote contrill unit with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and fixing voltage stablizer 5 kva operating voltage 170-270 V, single phase 415 V 50 HZ complete all as specified and directed by Engr-in-Charge.
ACR ENTERPRISES
SURESH KUMAR SHARMA & CO
M/s SAAR ENGINEERS
friends associeates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .